Shortest path refinement for motion estimation from tagged MR images.

Abstract:

:Magnetic resonance tagging makes it possible to measure the motion of tissues such as muscles in the heart and tongue. The harmonic phase (HARP) method largely automates the process of tracking points within tagged MR images, permitting many motion properties to be computed. However, HARP tracking can yield erroneous motion estimates due to 1) large deformations between image frames, 2) through-plane motion, and 3) tissue boundaries. Methods that incorporate the spatial continuity of motion--so-called refinement or flood-filling methods--have previously been reported to reduce tracking errors. This paper presents a new refinement method based on shortest path computations. The method uses a graph representation of the image and seeks an optimal tracking order from a specified seed to each point in the image by solving a single source shortest path problem. This minimizes the potential errors for those path dependent solutions that are found in other refinement methods. In addition to this, tracking in the presence of through-plane motion is improved by introducing synthetic tags at the reference time (when the tissue is not deformed). Experimental results on both tongue and cardiac images show that the proposed method can track the whole tissue more robustly and is also computationally efficient.

journal_name

IEEE Trans Med Imaging

authors

Liu X,Prince JL

doi

10.1109/TMI.2010.2045509

subject

Has Abstract

pub_date

2010-08-01 00:00:00

pages

1560-72

issue

8

eissn

0278-0062

issn

1558-254X

journal_volume

29

pub_type

杂志文章
  • 4-D Reconstruction With Respiratory Correction for Gated Myocardial Perfusion SPECT.

    abstract::Cardiac single photon emission computed tomography (SPECT) images are known to suffer from both cardiac and respiratory motion blur. In this paper, we investigate a 4-D reconstruction approach to suppress the effect of respiratory motion in gated cardiac SPECT imaging. In this approach, the sequence of cardiac gated i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2690819

    authors: Qi W,Yang Y,Song C,Wernick MN,Pretorius PH,King MA

    更新日期:2017-08-01 00:00:00

  • Estimating CT Image From MRI Data Using Structured Random Forest and Auto-Context Model.

    abstract::Computed tomography (CT) imaging is an essential tool in various clinical diagnoses and radiotherapy treatment planning. Since CT image intensities are directly related to positron emission tomography (PET) attenuation coefficients, they are indispensable for attenuation correction (AC) of the PET images. However, due...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2461533

    authors: Huynh T,Gao Y,Kang J,Wang L,Zhang P,Lian J,Shen D,Alzheimer's Disease Neuroimaging Initiative.

    更新日期:2016-01-01 00:00:00

  • Quantifying the statistical impact of GRAPPA in fcMRI data with a real-valued isomorphism.

    abstract::The interpolation of missing spatial frequencies through the generalized auto-calibrating partially parallel acquisitions (GRAPPA) parallel magnetic resonance imaging (MRI) model implies a correlation is induced between the acquired and reconstructed frequency measurements. As the parallel image reconstruction algorit...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2288521

    authors: Bruce IP,Rowe DB

    更新日期:2014-02-01 00:00:00

  • Adaptive reproducing kernel particle method for extraction of the cortical surface.

    abstract::We propose a novel adaptive approach based on the Reproducing Kernel Particle Method (RKPM) to extract the cortical surfaces of the brain from three-dimensional (3-D) magnetic resonance images (MRIs). To formulate the discrete equations of the deformable model, a flexible particle shape function is employed in the Gal...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.873614

    authors: Xu M,Thompson PM,Toga AW

    更新日期:2006-06-01 00:00:00

  • Simulation of the expected performance of a seamless scanner for brain PET based on highly pixelated CdTe detectors.

    abstract::The aim of this work is the evaluation of the design for a nonconventional PET scanner, the voxel imaging PET (VIP), based on pixelated room-temperature CdTe detectors yielding a true 3-D impact point with a density of 450 channels/cm(3), for a total 6 336 000 channels in a seamless ring shaped volume. The system is s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2284657

    authors: Mikhaylova E,De Lorenzo G,Chmeissani M,Kolstein M,Cañadas M,Arce P,Calderón Y,Uzun D,Ariño G,Macias-Montero JG,Martinez R,Puigdengoles C,Cabruja E

    更新日期:2014-02-01 00:00:00

  • Electrical impedance tomography using induced currents.

