Ultraminiaturized photovoltaic and radio frequency powered optoelectronic systems for wireless optogenetics.

Abstract:

OBJECTIVE:Wireless control and power harvesting systems that operate injectable, cellular-scale optoelectronic components provide important demonstrated capabilities in neuromodulatory techniques such as optogenetics. Here, we report a radio frequency (RF) control/harvesting device that offers dramatically reduced size, decreased weight and improved efficiency compared to previously reported technologies. Combined use of this platform with ultrathin, multijunction, high efficiency solar cells allows for hundred-fold reduction of transmitted RF power, which greatly enhances the wireless coverage. APPROACH:Fabrication involves separate construction of the harvester and the injectable µ-ILEDs. To test whether the presence of the implantable device alters behavior, we implanted one group of wild type mice and compared sociability behavior to unaltered controls. Social interaction experiments followed protocols defined by Silverman et al. with minor modifications. MAIN RESULTS:The results presented here demonstrate that miniaturized RF harvesters, and RF control strategies with photovoltaic harvesters can, when combined with injectable µ-ILEDs, offer versatile capabilities in optogenetics. Experimental and modeling studies establish a range of effective operating conditions for these two approaches. Optogenetics studies with social groups of mice demonstrate the utility of these systems. SIGNIFICANCE:The addition of miniaturized, high performance photovoltaic cells significantly expands the operating range and reduces the required RF power. The platform can offer capabilities to modulate signaling path in the brain region of freely-behaving animals. These suggest its potential for widespread use in neuroscience.

journal_name

J Neural Eng

authors

Park SI,Shin G,Banks A,McCall JG,Siuda ER,Schmidt MJ,Chung HU,Noh KN,Mun JG,Rhodes J,Bruchas MR,Rogers JA

doi

10.1088/1741-2560/12/5/056002

subject

Has Abstract

pub_date

2015-10-01 00:00:00

pages

056002-56002

issue

5

eissn

1741-2560

issn

1741-2552

journal_volume

12

pub_type

杂志文章
  • Optimizing the design of bipolar nerve cuff electrodes for improved recording of peripheral nerve activity.

    abstract:OBJECTIVE:Differential measurement of efferent and afferent peripheral nerve activity offers a promising means of improving the clinical utility of implantable neuroprostheses. The tripolar nerve cuff electrode has historically served as the gold standard for achieving high signal-to-noise ratios (SNRs) of the recordin...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa6407

    authors: Sabetian P,Popovic MR,Yoo PB

    更新日期:2017-06-01 00:00:00

  • Human-inspired sound environment recognition system for assistive vehicles.

    abstract:OBJECTIVE:The human auditory system acquires environmental information under sound stimuli faster than visual or touch systems, which in turn, allows for faster human responses to such stimuli. It also complements senses such as sight, where direct line-of-view is necessary to identify objects, in the environment recog...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/1/016012

    authors: Vidal EG,Zarricueta EF,Cheein FA

    更新日期:2015-02-01 00:00:00

  • Millimeter-scale epileptiform spike propagation patterns and their relationship to seizures.

    abstract:OBJECTIVE:Current mapping of epileptic networks in patients prior to epilepsy surgery utilizes electrode arrays with sparse spatial sampling (∼1.0 cm inter-electrode spacing). Recent research demonstrates that sub-millimeter, cortical-column-scale domains have a role in seizure generation that may be clinically signifi...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/2/026015

    authors: Vanleer AC,Blanco JA,Wagenaar JB,Viventi J,Contreras D,Litt B

    更新日期:2016-04-01 00:00:00

  • The statistical distribution of noisy transmission in human sensors.

    abstract:OBJECTIVE:Brains, like other physical devices, are inherently noisy. This source of variability is large, to the extent that internal noise often impacts human sensory processing more than externally induced (stimulus-driven) perturbations. Despite the fundamental nature of this phenomenon, its statistical distribution...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/1741-2560/10/1/016014

    authors: Neri P

    更新日期:2013-02-01 00:00:00

  • Multiresolution analysis over simple graphs for brain computer interfaces.

    abstract:OBJECTIVE:Multiresolution analysis (MRA) offers a useful framework for signal analysis in the temporal and spectral domains, although commonly employed MRA methods may not be the best approach for brain computer interface (BCI) applications. This study aims to develop a new MRA system for extracting tempo-spatial-spect...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/4/046014

    authors: Asensio-Cubero J,Gan JQ,Palaniappan R

    更新日期:2013-08-01 00:00:00

  • Bispectrum-based feature extraction technique for devising a practical brain-computer interface.

