Revealing the Microscopic Structure of Human Renal Cell Carcinoma in Three Dimensions.

Abstract:

:For fully characterizing renal cell carcinoma (RCC), information about the 3D tissue microstructure is essential. Histopathology, which represents the current diagnostic gold standard, is destructive and only provides 2D information. 3D X-ray histology endeavors to overcome these limitations by generating 3D data. In a laboratory environment, most techniques struggle with limited resolution and the weak X-ray attenuation contrast of soft tissue. We recently developed a laboratory-based method combining nanoscopic X-ray CT with a cytoplasm-specific X-ray stain. Here, we present the application of this method to human RCC biopsies. The NanoCT slices enable pathological characterization of crucial structures by reproducing tissue morphology with a similar detail level as corresponding histological light microscopy images. Beyond that, our data offer deeper insights into the 3D configuration of the tumor. By demonstrating the compatibility of the X-ray stain with standard pathological stains, we highlight the feasibility of integrating staining based NanoCT into the pathological routine.

journal_name

IEEE Trans Med Imaging

authors

Ferstl S,Busse M,Muller M,Kimm MA,Drecoll E,Burkner T,Allner S,Dierolf M,Pfeiffer D,Rummeny EJ,Weichert W,Pfeiffer F

doi

10.1109/TMI.2019.2952028

subject

Has Abstract

pub_date

2020-05-01 00:00:00

pages

1494-1500

issue

5

eissn

0278-0062

issn

1558-254X

journal_volume

39

pub_type

杂志文章
  • Red Lesion Detection Using Dynamic Shape Features for Diabetic Retinopathy Screening.

    abstract::The development of an automatic telemedicine system for computer-aided screening and grading of diabetic retinopathy depends on reliable detection of retinal lesions in fundus images. In this paper, a novel method for automatic detection of both microaneurysms and hemorrhages in color fundus images is described and va...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2509785

    authors: Seoud L,Hurtut T,Chelbi J,Cheriet F,Langlois JM

    更新日期:2016-04-01 00:00:00

  • Closing the Gap between Deep Neural Network Modeling and Biomedical Decision-Making Metrics in Segmentation via Adaptive Loss Functions.

    abstract::Deep learning is becoming an indispensable tool for various tasks in science and engineering. A critical step in constructing a reliable deep learning model is the selection of a loss function, which measures the discrepancy between the network prediction and the ground truth. While a variety of loss functions have be...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3031913

    authors: Seo H,Bassenne M,Xing L

    更新日期:2020-10-19 00:00:00

  • Hot spot detection based on feature space representation of visual search.

    abstract::This paper presents a new framework for capturing intrinsic visual search behavior of different observers in image understanding by analysing saccadic eye movements in feature space. The method is based on the information theory for identifying salient image features based on which visual search is performed. We demon...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2003.816959

    authors: Hu XP,Dempere-Marco L,Yang GZ

    更新日期:2003-09-01 00:00:00

  • The n-PI-method for helical cone-beam CT.

    abstract::A new class of acquisition schemes for helical cone-beam computed tomography (CB-CT) scanning is introduced, and their effect on the reconstruction methods is analyzed. These acquisition schemes are based on a new detector shape that is bounded by the helix. It will be shown that the data acquired with these schemes a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.887834

    authors: Proksa R,Köhler T,Grass M,Timmer J

    更新日期:2000-09-01 00:00:00

  • Application of micro-computed tomography with iodine staining to cardiac imaging, segmentation, and computational model development.

    abstract::Micro-computed tomography (micro-CT) has been widely used to generate high-resolution 3-D tissue images from small animals nondestructively, especially for mineralized skeletal tissues. However, its application to the analysis of soft cardiovascular tissues has been limited by poor inter-tissue contrast. Recent ex viv...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2209183

    authors: Aslanidi OV,Nikolaidou T,Zhao J,Smaill BH,Gilbert SH,Holden AV,Lowe T,Withers PJ,Stephenson RS,Jarvis JC,Hancox JC,Boyett MR,Zhang H

    更新日期:2013-01-01 00:00:00

  • Neuron Segmentation With High-Level Biological Priors.

