Optimizing rod window width in positron emission tomography.

Abstract:

:A technique determines the optimal window width for orbiting rod transmission studies in positron emission tomography (PET). Windowing reduces noise in orbiting rod transmission studies. Lines-of-response (LOR) which intersect the rods generate primarily true coincidence events. LOR which pass far from the rods generate random and scatter events. Since the angular position of the orbiting rods is known in real-time, LOR which produce mostly noise are gated off. When optimally determined, the rod window width maximizes the noise equivalent counts (NEC) collected in the transmission study. Transaxial rod projection profiles of trues, randoms, and scatter produce NEC versus window width plots. For the ECAT EXACT line of PET systems and a 20-cm water cylinder, optimal is five LOR wide.

journal_name

IEEE Trans Med Imaging

authors

Jones WF,Digby WM,Luk WK,Casey ME,Byars LG

doi

10.1109/42.387708

subject

Has Abstract

pub_date

1995-01-01 00:00:00

pages

266-70

issue

2

eissn

0278-0062

issn

1558-254X

journal_volume

14

pub_type

杂志文章
  • Computer-aided stereotactic functional neurosurgery enhanced by the use of the multiple brain atlas database.

    abstract::This paper introduces a computer-aided atlas-based functional neurosurgery methodology and describes NeuroPlanner, a software system which supports it. NeuroPlanner provides four groups of functions: 1) data-related for data reading, interpolation, reformatting, and image processing; 2) atlas-related for multiple atla...

    journal_title:IEEE transactions on medical imaging

    pub_type: 信件

    doi:10.1109/42.832961

    authors: Nowinski WL,Yang GL,Yeo TT

    更新日期:2000-01-01 00:00:00

  • A Kernel-Based Low-Rank (KLR) Model for Low-Dimensional Manifold Recovery in Highly Accelerated Dynamic MRI.

    abstract::While many low rank and sparsity-based approaches have been developed for accelerated dynamic magnetic resonance imaging (dMRI), they all use low rankness or sparsity in input space, overlooking the intrinsic nonlinear correlation in most dMRI data. In this paper, we propose a kernel-based framework to allow nonlinear...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2723871

    authors: Nakarmi U,Wang Y,Lyu J,Liang D,Ying L

    更新日期:2017-11-01 00:00:00

  • Accuracy of the morphology enabled dipole inversion (MEDI) algorithm for quantitative susceptibility mapping in MRI.

    abstract::Determining the susceptibility distribution from the magnetic field measured in a magnetic resonance (MR) scanner is an ill-posed inverse problem, because of the presence of zeroes in the convolution kernel in the forward problem. An algorithm called morphology enabled dipole inversion (MEDI), which incorporates spati...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2182523

    authors: Liu T,Xu W,Spincemaille P,Avestimehr AS,Wang Y

    更新日期:2012-03-01 00:00:00

  • Compressed Sensing Reconstruction of 3D Ultrasound Data Using Dictionary Learning and Line-Wise Subsampling.

    abstract::In this paper we present a compressed sensing (CS) method adapted to 3D ultrasound imaging (US). In contrast to previous work, we propose a new approach based on the use of learned overcomplete dictionaries that allow for much sparser representations of the signals since they are optimized for a particular class of im...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2442154

    authors: Lorintiu O,Liebgott H,Alessandrini M,Bernard O,Friboulet D

    更新日期:2015-12-01 00:00:00

  • A comprehensive cardiac motion estimation framework using both untagged and 3-D tagged MR images based on nonrigid registration.

    abstract::In this paper, we present a novel technique based on nonrigid image registration for myocardial motion estimation using both untagged and 3-D tagged MR images. The novel aspect of our technique is its simultaneous usage of complementary information from both untagged and 3-D tagged MR images. To estimate the motion wi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2188104

    authors: Shi W,Zhuang X,Wang H,Duckett S,Luong DV,Tobon-Gomez C,Tung K,Edwards PJ,Rhode KS,Razavi RS,Ourselin S,Rueckert D

    更新日期:2012-06-01 00:00:00

  • Learning Geodesic Active Contours for Embedding Object Global Information in Segmentation CNNs.

