Detailed Evaluation of Five 3D Speckle Tracking Algorithms Using Synthetic Echocardiographic Recordings.

Abstract:

:A plethora of techniques for cardiac deformation imaging with 3D ultrasound, typically referred to as 3D speckle tracking techniques, are available from academia and industry. Although the benefits of single methods over alternative ones have been reported in separate publications, the intrinsic differences in the data and definitions used makes it hard to compare the relative performance of different solutions. To address this issue, we have recently proposed a framework to simulate realistic 3D echocardiographic recordings and used it to generate a common set of ground-truth data for 3D speckle tracking algorithms, which was made available online. The aim of this study was therefore to use the newly developed database to contrast non-commercial speckle tracking solutions from research groups with leading expertise in the field. The five techniques involved cover the most representative families of existing approaches, namely block-matching, radio-frequency tracking, optical flow and elastic image registration. The techniques were contrasted in terms of tracking and strain accuracy. The feasibility of the obtained strain measurements to diagnose pathology was also tested for ischemia and dyssynchrony.

journal_name

IEEE Trans Med Imaging

authors

Alessandrini M,Heyde B,Queiros S,Cygan S,Zontak M,Somphone O,Bernard O,Sermesant M,Delingette H,Barbosa D,De Craene M,ODonnell M,Dhooge J

doi

10.1109/TMI.2016.2537848

subject

Has Abstract

pub_date

2016-08-01 00:00:00

pages

1915-26

issue

8

eissn

0278-0062

issn

1558-254X

journal_volume

35

pub_type

杂志文章
  • Artificial Neural Network Enhanced Bayesian PET Image Reconstruction.

    abstract::In positron emission tomography (PET) image reconstruction, the Bayesian framework with various regularization terms has been implemented to constrain the radio tracer distribution. Varying the regularizing weight of a maximum a posteriori (MAP) algorithm specifies a lower bound of the tradeoff between variance and sp...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2803681

    authors: Yang B,Ying L,Tang J

    更新日期:2018-06-01 00:00:00

  • Automatic segmentation of scaling in 2-D psoriasis skin images.

    abstract::Psoriasis is a chronic inflammatory skin disease that affects over 3% of the population. Various methods are currently used to evaluate psoriasis severity and to monitor therapeutic response. The PASI system of scoring is widely used for evaluating psoriasis severity. It employs a visual analogue scale to score the th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2236349

    authors: Lu J,Kazmierczak E,Manton JH,Sinclair R

    更新日期:2013-04-01 00:00:00

  • Quantification of MR brain images by mixture density and partial volume modeling.

    abstract::The problem of automatic quantification of brain tissue by utilizing single-valued (single echo) magnetic resonance imaging (MRI) brain scans is addressed. It is shown that this problem can be solved without classification or segmentation, a method that may be particularly useful in quantifying white matter lesions wh...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.241885

    authors: Santago P,Gage HD

    更新日期:1993-01-01 00:00:00

  • A hardware architecture using finite-field arithmetic for computing maximum-likelihood estimates in emission tomography.

    abstract::A special-purpose hardware architecture is proposed to implement the expectation-maximization algorithm to compute, in clinically useful times, the maximum-likelihood estimate of a radionuclide distribution for a positron-emission tomogram from time-of-flight measurements. Two-dimensional convolutions required for for...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.14510

    authors: Klotz HR,Snyder DL

    更新日期:1988-01-01 00:00:00

  • Three-dimensional PET emission scan registration and transmission scan synthesis.

    abstract::The duration of a positron emission tomography (PET) imaging scan can be reduced if the transmission scan of one patient which is used for emission correction can be synthesized by using the reference transmission scan of another patient. In this paper, we propose a new intersubjects PET emission scan registration met...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.640744

    authors: Huang CL,Chang WT,Wu LC,Wang JK

    更新日期:1997-10-01 00:00:00

  • Deep Learning for Fast and Spatially Constrained Tissue Quantification From Highly Accelerated Data in Magnetic Resonance Fingerprinting.