    abstract::The mathematical basis of a new imaging modality, induced current electrical impedance tomography (EIT), is investigated, The ultimate aim of this technique is the reconstruction of conductivity distribution of the human body, from voltage measurements made between electrodes placed on the surface, when currents are i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.293927

    authors: Gencer NG,Kuzuoglu M,Ider YZ

    更新日期:1994-01-01 00:00:00

  • An image-guided planning system for endosseous oral implants.

    abstract::A preoperative planning system for oral implant surgery was developed which takes as input computed tomographies (CT's) of the jaws. Two-dimensional (2-D) reslices of these axial CT slices orthogonal to a curve following the jaw arch are computed and shown together with three-dimensional (3-D) surface rendered models ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.736056

    authors: Verstreken K,Van Cleynenbreugel J,Martens K,Marchal G,van Steenberghe D,Suetens P

    更新日期:1998-10-01 00:00:00

  • Investigation of Axial and Angular Sampling in Multi-Detector Pinhole-SPECT Brain Imaging.

    abstract::We designed a dedicated multi-detector multi-pinhole brain SPECT scanner to generate images of higher quality compared to general-purpose systems. The system, AdaptiSPECT-C, is intended to adapt its sensitivity-resolution trade-off by varying its aperture configurations allowing both high-sensitivity dynamic and high-...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3015079

    authors: Zeraatkar N,Kalluri KS,Auer B,Konik A,Fromme TJ,Furenlid LR,Kuo PH,King MA

    更新日期:2020-12-01 00:00:00

  • Diffuse optical tomography enhanced by clustered sparsity for functional brain imaging.

    abstract::Diffuse optical tomography (DOT) is a noninvasive technique which measures hemodynamic changes in the tissue with near infrared light, which has been increasingly used to study brain functions. Due to the nature of light propagation in the tissue, the reconstruction problem is severely ill-posed. For linearized DOT pr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2338214

    authors: Chen C,Tian F,Liu H,Huang J

    更新日期:2014-12-01 00:00:00

  • Regularization designs for uniform spatial resolution and noise properties in statistical image reconstruction for 3-D X-ray CT.

    abstract::Statistical image reconstruction methods for X-ray computed tomography (CT) provide improved spatial resolution and noise properties over conventional filtered back-projection (FBP) reconstruction, along with other potential advantages such as reduced patient dose and artifacts. Conventional regularized image reconstr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2365179

    authors: Cho JH,Fessler JA

    更新日期:2015-02-01 00:00:00

  • Accurate event-driven motion compensation in high-resolution PET incorporating scattered and random events.

    abstract::With continuing improvements in spatial resolution of positron emission tomography (PET) scanners, small patient movements during PET imaging become a significant source of resolution degradation. This work develops and investigates a comprehensive formalism for accurate motion-compensated reconstruction which at the ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2008.917248

    authors: Rahmim A,Dinelle K,Cheng JC,Shilov MA,Segars WP,Lidstone SC,Blinder S,Rousset OG,Vajihollahi H,Tsui BM,Wong DF,Sossi V

    更新日期:2008-08-01 00:00:00

  • A novel estimation method for physiological parameters in dynamic contrast-enhanced MRI: application of a distributed parameter model using Fourier-domain calculations.

    abstract::Dynamic contrast-enhanced magnetic resonance imaging (MRI) is a promising tool in the evaluation of tumor physiology. From rapidly acquired images and a model for contrast agent pharmacokinetics, physiological parameters are derived. One pharmacokinetic model, the tissue homogeneity model, enables estimation of both b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2016212

    authors: Garpebring A,Ostlund N,Karlsson M

    更新日期:2009-09-01 00:00:00

  • Improving Registration Robustness for Image-Guided Liver Surgery in a Novel Human-to-Phantom Data Framework.

    abstract::In open image-guided liver surgery (IGLS), a sparse representation of the intraoperative organ surface can be acquired to drive image-to-physical registration. We hypothesize that uncharacterized error induced by variation in the collection patterns of organ surface data limits the accuracy and robustness of an IGLS r...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2668842

    authors: Collins JA,Weis JA,Heiselman JS,Clements LW,Simpson AL,Jarnagin WR,Miga MI

    更新日期:2017-07-01 00:00:00

  • High-Frame-Rate Echocardiography Using Coherent Compounding With Doppler-Based Motion-Compensation.

