Effect of vasodilator hydralazine on tumor microvascular random flow and blood volume as measured by intravoxel incoherent motion (IVIM) weighted MRI in conjunction with Gd-DTPA-Albumin enhanced MRI.

Abstract:

:We studied the effect of hydralazine on tumor blood volume fraction and microvascular random flow velocity magnitude by IVIM weighted MRI in conjunction with dynamic Gd-DTPA-Albumin enhanced MRI. Blood volume fraction maps were obtained from the dynamic Gd-DTPA-Albumin enhanced MRI measurements. The average blood volume fraction of R3230 AC adenocarcinoma decreased from 0.125 +/- 0.022 (s.d.) ml/g to 0.105 +/- 0.018 (s.d.) ml/g (p < 0.001) after the administration of hydralazine at a dose of 5 mg/kg. The microvascular random flow velocity magnitude maps were obtained from the IVIM weighted MRI signals by utilizing the Gd-DTPA-Albumin measured blood volume fractions as an input in the compartmental modeling analysis of the IVIM weighted MRI signal. The random-directional microvascular flow induced MRI signal attenuation was separated from the molecular diffusion induced signal attenuation. Flow induced attenuation was more significant after the administration of hydralazine. The mean microvascular random flow velocity magnitude increased from 0.52 +/- 0.15 (s.d.) mm/sec to 0.73 +/- 0.23 (s.d.) mm/sec (p < 0.05) in the presence of the above blood volume fraction change.

journal_name

Magn Reson Imaging

authors

Wang Z,Su MY,Najafi A,Nalcioglu O

doi

10.1016/s0730-725x(01)00431-3

subject

Has Abstract

pub_date

2001-10-01 00:00:00

pages

1063-72

issue

8

eissn

0730-725X

issn

1873-5894

pii

S0730725X01004313

journal_volume

19

pub_type

杂志文章
  • Non-contrast enhanced 3D SSFP MRA of the renal allograft vasculature: a comparison between radial linear combination and Cartesian inflow-weighted acquisitions.

    abstract::Renal transplant patients often require imaging to ensure appropriate graft placement, to assess integrity of transplant vessel anastomosis and to evaluate for stenosis that can be a cause of graft failure. Because there is risk for nephrogenic systemic fibrosis in the setting of renal insufficiency, the use of non-co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.10.004

    authors: Bultman EM,Klaers J,Johnson KM,François CJ,Schiebler ML,Reeder SB,Block WF

    更新日期:2014-02-01 00:00:00

  • MRI of the normal hippocampus.

    abstract::Before it is possible to use MR imaging to investigate changes in the hippocampus in disease processes such as epilepsy and memory disorders, it is imperative that normal variations are defined. Using specific anatomic locations, we evaluated the hippocampi of 29 normal volunteers with coronal MR studies. Mild variati...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90035-k

    authors: Bronen RA,Cheung G

    更新日期:1991-01-01 00:00:00

  • Event-related fMRI of auditory and visual oddball tasks.

    abstract::Functional magnetic resonance imaging (fMRI) was used to investigate the spatial distribution of cortical activation in frontal and parietal lobes during auditory and visual oddball tasks in 10 healthy subjects. The purpose of the study was to compare activation within auditory and visual modalities and identify commo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00128-4

    authors: Stevens AA,Skudlarski P,Gatenby JC,Gore JC

    更新日期:2000-06-01 00:00:00

  • Comparison of BLADE and conventional T2-TSE sequences for the sagittal visualization of the cervical spinal cord in multiple sclerosis patients - a case report.

    abstract::The purpose of this study is to report the significant differences found in the identification of lesions in cervical spinal cord of two patients with multiple sclerosis when using the BLADE T2-TSE and BLADE T2-TIRM sequences as opposed to the conventional T2-TSE and T2-TIRM sequences for sagittal acquisition at 1.5T....

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.07.008

    authors: Lavdas E,Mavroidis P,Topaltzikis T,Slatinopoulos V,Roka V,Vlachopoulou A,Papanikolaou N,Stathakis S,Kapsalaki E,Batsikas G

    更新日期:2013-12-01 00:00:00

  • Tracing neural circuits in vivo with Mn-enhanced MRI.

    abstract::The application of MRI-visible paramagnetic tracers to reveal in vivo connectivity can provide important subject-specific information for multisite, multielectrode intracortical recordings in combined behavioral and physiology experiments. To establish the use of such tracers in the nonhuman primate, we recently compa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.031

    authors: Murayama Y,Weber B,Saleem KS,Augath M,Logothetis NK

    更新日期:2006-05-01 00:00:00

  • Removal of extracerebral tissues in dual-echo magnetic resonance images via linear scale-space features.

