High-Frame-Rate Echocardiography Using Coherent Compounding With Doppler-Based Motion-Compensation.

Abstract:

:High-frame-rate ultrasonography based on coherent compounding of unfocused beams can potentially transform the assessment of cardiac function. As it requires successive waves to be combined coherently, this approach is sensitive to high-velocity tissue motion. We investigated coherent compounding of tilted diverging waves, emitted from a 2.5 MHz clinical phased array transducer. To cope with high myocardial velocities, a triangle transmit sequence of diverging waves is proposed, combined with tissue Doppler imaging to perform motion compensation (MoCo). The compound sequence with integrated MoCo was adjusted from simulations and was tested in vitro and in vivo. Realistic myocardial velocities were analyzed in an in vitro spinning disk with anechoic cysts. While a 8 dB decrease (no motion versus high motion) was observed without MoCo, the contrast-to-noise ratio of the cysts was preserved with the MoCo approach. With this method, we could provide high-quality in vivo B-mode cardiac images with tissue Doppler at 250 frames per second. Although the septum and the anterior mitral leaflet were poorly apparent without MoCo, they became well perceptible and well contrasted with MoCo. The septal and lateral mitral annulus velocities determined by tissue Doppler were concordant with those measured by pulsed-wave Doppler with a clinical scanner (r(2)=0.7,y=0.9 x+0.5,N=60) . To conclude, high-contrast echo cardiographic B-mode and tissue Doppler images can be obtained with diverging beams when motion compensation is integrated in the coherent compounding process.

journal_name

IEEE Trans Med Imaging

authors

Poree J,Posada D,Hodzic A,Tournoux F,Cloutier G,Garcia D

doi

10.1109/TMI.2016.2523346

subject

Has Abstract

pub_date

2016-07-01 00:00:00

pages

1647-57

issue

7

eissn

0278-0062

issn

1558-254X

journal_volume

35

pub_type

杂志文章
  • Gap filling of 3-D microvascular networks by tensor voting.

    abstract::We present a new algorithm which merges discontinuities in 3-D images of tubular structures presenting undesirable gaps. The application of the proposed method is mainly associated to large 3-D images of microvascular networks. In order to recover the real network topology, we need to fill the gaps between the closest...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.913248

    authors: Risser L,Plouraboue F,Descombes X

    更新日期:2008-05-01 00:00:00

  • Automatic 3-D segmentation of internal structures of the head in MR images using a combination of similarity and free-form transformations: Part I, Methodology and validation on normal subjects.

    abstract::The study presented in this paper tests the hypothesis that the combination of a global similarity transformation and local free-form deformations can be used for the accurate segmentation of internal structures in MR images of the brain. To quantitatively evaluate our approach, the entire brain, the cerebellum, and t...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.811271

    authors: Dawant BM,Hartmann SL,Thirion JP,Maes F,Vandermeulen D,Demaerel P

    更新日期:1999-10-01 00:00:00

  • Border detection on digitized skin tumor images.

    abstract::A radial search technique is presented for detecting skin tumor borders in clinical dermatology images. First, it includes two rounds of radial search based on the same tumor center. The first-round search is independent, and the second-round search is knowledge-based tracking. Then a rescan with a new center is used ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.896789

    authors: Zhang Z,Stoecker WV,Moss RH

    更新日期:2000-11-01 00:00:00

  • Optimal rebinning of time-of-flight PET data.

    abstract::Time-of-flight (TOF) positron emission tomography (PET) scanners offer the potential for significantly improved signal-to-noise ratio (SNR) and lesion detectability in clinical PET. However, fully 3D TOF PET image reconstruction is a challenging task due to the huge data size. One solution to this problem is to rebin ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2149537

    authors: Ahn S,Cho S,Li Q,Lin Y,Leahy RM

    更新日期:2011-10-01 00:00:00

  • Morphometric analysis of white matter lesions in MR images: method and validation.

    abstract::The analysis of MR images is evolving from qualitative to quantitative. More and more, the question asked by clinicians is how much and where, rather than a simple statement on the presence or absence of abnormalities. The authors present a study in which the results obtained with a semiautomatic, multispectral segmen...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.363096

    authors: Zijdenbos AP,Dawant BM,Margolin RA,Palmer AC

    更新日期:1994-01-01 00:00:00

  • Quantifying the statistical impact of GRAPPA in fcMRI data with a real-valued isomorphism.

