Classification of malignant and benign masses based on hybrid ART2LDA approach.

Abstract:

:A new type of classifier combining an unsupervised and a supervised model was designed and applied to classification of malignant and benign masses on mammograms. The unsupervised model was based on an adaptive resonance theory (ART2) network which clustered the masses into a number of separate classes. The classes were divided into two types: one containing only malignant masses and the other containing a mix of malignant and benign masses. The masses from the malignant classes were classified by ART2. The masses from the mixed classes were input to a supervised linear discriminant classifier (LDA). In this way, some malignant masses were separated and classified by ART2 and the less distinguishable benign and malignant masses were classified by LDA. For the evaluation of classifier performance, 348 regions of interest (ROI's) containing biopsy proven masses (169 benign and 179 malignant) were used. Ten different partitions of training and test groups were randomly generated using an average of 73% of ROI's for training and 27% for testing. Classifier design, including feature selection and weight optimization, was performed with the training group. The test group was kept independent of the training group. The performance of the hybrid classifier was compared to that of an LDA classifier alone and a backpropagation neural network (BPN). Receiver operating characteristics (ROC) analysis was used to evaluate the accuracy of the classifiers. The average area under the ROC curve (A(z)) for the hybrid classifier was 0.81 as compared to 0.78 for the LDA and 0.80 for the BPN. The partial areas above a true positive fraction of 0.9 were 0.34, 0.27 and 0.31 for the hybrid, the LDA and the BPN classifier, respectively. These results indicate that the hybrid classifier is a promising approach for improving the accuracy of classification in CAD applications.

journal_name

IEEE Trans Med Imaging

authors

Hadjiiski L,Sahiner B,Chan HP,Petrick N,Helvie M

doi

10.1109/42.819327

subject

Has Abstract

pub_date

1999-12-01 00:00:00

pages

1178-87

issue

12

eissn

0278-0062

issn

1558-254X

journal_volume

18

pub_type

杂志文章
  • Fast joint reconstruction of dynamic R2* and field maps in functional MRI.

    abstract::Blood oxygen level dependent (BOLD) functional magnetic resonance imaging (fMRI) is conventionally done by reconstructing T(2)(*)-weighted images. However, since the images are unitless they are nonquantifiable in terms of important physiological parameters. An alternative approach is to reconstruct R(2)(*) maps which...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.917247

    authors: Olafsson VT,Noll DC,Fessler JA

    更新日期:2008-09-01 00:00:00

  • Framework for Photon Counting Quantitative Material Decomposition.

    abstract::In this paper, the accuracy of material decomposition (MD) using an energy discriminating photon counting detector was studied. An MD framework was established and validated using calcium hydroxyapatite (CaHA) inserts of known densities (50 mg/cm3, 100 mg/cm3, 250 mg/cm3, 400 mg/cm3), and diameters (1.2, 3.0, and 5.0 ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2914370

    authors: Juntunen MAK,Inkinen SI,Ketola JH,Kotiaho A,Kauppinen M,Winkler A,Nieminen MT

    更新日期:2020-01-01 00:00:00

  • Local noise weighted filtering for emphysema scoring of low-dose CT images.

    abstract::Computed tomography (CT) has become the new reference standard for quantification of emphysema. The most popular measure of emphysema derived from CT is the pixel index (PI), which expresses the fraction of the lung volume with abnormally low intensity values. As PI is calculated from a single, fixed threshold on inte...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2006.871545

    authors: Schilham AM,van Ginneken B,Gietema H,Prokop M

    更新日期:2006-04-01 00:00:00

  • Wound status evaluation using color image processing.

    abstract::An accurate diagnosis of burns and pressure ulcers in the early stages can be made by computerized image processing. This study describes a critical assessment of potential methodologies for noninvasive wound evaluation using a color imaging system. We also developed a method for quantifying histological readings and ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.552057

    authors: Hansen GL,Sparrow EM,Kokate JY,Leland KJ,Iaizzo PA

    更新日期:1997-02-01 00:00:00

  • Graph-based IVUS segmentation with efficient computer-aided refinement.

