Synthesis of magnetic gradients for NMR tomography.

Abstract:

:A numerical method is applied to calculate an optimal distribution of currents in air which generate the magnetic field gradients required to spatially encode the radiofrequency signal in a NMR tomographic experiment. We compare the performances of the gradient circuits for the whole body air-core electromagnet described by Bangert and Mansfield (J. Phys. E 15; 1982) with the results of our optimization.

journal_name

Magn Reson Imaging

authors

Mustarelli P,Rudnicki M,Savini A,Savoldi F,Villa M

doi

10.1016/0730-725x(90)90242-t

subject

Has Abstract

pub_date

1990-01-01 00:00:00

pages

101-5

issue

2

eissn

0730-725X

issn

1873-5894

pii

0730-725X(90)90242-T

journal_volume

8

pub_type

杂志文章
  • Real-time animal functional magnetic resonance imaging and its application to neuropharmacological studies.

    abstract::In pharmacological magnetic resonance imaging (phMRI) with anesthetized animals, there is usually only a single time window to observe the dynamic signal change to an acute drug administration since subsequent drug injections are likely to result in altered response properties (e.g., tolerance). Unlike the block-desig...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.02.020

    authors: Lu H,Yang S,Zuo Y,Demny S,Stein EA,Yang Y

    更新日期:2008-11-01 00:00:00

  • Clinical implementation of a multislice high spectral and spatial resolution-based MRI sequence to achieve unilateral full-breast coverage.

    abstract::High-resolution, single-slice, high spatial and spectral resolution (HiSS) breast magnetic resonance imaging (MRI) provides improved lesion conspicuity, margin definition and internal definition, as compared to conventional clinical MRI - and thus may provide better lesion characterization and increase breast MRI spec...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.022

    authors: Medved M,Newstead GM,Abe H,Olopade OI,Shimauchi A,Zamora MA,Karczmar GS

    更新日期:2010-01-01 00:00:00

  • MAgnitude and PHase Thresholding (MAPHT) of noisy complex-valued magnetic resonance images.

    abstract::It is often desirable to separate voxels that contain signal from tissue along with measurement noise from those that contain purely measurement noise. Generally, this separation called thresholding utilizes only the magnitude portion of the images. Recently, methods have been developed that utilize both the magnitude...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.008

    authors: Rowe DB,Haacke EM

    更新日期:2009-11-01 00:00:00

  • DUSTER: dynamic contrast enhance up-sampled temporal resolution analysis method.

    abstract::Dynamic contrast enhanced (DCE) MRI using Tofts' model for estimating vascular permeability is widely accepted, yet inter-tissue differences in bolus arrival time (BAT) are generally ignored. In this work we propose a method, incorporating the BAT in the analysis, demonstrating its applicability and advantages in heal...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.12.014

    authors: Liberman G,Louzoun Y,Artzi M,Nadav G,Ewing JR,Ben Bashat D

    更新日期:2016-05-01 00:00:00

  • Quantification of synovistis by MRI: correlation between dynamic and static gadolinium-enhanced magnetic resonance imaging and microscopic and macroscopic signs of synovial inflammation.

    abstract::Dynamic and static gadolinium-diethylenetriaminepentaacetic acid(Gd-DTPA)-enhanced magnetic resonance imaging (MRI) were evaluated as measures of joint inflammation in arthritis, by a comparison with macroscopic and microscopic signs of synovitis. Furthermore, the importance of the size of the evaluated synovial areas...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00008-3

    authors: Ostergaard M,Stoltenberg M,Løvgreen-Nielsen P,Volck B,Sonne-Holm S,Lorenzen I

    更新日期:1998-09-01 00:00:00

  • A simple way to acquire T(1)-weighted MR images of rat liver with respiratory triggering.

    abstract::To acquire high-resolution T(1)-weighted images of the liver in rats, for which breath-holding cannot be ensured, respiratory triggering is essential. At the respiratory rate of 30-60 times/min in rats, however, T(1)-weighted images cannot be obtained with simple triggering. As a simple solution to this, we applied mu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.10.005

    authors: Morikawa S,Murayama H,Fujimoto S,Shiino A,Inubushi T

    更新日期:2012-04-01 00:00:00

  • The prospects for high resolution optical brain imaging: the magnetic resonance perspective.

