Ferumoxide-enhanced MRI in patients with colorectal cancer and rising CEA: surgical correlation in early recurrence.

Abstract:

:The purpose of this study was to evaluate the value of Ferumoxide-enhanced magnetic resonance (MR) imaging in the detection of hepatic metastases in high-risk patients treated for colorectal cancer that have rising CEA. We used 19 patients treated previously for colorectal cancer with rising CEA levels underwent an unenhanced T(1)-weighted (T1W), T(2)-weighted (T2W), STIR, and Ferumoxide-enhanced hepatic MRI. Following these studies, a laparotomy was performed and the liver was evaluated by palpation and intraoperative ultrasound. Two observers who were blinded to surgical results evaluated each MR sequence separately. The number of lesions considered highly suspicious for metastatic lesions were determined for each sequence and were compared to the results of surgery. The McNemar test was used to compare the outcomes of the different sequences. MR Imaging was unable to detect small (<5 mm) metastases discovered at surgery. The best non-contrast sequences for detecting metastases were the STIR with 42% sensitivity, 83% specificity and an overall accuracy of 56% and the T1W sequence (sensitivity 38%, specificity 100%, accuracy 57%), which were not significantly different (p 0.4). The noncontrast T2W sequence had a sensitivity of 29% and a specificity of 77% with an overall accuracy of 46%. When all pre contrast scans were grouped together the common sensitivity was 42%, specificity was 77% and accuracy was 54%. The post-ferumoxide T(2)W scans had a sensitivity of 42%, specificity of 85%, and accuracy of 57%, but did not detect any additional lesions. There was no statistical difference between the pre- and post-contrast studies with regard to identifying patients with metastatic disease (p 0.1). In conclusion, we found small hepatic metastases in patients with early signs of recurrent colorectal cancer are difficult to detect on MRI. Ferumoxide-enhanced MRI was unable to detect additional hepatic metastases and performed no better than unenhanced MRI in detecting small hepatic metastasis.

journal_name

Magn Reson Imaging

authors

Said B,McCart JA,Libutti SK,Choyke PL

doi

10.1016/s0730-725x(99)00134-4

subject

Has Abstract

pub_date

2000-04-01 00:00:00

pages

305-9

issue

3

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(99)00134-4

journal_volume

18

pub_type

临床试验,杂志文章
  • Correlation of MRI findings to histology of acetaminophen toxicity in the mouse.

    abstract::Acetaminophen (APAP) toxicity is responsible for approximately half of all cases of acute liver failure in the United States. The mouse model of APAP toxicity is widely used to examine mechanisms of APAP toxicity. Noninvasive approaches would allow for serial measurements in a single animal to study the effects of exp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.09.023

    authors: Brown AT,Ou X,James LP,Jambhekar K,Pandey T,McCullough S,Chaudhuri S,Borrelli MJ

    更新日期:2012-02-01 00:00:00

  • Adaptive segmentation of magnetic resonance images with intensity inhomogeneity using level set method.

    abstract::It is a big challenge to segment magnetic resonance (MR) images with intensity inhomogeneity. The widely used segmentation algorithms are region based, which mostly rely on the intensity homogeneity, and could bring inaccurate results. In this paper, we propose a novel region-based active contour model in a variationa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.10.010

    authors: Liu L,Zhang Q,Wu M,Li W,Shang F

    更新日期:2013-05-01 00:00:00

  • Study on the variations of the apparent diffusion coefficient in areas of solid tumor in high grade gliomas.

    abstract::Present knowledge suggests that in glioblastoma multiforme the value of the apparent diffusion coefficient (ADC) is elevated in the solid part and hyperintense in T1, in spite of the elevated cellularity, and also in areas where peritumoral vasogenic edema is present. The purpose of our study has been to verify in viv...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00594-5

    authors: Muti M,Aprile I,Principi M,Italiani M,Guiducci A,Giulianelli G,Ottaviano P

    更新日期:2002-11-01 00:00:00

  • Magnetic resonance imaging at frequencies below 1 kHz.

    abstract::Within the magnetic resonance imaging (MRI) community the trend is going to higher and higher magnetic fields, ranging from 1.5 T to 7 T, corresponding to Larmor frequencies of 63.8-298 MHz. Since for high-field MRI the magnetization increases with the applied magnetic field, the signal-to-noise-ratio increases as wel...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.014

    authors: Hilschenz I,Körber R,Scheer HJ,Fedele T,Albrecht HH,Mario Cassará A,Hartwig S,Trahms L,Haase J,Burghoff M

    更新日期:2013-02-01 00:00:00

  • NMR study of the diffusion processes in gels.

    abstract::Stimulated spin-echo and Carr-Purcell pulse sequences, with pulsed magnetic field gradients, have been used to study the self-diffusion processes of the water in swollen and in supercoiled polyacrylamide gels and in polysaccharides agarose gels, for different polymer concentrations. Restricted diffusion effects are ev...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00202-0

    authors: Pavesi L,Balzarini M

    更新日期:1996-01-01 00:00:00

  • Validation of estimated 3D temperature maps during hepatic cryo surgery.

