Fast acceleration of ASL-based time-resolved magnetic resonance angiography by acquisition of control and labeled images in the same shot (fast ACTRESS): An optimization study.

Abstract:

PURPOSE:To establish an optimized sequence design for fast acceleration of arterial spin labeling (ASL)-based time-resolved magnetic resonance angiography (MRA) by acquisition of control and labeled images in the same shot (fast ACTRESS) and a scan time of <1min, for the evaluation of intracranial vessels. MATERIALS AND METHODS:Ten healthy volunteers with no unilateral symptomatic arterial stenosis, who underwent 3-tesla MRI, were investigated. Imaging parameters for the fast ACTRESS sequence were set with an acquisition time of 45s. During post-processing, the first phase in the multi-phase readout, which was defined as the control image, was subtracted from each of the other phases. Thus, four-dimensional (4D)-MRA images of each phase were obtained. The maximum intensity projection was used for the reconstruction of 4D-MRA images and time-to-signal intensity curves (TIC) obtained for each vessel. The area under the curve (AUC), peak time, and maximum signal intensity were obtained from TIC. The different labeling types were broadly divided into six groups: L1, L2, L3, L4, L5, and L6 according to the actual number of labeling pulse. RESULTS:A total of 5040 regions of interest were evaluated. The peak SI of L3, except for those in the A2 segment of the anterior cerebral artery, was significantly higher than that of L5. However, there were no significant differences between L4 and L5. Although the AUCs of L3 and L4 for anterior circulation were relatively higher than that of the other subgroups, the AUC of L3 was significantly higher than that of L4. CONCLUSION:The fast ACTRESS was optimized and indicated that the labeling type of L3 was the most appropriate for the well visualization of intracranial arteries. The fast ACTRESS sequence was useful to acquire well-delineated images of intracranial vessels in ˂1min.

journal_name

Magn Reson Imaging

authors

Sugimori H,Fujima N,Suzuki Y,Hamaguchi H,Ishizaka K,Kudo K

doi

10.1016/j.mri.2017.07.026

subject

Has Abstract

pub_date

2017-11-01 00:00:00

pages

136-143

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(17)30151-0

journal_volume

43

pub_type

杂志文章
  • Tsallis-Entropy Segmentation through MRF and Alzheimer anatomic reference for Brain Magnetic Resonance Parcellation.

    abstract::Quantifying the intracranial tissue volume changes in magnetic resonance imaging (MRI) assists specialists to analyze the effects of natural or pathological changes. Since these changes can be subtle, the accuracy of the automatic compartmentalization method is always criticized by specialists. We propose and then eva...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.11.002

    authors: Azimbagirad M,Simozo FH,Senra Filho ACS,Murta Junior LO

    更新日期:2020-01-01 00:00:00

  • DTI of trabecular bone marrow.

    abstract::The development of NMR diffusion imaging and diffusion tensor imaging (DTI) has offered the possibility of studying the porous structures beyond anatomical imaging. In fact, random molecular motions, within tissue components, probe tissue microstructures. Up to now, the DTI method was mainly used to investigate cerebr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.11.018

    authors: Rossi C,Capuani S,Fasano F,Alesiani M,Maraviglia B

    更新日期:2005-02-01 00:00:00

  • 1H-MRS of the macaque monkey primary visual cortex at 7 T: strategies and pitfalls of shimming at the brain surface.

    abstract::Magnetic resonance spectroscopy (MRS) is ideally suited for physiology-neurochemistry experiments with the living brain and particularly for studies on the primary visual cortex (striate cortex or area V1). Yet, the highly convoluted form of the human V1 has thus far prevented the performance of MRS investigations tha...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.03.008

    authors: Juchem C,Logothetis NK,Pfeuffer J

    更新日期:2007-07-01 00:00:00

  • Nuclear magnetic resonance imaging techniques as developed modestly within a university medical center environment: what can the small system contribute at this point?

    abstract::This paper describes a geometrically small NMR imaging system which has been developed and assembled within a university medical center environment. Consideration is given to the technical specifications and basic economics for the magnet system, NMR spectrometer, and computer configuration. Initial research objective...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(82)90268-5

    authors: Thomas SR,Ackerman JL,Goebel JR,Davis M,Kereiakes JG,Lin YY

    更新日期:1982-01-01 00:00:00

  • Identification and characterization of biological tissues by NMR. Concerted research project of the European Economic Community. Introduction, objectives, and activities.