    abstract::Various analogs of NMR and MRI are now technically possible in optics; specifically, high-resolution laser-pulse shaping and complex pulse sequence generation with well-defined phase shifts has been demonstrated. Here we summarize this technology and discuss the potential for these methods to enhance optical functiona...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.08.024

    authors: Warren WS,Wagner W,Ye T

    更新日期:2003-12-01 00:00:00

  • Rapid acquisition strategy for functional T1ρ mapping of the brain.

    abstract::Functional T1ρ mapping has been proposed as a method to assess pH and metabolism dynamics in the brain with high spatial and temporal resolution. The purpose of this work is to describe and evaluate a variant of the spin-locked echo-planar imaging sequence for functional T1ρ mapping at 3T. The proposed sequence rapidl...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.07.010

    authors: Johnson CP,Heo HY,Thedens DR,Wemmie JA,Magnotta VA

    更新日期:2014-11-01 00:00:00

  • Diffusional kurtosis imaging of cingulate fibers in Parkinson disease: comparison with conventional diffusion tensor imaging.

    abstract:OBJECTIVE:The pathological changes in Parkinson disease begin in the brainstem; reach the limbic system and ultimately spread to the cerebral cortex. In Parkinson disease (PD) patients, we evaluated the alteration of cingulate fibers, which comprise part of the limbic system, by using diffusional kurtosis imaging (DKI)...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.06.009

    authors: Kamagata K,Tomiyama H,Motoi Y,Kano M,Abe O,Ito K,Shimoji K,Suzuki M,Hori M,Nakanishi A,Kuwatsuru R,Sasai K,Aoki S,Hattori N

    更新日期:2013-11-01 00:00:00

  • Quantitative SENSE-MRSI of the human brain.

    abstract:PURPOSE:To develop a method for estimating metabolite concentrations using phased-array coils and sensitivity-encoded (SENSE) magnetic resonance spectroscopic images (MRSI) of the human brain. MATERIALS AND METHODS:The method is based on the phantom replacement technique and uses receive coil sensitivity maps and body...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.11.003

    authors: Bonekamp D,Smith MA,Zhu H,Barker PB

    更新日期:2010-04-01 00:00:00

  • Proton electron double resonance imaging of free radical distribution in environmental science applications--first results and perspectives.

    abstract::In this contribution, we explore the potential of proton electron double resonance imaging (PEDRI) in environmental science (hydrogeological) applications. After a discussion of the hydrogeological motivation for studies of free radical transport in environmental matrices, we present results from first experiments tha...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.11.027

    authors: Nestle N,Shet K,Lurie DJ

    更新日期:2005-02-01 00:00:00

  • Assessment of normal flow patterns in the pulmonary circulation by using 4D magnetic resonance velocity mapping.

    abstract:OBJECTIVE:The purpose of this study was to analyze flow patterns in the pulmonary circulation of healthy volunteers by using 4D flow magnetic resonance imaging. MATERIALS AND METHODS:The study was approved by the local ethics committee and all subjects gave written informed consent. Eighteen volunteers underwent a 4D ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.036

    authors: Bächler P,Pinochet N,Sotelo J,Crelier G,Irarrazaval P,Tejos C,Uribe S

    更新日期:2013-02-01 00:00:00

  • Initial clinical evaluation of gadolinium DTPA for contrast-enhanced magnetic resonance imaging.

    abstract::Gadolinium DTPA was evaluated as an intravenous contrast agent for magnetic resonance imaging in 15 patients with primary or secondary intracranial neoplastic disease. T1 and T2 weighted images were obtained prior to contrast administration. T1 weighted spin echo 35/800 (TE/TR) images were utilized to detect enhanceme...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(85)90006-2

    authors: Runge VM,Schoerner W,Niendorf HP,Laniado M,Koehler D,Claussen C,Felix R,James AE Jr

    更新日期:1985-01-01 00:00:00

  • Fast multi-contrast MRI reconstruction.

    abstract::Multi-contrast magnetic resonance imaging (MRI) is a useful technique to aid clinical diagnosis. This paper proposes an efficient algorithm to jointly reconstruct multiple T1/T2-weighted images of the same anatomical cross section from partially sampled k-space data. The joint reconstruction problem is formulated as m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.08.025

    authors: Huang J,Chen C,Axel L

    更新日期:2014-12-01 00:00:00

  • N-acetylaspartate reductions measured by 1H MRSI in cognitively impaired HIV-seropositive individuals.