    abstract::A new graph-based approach for segmentation of luminal and external elastic lamina (EEL) surface of coronary vessels in gated 20 MHz intravascular ultrasound (IVUS) image sequences (volumes) is presented. The approach consists of a fully automated segmentation stage ("new automated" or NA) and a user-guided computer-a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2260763

    authors: Sun S,Sonka M,Beichel RR

    更新日期:2013-08-01 00:00:00

  • Spatial-resolution enhancement in computed tomography.

    abstract::We propose an approach that combines an asymmetric fan-beam configuration and a new reconstruction algorithm to enhancing spatial resolution in computed tomography (CT). The asymmetric configuration can be achieved by changing the center of rotation (COR) from the conventional symmetric configuration. It does not, how...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.840846

    authors: Pan X,Yu L,Kao CM

    更新日期:2005-02-01 00:00:00

  • An Enhanced SMART-RECON Algorithm for Time-Resolved C-Arm Cone-Beam CT Imaging.

    abstract::Temporal resolution in time-resolved cone-beam CT (TR-CBCT) imaging is often limited by the time needed to acquire a complete data set for image reconstruction. With the recent developments of performing nearly limited-view artifact-free reconstruction from data in a limited-view angle range and a prior image, tempora...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2960720

    authors: Li Y,Garrett JW,Li K,Strother C,Chen GH

    更新日期:2020-06-01 00:00:00

  • Comb-push ultrasound shear elastography (CUSE): a novel method for two-dimensional shear elasticity imaging of soft tissues.

    abstract::Fast and accurate tissue elasticity imaging is essential in studying dynamic tissue mechanical properties. Various ultrasound shear elasticity imaging techniques have been developed in the last two decades. However, to reconstruct a full field-of-view 2-D shear elasticity map, multiple data acquisitions are typically ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2205586

    authors: Song P,Zhao H,Manduca A,Urban MW,Greenleaf JF,Chen S

    更新日期:2012-09-01 00:00:00

  • Articulated Multi-Instrument 2-D Pose Estimation Using Fully Convolutional Networks.

    abstract::Instrument detection, pose estimation, and tracking in surgical videos are an important vision component for computer-assisted interventions. While significant advances have been made in recent years, articulation detection is still a major challenge. In this paper, we propose a deep neural network for articulated mul...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2787672

    authors: Du X,Kurmann T,Chang PL,Allan M,Ourselin S,Sznitman R,Kelly JD,Stoyanov D

    更新日期:2018-05-01 00:00:00

  • Quantification of MR brain images by mixture density and partial volume modeling.

    abstract::The problem of automatic quantification of brain tissue by utilizing single-valued (single echo) magnetic resonance imaging (MRI) brain scans is addressed. It is shown that this problem can be solved without classification or segmentation, a method that may be particularly useful in quantifying white matter lesions wh...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.241885

    authors: Santago P,Gage HD

    更新日期:1993-01-01 00:00:00

  • Probabilistic independent component analysis for functional magnetic resonance imaging.

    abstract::We present an integrated approach to probabilistic independent component analysis (ICA) for functional MRI (FMRI) data that allows for nonsquare mixing in the presence of Gaussian noise. In order to avoid overfitting, we employ objective estimation of the amount of Gaussian noise through Bayesian analysis of the true ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.822821

    authors: Beckmann CF,Smith SM

    更新日期:2004-02-01 00:00:00

  • Accurate event-driven motion compensation in high-resolution PET incorporating scattered and random events.

    abstract::With continuing improvements in spatial resolution of positron emission tomography (PET) scanners, small patient movements during PET imaging become a significant source of resolution degradation. This work develops and investigates a comprehensive formalism for accurate motion-compensated reconstruction which at the ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.917248

    authors: Rahmim A,Dinelle K,Cheng JC,Shilov MA,Segars WP,Lidstone SC,Blinder S,Rousset OG,Vajihollahi H,Tsui BM,Wong DF,Sossi V

    更新日期:2008-08-01 00:00:00

  • Quantitative ECT: Comparison of Recovery Coefficient and Linearity of Detector Response for Single Photon and Coincidence Detection (F-18, B+ 511 keV).

