Hybrid feature-based diffeomorphic registration for tumor tracking in 2-D liver ultrasound images.

Abstract:

:Real-time ultrasound image acquisition is a pivotal resource in the medical community, in spite of its limited image quality. This poses challenges to image registration methods, particularly to those driven by intensity values. We address these difficulties in a novel diffeomorphic registration technique for tumor tracking in series of 2-D liver ultrasound. Our method has two main characteristics: 1) each voxel is described by three image features: intensity, local phase, and phase congruency; 2) we compute a set of forces from either local information (Demons-type of forces), or spatial correspondences supplied by a block-matching scheme, from each image feature. A family of update deformation fields which are defined by these forces, and inform upon the local or regional contribution of each image feature are then composed to form the final transformation. The method is diffeomorphic, which ensures the invertibility of deformations. The qualitative and quantitative results yielded by both synthetic and real clinical data show the suitability of our method for the application at hand.

journal_name

IEEE Trans Med Imaging

authors

Cifor A,Risser L,Chung D,Anderson EM,Schnabel JA

doi

10.1109/TMI.2013.2262055

subject

Has Abstract

pub_date

2013-09-01 00:00:00

pages

1647-56

issue

9

eissn

0278-0062

issn

1558-254X

journal_volume

32

pub_type

杂志文章
  • Detecting Surgical Tools by Modelling Local Appearance and Global Shape.

    abstract::Detecting tools in surgical videos is an important ingredient for context-aware computer-assisted surgical systems. To this end, we present a new surgical tool detection dataset and a method for joint tool detection and pose estimation in 2d images. Our two-stage pipeline is data-driven and relaxes strong assumptions ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2450831

    authors: Bouget D,Benenson R,Omran M,Riffaud L,Schiele B,Jannin P

    更新日期:2015-12-01 00:00:00

  • Direct Parametric Reconstruction Using Anatomical Regularization for Simultaneous PET/MRI Data.

    abstract::Pharmacokinetic analysis of dynamic positron emission tomography (PET) imaging data maps the measured time activity curves to a set of model-specific pharmacokinetic parameters. Voxel-based parameter estimation via curve fitting is conventionally performed indirectly on a sequence of independently reconstructed PET im...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2427777

    authors: Loeb R,Navab N,Ziegler SI

    更新日期:2015-11-01 00:00:00

  • Simultaneous Estimation of Corneal Topography, Pachymetry, and Curvature.

    abstract::Identification of objective criteria to correctly diagnose ectatic diseases of the cornea or to detect early stages of corneal ectasia is of great interest in ophthalmology and optometry. Metrics for diagnosis typically employed are curvature maps (axial/sagittal, tangential); elevation map of the anterior surface of ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2836304

    authors: Nasrin F,Iyer RV,Mathews SM

    更新日期:2018-11-01 00:00:00

  • Analysis of the role of lead resistivity in specific absorption rate for deep brain stimulator leads at 3T MRI.

    abstract::Magnetic resonance imaging (MRI) on patients with implanted deep brain stimulators (DBSs) can be hazardous because of the antenna-effect of leads exposed to the incident radio-frequency field. This study evaluated electromagnetic field and specific absorption rate (SAR) changes as a function of lead resistivity on an ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2040624

    authors: Angelone LM,Ahveninen J,Belliveau JW,Bonmassar G

    更新日期:2010-04-01 00:00:00

  • Development and validation of a Monte Carlo simulation of photon transport in an Anger camera.

    abstract::The geometric component of the point spread function (PSF) of a gamma camera collimator can be determined analytically, and the penetration component can be calculated readily by numerical ray-tracing. A Monte Carlo simulation of photon transport which includes collimator scatter is developed. The simulation was imple...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.61758

    authors: De Vries DJ,Moore SC,Zimmerman RE,Mueller SP,Friedland B,Lanza RC

    更新日期:1990-01-01 00:00:00

  • Multi-Task Deep Model With Margin Ranking Loss for Lung Nodule Analysis.