    abstract::We used magnetic resonance imaging (MRI) and water-suppressed proton MR spectroscopic imaging (1H MRSI) to study the effects of human immunodeficiency virus (HIV) infection on the brain. Our recent in vivo finding of lower N-acetylaspartate (NAA), a putative marker of neurons, in the supraventricular brain of cognitiv...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92460-0

    authors: Meyerhoff DJ,MacKay S,Poole N,Dillon WP,Weiner MW,Fein G

    更新日期:1994-01-01 00:00:00

  • In vivo measurement of diffusion and pseudo-diffusion in skeletal muscle at rest and after exercise.

    abstract::To investigate whether diffusion-related compartmentalization could be observed in skeletal muscle and whether this compartmentalization was affected by exercising, attenuation curves of signal against diffusion weighting were obtained in skeletal muscle of nine healthy volunteers at rest and after an exercise. Fiftee...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)00096-l

    authors: Morvan D

    更新日期:1995-01-01 00:00:00

  • COmplex-Model-Based Estimation of thermal noise for fMRI data in the presence of artifacts.

    abstract::Due to the presence of artifacts induced by fast-imaging acquisition in functional magnetic resonance imaging (fMRI) studies, it is very difficult to estimate the variance of thermal noise by traditional methods in magnitude images. Moreover, the existence of incidental phase fluctuations impairs the validity of curre...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.12.007

    authors: Xu Y,Wu G,Rowe DB,Ma Y,Zhang R,Xu G,Li SJ

    更新日期:2007-09-01 00:00:00

  • Optimal real-time estimation in diffusion tensor imaging.

    abstract::Diffusion tensor imaging (DTI) constitutes the most used paradigm among the diffusion-weighted magnetic resonance imaging (DW-MRI) techniques due to its simplicity and application potential. Recently, real-time estimation in DW-MRI has deserved special attention, with several proposals aiming at the estimation of mean...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.12.001

    authors: Casaseca-de-la-Higuera P,Tristán-Vega A,Aja-Fernández S,Alberola-López C,Westin CF,San José Estépar R

    更新日期:2012-05-01 00:00:00

  • Analysis of kinetic curve and model-based perfusion parameters on dynamic contrast enhanced MRI in breast cancer patients: Correlations with dominant stroma type.

    abstract:OBJECTIVE:Our purpose was to evaluate imaging findings of breast cancers according to the dominant stroma type by using kinetic curve analysis and model-based perfusion parameters from dynamic contrast-enhanced magnetic resonance imaging. METHODS:From March 2011 to September 2011, 64 cancers in 64 patients were includ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.07.010

    authors: Yim H,Kang DK,Jung YS,Jeon GS,Kim TH

    更新日期:2016-01-01 00:00:00

  • Noise estimation in single- and multiple-coil magnetic resonance data based on statistical models.

    abstract::Noise estimation is a challenging task in magnetic resonance imaging (MRI), with applications in quality assessment, filtering or diffusion tensor estimation. Main noise estimators based on the Rician model are revisited and classified in this article, and new useful methods are proposed. Additionally, all the surveye...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.025

    authors: Aja-Fernández S,Tristán-Vega A,Alberola-López C

    更新日期:2009-12-01 00:00:00

  • Identification of an optimal threshold for detecting human brown adipose tissue using receiver operating characteristic analysis of IDEAL MRI fat fraction maps.

    abstract:PURPOSE:Lower fat fraction (FF) in brown adipose tissue (BAT) than white adipose tissue (WAT) has been exploited using Dixon-based Magnetic Resonance Imaging (MRI) to differentiate these tissues in rodents, human infants and adults. We aimed to determine whether an optimal FF threshold could be determined to differenti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.04.013

    authors: Jones TA,Wayte SC,Reddy NL,Adesanya O,Dimitriadis GK,Barber TM,Hutchinson CE

    更新日期:2018-09-01 00:00:00

  • Rapid whole-brain quantitative magnetization transfer imaging using 3D selective inversion recovery sequences.

    abstract::Selective inversion recovery (SIR) is a quantitative magnetization transfer (qMT) method that provides estimates of parameters related to myelin content in white matter, namely the macromolecular pool-size-ratio (PSR) and the spin-lattice relaxation rate of the free pool (R1f), without the need for independent estimat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.01.014

    authors: Cronin MJ,Xu J,Bagnato F,Gochberg DF,Gore JC,Dortch RD

    更新日期:2020-05-01 00:00:00

  • Pulseq-Graphical Programming Interface: Open source visual environment for prototyping pulse sequences and integrated magnetic resonance imaging algorithm development.

