Abstract:
:The purpose of this study was to evaluate the value of Ferumoxide-enhanced magnetic resonance (MR) imaging in the detection of hepatic metastases in high-risk patients treated for colorectal cancer that have rising CEA. We used 19 patients treated previously for colorectal cancer with rising CEA levels underwent an unenhanced T(1)-weighted (T1W), T(2)-weighted (T2W), STIR, and Ferumoxide-enhanced hepatic MRI. Following these studies, a laparotomy was performed and the liver was evaluated by palpation and intraoperative ultrasound. Two observers who were blinded to surgical results evaluated each MR sequence separately. The number of lesions considered highly suspicious for metastatic lesions were determined for each sequence and were compared to the results of surgery. The McNemar test was used to compare the outcomes of the different sequences. MR Imaging was unable to detect small (<5 mm) metastases discovered at surgery. The best non-contrast sequences for detecting metastases were the STIR with 42% sensitivity, 83% specificity and an overall accuracy of 56% and the T1W sequence (sensitivity 38%, specificity 100%, accuracy 57%), which were not significantly different (p 0.4). The noncontrast T2W sequence had a sensitivity of 29% and a specificity of 77% with an overall accuracy of 46%. When all pre contrast scans were grouped together the common sensitivity was 42%, specificity was 77% and accuracy was 54%. The post-ferumoxide T(2)W scans had a sensitivity of 42%, specificity of 85%, and accuracy of 57%, but did not detect any additional lesions. There was no statistical difference between the pre- and post-contrast studies with regard to identifying patients with metastatic disease (p 0.1). In conclusion, we found small hepatic metastases in patients with early signs of recurrent colorectal cancer are difficult to detect on MRI. Ferumoxide-enhanced MRI was unable to detect additional hepatic metastases and performed no better than unenhanced MRI in detecting small hepatic metastasis.
journal_name
Magn Reson Imagingjournal_title
Magnetic resonance imagingauthors
Said B,McCart JA,Libutti SK,Choyke PLdoi
10.1016/s0730-725x(99)00134-4subject
Has Abstractpub_date
2000-04-01 00:00:00pages
305-9issue
3eissn
0730-725Xissn
1873-5894pii
S0730-725X(99)00134-4journal_volume
18pub_type
临床试验,杂志文章abstract::Acetaminophen (APAP) toxicity is responsible for approximately half of all cases of acute liver failure in the United States. The mouse model of APAP toxicity is widely used to examine mechanisms of APAP toxicity. Noninvasive approaches would allow for serial measurements in a single animal to study the effects of exp...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2011.09.023
更新日期:2012-02-01 00:00:00
abstract::It is a big challenge to segment magnetic resonance (MR) images with intensity inhomogeneity. The widely used segmentation algorithms are region based, which mostly rely on the intensity homogeneity, and could bring inaccurate results. In this paper, we propose a novel region-based active contour model in a variationa...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2012.10.010
更新日期:2013-05-01 00:00:00
abstract::Present knowledge suggests that in glioblastoma multiforme the value of the apparent diffusion coefficient (ADC) is elevated in the solid part and hyperintense in T1, in spite of the elevated cellularity, and also in areas where peritumoral vasogenic edema is present. The purpose of our study has been to verify in viv...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(02)00594-5
更新日期:2002-11-01 00:00:00
abstract::Within the magnetic resonance imaging (MRI) community the trend is going to higher and higher magnetic fields, ranging from 1.5 T to 7 T, corresponding to Larmor frequencies of 63.8-298 MHz. Since for high-field MRI the magnetization increases with the applied magnetic field, the signal-to-noise-ratio increases as wel...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2012.06.014
更新日期:2013-02-01 00:00:00
abstract::Stimulated spin-echo and Carr-Purcell pulse sequences, with pulsed magnetic field gradients, have been used to study the self-diffusion processes of the water in swollen and in supercoiled polyacrylamide gels and in polysaccharides agarose gels, for different polymer concentrations. Restricted diffusion effects are ev...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(96)00202-0
更新日期:1996-01-01 00:00:00
abstract::A simple model for estimating temperature distribution within the frozen region during cryo ablation was tested for accuracy. Freezing experiments were conducted in both ex vivo and in vivo porcine livers. Temperature was measured during freezing using a fiber-optic temperature sensor. Three-dimensional MR images were...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(01)00389-7
更新日期:2001-06-01 00:00:00