    abstract::We present a novel approach to the problem of neuron segmentation in image volumes acquired by an electron microscopy. Existing methods, such as agglomerative or correlation clustering, rely solely on boundary evidence and have problems where such an evidence is lacking (e.g., incomplete staining) or ambiguous (e.g., ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2712360

    authors: Krasowski NE,Beier T,Knott GW,Kothe U,Hamprecht FA,Kreshuk A

    更新日期:2018-04-01 00:00:00

  • Automated Chest X-Ray Screening: Can Lung Region Symmetry Help Detect Pulmonary Abnormalities?

    abstract::Our primary motivator is the need for screening HIV+ populations in resource-constrained regions for exposure to Tuberculosis, using posteroanterior chest radiographs (CXRs). The proposed method is motivated by the observation that radiological examinations routinely conduct bilateral comparisons of the lung field. In...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2775636

    authors: Santosh KC,Antani S

    更新日期:2018-05-01 00:00:00

  • Image guided personalization of reaction-diffusion type tumor growth models using modified anisotropic eikonal equations.

    abstract::Reaction-diffusion based tumor growth models have been widely used in the literature for modeling the growth of brain gliomas. Lately, recent models have started integrating medical images in their formulation. Including different tissue types, geometry of the brain and the directions of white matter fiber tracts impr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2026413

    authors: Konukoglu E,Clatz O,Menze BH,Stieltjes B,Weber MA,Mandonnet E,Delingette H,Ayache N

    更新日期:2010-01-01 00:00:00

  • A probabilistic model-based approach to consistent white matter tract segmentation.

    abstract::Since the invention of diffusion magnetic resonance imaging (dMRI), currently the only established method for studying white matter connectivity in a clinical environment, there has been a great deal of interest in the effects of various pathologies on the connectivity of the brain. As methods for in vivo tractography...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.905826

    authors: Clayden JD,Storkey AJ,Bastin ME

    更新日期:2007-11-01 00:00:00

  • PVR: Patch-to-Volume Reconstruction for Large Area Motion Correction of Fetal MRI.

    abstract::In this paper, we present a novel method for the correction of motion artifacts that are present in fetal magnetic resonance imaging (MRI) scans of the whole uterus. Contrary to current slice-to-volume registration (SVR) methods, requiring an inflexible anatomical enclosure of a single investigated organ, the proposed...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2737081

    authors: Alansary A,Rajchl M,McDonagh SG,Murgasova M,Damodaram M,Lloyd DFA,Davidson A,Rutherford M,Hajnal JV,Rueckert D,Kainz B

    更新日期:2017-10-01 00:00:00

  • Direct Parametric Reconstruction Using Anatomical Regularization for Simultaneous PET/MRI Data.

    abstract::Pharmacokinetic analysis of dynamic positron emission tomography (PET) imaging data maps the measured time activity curves to a set of model-specific pharmacokinetic parameters. Voxel-based parameter estimation via curve fitting is conventionally performed indirectly on a sequence of independently reconstructed PET im...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2427777

    authors: Loeb R,Navab N,Ziegler SI

    更新日期:2015-11-01 00:00:00

  • Evaluation of Fisher Information Matrix-Based Methods for Fast Assessment of Image Quality in Pinhole SPECT.

    abstract::The accurate determination of the local impulse response and the covariance in voxels from penalized maximum likelihood reconstructed images requires performing reconstructions from many noise realizations of the projection data. As this is usually a very time-consuming process, efficient analytical approximations bas...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2410342

    authors: Pato LR,Vandenberghe S,Vandeghinste B,Van Holen R

    更新日期:2015-09-01 00:00:00

  • Prior-Attention Residual Learning for More Discriminative COVID-19 Screening in CT Images.

    abstract::We propose a conceptually simple framework for fast COVID-19 screening in 3D chest CT images. The framework can efficiently predict whether or not a CT scan contains pneumonia while simultaneously identifying pneumonia types between COVID-19 and Interstitial Lung Disease (ILD) caused by other viruses. In the proposed ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2994908

    authors: Wang J,Bao Y,Wen Y,Lu H,Luo H,Xiang Y,Li X,Liu C,Qian D

    更新日期:2020-08-01 00:00:00

  • Microwave image reconstruction utilizing log-magnitude and unwrapped phase to improve high-contrast object recovery.