    abstract:PURPOSE:To provide a single open-source platform for comprehensive MR algorithm development inclusive of simulations, pulse sequence design and deployment, reconstruction, and image analysis. METHODS:We integrated the "Pulseq" platform for vendor-independent pulse programming with Graphical Programming Interface (GPI)...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.03.008

    authors: Ravi KS,Potdar S,Poojar P,Reddy AK,Kroboth S,Nielsen JF,Zaitsev M,Venkatesan R,Geethanath S

    更新日期:2018-10-01 00:00:00

  • Effects of osmotic manipulation of intracellular hydration of HeLa S-3 cells on their proton NMR relaxation times.

    abstract::Pellets of HeLa from suspension cultured cells in isotonic medium (300 mosmolar) were introduced into a Bruker CXP100 NMR spectrophotometer at 80 mHz within 5 min of the start of centrifugation. T1 and T2 times were measured within a total elapsed time of 20-25 min at 80 mHz and 37 degrees C, and averaged 1430 msec an...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90101-7

    authors: Wheatley DN,Rimmington JE,Foster MA

    更新日期:1990-01-01 00:00:00

  • Effect of anesthesia on the signal intensity in tumors using BOLD-MRI: comparison with flow measurements by Laser Doppler flowmetry and oxygen measurements by luminescence-based probes.

    abstract::BOLD-contrast functional magnetic resonance imaging (MRI) was used to assess the evolution of tumor oxygenation and blood flow after administration of four different anesthetics: pentobarbital (60 mg/kg), ketamine/xylazine (80/8 mg/kg), fentanyl/droperidol (0.078/3.9 mg/kg), and isoflurane (1.5%). Gradient echo sequen...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.02.005

    authors: Baudelet C,Gallez B

    更新日期:2004-09-01 00:00:00

  • Investigations of polymer dynamics in nanoporous media by field cycling NMR relaxometry and the dipolar correlation effect.

    abstract::The chain dynamics of short-chain perfluoropolyether melts confined in Vycor nanoporous media has been characterized by field cycling nuclear magnetic resonance relaxometry and the dipolar correlation effect. The slowdown of motions under confinement, leading to larger residual dipolar couplings, has been probed by lo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.11.018

    authors: Kausik R,Fatkullin N,Hüsing N,Kimmich R

    更新日期:2007-05-01 00:00:00

  • Gd-EOB-DTPA-enhanced-MR imaging in the inflammation stage of nonalcoholic steatohepatitis (NASH) in mice.

    abstract:OBJECTIVE:The purpose of this study is to investigate the correlation between the liver kinetics of gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) and liver histopathology in a mouse model of NASH by using dynamic contrast-enhanced MRI. MATERIALS AND METHODS:Twenty male C57/BL6 mice aged 8we...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.03.009

    authors: Yamada T,Obata A,Kashiwagi Y,Rokugawa T,Matsushima S,Hamada T,Watabe H,Abe K

    更新日期:2016-07-01 00:00:00

  • Three-dimensional adiabatic inversion recovery prepared ultrashort echo time cones (3D IR-UTE-Cones) imaging of cortical bone in the hip.

    abstract:PURPOSE:We present three-dimensional adiabatic inversion recovery prepared ultrashort echo time Cones (3D IR-UTE-Cones) imaging of cortical bone in the hip of healthy volunteers using a clinical 3T scanner. METHODS:A 3D IR-UTE-Cones sequence, based on a short pulse excitation followed by a 3D Cones trajectory, with a ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.07.012

    authors: Nazaran A,Carl M,Ma Y,Jerban S,Zhu Y,Lu X,Du J,Chang EY

    更新日期:2017-12-01 00:00:00

  • 3D MR image denoising using rough set and kernel PCA method.

    abstract::In this paper, we have presented a two stage method, using kernel principal component analysis (KPCA) and rough set theory (RST), for denoising volumetric MRI data. A rough set theory (RST) based clustering technique has been used for voxel based processing. The method groups similar voxels (3D cubes) using class and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.10.010

    authors: Phophalia A,Mitra SK

    更新日期:2017-02-01 00:00:00

  • Analysis of microporosity and setting of reactive powder concrete by proton nuclear relaxation.

    abstract::The proton spin-lattice relaxation measured at several frequencies leads to a resolved distribution of four Tli for reactive powder concrete (RPC). The typical Tli frequency dependences are quantitatively interpreted by a biphasic fast exchange model and a proton nuclear relaxation of hydrated paramagnetic ions at the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00063-0

    authors: Philippot S,Korb JP,Petit D,Zanni H

    更新日期:1998-06-01 00:00:00