Post-implantation impedance spectroscopy of subretinal micro-electrode arrays, OCT imaging and numerical simulation: towards a more precise neuroprosthesis monitoring tool.

Abstract:

OBJECTIVE:Previous studies have shown that single-frequency impedance measurements could provide useful information about the distance between the neuroprosthesis and the retina. This work investigates the use of impedance spectroscopy in monitoring subretinal implantations of flexible micro-electrode arrays and focuses on determining what is governing impedance profiles. APPROACH:In this study, we use impedance spectroscopy together with optical coherence tomography imaging and numerical simulation to quantitatively evaluate the constituent elements of measured impedance. MAIN RESULTS:We show the existence of specific impedance spectrum profiles for retinal detection and retinal detachment that are in good agreement with numerical simulations. These simulations suggest that monopolar impedance is mainly influenced by the subretinal space. Numerical simulations also provide a quantitative prediction of the lateral spread of current density in the vicinity of the measuring contact as a function of retina-electrode distance. SIGNIFICANCE:In general, our results point to the need for scanning a large frequency range for impedance measurements since capacitive and resistive regimes are strongly dependent on retina-electrode proximity. We believe that these results will contribute to a better understanding of electrical stimulation in neuroprostheses and ultimately improve their efficiency.

journal_name

J Neural Eng

authors

Pham P,Roux S,Matonti F,Dupont F,Agache V,Chavane F

doi

10.1088/1741-2560/10/4/046002

subject

Has Abstract

pub_date

2013-08-01 00:00:00

pages

046002

issue

4

eissn

1741-2560

issn

1741-2552

journal_volume

10

pub_type

杂志文章
  • Visual cortex responses to suprachoroidal electrical stimulation of the retina: effects of electrode return configuration.

    abstract::A clinically effective retinal prosthesis must evoke localized phosphenes in a retinotopic manner in response to stimulation of each of the retinal electrodes, evoke brightness cues over a wide dynamic range and function within safe stimulus limits. The effects of varying return configuration for retinal stimulation a...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/3/036009

    authors: Cicione R,Shivdasani MN,Fallon JB,Luu CD,Allen PJ,Rathbone GD,Shepherd RK,Williams CE

    更新日期:2012-06-01 00:00:00

  • A gait stability investigation into FES-assisted paraplegic walking based on the walker tipping index.

    abstract::The gait outcome measures used in clinical trials of paraplegic locomotor training determine the effectiveness of improved walking function assisted by the functional electrical stimulation (FES) system. Focused on kinematic, kinetic or physiological changes of paraplegic patients, traditional methods cannot quantify ...

    journal_title:Journal of neural engineering

    pub_type: 临床试验,杂志文章

    doi:10.1088/1741-2560/6/6/066007

    authors: Ming D,Bai Y,Liu X,Qi H,Cheng L,Wan B,Hu Y,Wong Y,Luk KD,Leong JC

    更新日期:2009-12-01 00:00:00

  • Performance measurement for brain-computer or brain-machine interfaces: a tutorial.

    abstract:OBJECTIVE:Brain-computer interfaces (BCIs) have the potential to be valuable clinical tools. However, the varied nature of BCIs, combined with the large number of laboratories participating in BCI research, makes uniform performance reporting difficult. To address this situation, we present a tutorial on performance me...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/11/3/035001

    authors: Thompson DE,Quitadamo LR,Mainardi L,Laghari KU,Gao S,Kindermans PJ,Simeral JD,Fazel-Rezai R,Matteucci M,Falk TH,Bianchi L,Chestek CA,Huggins JE

    更新日期:2014-06-01 00:00:00

  • Human-inspired sound environment recognition system for assistive vehicles.

    abstract:OBJECTIVE:The human auditory system acquires environmental information under sound stimuli faster than visual or touch systems, which in turn, allows for faster human responses to such stimuli. It also complements senses such as sight, where direct line-of-view is necessary to identify objects, in the environment recog...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/1/016012

    authors: Vidal EG,Zarricueta EF,Cheein FA

    更新日期:2015-02-01 00:00:00

  • Analysis of spontaneous MEG activity in mild cognitive impairment and Alzheimer's disease using spectral entropies and statistical complexity measures.

    abstract::Alzheimer's disease (AD) is the most common cause of dementia. Over the last few years, a considerable effort has been devoted to exploring new biomarkers. Nevertheless, a better understanding of brain dynamics is still required to optimize therapeutic strategies. In this regard, the characterization of mild cognitive...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/3/036007

    authors: Bruña R,Poza J,Gómez C,García M,Fernández A,Hornero R

    更新日期:2012-06-01 00:00:00

  • In vitro and in vivo stability of black-platinum coatings on flexible, polymer microECoG arrays.