    abstract::The response characteristics of two tomographic systems were compared for imaging of positron emitters: a) a SPECT system with a 3/8 in crystal and 511 keV detector shielding, equipped with a specially designed 511 keV collimator, and b) a PET V system using coincidence detection. SPECT transverse plane resolution was...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1986.4307776

    authors: Clarke LP,Cullom SJ,Kenny PJ,Saw CB,Silbiger ML

    更新日期:1986-01-01 00:00:00

  • Fractal feature analysis and classification in medical imaging.

    abstract::Following B.B. Mandelbrot's fractal theory (1982), it was found that the fractal dimension could be obtained in medical images by the concept of fractional Brownian motion. An estimation concept for determination of the fractal dimension based upon the concept of fractional Brownian motion is discussed. Two applicatio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.24861

    authors: Chen CC,Daponte JS,Fox MD

    更新日期:1989-01-01 00:00:00

  • Multiobjective genetic optimization of diagnostic classifiers with implications for generating receiver operating characteristic curves.

    abstract::It is well understood that binary classifiers have two implicit objective functions (sensitivity and specificity) describing their performance. Traditional methods of classifier training attempt to combine these two objective functions (or two analogous class performance measures) into one so that conventional scalar ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.796281

    authors: Kupinski MA,Anastasio MA

    更新日期:1999-08-01 00:00:00

  • Corrections to "Direct Patlak Reconstruction From Dynamic PET Data Using the Kernel Method With MRI Information Based on Structural Similarity".

    abstract::In the above paper [1], there are typos in Algorithm 1 table. The correct version of Algorithm 1 is given below. ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章,已发布勘误

    doi:10.1109/TMI.2018.2849798

    authors: Gong K,Cheng-Liao J,Wang G,Chen KT,Catana C,Qi J

    更新日期:2018-08-01 00:00:00

  • Constrained Fourier space method for compensation of missing data in emission computed tomography.

    abstract::A method is introduced to compensate for missing projection data that can result from gas between detectors or from malfunctioning detectors. This method uses constraints in the Fourier domain to estimate the missing data, thus completing the data set so that the filtered backprojection algorithm can be used to recons...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.3925

    authors: Karp JS,Muehllehner G,Lewitt RM

    更新日期:1988-01-01 00:00:00

  • Analysis of the role of lead resistivity in specific absorption rate for deep brain stimulator leads at 3T MRI.

    abstract::Magnetic resonance imaging (MRI) on patients with implanted deep brain stimulators (DBSs) can be hazardous because of the antenna-effect of leads exposed to the incident radio-frequency field. This study evaluated electromagnetic field and specific absorption rate (SAR) changes as a function of lead resistivity on an ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2040624

    authors: Angelone LM,Ahveninen J,Belliveau JW,Bonmassar G

    更新日期:2010-04-01 00:00:00

  • A Tensor B-Spline Approach for Solving the Diffusion PDE With Application to Optical Diffusion Tomography.

    abstract::Optical Diffusion Tomography (ODT) is a modern non-invasive medical imaging modality which requires mathematical modelling of near-infrared light propagation in tissue. Solving the ODT forward problem equation accurately and efficiently is crucial. Typically, the forward problem is represented by a Diffusion PDE and i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2641500

    authors: Shulga D,Morozov O,Hunziker P

    更新日期:2017-04-01 00:00:00

  • Increased spatial resolution in transillumination using collimated light.

    abstract::In traditional transillumination of the breast (diaphanography), the abundance of diffuse light resulting from the use of extended noncollimated sources reduces the visibility of deep seated lesions. A prototype scanning imaging system has been developed to investigate the effectiveness of thin collimated light beams ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.251126

    authors: Wist AO,Fatouros PP,Herr SL

    更新日期:1993-01-01 00:00:00

  • Lung 4D CT Image Registration Based on High-Order Markov Random Field.

    abstract::To solve the problem that traditional image registration methods based on continuous optimization for large motion lung 4D CT image sequences are easy to fall into local optimal solutions and lead to serious misregistration, a novel image registration method based on high-order Markov Random Field (MRF) is proposed. B...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2937458

    authors: Xue P,Dong E,Ji H

    更新日期:2020-04-01 00:00:00

  • Hybrid feature-based diffeomorphic registration for tumor tracking in 2-D liver ultrasound images.