    abstract::The extraction of distinctly separable features from electroencephalogram (EEG) is one of the main challenges in designing a brain-computer interface (BCI). Existing feature extraction techniques for a BCI are mostly developed based on traditional signal processing techniques assuming that the signal is Gaussian and h...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/2/025014

    authors: Shahid S,Prasad G

    更新日期:2011-04-01 00:00:00

  • On robust parameter estimation in brain-computer interfacing.

    abstract:OBJECTIVE:The reliable estimation of parameters such as mean or covariance matrix from noisy and high-dimensional observations is a prerequisite for successful application of signal processing and machine learning algorithms in brain-computer interfacing (BCI). This challenging task becomes significantly more difficult...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa8232

    authors: Samek W,Nakajima S,Kawanabe M,Müller KR

    更新日期:2017-12-01 00:00:00

  • Analysis of the quasi-static approximation for calculating potentials generated by neural stimulation.

    abstract::In models of electrical stimulation of the nervous system, the electric potential is typically calculated using the quasi-static approximation. The quasi-static approximation allows Maxwell's equations to be simplified by ignoring capacitive, inductive and wave propagation contributions to the potential. While this si...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/5/1/005

    authors: Bossetti CA,Birdno MJ,Grill WM

    更新日期:2008-03-01 00:00:00

  • Comment on 'fast attainment of computer cursor control with noninvasively acquired brain signals'.

    abstract::In a recent paper by Bradberry, Gentili and Contreras-Vidal published in Journal of Neural Engineering (2011, 8 036010), an interesting method for the control of a two-dimensional mouse cursor was proposed, which apparently attained excellent control and good speed with relatively simple techniques. We believe some of...

    journal_title:Journal of neural engineering

    pub_type: 评论,杂志文章

    doi:10.1088/1741-2560/8/5/058001

    authors: Poli R,Salvaris M

    更新日期:2011-10-01 00:00:00

  • An analysis of glutamate spillover on the N-methyl-D-aspartate receptors at the cerebellar glomerulus.

    abstract::Glutamate spillover is thought to play a significant role in increasing neural transmission at the mossy fiber/granule cell cerebellar glomerulus. Glutamate spillover has been shown to activate AMPA receptors at the glomerulus, and here we complete the characterization of spillover at the glomerulus by investigating t...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/4/3/013

    authors: Mitchell CS,Feng SS,Lee RH

    更新日期:2007-09-01 00:00:00

  • BCILAB: a platform for brain-computer interface development.

    abstract:OBJECTIVE:The past two decades have seen dramatic progress in our ability to model brain signals recorded by electroencephalography, functional near-infrared spectroscopy, etc., and to derive real-time estimates of user cognitive state, response, or intent for a variety of purposes: to restore communication by the seve...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/5/056014

    authors: Kothe CA,Makeig S

    更新日期:2013-10-01 00:00:00

  • Dual stream neural networks for brain signal classification.

    abstract::In this paper we propose a dual stream neural network (DSNN) for classifying arbitrary collections of functional neuroimaging signals for the purpose of brain computer interfaces (BCIs). In the DSNN the first stream is an end-to-end classifier taking raw time-dependent signals as input and generating feature identific...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abc903

    authors: Kuang D,Michoski C

    更新日期:2020-11-10 00:00:00

  • Applying dynamic data collection to improve dry electrode system performance for a P300-based brain-computer interface.

    abstract:OBJECTIVE:Dry electrodes have an advantage over gel-based 'wet' electrodes by providing quicker set-up time for electroencephalography recording; however, the potentially poorer contact can result in noisier recordings. We examine the impact that this may have on brain-computer interface communication and potential app...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/6/066018

    authors: Clements JM,Sellers EW,Ryan DB,Caves K,Collins LM,Throckmorton CS

    更新日期:2016-12-01 00:00:00

  • High-fidelity vibrokinetic stimulation induces sustained changes in intercortical coherence during a cinematic experience.

