Tsallis-Entropy Segmentation through MRF and Alzheimer anatomic reference for Brain Magnetic Resonance Parcellation.

Abstract:

:Quantifying the intracranial tissue volume changes in magnetic resonance imaging (MRI) assists specialists to analyze the effects of natural or pathological changes. Since these changes can be subtle, the accuracy of the automatic compartmentalization method is always criticized by specialists. We propose and then evaluate an automatic segmentation method based on modified q-entropy (Mqe) through a modified Markov Random Field (MMRF) enhanced by Alzheimer anatomic reference (AAR) to provide a high accuracy brain tissues parcellation approach (Mqe-MMRF). We underwent two strategies to evaluate Mqe-MMRF; a simulation of different levels of noise and non-uniformity effect on MRI data (7 subjects) and a set of twenty MRI data available from MRBrainS13 as patient brain tissue segmentation challenge. We accessed eleven quality metrics compared to reference tissues delineations to evaluate Mqe-MMRF. MRI segmentation scores decreased by only 4.6% on quality metrics after noise and non-uniformity simulations of 40% and 9%, respectively. We found significant mean improvements in the metrics of the five training subjects, for whole-brain 0.86%, White Matter 3.20%, Gray Matter 3.99%, and Cerebrospinal Fluid 4.16% (p-values < 0.02) when Mqe-MMRF compared to the other reference methods. We also processed the Mqe-MMRF on 15 evaluation subjects group from MRBrainS13 online challenge, and the results held a higher rank than the reference tools; FreeSurfer, SPM, and FSL. Since the proposed method improved the precision of brain segmentation, specifically, for GM, and thus one can use it in quantitative and morphological brain studies.

journal_name

Magn Reson Imaging

authors

Azimbagirad M,Simozo FH,Senra Filho ACS,Murta Junior LO

doi

10.1016/j.mri.2019.11.002

subject

Has Abstract

pub_date

2020-01-01 00:00:00

pages

136-145

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(19)30355-8

journal_volume

65

pub_type

杂志文章
  • Area of paradoxical signal drop after the administration of superparamagnetic iron oxide on the T2-weighted image of a patient with lymphangitic metastasis of the liver.

    abstract::We report a geographic area of prominent hypointensity in T2-weighted images vs. normal adjacent liver parenchyma in a patient with cholangiocarcinoma and lymphangitic metastasis of the liver after superparamagnetic iron oxide (SPIO) administration. The area showing this prominent signal drop showed Kupffer cell proli...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.10.012

    authors: Lee Y,Lee JS,Kim CM,Jeong JY,Choi JI,Kim MJ

    更新日期:2008-05-01 00:00:00

  • Different magnetic resonance imaging features in two types of nontraumatic rabbit osteonecrosis models.

    abstract::A single injection of high-dose steroid (20 mg/kg) has been reported to induce necrotic lesions in the proximal metaphysis and diaphysis of the rabbit femur. In the rabbit osteonecrosis (ON) model induced by two-dose horse serum injections, contrast-enhanced magnetic resonance imaging (MRI) and T2*-weighted dynamic MR...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.07.001

    authors: Takao M,Sugano N,Nishii T,Sakai T,Nakamura N,Yoshikawa H

    更新日期:2009-02-01 00:00:00

  • Compensation of susceptibility-induced signal loss in echo-planar imaging for functional applications.

    abstract::Functional magnetic resonance imaging favors the use of multi-slice gradient-recalled echo-planar imaging due to its short image acquisition times, whole brain coverage and sensitivity to BOLD contrast. However, despite its advantages, gradient-recalled echo-planar imaging also is sensitive to static magnetic field gr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00199-5

    authors: Cordes D,Turski PA,Sorenson JA

    更新日期:2000-11-01 00:00:00

  • Ferumoxide-enhanced MRI in patients with colorectal cancer and rising CEA: surgical correlation in early recurrence.

    abstract::The purpose of this study was to evaluate the value of Ferumoxide-enhanced magnetic resonance (MR) imaging in the detection of hepatic metastases in high-risk patients treated for colorectal cancer that have rising CEA. We used 19 patients treated previously for colorectal cancer with rising CEA levels underwent an un...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0730-725x(99)00134-4

    authors: Said B,McCart JA,Libutti SK,Choyke PL

    更新日期:2000-04-01 00:00:00

  • Evaluation of stacked resonators to enhance the performance of a surface receive-only array for prostate MRI at 3 Tesla.

    abstract::Prostate MRI is an important tool to diagnose and characterize cancer. High local sensitivity and good parallel imaging performance are of paramount importance for diagnostic quality and efficiency. The purpose of this work was to evaluate stacked resonators as part of a surface receiver array for prostate MRI at 3 Te...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.07.010

    authors: Chacon-Caldera J,Fischer A,Malzacher M,Vetter Y,Davids M,Flöser M,Stumpf C,Schad LR

