Wavelet-based characterization of vertebral trabecular bone structure from magnetic resonance images at 3 T compared with micro-computed tomographic measurements.

Abstract:

:Trabecular bone structure and bone density contribute to the strength of bone and are important in the study of osteoporosis. Wavelets are a powerful tool in characterizing and quantifying texture in an image. The purpose of this study was to validate wavelets as a tool in computing trabecular bone thickness directly from gray-level images. To this end, eight cylindrical cores of vertebral trabecular bone were imaged using 3-T magnetic resonance imaging (MRI) and micro-computed tomography (microCT). Thickness measurements of the trabecular bone from the wavelet-based analysis were compared with standard 2D structural parameters analogous to bone histomorphometry (MR images) and direct 3D distance transformation methods (microCT images). Additionally, bone volume fraction was determined using each method. The average difference in trabecular thickness between the wavelet and standard methods was less than the size of 1 pixel size for both MRI and microCT analysis. A correlation (R) of .94 for microCT measurements and that of .52 for MRI were found for the bone volume fraction. Based on these results, we conclude that wavelet-based methods deliver results comparable with those from established MR histomorphometric measurements. Because the wavelet transform is more robust with respect to image noise and operates directly on gray-level images, it could be a powerful tool for computing structural bone parameters from MR images acquired using high resolution and thus limited signal scenarios.

journal_name

Magn Reson Imaging

authors

Krug R,Carballido-Gamio J,Burghardt AJ,Haase S,Sedat JW,Moss WC,Majumdar S

doi

10.1016/j.mri.2006.09.020

subject

Has Abstract

pub_date

2007-04-01 00:00:00

pages

392-8

issue

3

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(06)00298-0

journal_volume

25

pub_type

杂志文章
  • Test-retest reliability of cerebral blood flow in healthy individuals using arterial spin labeling: Findings from the EMBARC study.

    abstract:INTRODUCTION:Previous investigations of test-retest reliability of cerebral blood flow (CBF) at rest measured with pseudo-continuous Arterial Spin Labeling (pCASL) demonstrated good reliability, but are limited by the use of similar scanner platforms. In the present study we examined test-retest reliability of CBF in r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.09.004

    authors: Almeida JRC,Greenberg T,Lu H,Chase HW,Fournier JC,Cooper CM,Deckersbach T,Adams P,Carmody T,Fava M,Kurian B,McGrath PJ,McInnis MG,Oquendo MA,Parsey R,Weissman M,Trivedi M,Phillips ML

    更新日期:2018-01-01 00:00:00

  • Initial clinical evaluation of gadolinium DTPA for contrast-enhanced magnetic resonance imaging.

    abstract::Gadolinium DTPA was evaluated as an intravenous contrast agent for magnetic resonance imaging in 15 patients with primary or secondary intracranial neoplastic disease. T1 and T2 weighted images were obtained prior to contrast administration. T1 weighted spin echo 35/800 (TE/TR) images were utilized to detect enhanceme...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(85)90006-2

    authors: Runge VM,Schoerner W,Niendorf HP,Laniado M,Koehler D,Claussen C,Felix R,James AE Jr

    更新日期:1985-01-01 00:00:00

  • MR imaging of cervical spine motion with HASTE.

    abstract::The HASTE (half-Fourier acquisition single-shot turbo spin-echo) technique delivers images with T2-weighting in about half a second and could be ideal for fast dynamic studies when T2-weighting is needed. We evaluated cardiac-triggered HASTE to study cervical spine flexion/extension. The cervical spines of ten asympto...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00176-3

    authors: Duerinckx AJ,Yu WD,El-Saden S,Kim D,Wang JC,Sandhu HS

    更新日期:1999-04-01 00:00:00

  • Characteristics of geometric distortion correction with increasing field-of-view in open-configuration MRI.

