Validation of nonrigid image registration using finite-element methods: application to breast MR images.

Abstract:

:This paper presents a novel method for validation of nonrigid medical image registration. This method is based on the simulation of physically plausible, biomechanical tissue deformations using finite-element methods. Applying a range of displacements to finite-element models of different patient anatomies generates model solutions which simulate gold standard deformations. From these solutions, deformed images are generated with a range of deformations typical of those likely to occur in vivo. The registration accuracy with respect to the finite-element simulations is quantified by co-registering the deformed images with the original images and comparing the recovered voxel displacements with the biomechanically simulated ones. The functionality of the validation method is demonstrated for a previously described nonrigid image registration technique based on free-form deformations using B-splines and normalized mutual information as a voxel similarity measure, with an application to contrast-enhanced magnetic resonance mammography image pairs. The exemplar nonrigid registration technique is shown to be of subvoxel accuracy on average for this particular application. The validation method presented here is an important step toward more generic simulations of biomechanically plausible tissue deformations and quantification of tissue motion recovery using nonrigid image registration. It will provide a basis for improving and comparing different nonrigid registration techniques for a diversity of medical applications, such as intrasubject tissue deformation or motion correction in the brain, liver or heart.

journal_name

IEEE Trans Med Imaging

authors

Schnabel JA,Tanner C,Castellano-Smith AD,Degenhard A,Leach MO,Hose DR,Hill DL,Hawkes DJ

doi

10.1109/TMI.2002.808367

subject

Has Abstract

pub_date

2003-02-01 00:00:00

pages

238-47

issue

2

eissn

0278-0062

issn

1558-254X

journal_volume

22

pub_type

杂志文章
  • Association Between Changes in Mammographic Image Features and Risk for Near-Term Breast Cancer Development.

    abstract::The purpose of this study is to develop and test a new computerized model for predicting near-term breast cancer risk based on quantitative assessment of bilateral mammographic image feature variations in a series of negative full-field digital mammography (FFDM) images. The retrospective dataset included series of fo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2527619

    authors: Tan M,Zheng B,Leader JK,Gur D

    更新日期:2016-07-01 00:00:00

  • Adaptive speckle reduction filter for log-compressed B-scan images.

    abstract::A good statistical model of speckle formation is useful for designing a good adaptive filter for speckle reduction In ultrasound B-scan images. Previously, statistical models have been used, but they failed to account for the log compression of the echo envelope employed by clinical ultrasound systems. Log-compression...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.544498

    authors: Dutt V,Greenleaf JF

    更新日期:1996-01-01 00:00:00

  • Computer Aided Theragnosis Using Quantitative Ultrasound Spectroscopy and Maximum Mean Discrepancy in Locally Advanced Breast Cancer.

    abstract::A noninvasive computer-aided-theragnosis (CAT) system was developed for the early therapeutic cancer response assessment in patients with locally advanced breast cancer (LABC) treated with neoadjuvant chemotherapy. The proposed CAT system was based on multi-parametric quantitative ultrasound (QUS) spectroscopic method...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2495246

    authors: Gangeh MJ,Tadayyon H,Sannachi L,Sadeghi-Naini A,Tran WT,Czarnota GJ

    更新日期:2016-03-01 00:00:00

  • A maximum a posteriori probability expectation maximization algorithm for image reconstruction in emission tomography.

    abstract::The expectation maximization method for maximum likelihood image reconstruction in emission tomography, based on the Poisson distribution of the statistically independent components of the image and measurement vectors, is extended to a maximum aposteriori image reconstruction using a multivariate Gaussian a priori pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1987.4307826

    authors: Levitan E,Herman GT

    更新日期:1987-01-01 00:00:00

  • Application of active contours for photochromic tracer flow extraction.

    abstract::This paper addresses the implementation of image processing and computer vision techniques to automate tracer flow extraction in images obtained by the photochromic dye technique. This task is important in modeled arterial blood flow studies. Currently, it is performed via manual application of B-spline curve fitting....