    abstract::A simple model for estimating temperature distribution within the frozen region during cryo ablation was tested for accuracy. Freezing experiments were conducted in both ex vivo and in vivo porcine livers. Temperature was measured during freezing using a fiber-optic temperature sensor. Three-dimensional MR images were...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00389-7

    authors: Samset E,Mala T,Edwin B,Gladhaug I,Søreide O,Fosse E

    更新日期:2001-06-01 00:00:00

  • The effects of respiratory CO2 fluctuations in the resting-state BOLD signal differ between eyes open and eyes closed.

    abstract::Resting fluctuations in arterial CO2 (a cerebral vasodilator) are believed to be an important source of low-frequency blood oxygenation level dependent (BOLD) signal fluctuations. In this study we focus on the two commonly used resting-states in functional magnetic resonance imaging experiments, eyes open and eyes clo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.013

    authors: Peng T,Niazy R,Payne SJ,Wise RG

    更新日期:2013-04-01 00:00:00

  • Quantification of blood flow velocity in stenosed arteries by the use of finite elements: an observer-independent noninvasive method.

    abstract::Interventions for peripheral arterial disease should be designed to treat a physiological rather than an anatomic defect. Thus, for vascular surgeons, functional information about stenoses is as important as the anatomic one. In case of finding a stenosis by the use of magnetic resonance angiography, it would be a mat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.01.013

    authors: Mühlthaler H,Quatember B,Fraedrich G,Mühlthaler M,Pfeifer B,Greiner A,Schocke MF

    更新日期:2008-10-01 00:00:00

  • Sex differences in the relationship between white matter microstructure and impulsivity in adolescents.

    abstract::Rapid maturational brain changes occur during adolescence--a time associated with risk-taking behaviors and improvements in cognition. The present study examined the relationship between white matter (WM) microstructure, impulsive behavior and response inhibition in female and male adolescents. Twenty-one healthy adol...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.03.012

    authors: Silveri MM,Rohan ML,Pimentel PJ,Gruber SA,Rosso IM,Yurgelun-Todd DA

    更新日期:2006-09-01 00:00:00

  • Controlled delivery of Gd-containing liposomes to lymph nodes: surface modification may enhance MRI contrast properties.

    abstract::Surface modification of liposomes containing Gd-diethylenetriaminepentaacetyl-phosphatidylethanolamine (Gd-DTPA-PE) as an amphiphilic paramagnetic label influences their contrast properties as MRI agents. Liposomes with the mean diameter ca. 220 nm and 10% mol content of Gd-DTPA-PE were modified with dextran (molecula...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)00083-f

    authors: Trubetskoy VS,Cannillo JA,Milshtein A,Wolf GL,Torchilin VP

    更新日期:1995-01-01 00:00:00

  • Selective microvascular muscle perfusion imaging in the shoulder with intravoxel incoherent motion (IVIM).

    abstract::The evaluation of local muscle recruitment during a specific movement can be done indirectly by measuring changes in local blood flow. Intravoxel incoherent motion perfusion imaging exploits some properties of the magnetic resonance to measure locally microvascular perfusion, and seems ideally suited for this task. We...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.08.005

    authors: Nguyen A,Ledoux JB,Omoumi P,Becce F,Forget J,Federau C

    更新日期:2017-01-01 00:00:00

  • MR characteristics of neoplasms and vascular malformations associated with epilepsy.

    abstract::We assessed the magnetic resonance (MR) imaging characteristics of two categories of epileptogenic substrates, neoplasms, and vascular malformations, to determine MR sensitivity and typical imaging features. A blinded retrospective analysis was performed on MR scans from 41 patients who had a neoplasm or vascular malf...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02026-p

    authors: Bronen RA,Fulbright RK,Spencer DD,Spencer SS,Kim JH,Lange RC

    更新日期:1995-01-01 00:00:00

  • NMR imaging, NMR diffraction and applications of pulsed gradient spin echoes in porous media.

    abstract::Diffraction ideas were first introduced to NMR by Mansfield and Grannell. Here we compare "Mansfield (k-space) diffraction" with the "diffusive (q-space) diffraction," noting their similarities and differences. The diffusive-diffraction concept is extremely helpful in elucidating the Pulsed Gradient Spin Echo NMR expe...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00152-x

    authors: Callaghan PT

    更新日期:1996-01-01 00:00:00

  • Dual-acquisition phase-sensitive fat-water separation using balanced steady-state free precession.

    abstract::Balanced steady-state free precession (SSFP) sequences use fully re-focussed gradient waveforms to achieve a high signal and useful image contrast in short scan times. Despite these strengths, the clinical feasibility of balanced SSFP is still limited both by bright fat signal and by the signal voids that result from ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.013

    authors: Hargreaves BA,Bangerter NK,Shimakawa A,Vasanawala SS,Brittain JH,Nishimura DG

    更新日期:2006-02-01 00:00:00

  • A functionalized superparamagnetic iron oxide colloid as a receptor directed MR contrast agent.

