Accuracy and precision of quantitative DCE-MRI parameters: How should one estimate contrast concentration?

Abstract:

INTRODUCTION:Pharmacokinetic parameters derived from dynamic contrast-enhanced MRI (DCE-MRI) data are sensitive to acquisition and post-processing techniques, which makes it difficult to compare results obtained using different methods. In particular, one of the most important factors affecting estimation of model parameters is how to convert MRI signal intensities to contrast agent concentration. The purpose of our study was to quantitatively compare a linear signal-to-concentration conversion (LC) as an approximation and a non-linear conversion (NLC) based on the MRI signal equation, in terms of the accuracy and precision of the pharmacokinetic parameters in T1-weighted DCE-MRI. MATERIALS AND METHODS:Numerical simulation studies were conducted to compare LC and NLC in terms of the accuracy and precision in contrast kinetic parameter estimation, and to evaluate their dependency on flip angle (FA), pre-contrast T1 (T10) and arterial input function (AIF). In addition, the effect of the conversion method on the diagnostic accuracy was evaluated with 36 breast lesions (19 benign and 17 malignant). RESULTS:The transfer rate (Ktrans) estimated using LC and measured AIF (mAIF) were up to 38% higher than the true Ktrans values, while the LC Ktrans estimates with the presumed AIF (pAIF) were up to 7% lower than the true Ktrans values, when FA = 45°. When using a small FA, such as 12°, the LC Ktrans with pAIF had least sensitivity to the error in T10 compared to the Ktrans estimated using LC with mAIF, and NLC with pAIF or mAIF. The breast DCE-MRI study showed that both LC and NLC Ktrans were significantly different (p < 0.05) between the malignant and benign lesions. The effect size between benign and malignant values as measured by Cohen's d was 1.06 for LC Ktrans and 1.02 for NLC Ktrans. CONCLUSION:The present study results show that, when precontrast T1 measurement is not available and a low FA is used for DCE-MRI, the uncertainty in the contrast kinetic parameter estimation can be reduced by using the LC method with pAIF, without compromising the diagnostic accuracy.

journal_name

Magn Reson Imaging

authors

Wake N,Chandarana H,Rusinek H,Fujimoto K,Moy L,Sodickson DK,Kim SG

doi

10.1016/j.mri.2018.05.007

subject

Has Abstract

pub_date

2018-10-01 00:00:00

pages

16-23

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(18)30140-1

journal_volume

52

pub_type

杂志文章
  • MRI observation of heavy metal transport in aquifer matrices down to sub-mg quantities.

    abstract::In this contribution, we report results from MRI studies of the propagation of heavy metal ions through columns packed with sandy aquifer materials. Both sorption of low concentrations of heavy metal ions from water flowing through the column and the formation of sorption traces produced from initially localized highe...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00166-8

    authors: Nestle N,Baumann T,Wunderlich A,Niessner R

    更新日期:2003-04-01 00:00:00

  • Assessment of transplant renal artery stenosis with diffusion-weighted imaging: A preliminary study.

    abstract:OBJECTIVE:To characterize capillary perfusion and tissue diffusion changes in transplant renal artery stenosis (TRAS) with diffusion-weighted imaging (DWI). MATERIALS & METHODS:We retrospectively identified 30 patients with non-contrast enhanced magnetic resonance angiography-proven TRAS. Another 20 kidney transplant ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.05.007

    authors: Fan M,Ni X,Li Y,Chen J,Cheng D,Shi D,He X,Wen J

    更新日期:2019-07-01 00:00:00

  • Drug monitoring of 5-fluorouracil: in vivo 19F NMR study during 5-FU chemotherapy in patients with metastases of colorectal adenocarcinoma.

    abstract::The metabolism of 5-fluorouracil (5-FU) is complex and the reason for the low response rate of tumor patients to 5-FU is currently unknown. The aim of this study was to evaluate whether spectral parameters obtained noninvasively by in vivo 19F nuclear magnetic resonance (NMR) spectroscopy can be used to assess individ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92544-5

    authors: Schlemmer HP,Bachert P,Semmler W,Hohenberger P,Schlag P,Lorenz WJ,van Kaick G

    更新日期:1994-01-01 00:00:00

  • Early assessment of breast cancer response to neoadjuvant chemotherapy by semi-quantitative analysis of high-temporal resolution DCE-MRI: preliminary results.

    abstract:PURPOSE:To evaluate whether semi-quantitative analysis of high temporal resolution dynamic contrast-enhanced MRI (DCE-MRI) acquired early in treatment can predict the response of locally advanced breast cancer (LABC) to neoadjuvant chemotherapy (NAC). MATERIALS AND METHODS:As part of an IRB-approved prospective study,...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.mri.2013.07.002

    authors: Abramson RG,Li X,Hoyt TL,Su PF,Arlinghaus LR,Wilson KJ,Abramson VG,Chakravarthy AB,Yankeelov TE