    abstract::Magnetic resonance fingerprinting (MRF) is a quantitative imaging technique that can simultaneously measure multiple important tissue properties of human body. Although MRF has demonstrated improved scan efficiency as compared to conventional techniques, further acceleration is still desired for translation into routi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2899328

    authors: Fang Z,Chen Y,Liu M,Xiang L,Zhang Q,Wang Q,Lin W,Shen D

    更新日期:2019-10-01 00:00:00

  • Application of micro-computed tomography with iodine staining to cardiac imaging, segmentation, and computational model development.

    abstract::Micro-computed tomography (micro-CT) has been widely used to generate high-resolution 3-D tissue images from small animals nondestructively, especially for mineralized skeletal tissues. However, its application to the analysis of soft cardiovascular tissues has been limited by poor inter-tissue contrast. Recent ex viv...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2209183

    authors: Aslanidi OV,Nikolaidou T,Zhao J,Smaill BH,Gilbert SH,Holden AV,Lowe T,Withers PJ,Stephenson RS,Jarvis JC,Hancox JC,Boyett MR,Zhang H

    更新日期:2013-01-01 00:00:00

  • A Predictive Model of Vertebral Trabecular Anisotropy From Ex Vivo Micro-CT.

    abstract::Spine-related disorders are amongst the most frequently encountered problems in clinical medicine. For several applications such as 1) to improve the assessment of the strength of the spine, as well as 2) to optimize the personalization of spinal interventions, image-based biomechanical modeling of the vertebrae is ex...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2387114

    authors: Lekadir K,Hoogendoorn C,Hazrati-Marangalou J,Taylor Z,Noble C,van Rietbergen B,Frangi AF

    更新日期:2015-08-01 00:00:00

  • Local noise weighted filtering for emphysema scoring of low-dose CT images.

    abstract::Computed tomography (CT) has become the new reference standard for quantification of emphysema. The most popular measure of emphysema derived from CT is the pixel index (PI), which expresses the fraction of the lung volume with abnormally low intensity values. As PI is calculated from a single, fixed threshold on inte...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.871545

    authors: Schilham AM,van Ginneken B,Gietema H,Prokop M

    更新日期:2006-04-01 00:00:00

  • Video-Rate Ring-Array Ultrasound and Photoacoustic Tomography.

    abstract::Ultrasonography and photoacoustic tomography provide complementary contrasts in preclinical studies, disease diagnoses, and imaging-guided interventional procedures. Here, we present a video-rate (20 Hz) dual-modality ultrasound and photoacoustic tomographic platform that has a high resolution, rich contrasts, deep pe...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3017815

    authors: Zhang Y,Wang L

    更新日期:2020-12-01 00:00:00

  • Improved Low-Count Quantitative PET Reconstruction With an Iterative Neural Network.

    abstract::Image reconstruction in low-count PET is particularly challenging because gammas from natural radioactivity in Lu-based crystals cause high random fractions that lower the measurement signal-to-noise-ratio (SNR). In model-based image reconstruction (MBIR), using more iterations of an unregularized method may increase ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2998480

    authors: Lim H,Chun IY,Dewaraja YK,Fessler JA

    更新日期:2020-11-01 00:00:00

  • Multi-Task Deep Model With Margin Ranking Loss for Lung Nodule Analysis.

    abstract::Lung cancer is the leading cause of cancer deaths worldwide and early diagnosis of lung nodule is of great importance for therapeutic treatment and saving lives. Automated lung nodule analysis requires both accurate lung nodule benign-malignant classification and attribute score regression. However, this is quite chal...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2934577

    authors: Liu L,Dou Q,Chen H,Qin J,Heng PA

    更新日期:2020-03-01 00:00:00

  • Estimating kinetic parameter maps from dynamic contrast-enhanced MRI using spatial prior knowledge.

    abstract::Dynamic contrast-enhanced magnetic resonance (DCE-MR) imaging can be used to study microvascular structure in vivo by monitoring the abundance of an injected diffusible contrast agent over time. The resulting spatially resolved intensity-time curves are usually interpreted in terms of kinetic parameters obtained by fi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2019957

    authors: Kelm BM,Menze BH,Nix O,Zechmann CM,Hamprecht FA

    更新日期:2009-10-01 00:00:00

  • Automated detection of prostatic adenocarcinoma from high-resolution ex vivo MRI.