    abstract::The interpolation of missing spatial frequencies through the generalized auto-calibrating partially parallel acquisitions (GRAPPA) parallel magnetic resonance imaging (MRI) model implies a correlation is induced between the acquired and reconstructed frequency measurements. As the parallel image reconstruction algorit...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2288521

    authors: Bruce IP,Rowe DB

    更新日期:2014-02-01 00:00:00

  • Vulnerable atherosclerotic plaque elasticity reconstruction based on a segmentation-driven optimization procedure using strain measurements: theoretical framework.

    abstract::It is now recognized that prediction of the vulnerable coronary plaque rupture requires not only an accurate quantification of fibrous cap thickness and necrotic core morphology but also a precise knowledge of the mechanical properties of plaque components. Indeed, such knowledge would allow a precise evaluation of th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2012852

    authors: Le Floc'h S,Ohayon J,Tracqui P,Finet G,Gharib AM,Maurice RL,Cloutier G,Pettigrew RI

    更新日期:2009-07-01 00:00:00

  • Accelerating the nonequispaced fast Fourier transform on commodity graphics hardware.

    abstract::We present a fast parallel algorithm to compute the nonequispaced fast Fourier transform on commodity graphics hardware (the GPU). We focus particularly on a novel implementation of the convolution step in the transform as it was previously its most time consuming part. We describe the performance for two common sampl...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.909834

    authors: Sorensen TS,Schaeffter T,Noe KO,Hansen MS

    更新日期:2008-04-01 00:00:00

  • Denoising functional MR images: a comparison of wavelet denoising and Gaussian smoothing.

    abstract::We present a general wavelet-based denoising scheme for functional magnetic resonance imaging (fMRI) data and compare it to Gaussian smoothing, the traditional denoising method used in fMRI analysis. One-dimensional WaveLab thresholding routines were adapted to two-dimensional (2-D) images, and applied to 2-D wavelet ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.824234

    authors: Wink AM,Roerdink JB

    更新日期:2004-03-01 00:00:00

  • Soft tissue differentiation using multiband signatures of high resolution ultrasonic transmission tomography.

    abstract::In this paper, we are interested in soft tissue differentiation by multiband images obtained from the High-Resolution Ultrasonic Transmission Tomography (HUTT) system using a spectral target detection method based on constrained energy minimization (CEM). We have developed a new tissue differentiation method (called "...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.843179

    authors: Jeong JW,Kim TS,Shin DC,Do S,Singh M,Marmarelis VZ

    更新日期:2005-03-01 00:00:00

  • Principal Component Analysis Based Dynamic Cone Beam X-Ray Luminescence Computed Tomography: A Feasibility Study.

    abstract::Cone beam X-ray luminescence computed tomography (CB-XLCT) is a promising imaging technique in studying the physiological and pathological processes in small animals. However, the dynamic bio-distributions of probes in small animal, especially in adjacent targets are still hard to be captured directly from dynamic CB-...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2917026

    authors: Pu H,Gao P,Liu Y,Rong J,Shi F,Lu H

    更新日期:2019-12-01 00:00:00

  • Surface Reconstruction for free-space 360 degrees fluorescence molecular tomography and the effects of animal motion.

    abstract::Complete projection (360 degrees ) free-space fluorescence tomography of opaque media is poised to enable 3-D imaging through entire small animals in vivo with improved depth resolution compared to 360 degrees -projection fiber-based systems or limited-view angle systems. This approach can lead to a new generation of ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.904662

    authors: Lasser T,Soubret A,Ripoll J,Ntziachristos V

    更新日期:2008-02-01 00:00:00

  • Tomographic fluorescence imaging in tissue phantoms: a novel reconstruction algorithm and imaging geometry.

    abstract::A novel image reconstruction algorithm has been developed and demonstrated for fluorescence-enhanced frequency-domain photon migration (FDPM) tomography from measurements of area illumination with modulated excitation light and area collection of emitted fluorescence light using a gain modulated image-intensified char...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.839359

    authors: Roy R,Thompson AB,Godavarty A,Sevick-Muraca EM

    更新日期:2005-02-01 00:00:00

  • Microwave image reconstruction utilizing log-magnitude and unwrapped phase to improve high-contrast object recovery.