    更新日期:2013-11-01 00:00:00

  • MAgnitude and PHase Thresholding (MAPHT) of noisy complex-valued magnetic resonance images.

    abstract::It is often desirable to separate voxels that contain signal from tissue along with measurement noise from those that contain purely measurement noise. Generally, this separation called thresholding utilizes only the magnitude portion of the images. Recently, methods have been developed that utilize both the magnitude...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.008

    authors: Rowe DB,Haacke EM

    更新日期:2009-11-01 00:00:00

  • Event-related fMRI of auditory and visual oddball tasks.

    abstract::Functional magnetic resonance imaging (fMRI) was used to investigate the spatial distribution of cortical activation in frontal and parietal lobes during auditory and visual oddball tasks in 10 healthy subjects. The purpose of the study was to compare activation within auditory and visual modalities and identify commo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00128-4

    authors: Stevens AA,Skudlarski P,Gatenby JC,Gore JC

    更新日期:2000-06-01 00:00:00

  • CPMG relaxation rate dispersion in dipole fields around capillaries.

    abstract::Transverse relaxation rates for Carr-Purcell-Meiboom-Gill (CPMG) sequences increase with inter-echo time in presence of microscopic magnetic field inhomogeneities due to nuclear spin diffusion. For a weak field approximation that includes diffusion effects, the CPMG relaxation rate shift for proton diffusion around ca...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.03.016

    authors: Kurz FT,Kampf T,Buschle LR,Heiland S,Schlemmer HP,Bendszus M,Ziener CH

    更新日期:2016-09-01 00:00:00

  • Ovarian Brenner tumors: MR imaging characteristics.

    abstract::This study describes the appearance of Brenner tumors on MR imaging and compares quantitative signal intensity measurements of Brenner tumors with that of other ovarian tumors. A search of pathologic and MR records disclosed patients who had MRIs showing Brenner tumors prior to surgical excision. Patients (21) with ot...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0730-725x(98)00136-2

    authors: Outwater EK,Siegelman ES,Kim B,Chiowanich P,Blasbalg R,Kilger A

    更新日期:1998-12-01 00:00:00

  • Spine MR images in patients with pedicle screw fixation: Comparison of conventional and SEMAC-VAT sequences at 1.5 T.

    abstract:BACKGROUND AND PURPOSE:Slice-encoding metal artifact corrections (SEMAC)-view-angle tilting (VAT) sequences have recently been used in clinical protocols to reduce metal artifacts in MR scans of patients with spinal instrumentation. The objective of this study was to compare the SEMAC-VAT sequence with the conventional...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.08.002

    authors: Park C,Lee E,Yeo Y,Kang Y,Lee JW,Ahn JM,Kang HS

    更新日期:2018-12-01 00:00:00

  • Diffusion MRI detects longitudinal white matter changes in the 3xTg-AD mouse model of Alzheimer's disease.

    abstract::The sensitivity of multiple diffusion MRI (dMRI) parameters to longitudinal changes in white matter microstructure was investigated for the 3xTg-AD transgenic mouse model of Alzheimer's disease, which manifests both amyloid beta plaques and neurofibrillary tangles. By employing a specific dMRI method known as diffusio...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.12.003

    authors: Nie X,Falangola MF,Ward R,McKinnon ET,Helpern JA,Nietert PJ,Jensen JH

    更新日期:2019-04-01 00:00:00

  • In vitro adrenal cortex lesions characterization by NMR spectroscopy.

    abstract::Percentage of lipid content of 22 adrenal cortex lesions and their water proton longitudinal relaxation time were measured in vitro at 60 MHz. Although water relaxation times obtained on benign and malignant samples overlap each other, measurements of the percentage of lipids performed on the same tissues allow us to ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90123-8

    authors: Leroy-Willig A,Roucayrol JC,Luton JP,Courtieu J,Niesenbaum N,Louvel A

    更新日期:1987-01-01 00:00:00

  • Spectral pattern of total creatine and trimethyl ammonium in multiple sclerosis.

    abstract::Fatigue and impairment mobility are frequent problems in multiple sclerosis (MS). Despite its enormous potential, in vivo (1)H MRS of skeletal muscles for MS patients is a largely unexplored field. One fundamental question remains unanswered: whether MS can cause observable proton metabolite changes. High quality two-...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.005

    authors: Hu J,Xu Y,Jiang Q,Sehgal V,Shen Y,Xuan Y,Xia Y

    更新日期:2004-04-01 00:00:00

  • Muscle and fat quantification in MRI gradient echo images using a partial volume detection method. Application to the characterization of pig belly tissue.