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.585762

    authors: Androutsos D,Trahanias PE,Venetsanopoulos AN

    更新日期:1997-06-01 00:00:00

  • Advanced level-set-based cell tracking in time-lapse fluorescence microscopy.

    abstract::Cell segmentation and tracking in time-lapse fluorescence microscopy images is a task of fundamental importance in many biological studies on cell migration and proliferation. In recent years, level sets have been shown to provide a very appropriate framework for this purpose, as they are well suited to capture topolo...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2038693

    authors: Dzyubachyk O,van Cappellen WA,Essers J,Niessen WJ,Meijering E

    更新日期:2010-03-01 00:00:00

  • Free-breathing diffusion tensor imaging and tractography of the human heart in healthy volunteers using wavelet-based image fusion.

    abstract::Free-breathing cardiac diffusion tensor imaging (DTI) is a promising but challenging technique for the study of fiber structures of the human heart in vivo. This work proposes a clinically compatible and robust technique to provide three-dimensional (3-D) fiber architecture properties of the human heart. To this end, ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2356792

    authors: Wei H,Viallon M,Delattre BM,Moulin K,Yang F,Croisille P,Zhu Y

    更新日期:2015-01-01 00:00:00

  • Accelerated Parameter Mapping of Multiple-Echo Gradient-Echo Data Using Model-Based Iterative Reconstruction.

    abstract::A new reconstruction method, coined MIRAGE, is presented for accurate, fast, and robust parameter mapping of multiple-echo gradient-echo (MEGE) imaging, the basis sequence of novel quantitative magnetic resonance imaging techniques such as water content and susceptibility mapping. Assuming that the temporal signal can...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2771504

    authors: Zimmermann M,Abbas Z,Dzieciol K,Shah NJ

    更新日期:2018-02-01 00:00:00

  • A comprehensive cardiac motion estimation framework using both untagged and 3-D tagged MR images based on nonrigid registration.

    abstract::In this paper, we present a novel technique based on nonrigid image registration for myocardial motion estimation using both untagged and 3-D tagged MR images. The novel aspect of our technique is its simultaneous usage of complementary information from both untagged and 3-D tagged MR images. To estimate the motion wi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2188104

    authors: Shi W,Zhuang X,Wang H,Duckett S,Luong DV,Tobon-Gomez C,Tung K,Edwards PJ,Rhode KS,Razavi RS,Ourselin S,Rueckert D

    更新日期:2012-06-01 00:00:00

  • Estimating average growth trajectories in shape-space using kernel smoothing.

    abstract::In this paper, we show how a dense surface point distribution model of the human face can be computed and demonstrate the usefulness of the high-dimensional shape-space for expressing the shape changes associated with growth and aging. We show how average growth trajectories for the human face can be computed in the a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.814784

    authors: Hutton TJ,Buxton BF,Hammond P,Potts HW

    更新日期:2003-06-01 00:00:00

  • Estimation of Strain Elastography from Ultrasound Radio-Frequency Data by Utilizing Analytic Gradient of the Similarity Metric.

    abstract::Most strain imaging techniques follow a pipeline strategy: in the first step, tissue displacement is estimated from radio-frequency (RF) frames, and in the second step, a spatial derivative operation is applied. There are two main issues that arise from this framework. First, the gradient operation amplifies noise, an...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2685522

    authors: Omidyeganeh M,Xiao Y,Ahmad MO,Rivaz H

    更新日期:2017-06-01 00:00:00

  • Detailed Evaluation of Five 3D Speckle Tracking Algorithms Using Synthetic Echocardiographic Recordings.

    abstract::A plethora of techniques for cardiac deformation imaging with 3D ultrasound, typically referred to as 3D speckle tracking techniques, are available from academia and industry. Although the benefits of single methods over alternative ones have been reported in separate publications, the intrinsic differences in the dat...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2537848

    authors: Alessandrini M,Heyde B,Queiros S,Cygan S,Zontak M,Somphone O,Bernard O,Sermesant M,Delingette H,Barbosa D,De Craene M,ODonnell M,Dhooge J

    更新日期:2016-08-01 00:00:00

  • Digital processing for improvement of ultrasonic abdominal images.

    abstract::Digital processing that increases resolution by spatial deconvolution and histogram-based amplitude mapping has been used to improve ultrasonic abdominal image quality. The processing was applied to pulse-echo ultrasound data obtained from clinical imaging instrumentation modified to permit digital recording of signal...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1983.4307617

    authors: Liu CN,Fatemi M,Waag RC

    更新日期:1983-01-01 00:00:00

  • Lumen segmentation and motion estimation in B-mode and contrast-enhanced ultrasound images of the carotid artery in patients with atherosclerotic plaque.