    abstract::High-frame-rate ultrasonography based on coherent compounding of unfocused beams can potentially transform the assessment of cardiac function. As it requires successive waves to be combined coherently, this approach is sensitive to high-velocity tissue motion. We investigated coherent compounding of tilted diverging w...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2523346

    authors: Poree J,Posada D,Hodzic A,Tournoux F,Cloutier G,Garcia D

    更新日期:2016-07-01 00:00:00

  • Imaging the distribution of magnetic nanoparticles with ultrasound.

    abstract::Magnetic nanoparticles can be caused to oscillate under the influence of an incident ultrasonic wave. If the particles are momentarily aligned with a magnetizing pulse creating a macroscopic magnetization, this oscillation will result in a time-varying magnetic moment which should be detectable as an induced voltage i...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2007.895476

    authors: Norton SJ,Vo-Dinh T

    更新日期:2007-05-01 00:00:00

  • Numerical characterization of quasi-static ultrasound elastography for the detection of deep tissue injuries.

    abstract::Deep tissue injuries are subcutaneous regions of tissue breakdown associated with excessive mechanical pressure for extended period of time. These wounds are currently clinically undetectable in their early stages and result in severe burdens on not only the patients who suffer from them, but the health care system as...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2313082

    authors: Hamaluik K,Moussa W,Ferguson-Pell M

    更新日期:2014-07-01 00:00:00

  • Reconstruction of dielectric permittivity distributions in arbitrary 2-D inhomogeneous biological bodies by a multiview microwave numerical method.

    abstract::A numerical method for microwave imaging of two-dimensional inhomogeneous biological bodies illuminated by TM waves is presented. It is a spatial-domain multiview approach which makes use of the moment method to discretize the integral-equation formulation of inverse scattering. A pseudoinversion technique is applied ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.232251

    authors: Caorsi S,Gragnani GL,Pastorino M

    更新日期:1993-01-01 00:00:00

  • Restoration of retinal images obtained through cataracts.

    abstract::An optical model for imaging the retina through cataracts has been developed. The images are treated as sample functions of stochastic processes. On the basis of the model a homomorphic Weiner filter can be designed that will optimally restore the cataractous image (in the mean-square-error sense). The design of the f...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.41493

    authors: Peli E,Peli T

    更新日期:1989-01-01 00:00:00

  • Robust super-resolution volume reconstruction from slice acquisitions: application to fetal brain MRI.

    abstract::Fast magnetic resonance imaging slice acquisition techniques such as single shot fast spin echo are routinely used in the presence of uncontrollable motion. These techniques are widely used for fetal magnetic resonance imaging (MRI) and MRI of moving subjects and organs. Although high-quality slices are frequently acq...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2051680

    authors: Gholipour A,Estroff JA,Warfield SK

    更新日期:2010-10-01 00:00:00

  • Ex Vivo and In Vivo Monitoring and Characterization of Thermal Lesions by High-Intensity Focused Ultrasound and Microwave Ablation Using Ultrasonic Nakagami Imaging.

    abstract::The feasibility of ultrasonic Nakagami imaging to evaluate thermal lesions by high-intensity focused ultrasound and microwave ablation was explored in ex vivo and in vivo liver models. Dynamic changes of the ultrasonic Nakagami parameter in thermal lesions were calculated, and ultrasonic B-mode and Nakagami images wer...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2829934

    authors: Zhang S,Shang S,Han Y,Gu C,Wu S,Liu S,Niu G,Bouakaz A,Wan M

    更新日期:2018-07-01 00:00:00

  • Stratified Decision Forests for Accurate Anatomical Landmark Localization in Cardiac Images.

    abstract::Accurate localization of anatomical landmarks is an important step in medical imaging, as it provides useful prior information for subsequent image analysis and acquisition methods. It is particularly useful for initialization of automatic image analysis tools (e.g. segmentation and registration) and detection of scan...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2597270

    authors: Oktay O,Bai W,Guerrero R,Rajchl M,de Marvao A,O'Regan DP,Cook SA,Heinrich MP,Glocker B,Rueckert D

    更新日期:2017-01-01 00:00:00

  • Vulnerable atherosclerotic plaque elasticity reconstruction based on a segmentation-driven optimization procedure using strain measurements: theoretical framework.

    abstract::It is now recognized that prediction of the vulnerable coronary plaque rupture requires not only an accurate quantification of fibrous cap thickness and necrotic core morphology but also a precise knowledge of the mechanical properties of plaque components. Indeed, such knowledge would allow a precise evaluation of th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2009.2012852

    authors: Le Floc'h S,Ohayon J,Tracqui P,Finet G,Gharib AM,Maurice RL,Cloutier G,Pettigrew RI