    abstract:OBJECTIVE:Intracranial EEG (iEEG) or micro-electrocorticography (µECoG) microelectrodes offer high spatial resolution in recordings of neuronal activity from the exposed brain surface. Reliability of dielectric substrates and conductive materials of these devices are under intensive research in terms of functional stab...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aacf71

    authors: Zátonyi A,Fedor F,Borhegyi Z,Fekete Z

    更新日期:2018-10-01 00:00:00

  • Correspondence between visual and electrical input filters of ON and OFF mouse retinal ganglion cells.

    abstract:OBJECTIVE:Over the past two decades retinal prostheses have made major strides in restoring functional vision to patients blinded by diseases such as retinitis pigmentosa. Presently, implants use single pulses to activate the retina. Though this stimulation paradigm has proved beneficial to patients, an unresolved prob...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa722c

    authors: Sekhar S,Jalligampala A,Zrenner E,Rathbun DL

    更新日期:2017-08-01 00:00:00

  • Understanding ultrasound neuromodulation using a computationally efficient and interpretable model of intramembrane cavitation.

    abstract:OBJECTIVE:Low-intensity focused ultrasound stimulation (LIFUS) emerges as an attracting technology for noninvasive modulation of neural circuits, yet the underlying action mechanisms remain unclear. The neuronal intramembrane cavitation excitation (NICE) model suggests that LIFUS excites neurons through a complex inter...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab1685

    authors: Lemaire T,Neufeld E,Kuster N,Micera S

    更新日期:2019-08-01 00:00:00

  • Improving an open-source commercial system to reliably perform activity-dependent stimulation.

    abstract:OBJECTIVE:Activity-dependent stimulation (ADS) is designed to strengthen the connections between neuronal circuits and therefore may be a promising tool for promoting neurophysiological reorganization following a brain injury. To successfully perform this technique, two criteria must be met: (1) spikes in the extracell...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab3319

    authors: Murphy M,Buccelli S,Bornat Y,Bundy D,Nudo R,Guggenmos D,Chiappalone M

    更新日期:2019-10-29 00:00:00

  • Natural language processing with dynamic classification improves P300 speller accuracy and bit rate.

    abstract::The P300 speller is an example of a brain-computer interface that can restore functionality to victims of neuromuscular disorders. Although the most common application of this system has been communicating language, the properties and constraints of the linguistic domain have not to date been exploited when decoding b...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/1/016004

    authors: Speier W,Arnold C,Lu J,Taira RK,Pouratian N

    更新日期:2012-02-01 00:00:00

  • Advantages of soft subdural implants for the delivery of electrochemical neuromodulation therapies to the spinal cord.

    abstract:OBJECTIVE:We recently developed soft neural interfaces enabling the delivery of electrical and chemical stimulation to the spinal cord. These stimulations restored locomotion in animal models of paralysis. Soft interfaces can be placed either below or above the dura mater. Theoretically, the subdural location combines ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaa87a

    authors: Capogrosso M,Gandar J,Greiner N,Moraud EM,Wenger N,Shkorbatova P,Musienko P,Minev I,Lacour S,Courtine G

    更新日期:2018-04-01 00:00:00

  • Hardware architecture for real-time EEG-based functional brain connectivity parameter extraction.

    abstract::In this work, we proposed a novel architecture for real-time quantitative characterization of functional brain connectivity networks derived from Electroencephalogram (EEG). It consists of two main parts - calculation of Phase Lag Index (PLI) to form the functional connectivity networks and the extraction of a set of ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abd462

    authors: Gutierrez Nuno RA,Chung CHR,Maharatna K

    更新日期:2020-12-16 00:00:00

  • Creation of virtual channels in the retina using synchronous and asynchronous stimulation - a modelling study.

    abstract:OBJECTIVE:Implantable retinal prostheses aim to provide artificial vision to those suffering from retinal degenerative diseases by electrically stimulating the remaining retinal neurons using a multi-electrode array. The spatial resolution of these devices can be improved by creation of so-called virtual channels (VCs)...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abc3a9

    authors: Song X,Guo T,Shivdasani MN,Dokos S,Lovell NH,Li X,Qiu S,Li T,Zheng S,Li L

    更新日期:2020-10-21 00:00:00

  • Controlling selective stimulations below a spinal cord hemisection using brain recordings with a neural interface system approach.

