Rapid acquisition strategy for functional T1ρ mapping of the brain.

Abstract:

:Functional T1ρ mapping has been proposed as a method to assess pH and metabolism dynamics in the brain with high spatial and temporal resolution. The purpose of this work is to describe and evaluate a variant of the spin-locked echo-planar imaging sequence for functional T1ρ mapping at 3T. The proposed sequence rapidly acquires a time series of T1ρ maps with 4.0second temporal resolution and 10 slices of volumetric coverage. Simulation, phantom, and in vivo experiments are used to evaluate many aspects of the sequence and its implementation including fidelity of measured T1ρ dynamics, potential confounds to the T1ρ response, imaging parameter tradeoffs, time series analysis approaches, and differences compared to blood oxygen level dependent functional magnetic resonance imaging. It is shown that the high temporal resolution and volumetric coverage of the sequence are obtained with some expense including underestimation of the T1ρ response, sensitivity to T1 dynamics, and reduced signal-to-noise ratio. In vivo studies using a flashing checkerboard functional magnetic resonance imaging paradigm suggest differences between T1ρ and blood oxygen level dependent activation patterns. Possible sources of the functional T1ρ response and potential sequence improvements are discussed. The capability of T1ρ to map whole-brain pH and metabolism dynamics with high temporal and spatial resolution is potentially unique and warrants further investigation and development.

journal_name

Magn Reson Imaging

authors

Johnson CP,Heo HY,Thedens DR,Wemmie JA,Magnotta VA

doi

10.1016/j.mri.2014.07.010

subject

Has Abstract

pub_date

2014-11-01 00:00:00

pages

1067-77

issue

9

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(14)00213-6

journal_volume

32

pub_type

杂志文章
  • A deep learning approach to estimation of subject-level bias and variance in high angular resolution diffusion imaging.

    abstract::The ability to evaluate empirical diffusion MRI acquisitions for quality and to correct the resulting imaging metrics allows for improved inference and increased replicability. Previous work has shown promise for estimation of bias and variance of generalized fractional anisotropy (GFA) but comes at the price of compu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.03.021

    authors: Hainline AE,Nath V,Parvathaneni P,Schilling KG,Blaber JA,Anderson AW,Kang H,Landman BA

    更新日期:2019-06-01 00:00:00

  • Detection of viable myocardium in segments with fixed defects on thallium-201 scintigraphy: usefulness of magnetic resonance imaging early after acute myocardial infarction.

    abstract::To determine if magnetic resonance imaging (MRI) can be used to detect tissue viability in segments with persistent 201T1 defects early following acute myocardial infarction, 24 patients underwent MRI and adenosine 201T1 single photon emission computed tomography (SPECT) imaging at approximately 6 days. Infarction was...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90214-x

    authors: Johnston DL,Gupta VK,Wendt RE,Mahmarian JJ,Verani MS

    更新日期:1993-01-01 00:00:00

  • Pulsed arterial spin labeling perfusion imaging at 3 T: estimating the number of subjects required in common designs of clinical trials.

    abstract::Pulsed arterial spin labeling (PASL) is an increasingly common technique for noninvasively measuring cerebral blood flow (CBF) and has previously been shown to have good repeatability. It is likely to find a place in clinical trials and in particular the investigation of pharmaceutical agents active in the central ner...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.02.030

    authors: Murphy K,Harris AD,Diukova A,Evans CJ,Lythgoe DJ,Zelaya F,Wise RG

    更新日期:2011-12-01 00:00:00

  • Quantitative longitudinal fluid saturation profiles with a slice-selected CPMG sequence.

    abstract::A technique for obtaining quantitative longitudinal saturation/porosity profiles of rock cores which are longer than the NMR coil has been developed. The slice-selected experiment uses a prefocused pulse in conjunction with a magnetic field gradient for the localization and a CPMG sequence to sample the data. A variet...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91547-4

    authors: Pierens GK,Peyron M,Lucas AJ,Carpenter TA,Hall LD,Potter GF,Stewart RC,Phelps DW

    更新日期:1994-01-01 00:00:00

  • Diffusion tensor imaging of native and degenerated human articular cartilage.

    abstract::Diffusion tensor imaging (DTI) is potentially sensitive to collagen degeneration in cartilage. In this study, DTI was measured on human cartilage samples with interventions of trypsin and collagenase. The measured preferred diffusion direction was consistent with the zonal structure of collagen network. The glycosamin...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.10.015

    authors: Deng X,Farley M,Nieminen MT,Gray M,Burstein D

    更新日期:2007-02-01 00:00:00

  • Short T2 contrast with three-dimensional ultrashort echo time imaging.