    abstract::Reconstructing images of large high-contrast objects with microwave methods has proved difficult. Successful images have generally been obtained by using a priori information to constrain the image reconstruction to recover the correct electromagnetic property distribution. In these situations, the measured electric f...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.913177

    authors: Meaney PM,Paulsen KD,Pogue BW,Miga MI

    更新日期:2001-02-01 00:00:00

  • Elastic registration in the presence of intensity variations.

    abstract::We have developed a general-purpose registration algorithm for medical images and volumes. This method models the transformation between images as locally affine but globally smooth. The model also explicitly accounts for local and global variations in image intensities. This approach is built upon a differential mult...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.815069

    authors: Periaswamy S,Farid H

    更新日期:2003-07-01 00:00:00

  • Spatiotemporal forward solution of the EEG and MEG using network modeling.

    abstract::Dynamic systems have proven to be well suited to describe a broad spectrum of human coordination behavior such synchronization with auditory stimuli. Simultaneous measurements of the spatiotemporal dynamics of electroencephalographic (EEG) and magnetoencephalographic (MEG) data reveals that the dynamics of the brain s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.1009385

    authors: Jirsa VK,Jantzen KJ,Fuchs A,Kelso JA

    更新日期:2002-05-01 00:00:00

  • Two iterative image restoration algorithms with applications to nuclear medicine.

    abstract::Two methods for recovering an image that has been degraded while being processed are presented. The restoration problem is formulated as a constrained optimization problem in which a measure of smoothness based on the second derivatives of the restored image is maximized subject to the constraint that noise energy is ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.126904

    authors: Charalambous C,Ghaddar FK,Kouris K

    更新日期:1992-01-01 00:00:00

  • Estimating kinetic parameter maps from dynamic contrast-enhanced MRI using spatial prior knowledge.

    abstract::Dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging can be used to study microvascular structure in vivo by monitoring the abundance of an injected diffusible contrast agent over time. The resulting spatially resolved intensity-time curves are usually interpreted in terms of kinetic parameters obtained by fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2019957

    authors: Kelm BM,Menze BH,Nix O,Zechmann CM,Hamprecht FA

    更新日期:2009-10-01 00:00:00

  • Adaptive speckle reduction filter for log-compressed B-scan images.

    abstract::A good statistical model of speckle formation is useful for designing a good adaptive filter for speckle reduction In ultrasound B-scan images. Previously, statistical models have been used, but they failed to account for the log compression of the echo envelope employed by clinical ultrasound systems. Log-compression...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.544498

    authors: Dutt V,Greenleaf JF

    更新日期:1996-01-01 00:00:00

  • PORTR: Pre-operative and post-recurrence brain tumor registration.

    abstract::We propose a new method for deformable registration of pre-operative and post-recurrence brain MR scans of glioma patients. Performing this type of intra-subject registration is challenging as tumor, resection, recurrence, and edema cause large deformations, missing correspondences, and inconsistent intensity profiles...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2293478

    authors: Kwon D,Niethammer M,Akbari H,Bilello M,Davatzikos C,Pohl KM

    更新日期:2014-03-01 00:00:00

  • A proof of the spherical homeomorphism conjecture for surfaces.

    abstract::The human cerebral cortex is topologically equivalent to a sphere when it is viewed as closed at the brain stem. Due to noise and/or resolution issues, magnetic resonance imaging may see "handles" that need to be eliminated to reflect the true spherical topology. Shattuck and Leahy present an algorithm to correct such...

    journal_title:IEEE transactions on medical imaging

    pub_type: 评论,信件

    doi:10.1109/TMI.2002.806590

    authors: Abrams L,Fishkind DE,Priebe CE

    更新日期:2002-12-01 00:00:00

  • 3-D Contrast Source Inversion-Electrical Properties Tomography.

