Abstract:
:Reconstructing images of large high-contrast objects with microwave methods has proved difficult. Successful images have generally been obtained by using a priori information to constrain the image reconstruction to recover the correct electromagnetic property distribution. In these situations, the measured electric field phases as a function of receiver position around the periphery of the imaging field-of-view vary rapidly often undergoing changes of greater than pi radians especially when the object contrast and illumination frequency increase. In this paper, we introduce a modified form of a Maxwell equation model-based image reconstruction algorithm which directly incorporates log-magnitude and phase of the measured electric field data. By doing so, measured phase variation can be unwrapped and distributed over more than one Rieman sheet in the complex plane. Simulation studies and microwave imaging experiments demonstrate that significant image quality enhancements occur with this approach for large high-contrast objects. Simple strategies for visualizing and unwrapping phase values as a function of the transmitter and receiver positions within our microwave imaging array are described. Metrics of the degree of phase variation expressed in terms of the amount and extent of phase wrapping are defined and found to be figures-of-merit which estimate when it is critical to deploy the new image reconstruction approach. In these cases, the new algorithm recovers high-quality images without resorting to the use of a priori information on object contrast and/or size as previously required.
journal_name
IEEE Trans Med Imagingjournal_title
IEEE transactions on medical imagingauthors
Meaney PM,Paulsen KD,Pogue BW,Miga MIdoi
10.1109/42.913177subject
Has Abstractpub_date
2001-02-01 00:00:00pages
104-16issue
2eissn
0278-0062issn
1558-254Xjournal_volume
20pub_type
杂志文章abstract::The study presented in this paper tests the hypothesis that the combination of a global similarity transformation and local free-form deformations can be used for the accurate segmentation of internal structures in MR images of the brain. To quantitatively evaluate our approach, the entire brain, the cerebellum, and t...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.811271
更新日期:1999-10-01 00:00:00
abstract::To reconstruct electrical activity in the heart from body-surface electrocardiograms (ECGs) is an ill-posed inverse problem. Electrophysiological models have been found effective in regularizing these inverse problems by incorporating a priori knowledge about how the electrical potential in the heart propagates over t...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2906600
更新日期:2019-11-01 00:00:00
abstract::A fully automated approach to segmentation of the left and right cardiac ventricles from magnetic resonance (MR) images is reported. A novel multistage hybrid appearance model methodology is presented in which a hybrid active shape model/active appearance model (AAM) stage helps avoid local minima of the matching func...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.925294
更新日期:2001-05-01 00:00:00
abstract::Video capsule endoscopy (VCE) is a noninvasive method for examining the gastrointestinal tract which has been successful in small intestine studies. Recently, VCE has been attempted in the colon. However, the capsule often tumbles in the wider colonic lumen, resulting in missed regions. Self-stabilizing VCE is a novel...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2163165
更新日期:2011-12-01 00:00:00
abstract::The development of an automatic telemedicine system for computer-aided screening and grading of diabetic retinopathy depends on reliable detection of retinal lesions in fundus images. In this paper, a novel method for automatic detection of both microaneurysms and hemorrhages in color fundus images is described and va...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2509785
更新日期:2016-04-01 00:00:00
abstract::We present an integrated approach to probabilistic independent component analysis (ICA) for functional MRI (FMRI) data that allows for nonsquare mixing in the presence of Gaussian noise. In order to avoid overfitting, we employ objective estimation of the amount of Gaussian noise through Bayesian analysis of the true ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.822821
更新日期:2004-02-01 00:00:00
abstract::The presence of high-density objects remains an open problem in medical CT imaging. Data of projections passing through objects of high density, such as metal implants, are dominated by noise and are highly affected by beam hardening and scatter. Reconstructed images become less diagnostically conclusive because of pr...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2015.2459764
更新日期:2016-01-01 00:00:00
abstract::We present a novel method to segment instances of glandular structures from colon histopathology images. We use a structure learning approach which represents local spatial configurations of class labels, capturing structural information normally ignored by sliding-window methods. This allows us to reveal different sp...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2750210
更新日期:2018-01-01 00:00:00
abstract::Functional magnetic resonance images (fMRI's) provide high-resolution datasets which allow researchers to obtain accurate delineation and sensitive detection of activation areas involved in cognitive processes. To preserve the resolution of this noninvasive technique, refined methods are required in the analysis of th...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.746636
更新日期:1998-12-01 00:00:00
abstract::Echo-planar imaging (EPI) is a fast nuclear magnetic resonance imaging (MRI) method. Unfortunately, local magnetic field inhomogeneities induced mainly by the subject's presence cause significant geometrical distortion, predominantly along the phase-encoding direction, which must be undone to allow for meaningful furt...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.836368
更新日期:2000-02-01 00:00:00
abstract::High-resolution X-ray computed tomography (CT) imaging is routinely used for clinical pulmonary applications. Since lung function varies regionally and because pulmonary disease is usually not uniformly distributed in the lungs, it is useful to study the lungs on a lobe-by-lobe basis. Thus, it is important to segment ...