    abstract::Reconstructing images of large high-contrast objects with microwave methods has proved difficult. Successful images have generally been obtained by using a priori information to constrain the image reconstruction to recover the correct electromagnetic property distribution. In these situations, the measured electric f...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.913177

    authors: Meaney PM,Paulsen KD,Pogue BW,Miga MI

    更新日期:2001-02-01 00:00:00

  • DetexNet: Accurately Diagnosing Frequent and Challenging Pediatric Malignant Tumors.

    abstract::The most frequent extracranial solid tumors of childhood, named peripheral neuroblastic tumors (pNTs), are very challenging to diagnose due to their diversified categories and varying forms. Auxiliary diagnosis methods of such pediatric malignant cancers are highly needed to provide pathologists assistance and reduce ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3027547

    authors: Liu Y,Yin M,Sun S

    更新日期:2021-01-01 00:00:00

  • An improved algorithm for 2-D translational motion artifact correction.

    abstract::The quality of magnetic resonance imaging systems has improved to the point that motion is a major limitation in many examinations. Translational motion in the imaging plane causes the phase of the data to be corrupted. An algorithm using computer post-processing is proposed to correct the phase of the data, and hence...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.108589

    authors: Medley M,Yan H,Rosenfeld D

    更新日期:1991-01-01 00:00:00

  • Accuracy of the morphology enabled dipole inversion (MEDI) algorithm for quantitative susceptibility mapping in MRI.

    abstract::Determining the susceptibility distribution from the magnetic field measured in a magnetic resonance (MR) scanner is an ill-posed inverse problem, because of the presence of zeroes in the convolution kernel in the forward problem. An algorithm called morphology enabled dipole inversion (MEDI), which incorporates spati...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2182523

    authors: Liu T,Xu W,Spincemaille P,Avestimehr AS,Wang Y

    更新日期:2012-03-01 00:00:00

  • Stratified Decision Forests for Accurate Anatomical Landmark Localization in Cardiac Images.

    abstract::Accurate localization of anatomical landmarks is an important step in medical imaging, as it provides useful prior information for subsequent image analysis and acquisition methods. It is particularly useful for initialization of automatic image analysis tools (e.g. segmentation and registration) and detection of scan...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2597270

    authors: Oktay O,Bai W,Guerrero R,Rajchl M,de Marvao A,O'Regan DP,Cook SA,Heinrich MP,Glocker B,Rueckert D

    更新日期:2017-01-01 00:00:00

  • REDMAPS: reduced-dimensionality matching for prostate brachytherapy seed reconstruction.

    abstract::The success of prostate brachytherapy critically depends on delivering adequate dose to the prostate gland. Intraoperative localization of the implanted seeds provides potential for dose evaluation and optimization during therapy. A reduced-dimensionality matching algorithm for prostate brachytherapy seed reconstructi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2059709

    authors: Lee J,Labat C,Jain AK,Song DY,Burdette EC,Fichtinger G,Prince JL

    更新日期:2011-01-01 00:00:00

  • Development of a Mechanical Scanning Device With High-Frequency Ultrasound Transducer for Ultrasonic Capsule Endoscopy.

    abstract::Wireless capsule endoscopy has opened a new era by enabling remote diagnostic assessment of the gastrointestinal tract in a painless procedure. Video capsule endoscopy is currently commercially available worldwide. However, it is limited to visualization of superficial tissue. Ultrasound (US) imaging is a complementar...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2699973

    authors: Wang X,Seetohul V,Chen R,Zhang Z,Qian M,Shi Z,Yang G,Mu P,Wang C,Huang Z,Zhou Q,Zheng H,Cochran S,Qiu W

    更新日期:2017-09-01 00:00:00

  • Unwarping of unidirectionally distorted EPI images.

    abstract::Echo-planar imaging (EPI) is a fast nuclear magnetic resonance imaging (MRI) method. Unfortunately, local magnetic field inhomogeneities induced mainly by the subject's presence cause significant geometrical distortion, predominantly along the phase-encoding direction, which must be undone to allow for meaningful furt...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.836368

    authors: Kybic J,Thévenaz P,Nirkko A,Unser M

    更新日期:2000-02-01 00:00:00

  • Classification of disease subgroup and correlation with disease severity using magnetic resonance imaging whole-brain histograms: application to magnetization transfer ratios and multiple sclerosis.