    abstract::Most existing CNNs-based segmentation methods rely on local appearances learned on the regular image grid, without consideration of the object global information. This article aims to embed the object global geometric information into a learning framework via the classical geodesic active contours (GAC). We propose a ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3022693

    authors: Ma J,He J,Yang X

    更新日期:2021-01-01 00:00:00

  • Electrical impedance spectroscopy of the breast: clinical imaging results in 26 subjects.

    abstract::Electrical impedance spectroscopy (EIS) is a potential, noninvasive technique to image women for breast cancer. Studies have shown characteristic frequency dispersions in the electrical conductivity and permittivity of malignant versus normal tissue. Using a multifrequency EIS system, we imaged the breasts of 26 women...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/tmi.2002.800606

    authors: Kerner TE,Paulsen KD,Hartov A,Soho SK,Poplack SP

    更新日期:2002-06-01 00:00:00

  • Soft tissue differentiation using multiband signatures of high resolution ultrasonic transmission tomography.

    abstract::In this paper, we are interested in soft tissue differentiation by multiband images obtained from the High-Resolution Ultrasonic Transmission Tomography (HUTT) system using a spectral target detection method based on constrained energy minimization (CEM). We have developed a new tissue differentiation method (called "...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.843179

    authors: Jeong JW,Kim TS,Shin DC,Do S,Singh M,Marmarelis VZ

    更新日期:2005-03-01 00:00:00

  • A penalized-likelihood image reconstruction method for emission tomography, compared to postsmoothed maximum-likelihood with matched spatial resolution.

    abstract::Regularization is desirable for image reconstruction in emission tomography. A powerful regularization method is the penalized-likelihood (PL) reconstruction algorithm (or equivalently, maximum a posteriori reconstruction), where the sum of the likelihood and a noise suppressing penalty term (or Bayesian prior) is opt...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.816960

    authors: Nuyts J,Fessler JA

    更新日期:2003-09-01 00:00:00

  • Detailed Evaluation of Five 3D Speckle Tracking Algorithms Using Synthetic Echocardiographic Recordings.

    abstract::A plethora of techniques for cardiac deformation imaging with 3D ultrasound, typically referred to as 3D speckle tracking techniques, are available from academia and industry. Although the benefits of single methods over alternative ones have been reported in separate publications, the intrinsic differences in the dat...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2016.2537848

    authors: Alessandrini M,Heyde B,Queiros S,Cygan S,Zontak M,Somphone O,Bernard O,Sermesant M,Delingette H,Barbosa D,De Craene M,ODonnell M,Dhooge J

    更新日期:2016-08-01 00:00:00

  • Joint Optic Disc and Cup Segmentation Based on Multi-Label Deep Network and Polar Transformation.

    abstract::Glaucoma is a chronic eye disease that leads to irreversible vision loss. The cup to disc ratio (CDR) plays an important role in the screening and diagnosis of glaucoma. Thus, the accurate and automatic segmentation of optic disc (OD) and optic cup (OC) from fundus images is a fundamental task. Most existing methods s...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2791488

    authors: Fu H,Cheng J,Xu Y,Wong DWK,Liu J,Cao X

    更新日期:2018-07-01 00:00:00

  • Principal Component Analysis Based Dynamic Cone Beam X-Ray Luminescence Computed Tomography: A Feasibility Study.

    abstract::Cone beam X-ray luminescence computed tomography (CB-XLCT) is a promising imaging technique in studying the physiological and pathological processes in small animals. However, the dynamic bio-distributions of probes in small animal, especially in adjacent targets are still hard to be captured directly from dynamic CB-...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2917026

    authors: Pu H,Gao P,Liu Y,Rong J,Shi F,Lu H

    更新日期:2019-12-01 00:00:00

  • Simultaneous MR-compatible emission and transmission imaging for PET using time-of-flight information.

    abstract::Quantitative positron emission tomography (PET) imaging relies on accurate attenuation correction. Predicting attenuation values from magnetic resonance (MR) images is difficult because MR signals are related to proton density and relaxation properties of tissues. Here, we propose a method to derive the attenuation ma...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2198831

    authors: Mollet P,Keereman V,Clementel E,Vandenberghe S

    更新日期:2012-09-01 00:00:00

  • Anti-aliasing weighting functions for single-slice helical CT.