    abstract::In this work we address the use of realtime cortical recordings for the generation of coherent, reliable and robust motor activity in spinal-lesioned animals through selective intraspinal microstimulation (ISMS). The spinal cord of adult rats was hemisectioned and groups of multielectrodes were implanted in both the c...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/4/046008

    authors: Panetsos F,Sanchez-Jimenez A,Torets C,Largo C,Micera S

    更新日期:2011-08-01 00:00:00

  • Early seizure detection for closed loop direct neurostimulation devices in epilepsy.

    abstract::Current treatment concepts for epilepsy are based on continuous drug delivery or electrical stimulation to prevent the occurrence of seizures, exposing the brain and body to a mostly unneeded risk of adverse effects. To address the infrequent occurrence and short duration of epileptic seizures, intelligent implantable...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2552/ab094a

    authors: Dümpelmann M

    更新日期:2019-08-01 00:00:00

  • Classification and regression of spatio-temporal signals using NeuCube and its realization on SpiNNaker neuromorphic hardware.

    abstract:OBJECTIVE:The objective of this work is to use the capability of spiking neural networks to capture the spatio-temporal information encoded in time-series signals and decode them without the use of hand-crafted features and vector-based learning and the realization of the spiking model on low-power neuromorphic hardwar...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aafabc

    authors: Behrenbeck J,Tayeb Z,Bhiri C,Richter C,Rhodes O,Kasabov N,Espinosa-Ramos JI,Furber S,Cheng G,Conradt J

    更新日期:2019-04-01 00:00:00

  • Coarse behavioral context decoding.

    abstract:OBJECTIVE:Current brain-computer interface (BCI) studies demonstrate the potential to decode neural signals obtained from structured and trial-based tasks to drive actuators with high performance within the context of these tasks. Ideally, to maximize utility, such systems will be applied to a wide range of behavioral ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaee9c

    authors: Alasfour A,Gabriel P,Jiang X,Shamie I,Melloni L,Thesen T,Dugan P,Friedman D,Doyle W,Devinsky O,Gonda D,Sattar S,Wang S,Halgren E,Gilja V

    更新日期:2019-02-01 00:00:00

  • A stationary wavelet transform and a time-frequency based spike detection algorithm for extracellular recorded data.

    abstract:OBJECTIVE:Spike detection from extracellular recordings is a crucial preprocessing step when analyzing neuronal activity. The decision whether a specific part of the signal is a spike or not is important for any kind of other subsequent preprocessing steps, like spike sorting or burst detection in order to reduce the c...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa654b

    authors: Lieb F,Stark HG,Thielemann C

    更新日期:2017-06-01 00:00:00

  • Selective recovery of fascicular activity in peripheral nerves.

    abstract::The peripheral nerves of an amputee's residual limb still carry the information required to provide the robust, natural control signals needed to command a dexterous prosthetic limb. However, these signals are mixed in the volume conductor of the body and extracting them is an unmet challenge. A beamforming algorithm ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/5/056005

    authors: Wodlinger B,Durand DM

    更新日期:2011-10-01 00:00:00

  • Decoder calibration with ultra small current sample set for intracortical brain-machine interface.

    abstract:OBJECTIVE:Intracortical brain-machine interfaces (iBMIs) aim to restore efficient communication and movement ability for paralyzed patients. However, frequent recalibration is required for consistency and reliability, and every recalibration will require relatively large most current sample set. The aim in this study i...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaa8a4

    authors: Zhang P,Ma X,Chen L,Zhou J,Wang C,Li W,He J

    更新日期:2018-04-01 00:00:00

  • A framework for designing data-driven optimization systems for neural modulation.

    abstract:OBJECTIVE:Neural modulation is a fundamental tool for understanding and treating neurological and psychiatric diseases. However, due to the high-dimensional space, subject-specific responses, and variability within each subject, it is a major challenge to select the stimulation parameters that have the desired effect. ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abd048

    authors: Connolly MJ,Park SE,Laxpati NG,Zaidi SA,Ghetiya M,Fernandez A,Gutekunst CA,Gross RE

    更新日期:2020-12-03 00:00:00

  • Ultraminiaturized photovoltaic and radio frequency powered optoelectronic systems for wireless optogenetics.

    abstract:OBJECTIVE:Wireless control and power harvesting systems that operate injectable, cellular-scale optoelectronic components provide important demonstrated capabilities in neuromodulatory techniques such as optogenetics. Here, we report a radio frequency (RF) control/harvesting device that offers dramatically reduced size...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/5/056002

    authors: Park SI,Shin G,Banks A,McCall JG,Siuda ER,Schmidt MJ,Chung HU,Noh KN,Mun JG,Rhodes J,Bruchas MR,Rogers JA

    更新日期:2015-10-01 00:00:00

  • Transparent, low-autofluorescence microECoG device for simultaneous Ca2+ imaging and cortical electrophysiology in vivo.