    abstract::In standard B-mode ultrasound (BMUS), segmentation of the lumen of atherosclerotic carotid arteries and studying the lumen geometry over time are difficult owing to irregular lumen shapes, noise, artifacts, and echolucent plaques. Contrast enhanced ultrasound (CEUS) improves lumen visualization, but lumen segmentation...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2372784

    authors: Carvalho DD,Akkus Z,van den Oord SC,Schinkel AF,van der Steen AF,Niessen WJ,Bosch JG,Klein S

    更新日期:2015-04-01 00:00:00

  • FiloGen: A Model-Based Generator of Synthetic 3-D Time-Lapse Sequences of Single Motile Cells With Growing and Branching Filopodia.

    abstract::The existence of diverse image datasets accompanied by reference annotations is a crucial prerequisite for an objective benchmarking of bioimage analysis methods. Nevertheless, such a prerequisite is hard to satisfy for time lapse, multidimensional fluorescence microscopy image data, manual annotations of which are la...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2845884

    authors: Sorokin DV,Peterlik I,Ulman V,Svoboda D,Necasova T,Morgaenko K,Eiselleova L,Tesarova L,Maska M

    更新日期:2018-12-01 00:00:00

  • Head Motion Correction Based on Filtered Backprojection in Helical CT Scanning.

    abstract::Head motion may unexpectedly occur during a CT scan. It thereby results in motion artifacts in a reconstructed image and may lead to a false diagnosis or a failure of diagnosis. To alleviate this motion problem, as a hardware approach, increasing the gantry rotation speed or using an immobilization device is usually c...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2953974

    authors: Jang S,Kim S,Kim M,Son K,Lee KY,Ra JB

    更新日期:2020-05-01 00:00:00

  • A characterization of the geometric architecture of the peritalar joint complex via MRI: an aid to the classification of foot type.

    abstract::The purpose of this work is to study the architecture of the rearfoot using in vivo MR image data. Each data set used in this study is made of sixty sagittal slices of the foot acquired in a 1.5-T commercial GE MR system. We use the live-wire method to delineate boundaries and form the surfaces of the bones. In the fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.802753

    authors: Stindel E,Udupa JK,Hirsch BE,Odhner D

    更新日期:1999-09-01 00:00:00

  • The GEM MAP algorithm with 3-D SPECT system response.

    abstract::In single photon emission computed tomography (SPECT), every reconstruction algorithm must use some model for the response of the gamma camera to emitted gamma-rays. The true camera response is both spatially variant and object dependent. These two properties result from the effects of scatter, septal penetration, and...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.126914

    authors: Hebert TJ,Gopal SS

    更新日期:1992-01-01 00:00:00

  • Exact radon rebinning algorithm for the long object problem in helical cone-beam CT.

    abstract::This paper addresses the long object problem in helical cone-beam computed tomography. We present the PHI-method, a new algorithm for the exact reconstruction of a region-of-interest (ROI) of a long object from axially truncated data extending only slightly beyond the ROI. The PHI-method is an extension of the Radon-m...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.870247

    authors: Schaller S,Sauer F,Tam KC,Lauritsch G,Flohr T

    更新日期:2000-05-01 00:00:00

  • A geometric method for automatic extraction of sulcal fundi.

    abstract::Sulcal fundi are 3-D curves that lie in the depths of the cerebral cortex and, in addition to their intrinsic value in brain research, are often used as landmarks for downstream computations in brain imaging. In this paper, we present a geometric algorithm that automatically extracts the sulcal fundi from magnetic res...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.886810

    authors: Kao CY,Hofer M,Sapiro G,Stem J,Rehm K,Rottenberg DA

    更新日期:2007-04-01 00:00:00

  • Spatiotemporal forward solution of the EEG and MEG using network modeling.

    abstract::Dynamic systems have proven to be well suited to describe a broad spectrum of human coordination behavior such synchronization with auditory stimuli. Simultaneous measurements of the spatiotemporal dynamics of electroencephalographic (EEG) and magnetoencephalographic (MEG) data reveals that the dynamics of the brain s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.1009385

    authors: Jirsa VK,Jantzen KJ,Fuchs A,Kelso JA

    更新日期:2002-05-01 00:00:00

  • 3-D reconstruction of tissue components for atherosclerotic human arteries using ex vivo high-resolution MRI.