    abstract::The location and masking of the brain and surrounding cerebrospinal fluid (CSF) in two-dimensional (2D) dual-echo fast spin-echo (FSE) magnetic resonance (MR) images of the head is achieved by an automated procedure with a voxel-based computational algorithm. Linear scale-space features are derived from the short-echo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00099-x

    authors: Suckling J,Brammer MJ,Lingford-Hughes A,Bullmore ET

    更新日期:1999-02-01 00:00:00

  • Relationship between cancellous bone induced magnetic field and ultrastructure in a rat ovariectomy model.

    abstract::The site-dependent variations in trabecular bone morphology were studied in the rat tibia by magnitude and phase difference three-dimensional nuclear magnetic resonance microscopy and image processing, and the implications of ovariectomy were evaluated. Specimens excised from the proximal tibial metaphysis in ovariect...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00107-1

    authors: Takahashi M,Wehrli FW,Hwang SN,Wehrli SL

    更新日期:2000-01-01 00:00:00

  • A novel in silico platform for a fully automatic personalized brain tumor growth.

    abstract::Glioblastoma Multiforme is the most common and most aggressive type of brain tumors. Although accurate prediction of Glioblastoma borders and shape is absolutely essential for neurosurgeons, there are not many in silico platforms that can make such predictions. In the current study, an automatic patient-specific simul...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.12.012

    authors: Hajishamsaei M,Pishevar A,Bavi O,Soltani M

    更新日期:2020-05-01 00:00:00

  • Semi-adiabatic Shinnar-Le Roux pulses and their application to diffusion tensor imaging of humans at 7T.

    abstract::The adiabatic Shinnar-Le Roux (SLR) algorithm for radiofrequency (RF) pulse design enables systematic control of pulse parameters such as bandwidth, RF energy distribution and duration. Some applications, such as diffusion-weighted imaging (DWI) at high magnetic fields, would benefit from RF pulses that can provide gr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.04.003

    authors: Balchandani P,Qiu D

    更新日期:2014-09-01 00:00:00

  • Dixon-based fat-free MR-angiography compared to first pass and steady-state high-resolution MR-angiography using a blood pool contrast agent.

    abstract:INTRODUCTION:Compared to standard arterial-only first-pass MR-angiography (FPMRA), imaging during the equilibrium phase of a blood pool contrast agent (steady state) has been shown to provide higher image quality and better stenosis grading. Homogenous Dixon fat-suppression promises to increase contrast by suppression ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.07.005

    authors: Homsi R,Gieseke J,Kukuk GM,Träber F,Willinek WA,Schild HH,Hadizadeh DR

    更新日期:2015-11-01 00:00:00

  • Relationship between neural and hemodynamic signals during spontaneous activity studied with temporal kernel CCA.

    abstract::Functional magnetic resonance imaging (fMRI) based on the so-called blood oxygen level-dependent (BOLD) contrast is a powerful tool for studying brain function not only locally but also on the large scale. Most studies assume a simple relationship between neural and BOLD activity, in spite of the fact that it is impor...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.12.016

    authors: Murayama Y,Biessmann F,Meinecke FC,Müller KR,Augath M,Oeltermann A,Logothetis NK

    更新日期:2010-10-01 00:00:00

  • Validation of estimated 3D temperature maps during hepatic cryo surgery.

    abstract::A simple model for estimating temperature distribution within the frozen region during cryo ablation was tested for accuracy. Freezing experiments were conducted in both ex vivo and in vivo porcine livers. Temperature was measured during freezing using a fiber-optic temperature sensor. Three-dimensional MR images were...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00389-7

    authors: Samset E,Mala T,Edwin B,Gladhaug I,Søreide O,Fosse E

    更新日期:2001-06-01 00:00:00

  • 23Na magnetic resonance imaging: distribution of brine in muscle.

    abstract::Magnetic resonance imaging (MRI) has been used to characterize tissues in morphological studies. Here, 23Na NMR imaging was used to study the distribution in muscle of brine (5 M NaCl), injected before onset of rigor mortis. First, the distribution of brine was monitored in excised muscle from rabbits for 6 hr followi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92360-4

    authors: Renou JP,Benderbous S,Bielicki G,Foucat L,Donnat JP

    更新日期:1994-01-01 00:00:00

  • Study on the variations of the apparent diffusion coefficient in areas of solid tumor in high grade gliomas.