    abstract::Prostatic adenocarcinoma is the most commonly occurring cancer among men in the United States, second only to skin cancer. Currently, the only definitive method to ascertain the presence of prostatic cancer is by trans-rectal ultrasound (TRUS) directed biopsy. Owing to the poor image quality of ultrasound, the accurac...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2005.859208

    authors: Madabhushi A,Feldman MD,Metaxas DN,Tomaszeweski J,Chute D

    更新日期:2005-12-01 00:00:00

  • Spatio-temporal fMRI analysis using Markov random fields.

    abstract::Functional magnetic resonance images (fMRI's) provide high-resolution datasets which allow researchers to obtain accurate delineation and sensitive detection of activation areas involved in cognitive processes. To preserve the resolution of this noninvasive technique, refined methods are required in the analysis of th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.746636

    authors: Descombes X,Kruggel F,von Cramon DY

    更新日期:1998-12-01 00:00:00

  • A maximum a posteriori probability expectation maximization algorithm for image reconstruction in emission tomography.

    abstract::The expectation maximization method for maximum likelihood image reconstruction in emission tomography, based on the Poisson distribution of the statistically independent components of the image and measurement vectors, is extended to a maximum aposteriori image reconstruction using a multivariate Gaussian a priori pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1987.4307826

    authors: Levitan E,Herman GT

    更新日期:1987-01-01 00:00:00

  • A wavelet-based multiresolution regularized least squares reconstruction approach for optical tomography.

    abstract::In this paper, we present a wavelet-based multigrid approach to solve the perturbation equation encountered in optical tomography. With this scheme, the unknown image, the data, as well as the weight matrix are all represented by wavelet expansions, thus yielding a multiresolution representation of the original pertur...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.563666

    authors: Zhu W,Wang Y,Deng Y,Yao Y,Barbour RL

    更新日期:1997-04-01 00:00:00

  • A fast Bayesian reconstruction algorithm for emission tomography with entropy prior converging to feasible images.

    abstract::The development and tests of an iterative reconstruction algorithm for emission tomography based on Bayesian statistical concepts are described. The algorithm uses the entropy of the generated image as a prior distribution, can be accelerated by the choice of an exponent, and converges uniformly to feasible images by ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.56340

    authors: Nunez J,Llacer J

    更新日期:1990-01-01 00:00:00

  • Head Motion Correction Based on Filtered Backprojection in Helical CT Scanning.

    abstract::Head motion may unexpectedly occur during a CT scan. It thereby results in motion artifacts in a reconstructed image and may lead to a false diagnosis or a failure of diagnosis. To alleviate this motion problem, as a hardware approach, increasing the gantry rotation speed or using an immobilization device is usually c...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2953974

    authors: Jang S,Kim S,Kim M,Son K,Lee KY,Ra JB

    更新日期:2020-05-01 00:00:00

  • Microwave image reconstruction utilizing log-magnitude and unwrapped phase to improve high-contrast object recovery.

    abstract::Reconstructing images of large high-contrast objects with microwave methods has proved difficult. Successful images have generally been obtained by using a priori information to constrain the image reconstruction to recover the correct electromagnetic property distribution. In these situations, the measured electric f...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.913177

    authors: Meaney PM,Paulsen KD,Pogue BW,Miga MI

    更新日期:2001-02-01 00:00:00

  • Statistical distributions of DCT coefficients and their application to an interframe compression algorithm for 3-D medical images.

    abstract::Displacement estimated interframe (DEI) coding, a coding scheme for 3-D medical image data sets such as X-ray computed tomography (CT) or magnetic resonance (MR) images, is presented. To take advantage of the correlation between contiguous slices, a displacement-compensated difference image based on the previous image...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.241875

    authors: Lee H,Kim Y,Rowberg AH,Riskin EA

    更新日期:1993-01-01 00:00:00

  • Gaussian process models of dynamic PET for functional volume definition in radiation oncology.

