Abstract:
:Cardiac motion estimation is very important in understanding cardiac dynamics and in noninvasive diagnosis of heart disease. Magnetic resonance (MR) imaging tagging is a technique for measuring heart deformations. In cardiac tagged MR images, a set of dark lines are noninvasively encoded within myocardial tissue providing the means for measurement of deformations of the heart. The points along tag lines measured in different frames and in different directions carry important information for determining the three-dimensional nonrigid movement of left ventricle. However, these measurements are sparse and, therefore, multidimensional interpolation techniques are needed to reconstruct a dense displacement field. In this paper, a novel subspace approximation technique is used to accomplish this task. We formulate the displacement estimation as a variational problem and then project the solution into spline subspaces. Efficient numerical methods are derived by taking advantages of B-spline properties. The proposed technique significantly improves our previous results reported in [3] with respect to computational time. The method is applied to a temporal sequence of two-dimensional images and is validated with simulated and in vivo heart data.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Wang YP,Chen Y,Amini AAdoi
10.1109/42.929616subject
Has Abstractpub_date
2001-06-01 00:00:00pages
499-513issue
6eissn
0278-0062issn
1558-254Xjournal_volume
20pub_type
杂志文章abstract::Micro-computed tomography (micro-CT) has been widely used to generate high-resolution 3-D tissue images from small animals nondestructively, especially for mineralized skeletal tissues. However, its application to the analysis of soft cardiovascular tissues has been limited by poor inter-tissue contrast. Recent ex viv...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2209183
更新日期:2013-01-01 00:00:00
abstract::Following B.B. Mandelbrot's fractal theory (1982), it was found that the fractal dimension could be obtained in medical images by the concept of fractional Brownian motion. An estimation concept for determination of the fractal dimension based upon the concept of fractional Brownian motion is discussed. Two applicatio...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.24861
更新日期:1989-01-01 00:00:00
abstract::Computerized detection of clustered microcalcifications (MCs) in mammograms often suffers from the occurrence of false positives (FPs), which can vary greatly from case to case. We investigate how to apply statistical estimation to determine the number of FPs that are present in a detected MC lesion. First, we describ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2654799
更新日期:2017-05-01 00:00:00
abstract::Glaucoma is a leading cause of irreversible blindness. Accurate segmentation of the optic disc (OD) and optic cup (OC) from fundus images is beneficial to glaucoma screening and diagnosis. Recently, convolutional neural networks demonstrate promising progress in the joint OD and OC segmentation. However, affected by t...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2899910
更新日期:2019-11-01 00:00:00
abstract::A method for measuring the spatial concentration of specific categories of vessels in a vascular network consisting of vessels of several diameters, lengths, and orientations is demonstrated. It is shown that a combination of the mathematical morphology operation, opening, with a linear rotating structuring element (R...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.241865
更新日期:1993-01-01 00:00:00
abstract::In this paper, the accuracy of material decomposition (MD) using an energy discriminating photon counting detector was studied. An MD framework was established and validated using calcium hydroxyapatite (CaHA) inserts of known densities (50 mg/cm3, 100 mg/cm3, 250 mg/cm3, 400 mg/cm3), and diameters (1.2, 3.0, and 5.0 ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2914370
更新日期:2020-01-01 00:00:00
abstract::Time-of-flight (TOF) positron emission tomography (PET) scanners offer the potential for significantly improved signal-to-noise ratio (SNR) and lesion detectability in clinical PET. However, fully 3D TOF PET image reconstruction is a challenging task due to the huge data size. One solution to this problem is to rebin ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2149537
更新日期:2011-10-01 00:00:00
abstract::Two methods for recovering an image that has been degraded while being processed are presented. The restoration problem is formulated as a constrained optimization problem in which a measure of smoothness based on the second derivatives of the restored image is maximized subject to the constraint that noise energy is ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.126904
更新日期:1992-01-01 00:00:00
abstract::The development and tests of an iterative reconstruction algorithm for emission tomography based on Bayesian statistical concepts are described. The algorithm uses the entropy of the generated image as a prior distribution, can be accelerated by the choice of an exponent, and converges uniformly to feasible images by ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.56340
更新日期:1990-01-01 00:00:00
abstract::For fully characterizing renal cell carcinoma (RCC), information about the 3D tissue microstructure is essential. Histopathology, which represents the current diagnostic gold standard, is destructive and only provides 2D information. 3D X-ray histology endeavors to overcome these limitations by generating 3D data. In ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2952028
更新日期:2020-05-01 00:00:00
abstract::Optical coherence tomography (OCT) uses retroreflected light to provide micrometer-resolution, cross-sectional scans of biological tissues. OCT's first application was in ophthalmic imaging where it has proven particularly useful in diagnosing, monitoring, and studying glaucoma. Diagnosing glaucoma is difficult and it...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2006.871417
更新日期:2006-05-01 00:00:00
abstract::We are presenting data from the largest clinical trial on optical tomographic imaging of finger joints to date. Overall we evaluated 99 fingers of patients affected by rheumatoid arthritis (RA) and 120 fingers from healthy volunteers. Using frequency-domain imaging techniques we show that sensitivities and specificiti...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2135374
更新日期:2011-10-01 00:00:00
abstract::Segmentation-based scores play an important role in the evaluation of computational tools in medical image analysis. These scores evaluate the quality of various tasks, such as image registration and segmentation, by measuring the similarity between two binary label maps. Commonly these measurements blend two aspects ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2216281
更新日期:2012-12-01 00:00:00