    更新日期:2009-07-01 00:00:00

  • An investigation of methods of pileup rejection for 2-D array detectors employed in high resolution PET.

    abstract::Two methods of rejecting pileup events in 2-D array detectors used in positron emission tomography (PET) are investigated. Since the methods are based on different physical properties, they were investigated separately and in combination. Method one is based on the fact that valid events in the 2-D array detector occu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.79481

    authors: Germano G,Hoffman EJ

    更新日期:1991-01-01 00:00:00

  • High-Permittivity Pad Design for Dielectric Shimming in Magnetic Resonance Imaging Using Projection-Based Model Reduction and a Nonlinear Optimization Scheme.

    abstract::Inhomogeneities in the transmit radio frequency magnetic field ( ) reduce the quality of magnetic resonance (MR) images. This quality can be improved by using high-permittivity pads that tailor the fields. The design of an optimal pad is application-specific and not straightforward and would therefore benefit from a s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2791179

    authors: van Gemert JHF,Brink WM,Webb AG,Remis RF

    更新日期:2018-04-01 00:00:00

  • Sparse-view spectral CT reconstruction using spectral patch-based low-rank penalty.

    abstract::Spectral computed tomography (CT) is a promising technique with the potential for improving lesion detection, tissue characterization, and material decomposition. In this paper, we are interested in kVp switching-based spectral CT that alternates distinct kVp X-ray transmissions during gantry rotation. This system can...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2380993

    authors: Kim K,Ye JC,Worstell W,Ouyang J,Rakvongthai Y,El Fakhri G,Li Q

    更新日期:2015-03-01 00:00:00

  • Automated detection of prostatic adenocarcinoma from high-resolution ex vivo MRI.

    abstract::Prostatic adenocarcinoma is the most commonly occurring cancer among men in the United States, second only to skin cancer. Currently, the only definitive method to ascertain the presence of prostatic cancer is by trans-rectal ultrasound (TRUS) directed biopsy. Owing to the poor image quality of ultrasound, the accurac...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2005.859208

    authors: Madabhushi A,Feldman MD,Metaxas DN,Tomaszeweski J,Chute D

    更新日期:2005-12-01 00:00:00

  • Improved Contrast-Enhanced Power Doppler Using a Coherence-Based Estimator.

    abstract::While plane-wave imaging can improve the performance of power Doppler by enabling much longer ensembles than systems using focused beams, the long-ensemble averaging of the zero-lag autocorrelation R(0) estimates does not directly decrease the mean noise level, but only decreases its variance. Spatial variation of the...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2699672

    authors: Tremblay-Darveau C,Bar-Zion A,Williams R,Sheeran PS,Milot L,Loupas T,Adam D,Bruce M,Burns PN

    更新日期:2017-09-01 00:00:00

  • Bidirectional Mapping-Based Domain Adaptation for Nucleus Detection in Cross-Modality Microscopy Images.

    abstract::Cell or nucleus detection is a fundamental task in microscopy image analysis and has recently achieved state-of-the-art performance by using deep neural networks. However, training supervised deep models such as convolutional neural networks (CNNs) usually requires sufficient annotated image data, which is prohibitive...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3042789

    authors: Xing F,Cornish TC,Bennett TD,Ghosh D

    更新日期:2020-12-07 00:00:00

  • Learning-based deformable registration of MR brain images.

    abstract::This paper presents a learning-based method for deformable registration of magnetic resonance (MR) brain images. There are two novelties in the proposed registration method. First, a set of best-scale geometric features are selected for each point in the brain, in order to facilitate correspondence detection during th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.879320

    authors: Wu G,Qi F,Shen D

    更新日期:2006-09-01 00:00:00

  • Prior-Attention Residual Learning for More Discriminative COVID-19 Screening in CT Images.

    abstract::We propose a conceptually simple framework for fast COVID-19 screening in 3D chest CT images. The framework can efficiently predict whether or not a CT scan contains pneumonia while simultaneously identifying pneumonia types between COVID-19 and Interstitial Lung Disease (ILD) caused by other viruses. In the proposed ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2994908

    authors: Wang J,Bao Y,Wen Y,Lu H,Luo H,Xiang Y,Li X,Liu C,Qian D

    更新日期:2020-08-01 00:00:00