    abstract::There is increasing interest in imaging short T2 species which show little or no signal with conventional magnetic resonance (MR) pulse sequences. In this paper, we describe the use of three-dimensional ultrashort echo time (3D UTE) sequences with TEs down to 8 μs for imaging of these species. Image contrast was gener...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.11.003

    authors: Du J,Bydder M,Takahashi AM,Carl M,Chung CB,Bydder GM

    更新日期:2011-05-01 00:00:00

  • Strategies for reducing large fMRI data sets for independent component analysis.

    abstract::In independent component analysis (ICA), principal component analysis (PCA) is generally used to reduce the raw data to a few principal components (PCs) through eigenvector decomposition (EVD) on the data covariance matrix. Although this works for spatial ICA (sICA) on moderately sized fMRI data, it is intractable for...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.013

    authors: Wang Z,Wang J,Calhoun V,Rao H,Detre JA,Childress AR

    更新日期:2006-06-01 00:00:00

  • Diagnosis of discoid lateral meniscus of the knee on MR imaging.

    abstract::To establish the quantitative MR diagnostic criteria for discoid lateral meniscus, MR imaging of 60 knees with arthroscopically confirmed discoid lateral menisci and 134 knees with semilunar lateral menisci were analyzed. Following four quantitative parameters were measured. (1) Meniscal width (MW): The minimum menisc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00473-3

    authors: Samoto N,Kozuma M,Tokuhisa T,Kobayashi K

    更新日期:2002-01-01 00:00:00

  • Transdermal water mobility in the presence of electrical fields using MR microscopy.

    abstract::Magnetic resonance microscopy of skin from hairless rats under the influence of electrical fields was conducted for two cases: 1) low voltage constant electrical fields and 2) high-voltage short pulse, electrical fields. Under conditions of the low voltage and low current iontophoresis, i.e., 0 to 20 V, and 0 to 0.5 m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00067-3

    authors: Caban JB,Moerland TS,Gibbs SJ,McFadden L,Locke BR

    更新日期:1999-10-01 00:00:00

  • Wavelet-based characterization of vertebral trabecular bone structure from magnetic resonance images at 3 T compared with micro-computed tomographic measurements.

    abstract::Trabecular bone structure and bone density contribute to the strength of bone and are important in the study of osteoporosis. Wavelets are a powerful tool in characterizing and quantifying texture in an image. The purpose of this study was to validate wavelets as a tool in computing trabecular bone thickness directly ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.09.020

    authors: Krug R,Carballido-Gamio J,Burghardt AJ,Haase S,Sedat JW,Moss WC,Majumdar S

    更新日期:2007-04-01 00:00:00

  • Controlled delivery of Gd-containing liposomes to lymph nodes: surface modification may enhance MRI contrast properties.

    abstract::Surface modification of liposomes containing Gd-diethylenetriaminepentaacetyl-phosphatidylethanolamine (Gd-DTPA-PE) as an amphiphilic paramagnetic label influences their contrast properties as MRI agents. Liposomes with the mean diameter ca. 220 nm and 10% mol content of Gd-DTPA-PE were modified with dextran (molecula...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)00083-f

    authors: Trubetskoy VS,Cannillo JA,Milshtein A,Wolf GL,Torchilin VP

    更新日期:1995-01-01 00:00:00

  • The diagnosis of hippocampal sclerosis: other techniques.

    abstract::Pathologically, hippocampal sclerosis (HS) is characterized by neuronal loss and gliosis affecting particularly the pyramidal neurons of CA1, CA3, and CA4 with relative sparing of the CA2 neurons. This can be identified in vivo with magnetic resonance (MR) imaging techniques that can reveal both morphological and sign...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(95)02016-m

    authors: Jackson GD

    更新日期:1995-01-01 00:00:00

  • Multi-parametric MRI of the physiology and optics of the in-vivo mouse lens.

    abstract::The optics of the ocular lens are determined by its geometry (shape and volume) and its inherent gradient of refractive index (water to protein ratio), which are in turn maintained by unique cellular physiology known as the lens internal microcirculation system. Previously, magnetic resonance imaging (MRI) has been us...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.04.015

    authors: Muir ER,Pan X,Donaldson PJ,Vaghefi E,Jiang Z,Sellitto C,White TW

    更新日期:2020-07-01 00:00:00

  • Assessment of the anomalous pulmonary circulation by dynamic contrast-enhanced MR angiography in under four seconds.

    abstract::The purpose of this study was to demonstrate the initial results of the dynamic contrast-enhanced MRA in under four seconds in the assessment of anomalous pulmonary circulation. We performed dynamic contrast enhanced MRA on ten patients with a temporal resolution of 2-3 sec for each phase. Five patients had pulmonary ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00634-3

    authors: Balci NC,Yalçin Y,Tunaci A,Balci Y

    更新日期:2003-01-01 00:00:00

  • The precision of DCE-MRI using the tissue homogeneity model with continuous formulation of the perfusion parameters.