abstract::Resting fluctuations in arterial CO2 (a cerebral vasodilator) are believed to be an important source of low-frequency blood oxygenation level dependent (BOLD) signal fluctuations. In this study we focus on the two commonly used resting-states in functional magnetic resonance imaging experiments, eyes open and eyes clo...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2012.06.013
更新日期:2013-04-01 00:00:00
abstract::Interventions for peripheral arterial disease should be designed to treat a physiological rather than an anatomic defect. Thus, for vascular surgeons, functional information about stenoses is as important as the anatomic one. In case of finding a stenosis by the use of magnetic resonance angiography, it would be a mat...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2008.01.013
更新日期:2008-10-01 00:00:00
abstract::Rapid maturational brain changes occur during adolescence--a time associated with risk-taking behaviors and improvements in cognition. The present study examined the relationship between white matter (WM) microstructure, impulsive behavior and response inhibition in female and male adolescents. Twenty-one healthy adol...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2006.03.012
更新日期:2006-09-01 00:00:00
abstract::Surface modification of liposomes containing Gd-diethylenetriaminepentaacetyl-phosphatidylethanolamine (Gd-DTPA-PE) as an amphiphilic paramagnetic label influences their contrast properties as MRI agents. Liposomes with the mean diameter ca. 220 nm and 10% mol content of Gd-DTPA-PE were modified with dextran (molecula...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)00083-f
更新日期:1995-01-01 00:00:00
abstract::The evaluation of local muscle recruitment during a specific movement can be done indirectly by measuring changes in local blood flow. Intravoxel incoherent motion perfusion imaging exploits some properties of the magnetic resonance to measure locally microvascular perfusion, and seems ideally suited for this task. We...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.08.005
更新日期:2017-01-01 00:00:00
abstract::We assessed the magnetic resonance (MR) imaging characteristics of two categories of epileptogenic substrates, neoplasms, and vascular malformations, to determine MR sensitivity and typical imaging features. A blinded retrospective analysis was performed on MR scans from 41 patients who had a neoplasm or vascular malf...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(95)02026-p
更新日期:1995-01-01 00:00:00
abstract::Diffraction ideas were first introduced to NMR by Mansfield and Grannell. Here we compare "Mansfield (k-space) diffraction" with the "diffusive (q-space) diffraction," noting their similarities and differences. The diffusive-diffraction concept is extremely helpful in elucidating the Pulsed Gradient Spin Echo NMR expe...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(96)00152-x
更新日期:1996-01-01 00:00:00
abstract::Balanced steady-state free precession (SSFP) sequences use fully re-focussed gradient waveforms to achieve a high signal and useful image contrast in short scan times. Despite these strengths, the clinical feasibility of balanced SSFP is still limited both by bright fat signal and by the signal voids that result from ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2005.10.013
更新日期:2006-02-01 00:00:00
abstract::We have synthesized a surface functionalized superparamagnetic iron oxide colloid whose clearance from the vascular compartment was inhibited by asialofetuin but not fetuin. Unlike other particulate or colloidal magnetic resonance (MR) contrast agents, the agent of the current communication is not withdrawn from the v...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(90)90143-p
更新日期:1990-01-01 00:00:00
abstract::A dextran-Gd-DTPA compound has been recently synthesized utilizing 70,800 Da molecular weight dextran. This polymeric contrast agent for magnetic resonance imaging has been found chemically to be very stable and to demonstrate in vitro improved relaxivities of 1.5 to 2.3 times that of monomeric Gd-DTPA at 100 MHz. Thi...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(92)90515-2
更新日期:1992-01-01 00:00:00
abstract::White matter loss, ventricular enlargement and white matter lesions are common findings on brain scans of older subjects. Accurate assessment of these different features is therefore essential for normal aging research. Recently, we developed a novel unsupervised classification method, named 'Multispectral Coloring Mo...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2011.09.016
更新日期:2012-02-01 00:00:00
abstract::The non-Einstein diffusion behavior of water in a model biological tissue system, intact duck embryos, has been investigated by the use of an in vivo proton pulsed-gradient spin-echo (PGSE) MR imaging technique. Multiple-frame MR images of the intact duck embryos and control solution (0.5 mM CuSO4 doped water) were ac...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(93)90476-t
更新日期:1993-01-01 00:00:00