    abstract::Spatially variant longitudinal aliasing plagues most volumes reconstructed from single-slice helical computed tomography data, and its presence can degrade resolution and distort image structures. We have recently developed a Fourier-based approach to longitudinal interpolation in helical computed tomography that can,...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2002.803104

    authors: La Rivière PJ,Pan X

    更新日期:2002-08-01 00:00:00

  • Simulation and Synthesis in Medical Imaging.

    abstract::This editorial introduces the Special Issue on Simulation and Synthesis in Medical Imaging. In this editorial, we define so-far ambiguous terms of simulation and synthesis in medical imaging. We also briefly discuss the synergistic importance of mechanistic (hypothesis-driven) and phenomenological (data-driven) models...

    journal_title:IEEE transactions on medical imaging

    pub_type: 社论

    doi:10.1109/TMI.2018.2800298

    authors: Frangi AF,Tsaftaris SA,Prince JL

    更新日期:2018-03-01 00:00:00

  • Robust Energy Calibration Technique for Photon Counting Spectral Detectors.

    abstract::This paper describes the implementation of a novel and robust threshold energy calibration method for photon counting detectors using polychromatic X-ray tubes. Methods often used for such energy calibration may require re-orientation of the detector or introduce calibration errors that are flux and acquisition time-d...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2875932

    authors: Vespucci S,Park CS,Torrico R,Das M

    更新日期:2019-04-01 00:00:00

  • Segmentation of prostate boundaries from ultrasound images using statistical shape model.

    abstract::This paper presents a statistical shape model for the automatic prostate segmentation in transrectal ultrasound images. A Gabor filter bank is first used to characterize the prostate boundaries in ultrasound images in both multiple scales and multiple orientations. The Gabor features are further reconstructed to be in...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2003.809057

    authors: Shen D,Zhan Y,Davatzikos C

    更新日期:2003-04-01 00:00:00

  • Automatic, Age Consistent Reconstruction of the Corpus Callosum Guided by Coherency From In Utero Diffusion-Weighted MRI.

    abstract::Reconstruction of white matter connectivity in the fetal brain from in utero diffusion-weighted magnetic resonance imaging (MRI) faces many challenges, including subject motion, small anatomical scale, and limited image resolution and signal. These issues are compounded by the need to track significant changes in stru...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2932681

    authors: Hunt D,Dighe M,Gatenby C,Studholme C

    更新日期:2020-03-01 00:00:00

  • Lung 4D CT Image Registration Based on High-Order Markov Random Field.

    abstract::To solve the problem that traditional image registration methods based on continuous optimization for large motion lung 4D CT image sequences are easy to fall into local optimal solutions and lead to serious misregistration, a novel image registration method based on high-order Markov Random Field (MRF) is proposed. B...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2937458

    authors: Xue P,Dong E,Ji H

    更新日期:2020-04-01 00:00:00

  • Segmentation of cardiac cine MR images for extraction of right and left ventricular chambers.

    abstract::A two-stage algorithm for extraction of the ventricular chambers (endocardial surfaces) in flow-enhanced magnetic resonance images is described. In the first stage, the approximate locations and sizes of the endocardial surfaces are determined by intensity thresholding. In the second stage, points on each approximated...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.370402

    authors: Goshtasby A,Turner DA

    更新日期:1995-01-01 00:00:00

  • Ultrafast Doppler imaging of blood flow dynamics in the myocardium.

    abstract::Imaging intramyocardial vascular flows in real-time could strongly help to achieve better diagnostic of cardiovascular diseases. To date, no standard imaging modality allows describing accurately myocardial blood flow dynamics with good spatial and temporal resolution. We recently introduced a novel ultrasonic Doppler...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2203316

    authors: Osmanski BF,Pernot M,Montaldo G,Bel A,Messas E,Tanter M

    更新日期:2012-08-01 00:00:00

  • MRF-based deformable registration and ventilation estimation of lung CT.