    更新日期:2018-11-01 00:00:00

  • Echo-shifted multislice EPI for high-speed fMRI.

    abstract::The advantages of event-related functional Magnetic Resonance Imaging (fMRI) and the increasing use of fMRI in cognitive experiments are both driving the development of techniques that allow images sensitive to the blood oxygen level-dependent effect to be acquired at ever-higher temporal resolution. Here, we present ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.030

    authors: Gibson A,Peters AM,Bowtell R

    更新日期:2006-05-01 00:00:00

  • Removal of extracerebral tissues in dual-echo magnetic resonance images via linear scale-space features.

    abstract::The location and masking of the brain and surrounding cerebrospinal fluid (CSF) in two-dimensional (2D) dual-echo fast spin-echo (FSE) magnetic resonance (MR) images of the head is achieved by an automated procedure with a voxel-based computational algorithm. Linear scale-space features are derived from the short-echo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00099-x

    authors: Suckling J,Brammer MJ,Lingford-Hughes A,Bullmore ET

    更新日期:1999-02-01 00:00:00

  • 3D cerebrovascular segmentation combining fuzzy vessel enhancement and level-sets with anisotropic energy weights.

    abstract::The aim of this work is to present and evaluate a level-set segmentation approach with vesselness-dependent anisotropic energy weights, which focuses on the exact segmentation of malformed as well as small vessels from time-of-flight (TOF) magnetic resonance angiography (MRA) datasets. In a first step, a vesselness fi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.07.008

    authors: Forkert ND,Schmidt-Richberg A,Fiehler J,Illies T,Möller D,Säring D,Handels H,Ehrhardt J

    更新日期:2013-02-01 00:00:00

  • Preliminary evaluation of accelerated microscopic diffusional kurtosis imaging (μDKI) in a rodent model of epilepsy.

    abstract:PURPOSE:Our study aimed to develop accelerated microscopic diffusional kurtosis imaging (μDKI) and preliminarily evaluated it in a rodent model of chronic epilepsy. METHODS:We investigated two μDKI acceleration schemes of reduced sampling density and angular range in a phantom and wild-type rats, and further tested μD...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.10.009

    authors: Ji Y,Lu D,Wu L,Qiu B,Song YQ,Sun PZ

    更新日期:2019-02-01 00:00:00

  • Analysis of time reduction methods for magnetic resonance elastography of the brain.

    abstract::Magnetic resonance elastography (MRE) uses a phase-contrast MRI technique to image shear wave propagation in tissue followed by the mathematical inversion of the equations of motion governing tissue mechanics to noninvasively image tissue stiffness. This work investigates the impact of various MR sampling strategies d...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.06.016

    authors: Murphy MC,Glaser KJ,Manduca A,Felmlee JP,Huston J 3rd,Ehman RL

    更新日期:2010-12-01 00:00:00

  • Functional magnetic resonance imaging in a stereotactic setup.

    abstract::The localization of critical structures within the brain is important for the planning of therapeutic strategies. Functional MRI is capable to assess functional response of cortical structures to certain stimuli. The authors present two techniques for functional MRI (fMRI) in a stereotactic set-up. The skull of the pa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)02108-x

    authors: Debus J,Essig M,Schad LR,Wenz F,Baudendistel K,Knopp MV,Engenhart R,Lorenz WJ

    更新日期:1996-01-01 00:00:00

  • Acute effects of exercise on muscle MRI in peripheral arterial occlusive disease.

    abstract::The midcalf muscles of eight patients who had peripheral arterial occlusive disease were evaluated by exercise MRI before and after bypass surgery or percutaneous transluminal angioplasty. MRI showed a high intensity of these muscles, especially the posterior muscles, after exercise in all patients before intervention...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00018-c

    authors: Yoshioka H,Anno I,Kuramoto K,Matsumoto K,Jikuya T,Itai Y

    更新日期:1995-01-01 00:00:00

  • T2* measurements in human brain at 1.5, 3 and 7 T.

    abstract::Measurements have been carried out in six subjects at magnetic fields of 1.5, 3 and 7 T, with the aim of characterizing the variation of T2* with field strength in human brain. Accurate measurement of T2* in the presence of macroscopic magnetic field inhomogeneity is problematic due to signal decay resulting from thro...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.02.014

    authors: Peters AM,Brookes MJ,Hoogenraad FG,Gowland PA,Francis ST,Morris PG,Bowtell R

    更新日期:2007-07-01 00:00:00

  • Electric stimulation fMRI of the perforant pathway to the rat hippocampus.