    abstract::Automatic computer-based methods are well suited for the image analysis of the different components in atherosclerotic plaques. Although several groups work on such analysis some of the methods used are oversimplified and require improvements when used within a computational framework for predicting meaningful stress ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.870485

    authors: Auer M,Stollberger R,Regitnig P,Ebner F,Holzapfel GA

    更新日期:2006-03-01 00:00:00

  • Spatial-resolution enhancement in computed tomography.

    abstract::We propose an approach that combines an asymmetric fan-beam configuration and a new reconstruction algorithm to enhancing spatial resolution in computed tomography (CT). The asymmetric configuration can be achieved by changing the center of rotation (COR) from the conventional symmetric configuration. It does not, how...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.840846

    authors: Pan X,Yu L,Kao CM

    更新日期:2005-02-01 00:00:00

  • Quantifying the statistical impact of GRAPPA in fcMRI data with a real-valued isomorphism.

    abstract::The interpolation of missing spatial frequencies through the generalized auto-calibrating partially parallel acquisitions (GRAPPA) parallel magnetic resonance imaging (MRI) model implies a correlation is induced between the acquired and reconstructed frequency measurements. As the parallel image reconstruction algorit...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2288521

    authors: Bruce IP,Rowe DB

    更新日期:2014-02-01 00:00:00

  • Improved SPECT quantitation using fully three-dimensional iterative spatially variant scatter response compensation.

    abstract::The quality and quantitative accuracy of iteratively reconstructed SPECT images improves when better point spread function (PSF) models of the gamma camera are used during reconstruction. Here, inclusion in the PSF model of photon crosstalk between different slices caused by limited gamma camera resolution and scatter...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.511752

    authors: Beekman FJ,Kamphuis C,Viergever MA

    更新日期:1996-01-01 00:00:00

  • Noninvasive mapping of transmural potentials during activation in swine hearts from body surface electrocardiograms.

    abstract::The three-dimensional cardiac electrical imaging (3DCEI) technique was previously developed to estimate the initiation site(s) of cardiac activation and activation sequence from the noninvasively measured body surface potential maps (BSPMs). The aim of this study was to develop and evaluate the capability of 3DCEI in ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2202914

    authors: Liu C,Eggen MD,Swingen CM,Iaizzo PA,He B

    更新日期:2012-09-01 00:00:00

  • Automatic Cataract Classification Using Deep Neural Network With Discrete State Transition.

    abstract::Cataract is the clouding of lens, which affects vision and it is the leading cause of blindness in the world's population. Accurate and convenient cataract detection and cataract severity evaluation will improve the situation. Automatic cataract detection and grading methods are proposed in this paper. With prior know...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2928229

    authors: Zhou Y,Li G,Li H

    更新日期:2020-02-01 00:00:00

  • Lung segmentation in chest radiographs using anatomical atlases with nonrigid registration.

    abstract::The National Library of Medicine (NLM) is developing a digital chest X-ray (CXR) screening system for deployment in resource constrained communities and developing countries worldwide with a focus on early detection of tuberculosis. A critical component in the computer-aided diagnosis of digital CXRs is the automatic ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2290491

    authors: Candemir S,Jaeger S,Palaniappan K,Musco JP,Singh RK,Zhiyun Xue,Karargyris A,Antani S,Thoma G,McDonald CJ

    更新日期:2014-02-01 00:00:00

  • 3D Statistical Shape Models Incorporating Landmark-Wise Random Regression Forests for Omni-Directional Landmark Detection.

    abstract::3D Statistical Shape Models (3D-SSM) are widely used for medical image segmentation. However, during segmentation, they typically perform a very limited unidirectional search for suitable landmark positions in the image, relying on weak learners or use-case specific appearance models that solely take local image infor...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2600502

    authors: Norajitra T,Maier-Hein KH

    更新日期:2017-01-01 00:00:00

  • Gaussian process models of dynamic PET for functional volume definition in radiation oncology.

    abstract::In routine oncologic positron emission tomography (PET), dynamic information is discarded by time-averaging the signal to produce static images of the "standardised uptake value" (SUV). Defining functional volumes of interest (VOIs) in terms of SUV is flawed, as values are affected by confounding factors and the chose...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2193896

    authors: Shepherd T,Owenius R

    更新日期:2012-08-01 00:00:00