    abstract::Open-configuration magnetic resonance imaging (MRI) systems are becoming increasingly desirable for musculoskeletal imaging and image-guided radiotherapy because of their non-claustrophobic configuration. However, geometric image distortion in large fields-of-view (FOV) due to field inhomogeneity and gradient nonlinea...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.02.007

    authors: Hong C,Lee DH,Han BS

    更新日期:2014-07-01 00:00:00

  • Accurate and sensitive measurements of magnetic susceptibility using echo planar imaging.

    abstract::Susceptibility differences are common causes for artifacts in magnetic resonance (MR); therefore, it is important to choose phantom materials in a way that these artifacts are kept at a minimum. In this study, a previously proposed MR imaging (MRI) method [Beuf O, Briguet A, Lissac M, Davis R. Magnetic resonance imagi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.07.005

    authors: Carlsson A,Starck G,Ljungberg M,Ekholm S,Forssell-Aronsson E

    更新日期:2006-11-01 00:00:00

  • Signal and contrast effects due to T2 decay during k-space readout of UTE (ultrashort TE) sequences.

    abstract::In ultrashort TE (UTE) imaging, the short T2 values of the tissues of interest are comparable to the k-space readout duration, which result in significant T2 decay during k-space readout. This decay consequently causes significant effects on signal and contrast in UTE sequences, which we evaluate in this paper using m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.11.002

    authors: Chiang JT,Carl M,Du J

    更新日期:2014-04-01 00:00:00

  • Hair product artifact in magnetic resonance imaging.

    abstract::The presence of metallic compounds in facial cosmetics and permanent tattoos may affect the quality of magnetic resonance imaging. We report a case study describing a signal artifact due to the use of a leave-on powdered hair dye. On reviewing the ingredients of the product, it was found to contain several metallic co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.08.023

    authors: Chenji S,Wilman AH,Mah D,Seres P,Genge A,Kalra S

    更新日期:2017-01-01 00:00:00

  • High-energy phosphate metabolism during incremental calf exercise in humans measured by 31 phosphorus magnetic resonance spectroscopy (31P MRS).

    abstract::Several previous 31 phosphorus magnetic resonance spectroscopy ((31)P MRS) studies performing incremental or progressive muscle exercises have observed that a decrease in pH is accompanied with an acceleration in phosphocreatine (PCr) hydrolysis. The purpose of this study was to investigate the relationship between PC...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.07.001

    authors: Schocke MF,Esterhammer R,Kammerlander C,Rass A,Kremser C,Fraedrich G,Jaschke WR,Greiner A

    更新日期:2004-01-01 00:00:00

  • Quantitation of normal canine hippocampus formation volume: correlation of MRI with gross histology.

    abstract::The hippocampal formation possesses an important role in the development and maintenance of short-term memory. In this study, magnetic resonance imaging (MRI) and gross histology were used to quantify the volume of the hippocampal formation in canines. High resolution MRI, using 1 mm thick slices and an intraplanar re...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02083-6

    authors: Vullo T,Deo-Narine V,Stallmeyer MJ,Gomez DG,Cahill PT

    更新日期:1996-01-01 00:00:00

  • MRI studies of the neurotoxic effects of L-2-chloropropionic acid on rat brain.

    abstract::L-2-Chloropropionic acid (L-CPA) is selectively toxic to rat cerebellar granule cells; necrosis is first observed about 36 hours after administration of L-CPA (750 mg/kg p.o.) becoming more marked by 48 h. Parallel to the onset of cell death an increase in cerebellar water content and sodium concentration has been rep...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00231-4

    authors: Williams RE,Prior M,Bachelard HS,Waterton JC,Checkley D,Lock EA

    更新日期:2001-02-01 00:00:00

  • A flexible 9-channel coil array for fast 3D MR thermometry in MR-guided high-intensity focused ultrasound (HIFU) studies on rabbits at 3 T.