    abstract::NMR offers, in the complex proton relaxation properties of biological tissues, a unique and potentially powerful tool of tissue characterization. The difficulties encountered so far in comparing the results of in vitro and in vivo NMR studies carried out in different laboratories inhibit NMR methodologies from fully e...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90447-x

    authors: Podo F,Orr JS,Schmidt KH,Bovée WM

    更新日期:1988-03-01 00:00:00

  • Synthesis of magnetic gradients for NMR tomography.

    abstract::A numerical method is applied to calculate an optimal distribution of currents in air which generate the magnetic field gradients required to spatially encode the radiofrequency signal in a NMR tomographic experiment. We compare the performances of the gradient circuits for the whole body air-core electromagnet descri...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90242-t

    authors: Mustarelli P,Rudnicki M,Savini A,Savoldi F,Villa M

    更新日期:1990-01-01 00:00:00

  • Assessment of the anomalous pulmonary circulation by dynamic contrast-enhanced MR angiography in under four seconds.

    abstract::The purpose of this study was to demonstrate the initial results of the dynamic contrast-enhanced MRA in under four seconds in the assessment of anomalous pulmonary circulation. We performed dynamic contrast enhanced MRA on ten patients with a temporal resolution of 2-3 sec for each phase. Five patients had pulmonary ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00634-3

    authors: Balci NC,Yalçin Y,Tunaci A,Balci Y

    更新日期:2003-01-01 00:00:00

  • Perfusion imaging by un-inverted flow-sensitive alternating inversion recovery (UNFAIR).

    abstract::A new pulse sequence for estimating cerebral blood flow called UNFAIR, which uses a combination of sequential hyperbolic secant preparatory pulses, is introduced. This sequence is based on the same generalized conditions as previously introduced inversion recovery techniques except that the spins in the image slice of...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00353-0

    authors: Helpern JA,Branch CA,Yongbi MN,Huang NC

    更新日期:1997-01-01 00:00:00

  • Lateral ventricular cerebrospinal fluid diffusivity as a potential neuroimaging marker of brain temperature in multiple sclerosis: a hypothesis and implications.

    abstract::In this retrospective study we tested the hypothesis that the net effect of impaired electrical conduction and therefore increased heat dissipation in multiple sclerosis (MS) results in elevated lateral ventricular (LV) cerebrospinal fluid (CSF) diffusivity as a measure of brain temperature estimated in vivo using dif...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.11.002

    authors: Hasan KM,Lincoln JA,Nelson FM,Wolinsky JS,Narayana PA

    更新日期:2015-04-01 00:00:00

  • High-field magnetic resonance imaging using solenoid radiofrequency coils.

    abstract::High-resolution magnetic resonance imaging using dedicated high-field radiofrequency micro-coils at 16.4 T (700 MHz) was investigated. Specific solenoid coils primarily using silver and copper as conductors with enamel and polyurethane coatings were built to establish which coil configuration produces the best image. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.04.027

    authors: Vegh V,Gläser P,Maillet D,Cowin GJ,Reutens DC

    更新日期:2012-10-01 00:00:00

  • Correlation of MRI findings to histology of acetaminophen toxicity in the mouse.

    abstract::Acetaminophen (APAP) toxicity is responsible for approximately half of all cases of acute liver failure in the United States. The mouse model of APAP toxicity is widely used to examine mechanisms of APAP toxicity. Noninvasive approaches would allow for serial measurements in a single animal to study the effects of exp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.09.023

    authors: Brown AT,Ou X,James LP,Jambhekar K,Pandey T,McCullough S,Chaudhuri S,Borrelli MJ

    更新日期:2012-02-01 00:00:00

  • Visualisation of changes in regional cerebral blood flow (rCBF) produced by ketamine using long TE gradient-echo sequences: preliminary results.

    abstract::Autoradiographic studies have shown that low dose ketamine produces increases in regional glucose utilisation and blood flow in the hippocampus, cerebral cortex, and olfactory lobe in the rat brain, probably due to antagonism at the NMDA receptor. Functional MRI using deoxyhaemoglobin contrast can be used to study cha...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00010-e

    authors: Burdett NG,Menon DK,Carpenter TA,Jones JG,Hall LD

    更新日期:1995-01-01 00:00:00

  • Evaluation of water content by spatially resolved transverse relaxation times of human articular cartilage.

    abstract::Non-invasive assessment of cartilage properties, specifically water content, could prove helpful in the diagnosis of early degenerative joint diseases. Transverse relaxation times T(2) of human articular cartilage (34 cartilage slices of three donors) were measured on a pixel-by-pixel basis in a clinical whole body MR...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00144-7

    authors: Lüsse S,Claassen H,Gehrke T,Hassenpflug J,Schünke M,Heller M,Glüer CC

    更新日期:2000-05-01 00:00:00

  • Dependence of temporal diffusion spectra on microstructural properties of biological tissues.