    abstract::The present trend in dynamic contrast-enhanced MRI is to increase the number of estimated perfusion parameters using complex pharmacokinetic models. However, less attention is given to the precision analysis of the parameter estimates. In this paper, the distributed capillary adiabatic tissue homogeneity pharmacokinet...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.02.003

    authors: Bartoš M,Jiřík R,Kratochvíla J,Standara M,Starčuk Z Jr,Taxt T

    更新日期:2014-06-01 00:00:00

  • Study of lipid metabolism by estimating the fat fraction in different breast tissues and in various breast tumor sub-types by in vivo 1H MR spectroscopy.

    abstract:PURPOSE:To evaluate the utility of fat fraction (FF) for the differentiation of different breast tissues and in various breast tumor subtypes using in vivo proton (1H) magnetic resonance spectroscopy (MRS). METHODS:1H MRS was performed on 68 malignant, 35 benign, and 30 healthy volunteers at 1.5 T. Malignant breast ti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.02.004

    authors: Agarwal K,Sharma U,Mathur S,Seenu V,Parshad R,Jagannathan NR

    更新日期:2018-06-01 00:00:00

  • Manifestation and post hoc correction of gradient cross-term artifacts in DTI.

    abstract::Cross-terms between imaging and diffusion gradients, unaccounted for during tensor calculations, can lead to erroneous estimation of diffusivity and fractional anisotropy (FA) in regions of isotropic and anisotropic diffusion. Cross-term of magnitude 136.8±1.6 s/mm(2), artificially introduced in the slice-encode direc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.02.021

    authors: Nair G,Hu XP

    更新日期:2012-07-01 00:00:00

  • Phase gradient imaging for positive contrast generation to superparamagnetic iron oxide nanoparticle-labeled targets in magnetic resonance imaging.

    abstract::Positive contrast imaging methods produce enhanced signal at large magnetic field gradient in magnetic resonance imaging. Several postprocessing algorithms, such as susceptibility gradient mapping and phase gradient mapping methods, have been applied for positive contrast generation to detect the cells targeted by sup...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.04.011

    authors: Zhu H,Demachi K,Sekino M

    更新日期:2011-09-01 00:00:00

  • Anisotropic diffusion in etched particle tracks studied by field gradient NMR.

    abstract::Etched particle tracks produced after heavy ion irradiation of polymer foils are used as model systems to test the performance of NMR in a newly developed ultrahigh magnetic field gradient system. The stimulated NMR echo decay of molecules diffusing in the channels, formulated in terms of the self part of the intermed...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91527-x

    authors: Fujara F,Ilyina E,Nienstaedt H,Sillescu H,Spohr R,Trautmann C

    更新日期:1994-01-01 00:00:00

  • A proposal for a semiquantitative scoring system for lymphedema using Non-contrast Magnetic Resonance Lymphography (NMRL): Reproducibility among readers and correlation with clinical grading.

    abstract:PURPOSE:To assess the ability and reproducibility of Non-contrast Magnetic Resonance Lymphography (NMRL) in detecting and quantify lymphedema, using a semiquantitative scoring system. METHODS AND MATERIAL:This is a monocentric retrospective study of 134 consecutive patients with a clinical diagnosis of limb lymphedema...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.02.004

    authors: Franconeri A,Ballati F,Panzuto F,Raciti MV,Smedile A,Maggi A,Asteggiano C,Esposito M,Stoppa D,Lungarotti L,Bortolotto C,Giardini D,De Silvestri A,Calliada F

    更新日期:2020-05-01 00:00:00

  • Chemical exchange saturation transfer MR imaging of articular cartilage glycosaminoglycans at 3 T: Accuracy of B0 Field Inhomogeneity corrections with gradient echo method.

    abstract::Glycosaminoglycan Chemical Exchange Saturation Transfer (gagCEST) is an important molecular MRI methodology developed to assess changes in cartilage GAG concentrations. The correction for B0 field inhomogeneity is technically crucial in gagCEST imaging. This study evaluates the accuracy of the B0 estimation determined...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.07.009

    authors: Wei W,Jia G,Flanigan D,Zhou J,Knopp MV

    更新日期:2014-01-01 00:00:00

  • Fast acceleration of ASL-based time-resolved magnetic resonance angiography by acquisition of control and labeled images in the same shot (fast ACTRESS): An optimization study.

    abstract:PURPOSE:To establish an optimized sequence design for fast acceleration of arterial spin labeling (ASL)-based time-resolved magnetic resonance angiography (MRA) by acquisition of control and labeled images in the same shot (fast ACTRESS) and a scan time of <1min, for the evaluation of intracranial vessels. MATERIALS A...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.07.026

    authors: Sugimori H,Fujima N,Suzuki Y,Hamaguchi H,Ishizaka K,Kudo K

    更新日期:2017-11-01 00:00:00

  • esfMRI of the upper STS: further evidence for the lack of electrically induced polysynaptic propagation of activity in the neocortex.