    abstract::Signal-to-noise ratio (SNR) is a critical factor in MR-guided high-intensity focused ultrasound (HIFU) for local heating, which can affect the accuracy of temperature measurement. In order to achieve high SNR and higher temporal resolution, dedicated coil arrays for MR-guided HIFU applications need to be developed. In...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.10.008

    authors: Chen Q,Li Y,Jiang R,Zou C,Tie C,Wen J,Yang X,Zhang X,Liu X,Zheng H

    更新日期:2020-01-01 00:00:00

  • Superparamagnetic iron oxide particles and positive enhancement for myocardial perfusion studies assessed by subsecond T1-weighted MRI.

    abstract::Superparamagnetic iron oxide particles (SPIOs) are usually referred to as T2 MR contrast agents, reducing signal intensity (SI) on T2-weighted MR images (negative enhancement). This study reports the original use of SPIOs as T1-enhancing contrast agents, primarily assessed in vitro, and then applied to an in vivo inve...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90241-5

    authors: Canet E,Revel D,Forrat R,Baldy-Porcher C,de Lorgeril M,Sebbag L,Vallee JP,Didier D,Amiel M

    更新日期:1993-01-01 00:00:00

  • Contrast-enhanced 3D MR voiding urethrography: preliminary results.

    abstract::Contrast-enhanced 3D MR voiding urethrography (CE 3D MRVU) was performed on 5 healthy volunteers and 18 patients with urethral disease. After intravenous injection of 0.3 ml/kg gadolinium, the images of the three consecutive acquisitions of the 3D MRVU technique were obtained during voiding. The raw data were reconstr...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.mri.2004.09.008

    authors: Yekeler E,Suleyman E,Tunaci A,Tunaci M,Balci NC,Onem K,Tunc M,Acunas G

    更新日期:2004-11-01 00:00:00

  • Dual-acquisition phase-sensitive fat-water separation using balanced steady-state free precession.

    abstract::Balanced steady-state free precession (SSFP) sequences use fully re-focussed gradient waveforms to achieve a high signal and useful image contrast in short scan times. Despite these strengths, the clinical feasibility of balanced SSFP is still limited both by bright fat signal and by the signal voids that result from ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.013

    authors: Hargreaves BA,Bangerter NK,Shimakawa A,Vasanawala SS,Brittain JH,Nishimura DG

    更新日期:2006-02-01 00:00:00

  • A simple analytic method for estimating T2 in the knee from DESS.

    abstract:PURPOSE:To introduce a simple analytical formula for estimating T2 from a single Double-Echo in Steady-State (DESS) scan. METHODS:Extended Phase Graph (EPG) modeling was used to develop a straightforward linear approximation of the relationship between the two DESS signals, enabling accurate T2 estimation from one DES...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.12.018

    authors: Sveinsson B,Chaudhari AS,Gold GE,Hargreaves BA

    更新日期:2017-05-01 00:00:00

  • Electrocardiograph-triggered two-dimensional time-of-flight versus optimized contrast-enhanced three-dimensional MR angiography of the peripheral arteries.

    abstract::We determined whether the accuracy of magnetic resonance angiography (MRA) in the peripheral run-off vessels can be improved by using contrast-enhanced (CE) three-dimensional (3D) technique in comparison to electrocardiograph (ECG)-triggered two-dimensional (2D) time-of-flight (TOF) technique. In a prospective study 2...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00078-2

    authors: Vosshenrich R,Kopka L,Castillo E,Böttcher U,Graessner J,Grabbe E

    更新日期:1998-10-01 00:00:00

  • Analysis of machine-dependent and object-induced geometric distortion in 2DFT MR imaging.

    abstract::Geometric distortion in MR imaging predominantly arises from the inhomogeneity of the static field and the nonlinearity of the gradients. It is the purpose of this paper to analyse the object and machine related contributions to geometric distortion in order to determine which corrections are necessary for attaining a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90011-n

    authors: Bakker CJ,Moerland MA,Bhagwandien R,Beersma R

    更新日期:1992-01-01 00:00:00

  • Diffusion-weighted MRI and MR- volumetry--in the evaluation of tumor response after preoperative chemoradiotherapy in patients with locally advanced rectal cancer.