    abstract::Present knowledge suggests that in glioblastoma multiforme the value of the apparent diffusion coefficient (ADC) is elevated in the solid part and hyperintense in T1, in spite of the elevated cellularity, and also in areas where peritumoral vasogenic edema is present. The purpose of our study has been to verify in viv...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00594-5

    authors: Muti M,Aprile I,Principi M,Italiani M,Guiducci A,Giulianelli G,Ottaviano P

    更新日期:2002-11-01 00:00:00

  • Utility of magnetization prepared GRE MRI for the detection of focal liver lesions.

    abstract::We compared the efficacy of rapidly acquired magnetization prepared gradient-echo (MP-GRE) sequences with CT and standard MRI pulse sequences for the detection of focal liver lesions. Fourteen patients with 28 focal liver lesions were scanned. TI times of 300, 450, and 600 ms were used. MP-GRE lesion conspicuity was c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92198-9

    authors: Winter TC 3rd,Freeny PC,Nghiem HV,Thomas CR Jr

    更新日期:1994-01-01 00:00:00

  • A simple method for MR elastography: a gradient-echo type multi-echo sequence.

    abstract::To demonstrate the feasibility of a novel MR elastography (MRE) technique based on a conventional gradient-echo type multi-echo MR sequence which does not need additional bipolar magnetic field gradients (motion encoding gradient: MEG), yet is sensitive to vibration. In a gradient-echo type multi-echo MR sequence, sev...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.10.002

    authors: Numano T,Mizuhara K,Hata J,Washio T,Homma K

    更新日期:2015-01-01 00:00:00

  • Development and validation of a novel large field of view phantom and a software module for the quality assurance of geometric distortion in magnetic resonance imaging.

    abstract:OBJECTIVE:To develop and validate a large field of view phantom and quality assurance software tool for the assessment and characterization of geometric distortion in MRI scanners commissioned for radiation therapy planning. MATERIALS AND METHODS:A purpose built phantom was developed consisting of 357 rods (6mm in dia...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2015.04.003

    authors: Torfeh T,Hammoud R,McGarry M,Al-Hammadi N,Perkins G

    更新日期:2015-09-01 00:00:00

  • Quantitative determination of porosity: a local assessment by NMR imaging techniques.

    abstract::The local determination of porosity is an extremely valuable target because of different applications in petrophysics. In fact, obtaining a reliable profile of porosity or saturations could considerably improve the evaluation of transport properties of porous media, especially if applied to multiphase flow test (i.e.,...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00182-8

    authors: Borgia GC,Bortolotti V,Dattilo P,Fantazzini P,Maddinelli G

    更新日期:1996-01-01 00:00:00

  • The uptake of Mn-DPDP by hepatocytes is not mediated by the facilitated transport of pyridoxine.

    abstract::Manganese-dipyridoxal diphosphate (Mn-DPDP) is a liver-selective contrast agent selectively taken up by the hepatocytes. Because of the analogy of structure with pyridoxine (vitamin B6), it was previously suggested that this compound can be selectively taken up by the facilitated transport of vitamers B6. To understan...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00140-3

    authors: Gallez B,Baudelet C,Adline J,Charbon V,Lambert DM

    更新日期:1996-01-01 00:00:00

  • Magnetic resonance imaging at frequencies below 1 kHz.

    abstract::Within the magnetic resonance imaging (MRI) community the trend is going to higher and higher magnetic fields, ranging from 1.5 T to 7 T, corresponding to Larmor frequencies of 63.8-298 MHz. Since for high-field MRI the magnetization increases with the applied magnetic field, the signal-to-noise-ratio increases as wel...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.014

    authors: Hilschenz I,Körber R,Scheer HJ,Fedele T,Albrecht HH,Mario Cassará A,Hartwig S,Trahms L,Haase J,Burghoff M

    更新日期:2013-02-01 00:00:00

  • Neuroprotective effect of agmatine in rats with transient cerebral ischemia using MR imaging and histopathologic evaluation.

    abstract:PURPOSE:This study aimed to further investigate the effects of agmatine on brain edema in the rats with middle cerebral artery occlusion (MCAO) injury using magnetic resonance imaging (MRI) monitoring and biochemical and histopathologic evaluation. MATERIALS AND METHODS:Following surgical induction of MCAO for 90min, ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.03.026

    authors: Huang YC,Tzeng WS,Wang CC,Cheng BC,Chang YK,Chen HH,Lin PC,Huang TY,Chuang TJ,Lin JW,Chang CP

    更新日期:2013-09-01 00:00:00

  • Echo-shifted multislice EPI for high-speed fMRI.