    abstract:OBJECTIVE:Multimodal neuroimaging approaches are beneficial to discover brain functionalities at high spatial and temporal resolution. In our work, a novel material composition of a microECoG device relying on Parylene HT and indium-tin-oxide (ITO) is presented, which facilitates two-photon imaging of Ca2+ signals and ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab603f

    authors: Zátonyi A,Madarász M,Szabó Á,Lőrincz T,Hodován R,Rózsa B,Fekete Z

    更新日期:2020-02-18 00:00:00

  • Rhythmic modulation of thalamic oscillations depends on intrinsic cellular dynamics.

    abstract:OBJECTIVE:Rhythmic brain stimulation has emerged as a powerful tool to modulate cognition and to target pathological oscillations related to neurological and psychiatric disorders. However, we lack a systematic understanding of how periodic stimulation interacts with endogenous neural activity as a function of the brai...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaeb03

    authors: Li G,Henriquez CS,Fröhlich F

    更新日期:2019-02-01 00:00:00

  • A novel flexible cuff-like microelectrode for dual purpose, acute and chronic electrical interfacing with the mouse cervical vagus nerve.

    abstract:OBJECTIVE:Neural reflexes regulate immune responses and homeostasis. Advances in bioelectronic medicine indicate that electrical stimulation of the vagus nerve can be used to treat inflammatory disease, yet the understanding of neural signals that regulate inflammation is incomplete. Current interfaces with the vagus n...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa7a42

    authors: Caravaca AS,Tsaava T,Goldman L,Silverman H,Riggott G,Chavan SS,Bouton C,Tracey KJ,Desimone R,Boyden ES,Sohal HS,Olofsson PS

    更新日期:2017-12-01 00:00:00

  • An improved P300 pattern in BCI to catch user's attention.

    abstract:OBJECTIVE:Brain-computer interfaces (BCIs) can help patients who have lost control over most muscles but are still conscious and able to communicate or interact with the environment. One of the most popular types of BCI is the P300-based BCI. With this BCI, users are asked to count the number of appearances of target s...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa6213

    authors: Jin J,Zhang H,Daly I,Wang X,Cichocki A

    更新日期:2017-06-01 00:00:00

  • Spatial and temporal variability in response to hybrid electro-optical stimulation.

    abstract::Hybrid electro-optical neural stimulation is a novel paradigm combining the advantages of optical and electrical stimulation techniques while reducing their respective limitations. However, in order to fulfill its promise, this technique requires reduced variability and improved reproducibility. Here we used a compara...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/3/036003

    authors: Duke AR,Lu H,Jenkins MW,Chiel HJ,Jansen ED

    更新日期:2012-06-01 00:00:00

  • In vivo feasibility of epiretinal stimulation using ultrananocrystalline diamond electrodes.

    abstract:OBJECTIVE:Due to their increased proximity to retinal ganglion cells (RGCs), epiretinal visual prostheses present the opportunity for eliciting phosphenes with low thresholds through direct RGC activation. This study characterised the in vivo performance of a novel prototype monolithic epiretinal prosthesis, containing...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aba560

    authors: Shivdasani MN,Evans M,Burns O,Yeoh J,Allen PJ,Nayagam DAX,Villalobos J,Abbott CJ,Luu CD,Opie NL,Sabu A,Saunders AL,McPhedran M,Cardamone L,McGowan C,Maxim V,Williams RA,Fox KE,Cicione R,Garrett DJ,Ahnood A,Ganes

    更新日期:2020-08-05 00:00:00

  • VITA-an everyday virtual reality setup for prosthetics and upper-limb rehabilitation.

    abstract:OBJECTIVE:Currently, there are some 95 000 people in Europe suffering from upper-limb impairment. Rehabilitation should be undertaken right after the impairment occurs and should be regularly performed thereafter. Moreover, the rehabilitation process should be tailored specifically to both patient and impairment. APPR...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaf35f

    authors: Nissler C,Nowak M,Connan M,Büttner S,Vogel J,Kossyk I,Márton ZC,Castellini C

    更新日期:2019-04-01 00:00:00

  • A robust two-stage sleep spindle detection approach using single-channel EEG.

    abstract:OBJECTIVE:Sleep spindles in the electroencephalogram (EEG) are significant in sleep analysis related to cognitive functions and neurological diseases, and thus are of great clinical interests. An automatic sleep spindle detection algorithm could help decrease the workload of visual inspection by sleep clinicians. APPR...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abd463

    authors: Jiang D,Ma Y,Wang Y

    更新日期:2020-12-16 00:00:00