abstract::High-resolution, single-slice, high spatial and spectral resolution (HiSS) breast magnetic resonance imaging (MRI) provides improved lesion conspicuity, margin definition and internal definition, as compared to conventional clinical MRI - and thus may provide better lesion characterization and increase breast MRI spec...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2009.05.022
更新日期:2010-01-01 00:00:00
abstract::The purpose of this study was to assess the benefits of a 3 T scanner and an eight-channel phased-array head coil for acquiring three-dimensional PRESS (Point REsolved Spectral Selection) proton (H-1) magnetic resonance spectroscopic imaging (MRSI) data from the brains of volunteers and patients with brain tumors rela...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2006.07.012
更新日期:2006-12-01 00:00:00
abstract::Currently, the North American symptomatic carotid endarterectomy trial, European carotid surgery trial, and common carotid method are used to measure the carotid stenosis for determining candidates for carotid endarterectomy using the projection angiography from different modalities such as digital subtraction angiogr...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2004.01.007
更新日期:2004-04-01 00:00:00
abstract::Quantitative MRI of neuromelanin (NM) containing structures (referred to as NM-MRI) in the brainstem, namely the locus coeruleus (LC) and substantia nigra (SN), may assist with the early detection of Parkinson's disease (PD) and Alzheimer's disease (AD) as well as differential diagnosis in the early disease stages. In...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2014.07.003
更新日期:2014-12-01 00:00:00
abstract:PURPOSE:The purpose of this study was to determine the pre- and postpubertal 1H magnetic resonance spectroscopic characteristics of the normal testis to establish baseline values for further clinical studies. MATERIALS AND METHODS:The subjects consisted of male volunteers, of whom 19 were prepubertal with ages between...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2007.06.008
更新日期:2008-02-01 00:00:00
abstract::New applications of the NMR-MOUSE (mobile universal surface explorer) to non-destructive quality control of elastomers are reported. One example concern the thermal aging of fast clutches which was probed by measurements of 1H transverse relaxation time. Novel methodological developments show that 1H double-quantum fi...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(01)00277-6
更新日期:2001-04-01 00:00:00
abstract::1H Magnetic resonance imaging and 31P magnetic resonance spectroscopy (MRS) have been carried out in experimental rodent filariasis, i.e., Acanthocheilonema viteae infection in the rodent host, Mastomys coucha. The T2-weighted image of the infected host shows fine hyperintense thread like structures of adult filariid ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(97)00180-x
更新日期:1997-01-01 00:00:00
abstract::To acquire high-resolution T(1)-weighted images of the liver in rats, for which breath-holding cannot be ensured, respiratory triggering is essential. At the respiratory rate of 30-60 times/min in rats, however, T(1)-weighted images cannot be obtained with simple triggering. As a simple solution to this, we applied mu...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2011.10.005
更新日期:2012-04-01 00:00:00
abstract::Magnetic field gradients play a fundamental role in MR imaging and localized spectroscopy. The MRI experiment, in particular fast MRI, relies on precise gradient switching, which has become more demanding with the constantly growing number of fast imaging techniques. Here we present a simple MR method to measure the b...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2007.02.002
更新日期:2007-11-01 00:00:00
abstract:PURPOSE:While PRESS is often employed to measure glutamate concentrations, MEGA-PRESS enables simultaneous Glx (glutamate and glutamine) and GABA measurements. This study aimed to compare validation, repeatability, and concordance of different approaches for glutamate quantification at 3T to aid future studies in their...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2017.12.029
更新日期:2018-05-01 00:00:00
abstract::L-2-Chloropropionic acid (L-CPA) is selectively toxic to rat cerebellar granule cells; necrosis is first observed about 36 hours after administration of L-CPA (750 mg/kg p.o.) becoming more marked by 48 h. Parallel to the onset of cell death an increase in cerebellar water content and sodium concentration has been rep...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(01)00231-4
更新日期:2001-02-01 00:00:00
abstract::Localized high-resolution diffusion tensor images (DTI) from the midbrain were obtained using reduced field-of-view (rFOV) methods combined with SENSE parallel imaging and single-shot echo planar (EPI) acquisitions at 7T. This combination aimed to diminish sensitivities of DTI to motion, susceptibility variations, and...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2013.01.013
更新日期:2013-07-01 00:00:00