    abstract::The hippocampal formation is a brain system that is implicated in learning and memory. The major input to the hippocampus arrives from the entorhinal cortex (EC) to the dentate gyrus (DG) through the perforant path. In the present work, we have investigated the functional properties of this connection by concomitantly...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.02.018

    authors: Canals S,Beyerlein M,Murayama Y,Logothetis NK

    更新日期:2008-09-01 00:00:00

  • Measurements of RF heating during 3.0-T MRI of a pig implanted with deep brain stimulator.

    abstract:PURPOSE:To present preliminary, in vivo temperature measurements during MRI of a pig implanted with a deep brain stimulation (DBS) system. MATERIALS AND METHODS:DBS system (Medtronic Inc., Minneapolis, MN) was implanted in the brain of an anesthetized pig. 3.0-T MRI was performed with a T/R head coil using the low-SAR...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.11.005

    authors: Gorny KR,Presti MF,Goerss SJ,Hwang SC,Jang DP,Kim I,Min HK,Shu Y,Favazza CP,Lee KH,Bernstein MA

    更新日期:2013-06-01 00:00:00

  • Effect of off-frequency sampling in magnetic resonance elastography.

    abstract::In magnetic resonance elastography (MRE), shear waves at a certain frequency are encoded through bipolar gradients that switch polarity at a controlled encoding frequency and are offset in time to capture wave propagation using a controlled sampling frequency. In brain MRE, there is a possibility that the mechanical a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.09.017

    authors: Johnson CL,Chen DD,Olivero WC,Sutton BP,Georgiadis JG

    更新日期:2012-02-01 00:00:00

  • High density barium sulphate as an MRI oral contrast.

    abstract::High density barium sulphate suspension was investigated as an oral contrast on MRI. On 30 consecutive subjects, the stomach (in all cases) and the two first portions of the duodenum (in 21 cases) were filled with the suspension. This oral contrast behaved as a negative contrast, being hypointense on all pulse sequenc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90019-i

    authors: Marti-Bonmati L,Vilar J,Paniagua JC,Talens A

    更新日期:1991-01-01 00:00:00

  • Parallel imaging for first-pass myocardial perfusion.

    abstract::Two parallel imaging methods used for first-pass myocardial perfusion imaging were compared in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image artifacts. One used adaptive Time-adaptive SENSitivity Encoding (TSENSE) and the other used GeneRalized Autocalibrating Partially Parallel Acquisi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.10.012

    authors: Irwan R,Lubbers DD,van der Vleuten PA,Kappert P,Götte MJ,Sijens PE

    更新日期:2007-06-01 00:00:00

  • A 32-channel coil system for MR vessel wall imaging of intracranial and extracranial arteries at 3T.

    abstract:PURPOSE:To develop a RF coil system for joint imaging of intracranial and extracranial arterial vessel wall at 3T. MATERIALS AND METHOD:The coil system consists of a 24-channel head coil combined with an 8-channel carotid coil. It is compared with a standard coil configuration (12-channel head coil+4-channel neck coil...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.10.018

    authors: Hu X,Li Y,Zhang L,Zhang X,Liu X,Chung YC

    更新日期:2017-02-01 00:00:00

  • Characterisation of wetting heterogeneities in sandstone rocks by MRI.

    abstract::MRI is applied to the visualisation of wetting heterogeneities evidenced by water proton T1 contrast at 0.1 T. Water saturated Fontainebleau sandstone samples were examined either in their original water-wet condition, or after silanation. T1, T2Hahn, and T2CPMG were measured for several porosities. T1 and T2CPMG of h...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91557-1

    authors: Guillot G,Chardaire-Rivière C,Bobroff S,Le Roux A,Roussel JC,Cuiec L

    更新日期:1994-01-01 00:00:00

  • A non-invasive technique for 3-dimensional assessment of articular cartilage thickness based on MRI. Part 1: Development of a computational method.

    abstract::Articular cartilage thickness is of relevance in various fields in diagnostics and biomedical research. In view of recent improvements of MR cartilage imaging a computational method has been developed for three-dimensional determination of cartilage thickness from tomographic datasets. A correction algorithm that comp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00012-x

    authors: Lösch A,Eckstein F,Haubner M,Englmeier KH

    更新日期:1997-01-01 00:00:00

  • Rapid acquisition strategy for functional T1ρ mapping of the brain.

    abstract::Functional T1ρ mapping has been proposed as a method to assess pH and metabolism dynamics in the brain with high spatial and temporal resolution. The purpose of this work is to describe and evaluate a variant of the spin-locked echo-planar imaging sequence for functional T1ρ mapping at 3T. The proposed sequence rapidl...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.07.010

    authors: Johnson CP,Heo HY,Thedens DR,Wemmie JA,Magnotta VA

    更新日期:2014-11-01 00:00:00

  • In-plane flow velocity quantification along the phase encoding axis in MRI.