    abstract::Real-time ultrasound image acquisition is a pivotal resource in the medical community, in spite of its limited image quality. This poses challenges to image registration methods, particularly to those driven by intensity values. We address these difficulties in a novel diffeomorphic registration technique for tumor tr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2262055

    authors: Cifor A,Risser L,Chung D,Anderson EM,Schnabel JA

    更新日期:2013-09-01 00:00:00

  • A task-specific evaluation of three-dimensional image interpolation techniques.

    abstract::Image interpolation is an important operation that is widely used in medical imaging, image processing, and computer graphics. A variety of interpolation methods are available in the literature. However, their systematic evaluation is lacking. In a previous paper, we presented a framework for the task-independent comp...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.759116

    authors: Grevera GJ,Udupa JK,Miki Y

    更新日期:1999-02-01 00:00:00

  • Nonrigid image registration using conditional mutual information.

    abstract::Maximization of mutual information (MMI) is a popular similarity measure for medical image registration. Although its accuracy and robustness has been demonstrated for rigid body image registration, extending MMI to nonrigid image registration is not trivial and an active field of research. We propose conditional mutu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2021843

    authors: Loeckx D,Slagmolen P,Maes F,Vandermeulen D,Suetens P

    更新日期:2010-01-01 00:00:00

  • Algebraic reconstruction for magnetic resonance imaging under B0 inhomogeneity.

    abstract::In magnetic resonance imaging, spatial localization is usually achieved using Fourier encoding which is realized by applying a magnetic field gradient along the dimension of interest to create a linear correspondence between the resonance frequency and spatial location following the Larmor equation. In the presence of...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.712126

    authors: Kadah YM,Hu X

    更新日期:1998-06-01 00:00:00

  • Spiral-CT-based assessment of tracheal stenoses using 3-D-skeletonization.

    abstract:PURPOSE:Demonstration of a technique for three-dimensional (3-D) assessment of tracheal-stenoses, regarding site, length and degree, based on spiral computed tomography (S-CT). PATIENTS AND METHODS:S-CT scanning and automated segmentation of the laryngo-tracheal tract (LTT) was followed by the extraction of the LTT me...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/42.996344

    authors: Sorantin E,Halmai C,Erdöhelyi B,Palágyi K,Nyúl LG,Ollé K,Geiger B,Lindbichler F,Friedrich G,Kiesler K

    更新日期:2002-03-01 00:00:00

  • Digital flashing tomosynthesis: a promising technique for angiocardiographic screening.

    abstract::A system for digital flashing tomosynthesis (DFTS) consists of four ECG-gated simultaneously flashed X-ray tubes, a 14-in image intensifier, a unit for digital subtraction angiography (DSA), a PC-hosted transputer network for three-dimensional (3-D) reconstruction as well as for quantitative coronary angiography and v...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.232261

    authors: Stiel GM,Stiel LG,Klotz E,Nienaber CA

    更新日期:1993-01-01 00:00:00

  • Learning-based deformable registration of MR brain images.

    abstract::This paper presents a learning-based method for deformable registration of magnetic resonance (MR) brain images. There are two novelties in the proposed registration method. First, a set of best-scale geometric features are selected for each point in the brain, in order to facilitate correspondence detection during th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.879320

    authors: Wu G,Qi F,Shen D

    更新日期:2006-09-01 00:00:00

  • Optimal rebinning of time-of-flight PET data.

    abstract::Time-of-flight (TOF) positron emission tomography (PET) scanners offer the potential for significantly improved signal-to-noise ratio (SNR) and lesion detectability in clinical PET. However, fully 3D TOF PET image reconstruction is a challenging task due to the huge data size. One solution to this problem is to rebin ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2149537

    authors: Ahn S,Cho S,Li Q,Lin Y,Leahy RM

    更新日期:2011-10-01 00:00:00

  • Metrics for Assessing the Similarity of Microwave Breast Imaging Scans of Healthy Volunteers.

    abstract::Microwave radar imaging is promising as a complementary medical imaging modality. However, the unique nature of the images means interpretation can be difficult. As a result, it is important to understand the sources of image differences, and how much variability is inherent in the imaging system itself. To address th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2806878

    authors: Lavoie BR,Bourqui J,Fear EC,Okoniewski M

    更新日期:2018-08-01 00:00:00