    abstract::In routine oncologic positron emission tomography (PET), dynamic information is discarded by time-averaging the signal to produce static images of the "standardised uptake value" (SUV). Defining functional volumes of interest (VOIs) in terms of SUV is flawed, as values are affected by confounding factors and the chose...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2193896

    authors: Shepherd T,Owenius R

    更新日期:2012-08-01 00:00:00

  • BICAV: a block-iterative parallel algorithm for sparse systems with pixel-related weighting.

    abstract::Component averaging (CAV) was recently introduced by Censor, Gordon, and Gordon as a new iterative parallel technique suitable for large and sparse unstructured systems of linear equations. Based on earlier work of Byrne and Censor, it uses diagonal weighting matrices, with pixel-related weights determined by the spar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.959302

    authors: Censor Y,Gordon D,Gordon R

    更新日期:2001-10-01 00:00:00

  • Detection and Localization of Ultrasound Scatterers Using Convolutional Neural Networks.

    abstract::Delay-and-sum (DAS) beamforming is unable to identify individual scatterers when their density is so high that their point spread functions overlap. This paper proposes a convolutional neural network (CNN)-based method to detect and localize high-density scatterers, some of which are closer than the resolution limit o...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3006445

    authors: Youn J,Ommen ML,Stuart MB,Thomsen EV,Larsen NB,Jensen JA

    更新日期:2020-12-01 00:00:00

  • An investigation of methods of pileup rejection for 2-D array detectors employed in high resolution PET.

    abstract::Two methods of rejecting pileup events in 2-D array detectors used in positron emission tomography (PET) are investigated. Since the methods are based on different physical properties, they were investigated separately and in combination. Method one is based on the fact that valid events in the 2-D array detector occu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.79481

    authors: Germano G,Hoffman EJ

    更新日期:1991-01-01 00:00:00

  • Resampling of data between arbitrary grids using convolution interpolation.

    abstract::For certain medical applications resampling of data is required. In magnetic resonance tomography (MRT) or computer tomography (CT), e.g., data may be sampled on nonrectilinear grids in the Fourier domain. For the image reconstruction a convolution-interpolation algorithm, often called gridding, can be applied for res...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.774166

    authors: Rasche V,Proksa R,Sinkus R,Börnert P,Eggers H

    更新日期:1999-05-01 00:00:00

  • On Bayesian image reconstruction from projections: uniform and nonuniform a priori source information.

    abstract::A method that incorporates a priori uniform or nonuniform source distribution probabilistic information and data fluctuations of a Poisson nature is presented. The source distributions are modeled in terms of a priori source probability density functions. Maximum a posteriori probability solutions, as determined by a ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.34711

    authors: Liang Z,Jaszczak R,Greer K

    更新日期:1989-01-01 00:00:00

  • Noninvasive Reconstruction of Transmural Transmembrane Potential With Simultaneous Estimation of Prior Model Error.

    abstract::To reconstruct electrical activity in the heart from body-surface electrocardiograms (ECGs) is an ill-posed inverse problem. Electrophysiological models have been found effective in regularizing these inverse problems by incorporating a priori knowledge about how the electrical potential in the heart propagates over t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2906600

    authors: Ghimire S,Sapp JL,Horacek BM,Wang L

    更新日期:2019-11-01 00:00:00

  • Estimating CT Image From MRI Data Using Structured Random Forest and Auto-Context Model.

    abstract::Computed tomography (CT) imaging is an essential tool in various clinical diagnoses and radiotherapy treatment planning. Since CT image intensities are directly related to positron emission tomography (PET) attenuation coefficients, they are indispensable for attenuation correction (AC) of the PET images. However, due...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2461533

    authors: Huynh T,Gao Y,Kang J,Wang L,Zhang P,Lian J,Shen D,Alzheimer's Disease Neuroimaging Initiative.

    更新日期:2016-01-01 00:00:00

  • The elliptical cone of uncertainty and its normalized measures in diffusion tensor imaging.

    abstract::Diffusion tensor magnetic resonance imaging (DT-MRI) is capable of providing quantitative insights into tissue microstructure in the brain. An important piece of information offered by DT-MRI is the directional preference of diffusing water molecules within a voxel. Building upon this local directional information, DT...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.915663

    authors: Koay CG,Nevo U,Chang LC,Pierpaoli C,Basser PJ

    更新日期:2008-06-01 00:00:00