    abstract::Complete dissection is the current reference method to quantify muscle and fat tissue on pig carcasses. Magnetic resonance imaging (MRI) is an appropriate nondestructive alternative method that can provide reliable and quantitative information on pig carcass composition without losing the spatial information. We have ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.05.001

    authors: Monziols M,Collewet G,Mariette F,Kouba M,Davenel A

    更新日期:2005-07-01 00:00:00

  • Single-sided mobile NMR with a Halbach magnet.

    abstract::A single-sided mobile NMR apparatus with a small Halbach magnet was constructed for the first time. It is lightweight, compact and exhibits good sensitivity. The weight of the device is only 2 kg, and the NMR signal of the pencil eraser block can be detected in one shot using the device. This study describes the chara...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.04.005

    authors: Chang WH,Chen JH,Hwang LP

    更新日期:2006-10-01 00:00:00

  • "MR conditional" respiratory ventilator system incident in a 3-T MRI environment.

    abstract::The misunderstanding of the labeling for an "MR conditional" respiratory ventilator system resulted in the placement of this device, which had substantial ferromagnetic components, too close to a 3-T magnetic resonance (MR) system, causing a projectile incident. Magnetic resonance imaging health care professionals sho...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.07.002

    authors: Greenberg KL,Weinreb J,Shellock FG

    更新日期:2011-10-01 00:00:00

  • Relationship between neural and hemodynamic signals during spontaneous activity studied with temporal kernel CCA.

    abstract::Functional magnetic resonance imaging (fMRI) based on the so-called blood oxygen level-dependent (BOLD) contrast is a powerful tool for studying brain function not only locally but also on the large scale. Most studies assume a simple relationship between neural and BOLD activity, in spite of the fact that it is impor...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.12.016

    authors: Murayama Y,Biessmann F,Meinecke FC,Müller KR,Augath M,Oeltermann A,Logothetis NK

    更新日期:2010-10-01 00:00:00

  • Quantitative evaluation of porous media wettability using NMR relaxometry.

    abstract::We propose a new method to determine wettability indices from NMR relaxometry. The new method uses the sensitivity of low field NMR relaxometry to the fluid distribution in oil-water saturated porous media. The model is based on the existence of a surface relaxivity for both oil and water, allowing the determination o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00145-0

    authors: Fleury M,Deflandre F

    更新日期:2003-04-01 00:00:00

  • MRI-guided breast vacuum biopsy: Localization of the lesion without contrast-agent application using diffusion-weighted imaging.

    abstract:OBJECTIVE:In magnetic resonance-guided breast vacuum biopsies, the contrast agent for targeting suspicious lesions can typically be applied only once during an intervention, due to the slow elimination of the gadolinium chelate from the extracellular fluid space. This study evaluated the feasibility of diffusion-weight...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.12.006

    authors: Berger N,Varga Z,Frauenfelder T,Boss A

    更新日期:2017-05-01 00:00:00

  • Liposomal Gd-DTPA: effect of encapsulation on enhancement of hepatoma model by MRI.

    abstract::Liposomes entrapping gadolinium-DTPA (Gd-DTPA) were synthesized from 60 mole percent egg phosphatidylcholine (EPC) and 40 mole percent cholesterol or EPC alone entrapping Gd-DTPA in diameters of 100 and 200 nm. Rats bearing Morris hepatoma in their flanks were imaged by MR pre- and post-contrast with free Gd-DTPA and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90491-8

    authors: Unger EC,MacDougall P,Cullis P,Tilcock C

    更新日期:1989-07-01 00:00:00

  • Analysis of machine-dependent and object-induced geometric distortion in 2DFT MR imaging.

    abstract::Geometric distortion in MR imaging predominantly arises from the inhomogeneity of the static field and the nonlinearity of the gradients. It is the purpose of this paper to analyse the object and machine related contributions to geometric distortion in order to determine which corrections are necessary for attaining a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90011-n

    authors: Bakker CJ,Moerland MA,Bhagwandien R,Beersma R

    更新日期:1992-01-01 00:00:00

  • Magnetic resonance T2* measurements of the normal human lung in vivo with ultra-short echo times.

    abstract::The objective of this study was to measure T2* values of the normal human lung in vivo during breathhold using a rapid gradient-echo sequence with ultra-short echo times (TE). A sagittal slice of the right lung was imaged in six volunteers with various TE ranging from 0.5 ms to 5 ms using a clinical 1.5 Tesla MR scann...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00047-8

    authors: Stock KW,Chen Q,Hatabu H,Edelman RR

    更新日期:1999-09-01 00:00:00

  • Chemical exchange saturation transfer MR imaging of articular cartilage glycosaminoglycans at 3 T: Accuracy of B0 Field Inhomogeneity corrections with gradient echo method.