    abstract::Deformable image registration is an important tool in medical image analysis. In the case of lung computed tomography (CT) registration there are three major challenges: large motion of small features, sliding motions between organs, and changing image contrast due to compression. Recently, Markov random field (MRF)-b...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2246577

    authors: Heinrich MP,Jenkinson M,Brady M,Schnabel JA

    更新日期:2013-07-01 00:00:00

  • Regularization designs for uniform spatial resolution and noise properties in statistical image reconstruction for 3-D X-ray CT.

    abstract::Statistical image reconstruction methods for X-ray computed tomography (CT) provide improved spatial resolution and noise properties over conventional filtered back-projection (FBP) reconstruction, along with other potential advantages such as reduced patient dose and artifacts. Conventional regularized image reconstr...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2365179

    authors: Cho JH,Fessler JA

    更新日期:2015-02-01 00:00:00

  • GPU-based real-time volumetric ultrasound image reconstruction for a ring array.

    abstract::Synthetic phased array (SPA) beamforming with Hadamard coding and aperture weighting is an optimal option for real-time volumetric imaging with a ring array, a particularly attractive geometry in intracardiac and intravascular applications. However, the imaging frame rate of this method is limited by the immense compu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2253117

    authors: Choe JW,Nikoozadeh A,Oralkan O,Khuri-Yakub BT

    更新日期:2013-07-01 00:00:00

  • Multifrequency electrical impedance tomography using spectral constraints.

    abstract::Multifrequency electrical impedance tomography (MFEIT) exploits the dependence of tissue impedance on frequency to recover an image of conductivity. MFEIT could provide emergency diagnosis of pathologies such as acute stroke, brain injury and breast cancer. We present a method for performing MFEIT using spectral const...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2013.2284966

    authors: Malone E,Sato Dos Santos G,Holder D,Arridge S

    更新日期:2014-02-01 00:00:00

  • Optimization of MRI Gradient Coils With Explicit Peripheral Nerve Stimulation Constraints.

    abstract::Peripheral Nerve Stimulation (PNS) limits the acquisition rate of Magnetic Resonance Imaging data for fast sequences employing powerful gradient systems. The PNS characteristics are currently assessed after the coil design phase in experimental stimulation studies using constructed coil prototypes. This makes it diffi...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.3023329

    authors: Davids M,Guerin B,Klein V,Wald LL

    更新日期:2021-01-01 00:00:00

  • The detection and quantification of retinopathy using digital angiograms.

    abstract::An algorithm is presented for the analysis and quantification of the vascular structures of the human retina. Information about retinal blood vessel morphology is used in grading the severity and progression of a number of diseases. These disease processes are typically followed over relatively long time courses, and ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.363106

    authors: Zhou L,Rzeszotarski MS,Singerman LJ,Chokreff JM

    更新日期:1994-01-01 00:00:00

  • An investigation of methods of pileup rejection for 2-D array detectors employed in high resolution PET.

    abstract::Two methods of rejecting pileup events in 2-D array detectors used in positron emission tomography (PET) are investigated. Since the methods are based on different physical properties, they were investigated separately and in combination. Method one is based on the fact that valid events in the 2-D array detector occu...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.79481

    authors: Germano G,Hoffman EJ

    更新日期:1991-01-01 00:00:00

  • Deformable registration of glioma images using EM algorithm and diffusion reaction modeling.

    abstract::This paper investigates the problem of atlas registration of brain images with gliomas. Multiparametric imaging modalities (T1, T1-CE, T2, and FLAIR) are first utilized for segmentations of different tissues, and to compute the posterior probability map (PBM) of membership to each tissue class, using supervised learni...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2078833

    authors: Gooya A,Biros G,Davatzikos C

    更新日期:2011-02-01 00:00:00

  • Intensity-based image registration using robust correlation coefficients.

    abstract::The ordinary sample correlation coefficient is a popular similarity measure for aligning images from the same or similar modalities. However, this measure can be sensitive to the presence of "outlier" objects that appear in one image but not the other, such as surgical instruments, the patient table, etc., which can l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.835313

    authors: Kim J,Fessler JA

    更新日期:2004-11-01 00:00:00