    abstract::The advantages of event-related functional Magnetic Resonance Imaging (fMRI) and the increasing use of fMRI in cognitive experiments are both driving the development of techniques that allow images sensitive to the blood oxygen level-dependent effect to be acquired at ever-higher temporal resolution. Here, we present ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.030

    authors: Gibson A,Peters AM,Bowtell R

    更新日期:2006-05-01 00:00:00

  • Magnetization transfer of water T(2) relaxation components in human brain: implications for T(2)-based segmentation of spectroscopic volumes.

    abstract::Biexponential T(2) relaxation of the localized water signal can be used for segmentation of spectroscopic volumes. To assess the specificity of the components an iterative relaxation measurement of the localized water signal (STEAM, 12 echo times, geometric spacing from 30 ms to 2000 ms) was combined with magnetizatio...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00396-4

    authors: Helms G,Piringer A

    更新日期:2001-07-01 00:00:00

  • Diffusional kurtosis imaging of cingulate fibers in Parkinson disease: comparison with conventional diffusion tensor imaging.

    abstract:OBJECTIVE:The pathological changes in Parkinson disease begin in the brainstem; reach the limbic system and ultimately spread to the cerebral cortex. In Parkinson disease (PD) patients, we evaluated the alteration of cingulate fibers, which comprise part of the limbic system, by using diffusional kurtosis imaging (DKI)...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.06.009

    authors: Kamagata K,Tomiyama H,Motoi Y,Kano M,Abe O,Ito K,Shimoji K,Suzuki M,Hori M,Nakanishi A,Kuwatsuru R,Sasai K,Aoki S,Hattori N

    更新日期:2013-11-01 00:00:00

  • esfMRI of the upper STS: further evidence for the lack of electrically induced polysynaptic propagation of activity in the neocortex.

    abstract::Combining electrical stimulation with fMRI (esfMRI) has proven to be an important tool to study the global effects of electrical stimulation on neural networks in the brain. Here we extend our previous studies to stimulating the upper superior temporal sulcus (STS) in the anesthetized monkey. Our results show that sti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.04.005

    authors: Sultan F,Augath M,Murayama Y,Tolias AS,Logothetis N

    更新日期:2011-12-01 00:00:00

  • Magic angle effect in magnetic resonance imaging of the Achilles tendon and enthesis.

    abstract::Collagen fibers in tendons and entheses are highly ordered. The protons within the bound water are subject to dipolar interactions whose strength depends on the orientation of the fibers to the static magnetic field B(0). Clinical pulse sequences have been employed to investigate this magic angle effect of the Achille...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.09.003

    authors: Du J,Pak BC,Znamirowski R,Statum S,Takahashi A,Chung CB,Bydder GM

    更新日期:2009-05-01 00:00:00

  • MRI-assisted radiation therapy planning of brain tumors--clinical experiences in 17 patients.

    abstract::A new and simple method for precise determination of lateral opposed treatment portals was developed and used in 17 patients. Compared to CT, MRI led to significant changes of portals in 59% (10/17) of cases. Individual shielding blocks could be precisely designed by use of our new method. MRI is the procedure of choi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90007-9

    authors: Just M,Rösler HP,Higer HP,Kutzner J,Thelen M

    更新日期:1991-01-01 00:00:00

  • Quantitative 1H MRS in the evaluation of mesial temporal lobe epilepsy in vivo.

    abstract::Hippocampal metabolite concentrations were determined by localized in vivo proton magnetic resonance spectroscopy (1H MRS) in eleven patients suffering from refractory mesial temporal lobe epilepsy (MTLE), as well as in eleven age-matched healthy volunteers, and compared with patient history, postoperative outcome and...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00123-4

    authors: Duc CO,Trabesinger AH,Weber OM,Meier D,Walder M,Wieser HG,Boesiger P

    更新日期:1998-10-01 00:00:00

  • Dependence of temporal diffusion spectra on microstructural properties of biological tissues.

    abstract::The apparent diffusion coefficient (ADC) measured using magnetic resonance imaging methods provides information on microstructural properties of biological tissues, and thus has found applications as a useful biomarker for assessing changes such as those that occur in ischemic stroke and cancer. Conventional pulsed gr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.10.002

    authors: Xu J,Does MD,Gore JC

    更新日期:2011-04-01 00:00:00

  • Automated measurement of fat infiltration in the hip abductors from Dixon magnetic resonance imaging.

    abstract:PURPOSE:Intramuscular fat infiltration is a dynamic process, in response to exercise and muscle health, which can be quantified by estimating fat fraction (FF) from Dixon MRI. Healthy hip abductor muscles are a good indicator of a healthy hip and an active lifestyle as they have a fundamental role in walking. The autom...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.06.019

    authors: Belzunce MA,Henckel J,Fotiadou A,Di Laura A,Hart A

    更新日期:2020-10-01 00:00:00