    abstract::Glycosaminoglycan Chemical Exchange Saturation Transfer (gagCEST) is an important molecular MRI methodology developed to assess changes in cartilage GAG concentrations. The correction for B0 field inhomogeneity is technically crucial in gagCEST imaging. This study evaluates the accuracy of the B0 estimation determined...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.07.009

    authors: Wei W,Jia G,Flanigan D,Zhou J,Knopp MV

    更新日期:2014-01-01 00:00:00

  • Adaptive segmentation of magnetic resonance images with intensity inhomogeneity using level set method.

    abstract::It is a big challenge to segment magnetic resonance (MR) images with intensity inhomogeneity. The widely used segmentation algorithms are region based, which mostly rely on the intensity homogeneity, and could bring inaccurate results. In this paper, we propose a novel region-based active contour model in a variationa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.10.010

    authors: Liu L,Zhang Q,Wu M,Li W,Shang F

    更新日期:2013-05-01 00:00:00

  • Interpretation of restricted diffusion in sandstones with internal field gradients.

    abstract::We report on experiments to characterize internal magnetic field gradients that are caused by magnetic susceptibility differences between the solid phase and the fluids filling the pore space. Our measurements focus on low-field relaxometry of brine and oil in sandstones from various reservoirs around the world. Our r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00287-9

    authors: Appel M,Freeman JJ,Gardner JS,Hirasaki GH,Zhang QG,Shafer JL

    更新日期:2001-04-01 00:00:00

  • Perfusion imaging by un-inverted flow-sensitive alternating inversion recovery (UNFAIR).

    abstract::A new pulse sequence for estimating cerebral blood flow called UNFAIR, which uses a combination of sequential hyperbolic secant preparatory pulses, is introduced. This sequence is based on the same generalized conditions as previously introduced inversion recovery techniques except that the spins in the image slice of...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00353-0

    authors: Helpern JA,Branch CA,Yongbi MN,Huang NC

    更新日期:1997-01-01 00:00:00

  • Measurements of RF heating during 3.0-T MRI of a pig implanted with deep brain stimulator.

    abstract:PURPOSE:To present preliminary, in vivo temperature measurements during MRI of a pig implanted with a deep brain stimulation (DBS) system. MATERIALS AND METHODS:DBS system (Medtronic Inc., Minneapolis, MN) was implanted in the brain of an anesthetized pig. 3.0-T MRI was performed with a T/R head coil using the low-SAR...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.11.005

    authors: Gorny KR,Presti MF,Goerss SJ,Hwang SC,Jang DP,Kim I,Min HK,Shu Y,Favazza CP,Lee KH,Bernstein MA

    更新日期:2013-06-01 00:00:00

  • A method for imaging of chemical shift or magnetic field distributions.

    abstract::A phase encoding method for imaging of chemical shift or magnetic field distributions is described. The method utilizes the spin-echo principle and the time period between signal collection and excitation is constant but the time period between excitation and the 180 degrees pulse is varied by constant steps. The meth...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(85)90253-x

    authors: Sepponen RE

    更新日期:1985-01-01 00:00:00

  • Lee-Goldburg solid-state imaging.

    abstract::A new approach to solid-state imaging (SSI) is presented. The method relies on narrowing the resonance line using the Lee-Goldburg sequence. The technique is easy to implement in practice and may find widespread applications in materials science. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90409-s

    authors: De Luca F,Lugeri N,De Simone BC,Maraviglia B

    更新日期:1992-01-01 00:00:00

  • Non-enhanced magnetic resonance imaging of the small bowel at 7 Tesla in comparison to 1.5 Tesla: First steps towards clinical application.

    abstract:OBJECTIVE:To perform non-enhanced (NE) magnetic resonance imaging (MRI) of the small bowel at 7 Tesla (7T) and to compare it with 1.5 Tesla (1.5T). MATERIAL AND METHODS:Twelve healthy subjects were prospectively examined using a 1.5T and 7T MRI system. Coronal and axial true fast imaging with steady-state precession (...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.11.012

    authors: Hahnemann ML,Kraff O,Maderwald S,Johst S,Orzada S,Umutlu L,Ladd ME,Quick HH,Lauenstein TC

    更新日期:2016-06-01 00:00:00

  • In vivo T1 characterization of genetically induced muscle atrophy.

    abstract::In vivo spin-lattice relaxation times, T1, of water and lipid protons of normal and atrophic muscles were measured, using the spatially resolved spectroscopy (SPARS) sequence, in a genetic avian model of myopathy. These T1 values were compared with those of the hypertrophic muscles. Although the water T1 values of mus...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90550-x

    authors: Misra LK,Narayana PA

    更新日期:1989-05-01 00:00:00