    abstract::Lung cancer is the leading cause of cancer deaths worldwide and early diagnosis of lung nodule is of great importance for therapeutic treatment and saving lives. Automated lung nodule analysis requires both accurate lung nodule benign-malignant classification and attribute score regression. However, this is quite chal...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2934577

    authors: Liu L,Dou Q,Chen H,Qin J,Heng PA

    更新日期:2020-03-01 00:00:00

  • An Improved Method of Total Variation Superiorization Applied to Reconstruction in Proton Computed Tomography.

    abstract::Previous work has shown that total variation superiorization (TVS) improves reconstructed image quality in proton computed tomography (pCT). The structure of the TVS algorithm has evolved since then and this paper investigated if this new algorithmic structure provides additional benefits to pCT image quality. Structu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2911482

    authors: Schultze B,Censor Y,Karbasi P,Schubert KE,Schulte RW

    更新日期:2020-02-01 00:00:00

  • Lung and Pancreatic Tumor Characterization in the Deep Learning Era: Novel Supervised and Unsupervised Learning Approaches.

    abstract::Risk stratification (characterization) of tumors from radiology images can be more accurate and faster with computer-aided diagnosis (CAD) tools. Tumor characterization through such tools can also enable non-invasive cancer staging, prognosis, and foster personalized treatment planning as a part of precision medicine....

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2894349

    authors: Hussein S,Kandel P,Bolan CW,Wallace MB,Bagci U

    更新日期:2019-08-01 00:00:00

  • Numerical characterization of quasi-static ultrasound elastography for the detection of deep tissue injuries.

    abstract::Deep tissue injuries are subcutaneous regions of tissue breakdown associated with excessive mechanical pressure for extended period of time. These wounds are currently clinically undetectable in their early stages and result in severe burdens on not only the patients who suffer from them, but the health care system as...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2313082

    authors: Hamaluik K,Moussa W,Ferguson-Pell M

    更新日期:2014-07-01 00:00:00

  • A proposed taxonomy for nailfold capillaries based on their morphology.

    abstract::Certain diseases cause permanent changes to the shapes and densities of nailfold capillaries and, therefore, nailfold capillaroscopy is important as a tool for diagnosing and monitoring these diseases. The first aim of the project is to resolve differences in terminology that have developed over the years in previous ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.921482

    authors: Jones BF,Oral M,Morris CW,Ring EF

    更新日期:2001-04-01 00:00:00

  • Multi-TI Arterial Spin Labeling MRI with Variable TR and Bolus Duration for Cerebral Blood Flow and Arterial Transit Time Mapping.

    abstract::Arterial spin labeling (ASL) is an MRI perfusion imaging method from which quantitative cerebral blood flow (CBF) can be calculated. We present a multi-TI ASL method (multi-TI integrated ASL) in which variable post-labeling delays and variable TRs are used to improve the estimation of arterial transit time (ATT) and C...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2395257

    authors: Johnston ME,Lu K,Maldjian JA,Jung Y

    更新日期:2015-06-01 00:00:00

  • Geometric modeling of the human normal cerebral arterial system.

    abstract::We propose an anatomy-based approach for an efficient construction of a three-dimensional human normal cerebral arterial model from segmented and skeletonized angiographic data. The centerline-based model is used for an accurate angiographic data representation. A vascular tree is represented by tubular segments and b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2005.845041

    authors: Volkau I,Zheng W,Baimouratov R,Aziz A,Nowinski WL

    更新日期:2005-04-01 00:00:00

  • ERS transform for the automated detection of bronchial abnormalities on CT of the lungs.

    abstract::The identification of bronchi on Computed Tomography (CT) images of the lungs provides valuable clinical information in patients with suspected airways diseases including bronchiectasis, emphysema, or constrictive obliterative bronchiolitis. The automated recognition of the airways is, therefore, an important part of ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.952731

    authors: Chabat F,Hu XP,Hansell DM,Yang GZ

    更新日期:2001-09-01 00:00:00

  • Intensity-based image registration using robust correlation coefficients.

    abstract::The ordinary sample correlation coefficient is a popular similarity measure for aligning images from the same or similar modalities. However, this measure can be sensitive to the presence of "outlier" objects that appear in one image but not the other, such as surgical instruments, the patient table, etc., which can l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.835313

    authors: Kim J,Fessler JA

    更新日期:2004-11-01 00:00:00

  • Classifying mammographic lesions using computerized image analysis.