    abstract::Contrast source inversion-electrical properties tomography (CSI-EPT) is an iterative reconstruction method to retrieve the electrical properties (EPs) of tissues from magnetic resonance data. The method is based on integral representations of the electromagnetic field and has been shown to allow EP reconstructions of ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2816125

    authors: Leijsen RL,Brink WM,van den Berg CAT,Webb AG,Remis RF

    更新日期:2018-09-01 00:00:00

  • Automatic Segmentation and Quantification of White and Brown Adipose Tissues from PET/CT Scans.

    abstract::In this paper, we investigate the automatic detection of white and brown adipose tissues using Positron Emission Tomography/Computed Tomography (PET/CT) scans, and develop methods for the quantification of these tissues at the whole-body and body-region levels. We propose a patient-specific automatic adiposity analysi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2636188

    authors: Hussein S,Green A,Watane A,Reiter D,Chen X,Papadakis GZ,Wood B,Cypess A,Osman M,Bagci U

    更新日期:2017-03-01 00:00:00

  • Dynamic contrast-enhanced MRI-based early detection of acute renal transplant rejection.

    abstract::A novel framework for the classification of acute rejection versus nonrejection status of renal transplants from 2-D dynamic contrast-enhanced magnetic resonance imaging is proposed. The framework consists of four steps. First, kidney objects are segmented from adjacent structures with a level set deformable boundary ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2269139

    authors: Khalifa F,Beache GM,El-Ghar MA,El-Diasty T,Gimel'farb G,Kong M,El-Baz A

    更新日期:2013-10-01 00:00:00

  • Computer-assisted scan protocol and reconstruction (CASPAR)-reduction of image noise and patient dose.

    abstract::X-ray computed tomography is a powerful medical imaging device. It allows high-resolution 3-D visualization of the human body. However, one drawback is the health risk associated with ionizing radiation. Simply downscaling the radiation intensities over the entire scan results in increased quantum noise. This paper pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2034515

    authors: Sperl J,Beque D,Claus B,De Man B,Senzig B,Brokate M

    更新日期:2010-03-01 00:00:00

  • The GEM MAP algorithm with 3-D SPECT system response.

    abstract::In single photon emission computed tomography (SPECT), every reconstruction algorithm must use some model for the response of the gamma camera to emitted gamma-rays. The true camera response is both spatially variant and object dependent. These two properties result from the effects of scatter, septal penetration, and...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.126914

    authors: Hebert TJ,Gopal SS

    更新日期:1992-01-01 00:00:00

  • Accuracy of in vivo neuroreceptor quantification by PET and review of steady-state, transient, double injection, and equilibrium models.

    abstract::The accuracy of in vivo dopamine D2 receptor quantification by positron emission tomography (PET) was determined for several models by means of singular-value decomposition, and some of the model assumptions were reviewed. These include steady-state, transient, double injection, and equilibrium approaches. All four mo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.7783

    authors: Zeeberg BR,Gibson RE,Reba RC

    更新日期:1988-01-01 00:00:00

  • Classifying mammographic lesions using computerized image analysis.

    abstract::The classification of 3 common breast lesions, fibroadenomas, cysts, and cancers, was achieved using computerized image analysis of tumor shape in conjunction with patient age. The process involved the digitization of 69 mammographic images using a video camera and a commercial frame grabber on a PC-based computer sys...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.251116

    authors: Kilday J,Palmieri F,Fox MD

    更新日期:1993-01-01 00:00:00

  • A spatiotemporal model of cyclic kinematics and its application to analyzing nonrigid motion with MR velocity images.

    abstract::We present a method (DMESH) for nonrigid cyclic motion analysis using a series of velocity images covering the cycle acquired, for example, from phase-contrast magnetic resonance imaging. The method is based on fitting a dynamic finite-element mesh model to velocity samples of an extended region, at all time frames. T...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.790456

    authors: Zhu Y,Pelc NJ

    更新日期:1999-07-01 00:00:00

  • Out-of-plane motion compensation in multislice spin-echo MRI.

    abstract::In magnetic resonance imaging (MRI), it is well-known that patient motion plays a significant role in the degradation of image quality. Although the case of translational in-plane motion (x-y-motion) has been studied by several researchers, the effect of rigid, translational out-of-plane motion (z-motion) has not yet ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.414611

    authors: Riek JK,Tekalp AM,Smith WE,Kwok E

    更新日期:1995-01-01 00:00:00