    abstract:PURPOSE:To determine the diagnostic performance of diffusion-weighted MRI and MR volumetry for the assessment of tumor response after preoperative chemoradiotherapy (CRT) in patients with locally advanced rectal cancer. MATERIALS AND METHODS:Forty-three patients with rectal cancer who underwent preoperative CRT were p...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.08.041

    authors: Birlik B,Obuz F,Elibol FD,Celik AO,Sokmen S,Terzi C,Sagol O,Sarioglu S,Gorken I,Oztop I

    更新日期:2015-02-01 00:00:00

  • Quantitative diffusion MRI using reduced field-of-view and multi-shot acquisition techniques: Validation in phantoms and prostate imaging.

    abstract:PURPOSE:To evaluate the reproducibility of quantitative diffusion measurements obtained with reduced Field of View (rFOV) and Multi-shot EPI (msEPI) acquisitions, using single-shot EPI (ssEPI) as a reference. METHODS:Diffusion phantom experiments, and prostate diffusion-weighted imaging in healthy volunteers and patie...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.04.006

    authors: Zhang Y,Holmes J,Rabanillo I,Guidon A,Wells S,Hernando D

    更新日期:2018-09-01 00:00:00

  • Prolonged T1 in patients with liver cirrhosis: an in vivo MRI study.

    abstract::Fifteen patients with liver cirrhosis and two control groups were examined. The first control group consisted of 7 healthy volunteers, and the second group of 17 patients with nonfocal liver diseases. The T1 and T2 relaxation times were calculated from signal intensities read out from a region of interest centrally lo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(90)90137-q

    authors: Thomsen C,Christoffersen P,Henriksen O,Juhl E

    更新日期:1990-01-01 00:00:00

  • Acoustic-integrated dynamic MR imaging for a patient with obstructive sleep apnea.

    abstract::Obstructive sleep apnea syndrome (OSAS) is caused by multi-level upper airway obstruction. Anatomic changes at the sites of obstruction may modify the physical or acoustic properties of snores. The surgical success of OSA depends upon precise localization of obstructed levels. We present a case of OSAS who received si...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.08.004

    authors: Chen YJ,Shih TT,Chang YC,Hsu YC,Huon LK,Lo MT,Pham VT,Lin C,Wang PC

    更新日期:2015-12-01 00:00:00

  • Biliary cystadenocarcinoma: seven year follow-up and the role of MRI and MRCP.

    abstract::Biliary cystadenomas and their malignant counterparts, biliary cystadenocarcinomas, are rare cystic tumors that arise from hepatobiliary epithelium. Ultrasound (US) and computed tomography (CT) are the initial imaging modalities used for the evaluation of biliary cystic tumors, but are not specific. MRI and MRCP, beca...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00453-2

    authors: Williams DM,Vitellas KM,Sheafor D

    更新日期:2001-11-01 00:00:00

  • Effect of physiological heart rate variability on quantitative T2 measurement with ECG-gated Fast Spin Echo (FSE) sequence and its retrospective correction.

    abstract:OBJECT:Quantitative T2 measurement is applied in cardiac Magnetic Resonance Imaging (MRI) for the diagnosis and follow-up of myocardial pathologies. Standard Electrocardiogram (ECG)-gated fast spin echo pulse sequences can be used clinically for T2 assessment, with multiple breath-holds. However, heart rate is subject ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.06.006

    authors: de Roquefeuil M,Vuissoz PA,Escanyé JM,Felblinger J

    更新日期:2013-11-01 00:00:00

  • A non-invasive technique for 3-dimensional assessment of articular cartilage thickness based on MRI. Part 1: Development of a computational method.