    abstract::In-plane flow quantification in MRI offers the potential for assessing vessel patency, and both volume flow rate and flow velocity. These techniques will have definite future impact on MR angiography. The method used in this paper employs motion artifact suppression technique (MAST) gradients to refocus spins travelli...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90409-2

    authors: Duerk JL,Pattany PM

    更新日期:1988-05-01 00:00:00

  • Magnetic resonance imaging at frequencies below 1 kHz.

    abstract::Within the magnetic resonance imaging (MRI) community the trend is going to higher and higher magnetic fields, ranging from 1.5 T to 7 T, corresponding to Larmor frequencies of 63.8-298 MHz. Since for high-field MRI the magnetization increases with the applied magnetic field, the signal-to-noise-ratio increases as wel...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.014

    authors: Hilschenz I,Körber R,Scheer HJ,Fedele T,Albrecht HH,Mario Cassará A,Hartwig S,Trahms L,Haase J,Burghoff M

    更新日期:2013-02-01 00:00:00

  • Effect of vasodilator hydralazine on tumor microvascular random flow and blood volume as measured by intravoxel incoherent motion (IVIM) weighted MRI in conjunction with Gd-DTPA-Albumin enhanced MRI.

    abstract::We studied the effect of hydralazine on tumor blood volume fraction and microvascular random flow velocity magnitude by IVIM weighted MRI in conjunction with dynamic Gd-DTPA-Albumin enhanced MRI. Blood volume fraction maps were obtained from the dynamic Gd-DTPA-Albumin enhanced MRI measurements. The average blood volu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00431-3

    authors: Wang Z,Su MY,Najafi A,Nalcioglu O

    更新日期:2001-10-01 00:00:00

  • An alternative viewpoint of the similarities and differences of SVD and FT deconvolution algorithms used for quantitative MR perfusion studies.

    abstract::Quantitative cerebral blood flow (CBF) values can be determined from residue function estimates obtained from magnetic resonance dynamic susceptibility contrast (DSC) perfusion studies using a variety of deconvolution approaches. However, there are significant differences between the CBF estimates obtained, difference...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.12.001

    authors: Salluzzi M,Frayne R,Smith MR

    更新日期:2005-04-01 00:00:00

  • A volume resolution phantom for MRI.

    abstract::Multisite quantitative magnetic resonance imaging (qMRI) of volume requires a small isotropic point spread-function (PSF) that is spatially, temporarily, and platform invariant. A phantom which will allow rapid assessment of this metric throughout the imaged volume without repositioning will assist certification of im...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.07.002

    authors: Moon SY,Hornak JP

    更新日期:2010-02-01 00:00:00

  • Wavelet-based characterization of vertebral trabecular bone structure from magnetic resonance images at 3 T compared with micro-computed tomographic measurements.

    abstract::Trabecular bone structure and bone density contribute to the strength of bone and are important in the study of osteoporosis. Wavelets are a powerful tool in characterizing and quantifying texture in an image. The purpose of this study was to validate wavelets as a tool in computing trabecular bone thickness directly ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.09.020

    authors: Krug R,Carballido-Gamio J,Burghardt AJ,Haase S,Sedat JW,Moss WC,Majumdar S

    更新日期:2007-04-01 00:00:00

  • Initial changes of non-traumatic osteonecrosis of femoral head in fat suppression images: bone marrow edema was not found before the appearance of band patterns.

    abstract::The present study examined initial changes in non-traumatic osteonecrosis of the femoral head (ONF) on T1- and T2-weighted MR images, and fat suppression images. The subjects were 57 renal transplant recipients (37 males and 20 females), whose median age at the time of transplantation was 31.5 years old (range, 10 to ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00424-6

    authors: Fujioka M,Kubo T,Nakamura F,Shibatani M,Ueshima K,Hamaguchi H,Inoue S,Sugano N,Sakai T,Torii Y,Hasegawa Y,Hirasawa Y

    更新日期:2001-09-01 00:00:00

  • Strategies for reducing large fMRI data sets for independent component analysis.

    abstract::In independent component analysis (ICA), principal component analysis (PCA) is generally used to reduce the raw data to a few principal components (PCs) through eigenvector decomposition (EVD) on the data covariance matrix. Although this works for spatial ICA (sICA) on moderately sized fMRI data, it is intractable for...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.013

    authors: Wang Z,Wang J,Calhoun V,Rao H,Detre JA,Childress AR

    更新日期:2006-06-01 00:00:00