    abstract:OBJECTIVE:High-fidelity vibrokinetic (HFVK) technology is widely used to enhance the immersiveness of audiovisual (AV) entertainment experiences. However, despite evidence that HFVK technology does subjectively enhance AV immersion, the underlying mechanism has not been clarified. Neurophysiological studies could provi...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abaca2

    authors: Boasen J,Giroux F,Duchesneau MO,Sénécal S,Léger PM,Ménard JF

    更新日期:2020-09-26 00:00:00

  • Stimulation strategies for selective activation of retinal ganglion cell soma and threshold reduction.

    abstract:OBJECTIVE:Retinal prosthetic implants restore partial vision to patients blinded due to outer retinal degeneration, using a camera-guided multielectrode array (MEA) that electrically stimulates surviving retinal neurons. Commercial epi-retinal prostheses use millisecond-scale charge-balanced, symmetric, cathodic-first ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaf92b

    authors: Chang YC,Haji Ghaffari D,Chow RH,Weiland JD

    更新日期:2019-04-01 00:00:00

  • Multi-class EEG classification of voluntary hand movement directions.

    abstract:OBJECTIVE:Studies have shown that low frequency components of brain recordings provide information on voluntary hand movement directions. However, non-invasive techniques face more challenges compared to invasive techniques. APPROACH:This study presents a novel signal processing technique to extract features from non-...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/5/056018

    authors: Robinson N,Guan C,Vinod AP,Ang KK,Tee KP

    更新日期:2013-10-01 00:00:00

  • P300-based brain-computer interface for environmental control: an asynchronous approach.

    abstract::Brain-computer interface (BCI) systems allow people with severe motor disabilities to communicate and interact with the external world. The P300 potential is one of the most used control signals for EEG-based BCIs. Classic P300-based BCIs work in a synchronous mode; the synchronous control assumes that the user is con...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/2/025025

    authors: Aloise F,Schettini F,Aricò P,Leotta F,Salinari S,Mattia D,Babiloni F,Cincotti F

    更新日期:2011-04-01 00:00:00

  • Hyperparameter-tuned prediction of somatic symptom disorder using functional near-infrared spectroscopy-based dynamic functional connectivity.

    abstract:OBJECTIVE:Somatic symptom disorder (SSD) is a reflection of medically unexplained physical symptoms that lead to distress and impairment in social and occupational functioning. SSD is phenomenologically diagnosed and its neurobiology remains unsolved. APPROACH:In this study, we performed hyper-parameter optimized clas...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab50b2

    authors: Eken A,Çolak B,Bal NB,Kuşman A,Kızılpınar SÇ,Akaslan DS,Baskak B

    更新日期:2019-12-16 00:00:00

  • Suppression of scarring in peripheral nerve implants by drug elution.

    abstract:OBJECTIVE:Medical implants made of non-biological materials provoke a chronic inflammatory response, resulting in the deposition of a collagenous scar tissue (ST) layer on their surface, that gradually thickens over time. This is a critical problem for neural interfaces. Scar build-up on electrodes results in a progres...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/2/026006

    authors: FitzGerald JJ

    更新日期:2016-04-01 00:00:00

  • A practical guide to methodological considerations in the controllability of structural brain networks.

    abstract:OBJECTIVE:Predicting how the brain can be driven to specific states by means of internal or external control requires a fundamental understanding of the relationship between neural connectivity and activity. Network control theory is a powerful tool from the physical and engineering sciences that can provide insights r...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab6e8b

    authors: Karrer TM,Kim JZ,Stiso J,Kahn AE,Pasqualetti F,Habel U,Bassett DS

    更新日期:2020-04-09 00:00:00

  • Functional consequences of model complexity in rhythmic systems: II. Systems performance of model and hybrid oscillators.

    abstract::Neural models are increasingly being used as design components of physical systems. In order to best use models in these novel contexts, we must develop design rules that describe how decisions in model construction relate to the functional performance of the resulting system. In the accompanying paper, we described a...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/4/3/003

    authors: Sorensen ME,DeWeerth SP

    更新日期:2007-09-01 00:00:00

  • An improved P300 pattern in BCI to catch user's attention.

    abstract:OBJECTIVE:Brain-computer interfaces (BCIs) can help patients who have lost control over most muscles but are still conscious and able to communicate or interact with the environment. One of the most popular types of BCI is the P300-based BCI. With this BCI, users are asked to count the number of appearances of target s...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa6213

    authors: Jin J,Zhang H,Daly I,Wang X,Cichocki A

    更新日期:2017-06-01 00:00:00

  • Rehabilitation regimes based upon psychophysical studies of prosthetic vision.