    abstract::Articular cartilage thickness is of relevance in various fields in diagnostics and biomedical research. In view of recent improvements of MR cartilage imaging a computational method has been developed for three-dimensional determination of cartilage thickness from tomographic datasets. A correction algorithm that comp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00012-x

    authors: Lösch A,Eckstein F,Haubner M,Englmeier KH

    更新日期:1997-01-01 00:00:00

  • Comparison of BLADE and conventional T2-TSE sequences for the sagittal visualization of the cervical spinal cord in multiple sclerosis patients - a case report.

    abstract::The purpose of this study is to report the significant differences found in the identification of lesions in cervical spinal cord of two patients with multiple sclerosis when using the BLADE T2-TSE and BLADE T2-TIRM sequences as opposed to the conventional T2-TSE and T2-TIRM sequences for sagittal acquisition at 1.5T....

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.07.008

    authors: Lavdas E,Mavroidis P,Topaltzikis T,Slatinopoulos V,Roka V,Vlachopoulou A,Papanikolaou N,Stathakis S,Kapsalaki E,Batsikas G

    更新日期:2013-12-01 00:00:00

  • Functional MR imaging of visual and motor cortex stimulation at high temporal resolution using a FLASH technique on a standard 1.5 Tesla scanner.

    abstract::Functional magnetic resonance imaging (fMRI) was performed on a conventional 1.5 T scanner by means of a modified FLASH-technique at temporal resolutions of 80 and 320 ms. The method's stability was assessed by phantom measurements and by investigation of three volunteers resulting in a low amplitude (3%) periodic (4 ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(96)00021-5

    authors: Wiener E,Schad LR,Baudendistel KT,Essig M,Müller E,Lorenz WJ

    更新日期:1996-01-01 00:00:00

  • Characterization of light hydrocarbon reservoirs by gradient-NMR well logging.

    abstract::New methods for acquiring and processing gradient NMR well log data enable signals from gas, light oil, and water to be unambiguously separated and, in many cases, quantified. These methods exploit the combined effects of T1-based and diffusion-based contrast on log response. T1 contrast, which separates the water and...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00162-2

    authors: Mardon D,Prammer MG,Coates GR

    更新日期:1996-01-01 00:00:00

  • Functional magnetic resonance imaging in a stereotactic setup.

    abstract::The localization of critical structures within the brain is important for the planning of therapeutic strategies. Functional MRI is capable to assess functional response of cortical structures to certain stimuli. The authors present two techniques for functional MRI (fMRI) in a stereotactic set-up. The skull of the pa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)02108-x

    authors: Debus J,Essig M,Schad LR,Wenz F,Baudendistel K,Knopp MV,Engenhart R,Lorenz WJ

    更新日期:1996-01-01 00:00:00

  • A deep learning approach to estimation of subject-level bias and variance in high angular resolution diffusion imaging.

    abstract::The ability to evaluate empirical diffusion MRI acquisitions for quality and to correct the resulting imaging metrics allows for improved inference and increased replicability. Previous work has shown promise for estimation of bias and variance of generalized fractional anisotropy (GFA) but comes at the price of compu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.03.021

    authors: Hainline AE,Nath V,Parvathaneni P,Schilling KG,Blaber JA,Anderson AW,Kang H,Landman BA

    更新日期:2019-06-01 00:00:00

  • Diffusion MRI detects longitudinal white matter changes in the 3xTg-AD mouse model of Alzheimer's disease.

    abstract::The sensitivity of multiple diffusion MRI (dMRI) parameters to longitudinal changes in white matter microstructure was investigated for the 3xTg-AD transgenic mouse model of Alzheimer's disease, which manifests both amyloid beta plaques and neurofibrillary tangles. By employing a specific dMRI method known as diffusio...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.12.003

    authors: Nie X,Falangola MF,Ward R,McKinnon ET,Helpern JA,Nietert PJ,Jensen JH

    更新日期:2019-04-01 00:00:00