    abstract::The apparent diffusion coefficient (ADC) measured using magnetic resonance imaging methods provides information on microstructural properties of biological tissues, and thus has found applications as a useful biomarker for assessing changes such as those that occur in ischemic stroke and cancer. Conventional pulsed gr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.10.002

    authors: Xu J,Does MD,Gore JC

    更新日期:2011-04-01 00:00:00

  • Lesion load measurements in multiple sclerosis: the effect of incorporating magnetization transfer contrast in fast-FLAIR sequence.

    abstract::We compared the ability and reproducibility of a fast fluid-attenuated inversion recovery (fast-FLAIR) sequence with and without a magnetization transfer (MT) pulse for detecting and measuring multiple sclerosis (MS)-related abnormalities on magnetic resonance imaging (MRI) scans from 20 patients. The Contrast-to-Nois...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00182-9

    authors: Filippi M,Rocca MA,Mastronardo G,Comi G

    更新日期:1999-04-01 00:00:00

  • Identification of an optimal threshold for detecting human brown adipose tissue using receiver operating characteristic analysis of IDEAL MRI fat fraction maps.

    abstract:PURPOSE:Lower fat fraction (FF) in brown adipose tissue (BAT) than white adipose tissue (WAT) has been exploited using Dixon-based Magnetic Resonance Imaging (MRI) to differentiate these tissues in rodents, human infants and adults. We aimed to determine whether an optimal FF threshold could be determined to differenti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.04.013

    authors: Jones TA,Wayte SC,Reddy NL,Adesanya O,Dimitriadis GK,Barber TM,Hutchinson CE

    更新日期:2018-09-01 00:00:00

  • Single-shot-double-echo EPI.

    abstract::Echo planar imaging (EPI) was extended for the acquisition of both, the spin-echo (SE) and the stimulated echo in a stimulated echo sequence after one excitation from thermal equilibrium. The two independent EPI images reflect different states of the transverse magnetization excited and measured almost simultaneously....

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91234-n

    authors: Börnert P,Jensen D

    更新日期:1994-01-01 00:00:00

  • Magnetic resonance imaging at frequencies below 1 kHz.

    abstract::Within the magnetic resonance imaging (MRI) community the trend is going to higher and higher magnetic fields, ranging from 1.5 T to 7 T, corresponding to Larmor frequencies of 63.8-298 MHz. Since for high-field MRI the magnetization increases with the applied magnetic field, the signal-to-noise-ratio increases as wel...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.014

    authors: Hilschenz I,Körber R,Scheer HJ,Fedele T,Albrecht HH,Mario Cassará A,Hartwig S,Trahms L,Haase J,Burghoff M

    更新日期:2013-02-01 00:00:00

  • Comparison of different methods for combining phase-contrast images obtained with multiple coils.

    abstract::The ability to determine coil sensitivities implies that a method optimized in terms of maximized signal-to-noise ratio (SNR) can be applied to the combination of multiple coil images. An optimization of SNR subsequently results in a minimized variance in quantitative velocity measurements using phase-contrast imaging...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.06.002

    authors: Thunberg P,Karlsson M,Wigström L

    更新日期:2005-09-01 00:00:00

  • Pharmacokinetic analysis of glioma compartments with dynamic Gd-DTPA-enhanced magnetic resonance imaging.

    abstract::Dynamic contrast-enhanced magnetic resonance imaging (MRI) is widely used for measuring perfusion and blood volume, especially cerebral blood volume (CBV). In case of blood-brain barrier (BBB) disruption, the conventional techniques only partially determine the pharmacokinetic parameters of contrast medium (CM) exchan...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00223-x

    authors: Lüdemann L,Hamm B,Zimmer C

    更新日期:2000-12-01 00:00:00

  • Rapid and recoverable in vivo magnetic resonance imaging of the adult zebrafish at 7T.

    abstract::Increasing scientific interest in the zebrafish as a model organism across a range of biomedical and biological research areas raises the need for the development of in vivo imaging tools appropriate to this subject. Development of the embryonic and early stage forms of the subject can currently be assessed using opti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.10.013

    authors: Merrifield GD,Mullin J,Gallagher L,Tucker C,Jansen MA,Denvir M,Holmes WM

    更新日期:2017-04-01 00:00:00

  • Quantitative magnetic resonance imaging of 'Fuyu' persimmon fruit during development and ripening.