    abstract::Combining electrical stimulation with fMRI (esfMRI) has proven to be an important tool to study the global effects of electrical stimulation on neural networks in the brain. Here we extend our previous studies to stimulating the upper superior temporal sulcus (STS) in the anesthetized monkey. Our results show that sti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.04.005

    authors: Sultan F,Augath M,Murayama Y,Tolias AS,Logothetis N

    更新日期:2011-12-01 00:00:00

  • Arterial input functions (AIFs) measured directly from arteries with low and standard doses of contrast agent, and AIFs derived from reference tissues.

    abstract::Measurements of arterial input function (AIF) can have large systematic errors at standard contrast agent doses in dynamic contrast enhanced MRI (DCE-MRI). We compared measured AIFs from low dose (AIFLD) and standard dose (AIFSD) contrast agent injections, as well as the AIF derived from a muscle reference tissue and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.10.025

    authors: Wang S,Fan X,Medved M,Pineda FD,Yousuf A,Oto A,Karczmar GS

    更新日期:2016-02-01 00:00:00

  • Comparison of different methods for combining phase-contrast images obtained with multiple coils.

    abstract::The ability to determine coil sensitivities implies that a method optimized in terms of maximized signal-to-noise ratio (SNR) can be applied to the combination of multiple coil images. An optimization of SNR subsequently results in a minimized variance in quantitative velocity measurements using phase-contrast imaging...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.06.002

    authors: Thunberg P,Karlsson M,Wigström L

    更新日期:2005-09-01 00:00:00

  • Gd-EOB-DTPA-enhanced-MR imaging in the inflammation stage of nonalcoholic steatohepatitis (NASH) in mice.

    abstract:OBJECTIVE:The purpose of this study is to investigate the correlation between the liver kinetics of gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA) and liver histopathology in a mouse model of NASH by using dynamic contrast-enhanced MRI. MATERIALS AND METHODS:Twenty male C57/BL6 mice aged 8we...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.03.009

    authors: Yamada T,Obata A,Kashiwagi Y,Rokugawa T,Matsushima S,Hamada T,Watabe H,Abe K

    更新日期:2016-07-01 00:00:00

  • Effect of vasodilator hydralazine on tumor microvascular random flow and blood volume as measured by intravoxel incoherent motion (IVIM) weighted MRI in conjunction with Gd-DTPA-Albumin enhanced MRI.

    abstract::We studied the effect of hydralazine on tumor blood volume fraction and microvascular random flow velocity magnitude by IVIM weighted MRI in conjunction with dynamic Gd-DTPA-Albumin enhanced MRI. Blood volume fraction maps were obtained from the dynamic Gd-DTPA-Albumin enhanced MRI measurements. The average blood volu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00431-3

    authors: Wang Z,Su MY,Najafi A,Nalcioglu O

    更新日期:2001-10-01 00:00:00

  • Effect of physiological heart rate variability on quantitative T2 measurement with ECG-gated Fast Spin Echo (FSE) sequence and its retrospective correction.

    abstract:OBJECT:Quantitative T2 measurement is applied in cardiac Magnetic Resonance Imaging (MRI) for the diagnosis and follow-up of myocardial pathologies. Standard Electrocardiogram (ECG)-gated fast spin echo pulse sequences can be used clinically for T2 assessment, with multiple breath-holds. However, heart rate is subject ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.06.006

    authors: de Roquefeuil M,Vuissoz PA,Escanyé JM,Felblinger J

    更新日期:2013-11-01 00:00:00

  • The uptake of Mn-DPDP by hepatocytes is not mediated by the facilitated transport of pyridoxine.

    abstract::Manganese-dipyridoxal diphosphate (Mn-DPDP) is a liver-selective contrast agent selectively taken up by the hepatocytes. Because of the analogy of structure with pyridoxine (vitamin B6), it was previously suggested that this compound can be selectively taken up by the facilitated transport of vitamers B6. To understan...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00140-3

    authors: Gallez B,Baudelet C,Adline J,Charbon V,Lambert DM

    更新日期:1996-01-01 00:00:00

  • Structural changes in glutamate cell swelling followed by multiparametric q-space diffusion MR of excised rat spinal cord.

    abstract::Diffusion in the extracellular and intracellular spaces (ECS and ICS, respectively) was evaluated in excised spinal cords, before and after cell swelling induced by glutamate, by high b-value q-space diffusion MR of specific markers and water. The signal decays of deuterated tetramethylammonium (TMA-d(12)) chloride, a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.029

    authors: Biton IE,Mayk A,Assaf Y,Cohen Y

    更新日期:2004-06-01 00:00:00