    abstract::This paper presents a new approach to characterize subtle diffuse changes in multiple sclerosis (MS) using histograms derived from magnetization transfer ratio (MTR) images. Two major parts dominate our histogram analysis; 1) Classification of MTR histograms into control and MS subgroups; 2) Correlation with current d...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2002.1000256

    authors: Dehmeshki J,Barker GJ,Tofts PS

    更新日期:2002-04-01 00:00:00

  • Fast local trust region technique for diffusion tensor registration using exact reorientation and regularization.

    abstract::Diffusion tensor imaging is widely used in brain connectivity research. As more and more studies recruit large numbers of subjects, it is important to design registration methods which are not only theoretically rigorous, but also computationally efficient. However, the requirement of reorienting diffusion tensors com...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2274051

    authors: Li J,Shi Y,Tran G,Dinov I,Wang DJ,Toga A

    更新日期:2014-05-01 00:00:00

  • Unified bundling and registration of brain white matter fibers.

    abstract::Magnetic resonance diffusion tensor imaging is being widely used to reconstruct brain white matter fiber tracts. To characterize structural properties of the tracts, reconstructed fibers are often grouped into bundles that correspond to coherent anatomic structures. For further group analysis of fiber bundles, it is d...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2016337

    authors: Xu Q,Anderson AW,Gore JC,Ding Z

    更新日期:2009-09-01 00:00:00

  • Wound status evaluation using color image processing.

    abstract::An accurate diagnosis of burns and pressure ulcers in the early stages can be made by computerized image processing. This study describes a critical assessment of potential methodologies for noninvasive wound evaluation using a color imaging system. We also developed a method for quantifying histological readings and ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.552057

    authors: Hansen GL,Sparrow EM,Kokate JY,Leland KJ,Iaizzo PA

    更新日期:1997-02-01 00:00:00

  • Spatio-temporal fMRI analysis using Markov random fields.

    abstract::Functional magnetic resonance images (fMRI's) provide high-resolution datasets which allow researchers to obtain accurate delineation and sensitive detection of activation areas involved in cognitive processes. To preserve the resolution of this noninvasive technique, refined methods are required in the analysis of th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.746636

    authors: Descombes X,Kruggel F,von Cramon DY

    更新日期:1998-12-01 00:00:00

  • Fast and Accurate Rat Head Motion Tracking With Point Sources for Awake Brain PET.

    abstract::To avoid the confounding effects of anesthesia and immobilization stress in rat brain positron emission tomography (PET), motion tracking-based unrestrained awake rat brain imaging is being developed. In this paper, we propose a fast and accurate rat headmotion tracking method based on small PET point sources. PET poi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2667889

    authors: Miranda A,Staelens S,Stroobants S,Verhaeghe J

    更新日期:2017-07-01 00:00:00

  • Framing U-Net via Deep Convolutional Framelets: Application to Sparse-View CT.

    abstract::X-ray computed tomography (CT) using sparse projection views is a recent approach to reduce the radiation dose. However, due to the insufficient projection views, an analytic reconstruction approach using the filtered back projection (FBP) produces severe streaking artifacts. Recently, deep learning approaches using l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2823768

    authors: Han Y,Ye JC

    更新日期:2018-06-01 00:00:00

  • Model-based MR parameter mapping with sparsity constraints: parameter estimation and performance bounds.

    abstract::Magnetic resonance parameter mapping (e.g., T1 mapping, T2 mapping, T*2 mapping) is a valuable tool for tissue characterization. However, its practical utility has been limited due to long data acquisition time. This paper addresses this problem with a new model-based parameter mapping method. The proposed method util...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2322815

    authors: Zhao B,Lam F,Liang ZP

    更新日期:2014-09-01 00:00:00

  • Novel EIS postprocessing algorithm for breast cancer diagnosis.

    abstract::A new postprocessing algorithm was developed for the diagnosis of breast cancer using electrical impedance scanning. This algorithm automatically recognizes bright focal spots in the conductivity map of the breast. Moreover, this algorithm discriminates between malignant and benign/normal tissues using two main predic...

    journal_title:IEEE transactions on medical imaging

    pub_type: 信件

    doi:10.1109/TMI.2002.800605

    authors: Glickman YA,Filo O,Nachaliel U,Lenington S,Amin-Spector S,Ginor R

    更新日期:2002-06-01 00:00:00