    abstract::The classification of 3 common breast lesions, fibroadenomas, cysts, and cancers, was achieved using computerized image analysis of tumor shape in conjunction with patient age. The process involved the digitization of 69 mammographic images using a video camera and a commercial frame grabber on a PC-based computer sys...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.251116

    authors: Kilday J,Palmieri F,Fox MD

    更新日期:1993-01-01 00:00:00

  • Fast joint reconstruction of dynamic R2* and field maps in functional MRI.

    abstract::Blood oxygen level dependent (BOLD) functional magnetic resonance imaging (fMRI) is conventionally done by reconstructing T(2)(*)-weighted images. However, since the images are unitless they are nonquantifiable in terms of important physiological parameters. An alternative approach is to reconstruct R(2)(*) maps which...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.917247

    authors: Olafsson VT,Noll DC,Fessler JA

    更新日期:2008-09-01 00:00:00

  • Simultaneous Photoacoustic Imaging and Cavitation Mapping in Shockwave Lithotripsy.

    abstract::Kidney stone disease is a major health problem worldwide. Shockwave lithotripsy (SWL), which uses high-energy shockwave pulses to break up kidney stones, is extensively used in clinic. However, despite its noninvasiveness, SWL can produce cavitation in vivo. The rapid expansion and violent collapse of cavitation bubbl...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2928740

    authors: Li M,Lan B,Sankin G,Zhou Y,Liu W,Xia J,Wang D,Trahey G,Zhong P,Yao J

    更新日期:2020-02-01 00:00:00

  • Practical considerations for 3-D image reconstruction using spherically symmetric volume elements.

    abstract::Spherically symmetric volume elements with smooth tapering of the values near their boundaries are alternatives to the more conventional voxels for the construction of volume images in the computer. Their use, instead of voxels, introduces additional parameters which enable the user to control the shape of the volume ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.481442

    authors: Matej S,Lewitt RM

    更新日期:1996-01-01 00:00:00

  • A novel estimation method for physiological parameters in dynamic contrast-enhanced MRI: application of a distributed parameter model using Fourier-domain calculations.

    abstract::Dynamic contrast-enhanced magnetic resonance imaging (MRI) is a promising tool in the evaluation of tumor physiology. From rapidly acquired images and a model for contrast agent pharmacokinetics, physiological parameters are derived. One pharmacokinetic model, the tissue homogeneity model, enables estimation of both b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2016212

    authors: Garpebring A,Ostlund N,Karlsson M

    更新日期:2009-09-01 00:00:00

  • Compressed Sensing Doppler Ultrasound Reconstruction Using Block Sparse Bayesian Learning.

    abstract::In this paper we propose a framework for using duplex Doppler ultrasound systems. These type of systems need to interleave the acquisition and display of a B-mode image and of the pulsed Doppler spectrogram. In a recent study (Richy , 2013), we have shown that compressed sensing-based reconstruction of Doppler signal ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2504240

    authors: Lorintiu O,Liebgott H,Friboulet D

    更新日期:2016-04-01 00:00:00

  • Displacement estimation with co-registered ultrasound for image guided neurosurgery: a quantitative in vivo porcine study.

    abstract::Brain shift during open cranial surgery presents a challenge for maintaining registration with image-guidance systems. Ultrasound (US) is a convenient intraoperative imaging modality that may be a useful tool in detecting tissue shift and updating preoperative images based on intraoperative measurements of brain defor...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.819293

    authors: Lunn KE,Paulsen KD,Roberts DW,Kennedy FE,Hartov A,West JD

    更新日期:2003-11-01 00:00:00

  • Low-Rank Atlas Image Analyses in the Presence of Pathologies.

    abstract::We present a common framework, for registering images to an atlas and for forming an unbiased atlas, that tolerates the presence of pathologies such as tumors and traumatic brain injury lesions. This common framework is particularly useful when a sufficient number of protocol-matched scans from healthy subjects cannot...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2448556

    authors: Liu X,Niethammer M,Kwitt R,Singh N,McCormick M,Aylward S

    更新日期:2015-12-01 00:00:00

  • A Generalized Correlation-Based Model for Out-of-Plane Motion Estimation in Freehand Ultrasound.