    abstract::Qualitative and quantitative proton magnetic resonance imaging techniques were applied to persimmon (Diospyros kaki cv 'Fuyu') fruit during development and post-harvest ripening. Spin-lattice (T(1)) relaxation times in mesocarp parenchyma and vascular tissue exhibited a sigmoidal pattern of increase leading to commerc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00082-1

    authors: Clark CJ,MacFall JS

    更新日期:2003-07-01 00:00:00

  • Evaluation of a contraceptive device with MR imaging.

    abstract::The purpose of this investigation is to evaluate the positioning and to confirm the volume concept of the Lea's Shield diaphragm utilizing MR imaging. We evaluated the device in two women, one nulliparous and one multiparous. We were able to comprehensively evaluate the device in both patients and answer all questions...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00385-x

    authors: Maldjian C,Pelosi MA 2nd,Pelosi MA 3rd,Adam R

    更新日期:2001-06-01 00:00:00

  • Spatial normalization, bulk motion correction and coregistration for functional magnetic resonance imaging of the human cervical spinal cord and brainstem.

    abstract::Functional magnetic resonance imaging (fMRI) of the cortex is a powerful tool for neuroscience research, and its use has been extended into the brainstem and spinal cord as well. However, there are significant technical challenges with extrapolating the developments that have been achieved in the cortex to their use i...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.01.038

    authors: Stroman PW,Figley CR,Cahill CM

    更新日期:2008-07-01 00:00:00

  • 3D Slicer as an image computing platform for the Quantitative Imaging Network.

    abstract::Quantitative analysis has tremendous but mostly unrealized potential in healthcare to support objective and accurate interpretation of the clinical imaging. In 2008, the National Cancer Institute began building the Quantitative Imaging Network (QIN) initiative with the goal of advancing quantitative imaging in the con...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.05.001

    authors: Fedorov A,Beichel R,Kalpathy-Cramer J,Finet J,Fillion-Robin JC,Pujol S,Bauer C,Jennings D,Fennessy F,Sonka M,Buatti J,Aylward S,Miller JV,Pieper S,Kikinis R

    更新日期:2012-11-01 00:00:00

  • Artificial intelligence in medical imaging.

    abstract::The medical specialty radiology has experienced a number of extremely important and influential technical developments in the past that have affected how medical imaging is deployed. Artificial intelligence (AI) is potentially another such development that will introduce fundamental changes into the practice of radiol...

    journal_title:Magnetic resonance imaging

    pub_type: 社论

    doi:10.1016/j.mri.2019.12.006

    authors: Gore JC

    更新日期:2020-05-01 00:00:00

  • Combination of integrated dynamic shimming and readout-segmented echo planar imaging for diffusion weighted MRI of the head and neck region at 3Tesla.

    abstract:PURPOSE:To evaluate the performance of combined integrated slice-by-slice shimming and readout-segmented EPI (irsEPI) for diffusion-weighted MR imaging (DWI) of the neck at 3Tesla. METHODS:This study was approved by the local ethics committee. An anthropometric phantom of the head/neck region incorporating compartment...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.05.004

    authors: Walter SS,Liu W,Stemmer A,Martirosian P,Nikolaou K,Notohamiprodjo M,Gatidis S

    更新日期:2017-10-01 00:00:00

  • MR angiography of meningioma.

    abstract::The clinical evaluation of three-dimensional time-of-flight MR angiography was prospectively performed in 16 patients with intracranial meningioma. MR angiographic techniques used in this study both with and without gadopentetate dimeglumine made it possible to demonstrate the topographic relationship between the tumo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90466-q

    authors: Kadota T,Kuriyama K,Inoue E,Fujita M,Nakagawa H,Kuroda C

    更新日期:1993-01-01 00:00:00

  • Compensation of susceptibility-induced signal loss in echo-planar imaging for functional applications.

    abstract::Functional magnetic resonance imaging favors the use of multi-slice gradient-recalled echo-planar imaging due to its short image acquisition times, whole brain coverage and sensitivity to BOLD contrast. However, despite its advantages, gradient-recalled echo-planar imaging also is sensitive to static magnetic field gr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00199-5

    authors: Cordes D,Turski PA,Sorenson JA

    更新日期:2000-11-01 00:00:00

  • Accuracy and precision of quantitative DCE-MRI parameters: How should one estimate contrast concentration?

    abstract:INTRODUCTION:Pharmacokinetic parameters derived from dynamic contrast-enhanced MRI (DCE-MRI) data are sensitive to acquisition and post-processing techniques, which makes it difficult to compare results obtained using different methods. In particular, one of the most important factors affecting estimation of model para...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.05.007

    authors: Wake N,Chandarana H,Rusinek H,Fujimoto K,Moy L,Sodickson DK,Kim SG

    更新日期:2018-10-01 00:00:00