    abstract::Human trials of prototype visual prostheses have successfully elicited visual percepts (phosphenes) in the visual field of implant recipients blinded through retinitis pigmentosa and age-related macular degeneration. Researchers are progressing rapidly towards a device that utilizes individual phosphenes as the elemen...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2560/6/3/035009

    authors: Chen SC,Suaning GJ,Morley JW,Lovell NH

    更新日期:2009-06-01 00:00:00

  • Focused electrical stimulation using a single current source.

    abstract:OBJECTIVE:Cochlear implants, while providing significant benefits to recipients, remain limited due to broad neural activation. Focussed multipolar stimulation (FMP) is an advanced stimulation strategy that uses multiple current sources to produce highly focussed patterns of neural excitation in order to overcome these...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aad0a5

    authors: Senn P,Shepherd RK,Fallon JB

    更新日期:2018-10-01 00:00:00

  • Acoustoelectric imaging of deep dipoles in a human head phantom for guiding treatment of epilepsy.

    abstract:OBJECTIVE:This study employs a human head model with real skull to demonstrate the feasibility of transcranial acoustoelectric brain imaging (tABI) as a new modality for electrical mapping of deep dipole sources during treatment of epilepsy with much better resolution and accuracy than conventional mapping methods. AP...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abb63a

    authors: Barragan A,Preston C,Alvarez A,Bera T,Qin Y,Weinand M,Kasoff W,Witte RS

    更新日期:2020-10-30 00:00:00

  • Adaptive deep brain stimulation for Parkinson's disease using motor cortex sensing.

    abstract:OBJECTIVE:Contemporary deep brain stimulation (DBS) for Parkinson's disease is delivered continuously, and adjustments based on patient's changing symptoms must be made manually by a trained clinician. Patients may be subjected to energy intensive settings at times when they are not needed, possibly resulting in stimul...

    journal_title:Journal of neural engineering

    pub_type: 临床试验,杂志文章

    doi:10.1088/1741-2552/aabc9b

    authors: Swann NC,de Hemptinne C,Thompson MC,Miocinovic S,Miller AM,Gilron R,Ostrem JL,Chizeck HJ,Starr PA

    更新日期:2018-08-01 00:00:00

  • Multiple factors may influence the performance of a visual prosthesis based on intracortical microstimulation: nonhuman primate behavioural experimentation.

    abstract::We hypothesize that a visual prosthesis capable of evoking high-resolution visual perceptions can be produced using high-electrode-count arrays of penetrating microelectrodes implanted into the primary visual cortex of a blind human subject. To explore this hypothesis, and as a prelude to human psychophysical experime...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/3/035001

    authors: Torab K,Davis TS,Warren DJ,House PA,Normann RA,Greger B

    更新日期:2011-06-01 00:00:00

  • Toward the development of a color visual prosthesis.

    abstract::All of the human prosthetic visual systems implanted so far have been achromatic. Schmidt et al. (1996) reported that at low stimulation intensities their subject reported that phosphenes usually had a specific hue, but when the stimulus intensity was increased, they desaturated to white. We speculate here that previo...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abd520

    authors: Towle V,Pham T,McCaffrey M,Allen D,Troyk PR

    更新日期:2020-12-18 00:00:00

  • Effects of stimulation frequency and stimulation waveform on steady-state visual evoked potentials using a computer monitor.

    abstract:OBJECTIVE:A visual stimulator plays a vital part in brain-computer interfaces (BCIs) based on steady-state visual evoked potential (SSVEP). The properties of visual stimulation, such as frequency, color, and waveform, will influence SSVEP-based BCI performance to some extent. Recently, the computer monitor serves as a ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab2b7d

    authors: Chen X,Wang Y,Zhang S,Xu S,Gao X

    更新日期:2019-10-10 00:00:00

  • Inclusion of temporal priors for automated neonatal EEG classification.

    abstract::The aim of this paper is to use recent advances in the clinical understanding of the temporal evolution of seizure burden in neonates with hypoxic ischemic encephalopathy to improve the performance of automated detection algorithms. Probabilistic weights are designed from temporal locations of neonatal seizure events ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/4/046002

    authors: Temko A,Stevenson N,Marnane W,Boylan G,Lightbody G