abstract::Magnetic Resonance-Electrical Properties Tomography (MR-EPT) is an imaging modality that maps the spatial distribution of the electrical conductivity and permittivity using standard MRI systems. The presence of a body within the scanner alters the RF field, and by mapping these alterations it is possible to recover th...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2466082
更新日期:2016-01-01 00:00:00
abstract::This paper describes the implementation of a novel and robust threshold energy calibration method for photon counting detectors using polychromatic X-ray tubes. Methods often used for such energy calibration may require re-orientation of the detector or introduce calibration errors that are flux and acquisition time-d...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2875932
更新日期:2019-04-01 00:00:00
abstract::We present a method (DMESH) for nonrigid cyclic motion analysis using a series of velocity images covering the cycle acquired, for example, from phase-contrast magnetic resonance imaging. The method is based on fitting a dynamic finite-element mesh model to velocity samples of an extended region, at all time frames. T...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.790456
更新日期:1999-07-01 00:00:00
abstract::A new reconstruction method, coined MIRAGE, is presented for accurate, fast, and robust parameter mapping of multiple-echo gradient-echo (MEGE) imaging, the basis sequence of novel quantitative magnetic resonance imaging techniques such as water content and susceptibility mapping. Assuming that the temporal signal can...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2771504
更新日期:2018-02-01 00:00:00
abstract::Magnetic nanoparticles can be caused to oscillate under the influence of an incident ultrasonic wave. If the particles are momentarily aligned with a magnetizing pulse creating a macroscopic magnetization, this oscillation will result in a time-varying magnetic moment which should be detectable as an induced voltage i...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2007.895476
更新日期:2007-05-01 00:00:00
abstract::An algorithm is developed for electrical impedance tomography (EIT) of finite cylinders with general cross-sectional boundaries and translationally uniform conductivity distributions. The electrodes for data collection are assumed to be placed around a cross-sectional plane; therefore, the axial variation of the bound...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.52982
更新日期:1990-01-01 00:00:00
abstract::A three-dimensional reconstruction method which uses cone-beam data was implemented. Issues concerning implementation are investigated and discussed in detail. Computer simulations were used to determine the amount of image degradation occurring in each of the three steps that comprise the reconstruction method. In ad...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.141650
更新日期:1992-01-01 00:00:00
abstract::We propose a joint information approach for automatic analysis of 2D echocardiography (echo) data. The approach combines a priori images, their segmentations and patient diagnostic information within a unified framework to determine various clinical parameters, such as cardiac chamber volumes, and cardiac disease labe...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2593900
更新日期:2017-01-01 00:00:00
abstract::In dynamic planar imaging, extraction of signals specific to structures is complicated by structures superposition. Due to overlapping, signals extraction with classic regions of interest (ROIs) methods suffers from inaccuracy, as extracted signals are a mixture of targeted signals. Partial volume effect raises the sa...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2759661
更新日期:2018-01-01 00:00:00
abstract::Ultra-short TE (UTE) sequences with radial sampling make it possible to visualize tissues with very short T2 decay times. The UTE sequence acquires an echo signal from the central to the outer parts of k-space and is very sensitive to small trajectory errors. Therefore, k-space errors caused by imperfections in the gr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2012.2226050
更新日期:2013-02-01 00:00:00
abstract::This paper presents a novel method for validation of nonrigid medical image registration. This method is based on the simulation of physically plausible, biomechanical tissue deformations using finite-element methods. Applying a range of displacements to finite-element models of different patient anatomies generates m...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2002.808367
更新日期:2003-02-01 00:00:00
abstract::Prostate cancer (PCa) recurrences are often predicted by assessing the status of surgical margins (SM)- positive surgical margins (PSM) increase the chances of biochemical recurrence by 2-4 times which may lead to PCa recurrence. To this end, an electrical impedance acquisition system with a microendoscopic probe was ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2578939
更新日期:2016-12-01 00:00:00
abstract::In waveform design for magnetic resonance applications, periodic continuous-wave excitation offers potential advantages that remain largely unexplored because of a lack of understanding of the Bloch equation with periodic continuous-wave excitations. Using harmonic balancing techniques the steady state solutions of th...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2423313
更新日期:2015-10-01 00:00:00
abstract::Digital processing that increases resolution by spatial deconvolution and histogram-based amplitude mapping has been used to improve ultrasonic abdominal image quality. The processing was applied to pulse-echo ultrasound data obtained from clinical imaging instrumentation modified to permit digital recording of signal...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1983.4307617
更新日期:1983-01-01 00:00:00
abstract::The comment of Stig Steenstrup on the use of gray level entropy function in our paper' has been addressed. The entropy measure has not been used in the procedure of enhancement, but it has only been used to show statistically that the enhanced images have larger gray level entropy, and therefore better utilize the gra...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.1987.4307802
更新日期:1987-01-01 00:00:00
abstract::Temporal resolution in time-resolved cone-beam CT (TR-CBCT) imaging is often limited by the time needed to acquire a complete data set for image reconstruction. With the recent developments of performing nearly limited-view artifact-free reconstruction from data in a limited-view angle range and a prior image, tempora...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2960720
更新日期:2020-06-01 00:00:00
abstract::Automatic and accurate classification of retinal optical coherence tomography (OCT) images is essential to assist ophthalmologist in the diagnosis and grading of macular diseases. Clinically, ophthalmologists usually diagnose macular diseases according to the structures of macular lesions, whose morphologies, size, an...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2898414
更新日期:2019-08-01 00:00:00