journal_title:IEEE transactions on medical imaging
pub_type: 临床试验,杂志文章
doi:10.1109/TMI.2005.859209
更新日期:2006-01-01 00:00:00
abstract::Tracing of left-ventricular epicardial and endocardial borders on echocardiographic sequences is essential for quantification of cardiac function. The authors designed a method based on an extension of active contour models to detect both epicardial and endocardial borders on short-axis cardiac sequences spanning the ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.500138
更新日期:1996-01-01 00:00:00
abstract::An n-dimensional (n-D) filtered backprojection image reconstruction algorithm has been developed and used in the reconstruction of 4-D spectral-spatial magnetic resonance imaging (MRI) data. The algorithm uses n-1 successive stages of 2-D filtered backprojection to reconstruct an n-D image. This approach results in a ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.387718
更新日期:1995-01-01 00:00:00
abstract::3D Statistical Shape Models (3D-SSM) are widely used for medical image segmentation. However, during segmentation, they typically perform a very limited unidirectional search for suitable landmark positions in the image, relying on weak learners or use-case specific appearance models that solely take local image infor...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2016.2600502
更新日期:2017-01-01 00:00:00
abstract::Atherosclerosis at the carotid bifurcation resulting in cerebral emboli is a major cause of ischemic stroke. Most strokes associated with carotid atherosclerosis can be prevented by lifestyle/dietary changes and pharmacological treatments if identified early by monitoring carotid plaque changes. Registration of 3-D ul...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.918326
更新日期:2008-10-01 00:00:00
abstract::The magnetic particle imaging (MPI) method directly images the magnetization of super-paramagnetic iron oxide (SPIO) nanoparticles, which are contrast agents commonly used in magnetic resonance imaging (MRI). MPI, as originally envisioned, requires a high-bandwidth receiver coil and preamplifier, which are difficult t...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2009.2013849
更新日期:2009-08-01 00:00:00
abstract::Magnetic resonance fingerprinting (MRF) is a quantitative imaging technique that can simultaneously measure multiple important tissue properties of human body. Although MRF has demonstrated improved scan efficiency as compared to conventional techniques, further acceleration is still desired for translation into routi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2019.2899328
更新日期:2019-10-01 00:00:00
abstract::This paper investigates the problem of atlas registration of brain images with gliomas. Multiparametric imaging modalities (T1, T1-CE, T2, and FLAIR) are first utilized for segmentations of different tissues, and to compute the posterior probability map (PBM) of membership to each tissue class, using supervised learni...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2010.2078833
更新日期:2011-02-01 00:00:00
abstract::In this paper, we propose a novel deep learning framework for anatomy segmentation and automatic landmarking. Specifically, we focus on the challenging problem of mandible segmentation from cone-beam computed tomography (CBCT) scans and identification of 9 anatomical landmarks of the mandible on the geodesic space. Th...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2018.2875814
更新日期:2019-04-01 00:00:00
abstract::When time-varying gradients are used for imaging, the off-resonance behavior does not just cause geometric distortion as is the case with spin-warp imaging, but changes the shape of the impulse response and causes blurring. This effect is well known for projection reconstruction and spiral k-space scanning sequences. ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.108599
更新日期:1991-01-01 00:00:00
abstract::Conventional Doppler ultrasound is useful for visualizing fast blood flow in large resolvable vessels. However, frame rate and tissue clutter caused by movement of the patient or sonographer make visualizing slow flow with ultrasound difficult. Patient and sonographer motion causes spectral broadening of the clutter s...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2714901
更新日期:2017-09-01 00:00:00
abstract::Most existing CNNs-based segmentation methods rely on local appearances learned on the regular image grid, without consideration of the object global information. This article aims to embed the object global geometric information into a learning framework via the classical geodesic active contours (GAC). We propose a ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.3022693
更新日期:2021-01-01 00:00:00
abstract::The purpose of this work is to study the architecture of the rearfoot using in vivo MR image data. Each data set used in this study is made of sixty sagittal slices of the foot acquired in a 1.5-T commercial GE MR system. We use the live-wire method to delineate boundaries and form the surfaces of the bones. In the fi...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.802753
更新日期:1999-09-01 00:00:00
abstract::Breast imaging via microwave tomography involves estimating the distribution of dielectric properties within the patient's breast on a discrete mesh. The number of unknowns in the discrete mesh can be very large for 3-D imaging, and this results in computational challenges. We propose a new approach where the discrete...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2008.2008959
更新日期:2009-07-01 00:00:00
abstract::In in-utero MRI, motion correction for fetal body and placenta poses a particular challenge due to the presence of local non-rigid transformations of organs caused by bending and stretching. The existing slice-to-volume registration (SVR) reconstruction methods are widely employed for motion correction of fetal brain ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2020.2974844
更新日期:2020-09-01 00:00:00
abstract::Computerized detection of clustered microcalcifications (MCs) in mammograms often suffers from the occurrence of false positives (FPs), which can vary greatly from case to case. We investigate how to apply statistical estimation to determine the number of FPs that are present in a detected MC lesion. First, we describ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2017.2654799
更新日期:2017-05-01 00:00:00
abstract::This paper presents a new variational method for the segmentation of a moving object against a still background, over a sequence of [two-dimensional or three-dimensional (3-D)] image frames. The method is illustrated in application to myocardial gated single photon emission computed tomography (SPECT) data, and incorp...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/42.932748
更新日期:2001-07-01 00:00:00
abstract::Small pulmonary nodules are a common radiographic finding that presents an important diagnostic challenge in contemporary medicine. While pulmonary nodules are the major radiographic indicator of lung cancer, they may also be signs of a variety of benign conditions. Measurement of nodule growth rate over time has been...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2003.817785
更新日期:2003-10-01 00:00:00
abstract::Simulations provide a way of generating data where ground truth is known, enabling quantitative testing of image processing methods. In this paper, we present the construction of 20 realistic digital brain phantoms that can be used to simulate medical imaging data. The phantoms are made from 20 normal adults to take i...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2006.883453
更新日期:2006-11-01 00:00:00
abstract::Radio-frequency (RF) transceiver array design using primary and higher order harmonics for in vivo parallel magnetic resonance imaging imaging (MRI) and spectroscopic imaging is proposed. The improved electromagnetic decoupling performance, unique magnetic field distributions and high-frequency operation capabilities ...
journal_title:IEEE transactions on medical imaging
pub_type: 杂志文章
doi:10.1109/TMI.2011.2166273
更新日期:2012-02-01 00:00:00