    abstract::A big challenge in sensorless image-based ultrasound tracking is in the out-of-plane motion estimation. The correlation value of a specific model of speckle known as fully developed speckle (FDS) can be used to estimate the out-of-plane displacement. In real tissue, this kind of pattern is rare and the deviation of sp...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2283969

    authors: Afsham N,Najafi M,Abolmaesumi P,Rohling R

    更新日期:2014-01-01 00:00:00

  • Spatio-temporal nonrigid registration for ultrasound cardiac motion estimation.

    abstract::We propose a new spatio-temporal elastic registration algorithm for motion reconstruction from a series of images. The specific application is to estimate displacement fields from two-dimensional ultrasound sequences of the heart. The basic idea is to find a spatio-temporal deformation field that effectively compensat...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2005.852050

    authors: Ledesma-Carbayo MJ,Kybic J,Desco M,Santos A,Sühling M,Hunziker P,Unser M

    更新日期:2005-09-01 00:00:00

  • Diffuse optical tomography enhanced by clustered sparsity for functional brain imaging.

    abstract::Diffuse optical tomography (DOT) is a noninvasive technique which measures hemodynamic changes in the tissue with near infrared light, which has been increasingly used to study brain functions. Due to the nature of light propagation in the tissue, the reconstruction problem is severely ill-posed. For linearized DOT pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2338214

    authors: Chen C,Tian F,Liu H,Huang J

    更新日期:2014-12-01 00:00:00

  • Accelerating parallel transmit array B1 mapping in high field MRI with slice undersampling and interpolation by kriging.

    abstract::Transmit arrays have been developed to mitigate the RF field inhomogeneity commonly observed in high field magnetic resonance imaging (MRI), typically above 3T. To this end, the knowledge of the RF complex-valued B1 transmit-sensitivities of each independent radiating element has become essential. This paper details a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2322440

    authors: Ferrand G,Luong M,Cloos MA,Amadon A,Wackernagel H

    更新日期:2014-08-01 00:00:00

  • Image-Based Investigation of Human in Vivo Myofibre Strain.

    abstract::Cardiac myofibre deformation is an important determinant of the mechanical function of the heart. Quantification of myofibre strain relies on 3D measurements of ventricular wall motion interpreted with respect to the tissue microstructure. In this study, we estimated in vivo myofibre strain using 3D structural and fun...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2580573

    authors: Wang VY,Casta C,Zhu YM,Cowan BR,Croisille P,Young AA,Clarysse P,Nash MP

    更新日期:2016-11-01 00:00:00

  • Evaluation of Fisher Information Matrix-Based Methods for Fast Assessment of Image Quality in Pinhole SPECT.

    abstract::The accurate determination of the local impulse response and the covariance in voxels from penalized maximum likelihood reconstructed images requires performing reconstructions from many noise realizations of the projection data. As this is usually a very time-consuming process, efficient analytical approximations bas...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2410342

    authors: Pato LR,Vandenberghe S,Vandeghinste B,Van Holen R

    更新日期:2015-09-01 00:00:00

  • A direct reconstruction algorithm for electrical impedance tomography.

    abstract::A direct (noniterative) reconstruction algorithm for electrical impedance tomography in the two-dimensional (2-D), cross-sectional geometry is reviewed. New results of a reconstruction of a numerically simulated phantom chest are presented. The algorithm is based on the mathematical uniqueness proof by A. I. Nachman [...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.800574

    authors: Mueller JL,Siltanen S,Isaacson D

    更新日期:2002-06-01 00:00:00

  • Simultaneous Quantitative Imaging of Electrical Properties and Proton Density From B1 Maps Using MRI.

    abstract::Electrical conductivity and permittivity of biological tissues are important diagnostic parameters and are useful for calculating subject-specific specific absorption rate distribution. On the other hand, water proton density also has clinical relevance for diagnosis purposes. These two kinds of tissue properties are ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2547988

    authors: Jiaen Liu,Van de Moortele PF,Xiaotong Zhang,Yicun Wang,Bin He

    更新日期:2016-09-01 00:00:00