    abstract::We have synthesized a surface functionalized superparamagnetic iron oxide colloid whose clearance from the vascular compartment was inhibited by asialofetuin but not fetuin. Unlike other particulate or colloidal magnetic resonance (MR) contrast agents, the agent of the current communication is not withdrawn from the v...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90143-p

    authors: Josephson L,Groman EV,Menz E,Lewis JM,Bengele H

    更新日期:1990-01-01 00:00:00

  • In vivo MR evaluation of Gd-DTPA conjugated to dextran in normal rabbits.

    abstract::A dextran-Gd-DTPA compound has been recently synthesized utilizing 70,800 Da molecular weight dextran. This polymeric contrast agent for magnetic resonance imaging has been found chemically to be very stable and to demonstrate in vitro improved relaxivities of 1.5 to 2.3 times that of monomeric Gd-DTPA at 100 MHz. Thi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90515-2

    authors: Li KC,Quisling RG,Armitage FE,Richardson D,Mladinich C

    更新日期:1992-01-01 00:00:00

  • Automatic segmentation of brain white matter and white matter lesions in normal aging: comparison of five multispectral techniques.

    abstract::White matter loss, ventricular enlargement and white matter lesions are common findings on brain scans of older subjects. Accurate assessment of these different features is therefore essential for normal aging research. Recently, we developed a novel unsupervised classification method, named 'Multispectral Coloring Mo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.09.016

    authors: Valdés Hernández Mdel C,Gallacher PJ,Bastin ME,Royle NA,Maniega SM,Deary IJ,Wardlaw JM

    更新日期:2012-02-01 00:00:00

  • Quantitation of non-Einstein diffusion behavior of water in biological tissues by proton MR diffusion imaging: synthetic image calculations.

    abstract::The non-Einstein diffusion behavior of water in a model biological tissue system, intact duck embryos, has been investigated by the use of an in vivo proton pulsed-gradient spin-echo (PGSE) MR imaging technique. Multiple-frame MR images of the intact duck embryos and control solution (0.5 mM CuSO4 doped water) were ac...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90476-t

    authors: Cheng KH

    更新日期:1993-01-01 00:00:00

  • Clinical implementation of a multislice high spectral and spatial resolution-based MRI sequence to achieve unilateral full-breast coverage.

    abstract::High-resolution, single-slice, high spatial and spectral resolution (HiSS) breast magnetic resonance imaging (MRI) provides improved lesion conspicuity, margin definition and internal definition, as compared to conventional clinical MRI - and thus may provide better lesion characterization and increase breast MRI spec...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.022

    authors: Medved M,Newstead GM,Abe H,Olopade OI,Shimauchi A,Zamora MA,Karczmar GS

    更新日期:2010-01-01 00:00:00

  • Considerations in applying 3D PRESS H-1 brain MRSI with an eight-channel phased-array coil at 3 T.

    abstract::The purpose of this study was to assess the benefits of a 3 T scanner and an eight-channel phased-array head coil for acquiring three-dimensional PRESS (Point REsolved Spectral Selection) proton (H-1) magnetic resonance spectroscopic imaging (MRSI) data from the brains of volunteers and patients with brain tumors rela...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.07.012

    authors: Li Y,Osorio JA,Ozturk-Isik E,Chen AP,Xu D,Crane JC,Cha S,Chang S,Berger MS,Vigneron DB,Nelson SJ

    更新日期:2006-12-01 00:00:00

  • Computerized quantification of carotid artery stenosis using MRA axial images.

    abstract::Currently, the North American symptomatic carotid endarterectomy trial, European carotid surgery trial, and common carotid method are used to measure the carotid stenosis for determining candidates for carotid endarterectomy using the projection angiography from different modalities such as digital subtraction angiogr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.007

    authors: Kim DY,Park JW

    更新日期:2004-04-01 00:00:00

  • Simultaneous imaging of locus coeruleus and substantia nigra with a quantitative neuromelanin MRI approach.

    abstract::Quantitative MRI of neuromelanin (NM) containing structures (referred to as NM-MRI) in the brainstem, namely the locus coeruleus (LC) and substantia nigra (SN), may assist with the early detection of Parkinson's disease (PD) and Alzheimer's disease (AD) as well as differential diagnosis in the early disease stages. In...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.07.003

    authors: Chen X,Huddleston DE,Langley J,Ahn S,Barnum CJ,Factor SA,Levey AI,Hu X

    更新日期:2014-12-01 00:00:00

  • 1H magnetic resonance spectroscopy of the normal testis: preliminary findings.

    abstract:PURPOSE:The purpose of this study was to determine the pre- and postpubertal 1H magnetic resonance spectroscopic characteristics of the normal testis to establish baseline values for further clinical studies. MATERIALS AND METHODS:The subjects consisted of male volunteers, of whom 19 were prepubertal with ages between...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.06.008

    authors: Firat AK,Uğraş M,Karakaş HM,Erdem G,Kurus M,Ugras M,Celik T,Kahraman B,Doğanay S

    更新日期:2008-02-01 00:00:00

  • The NMR-MOUSE: quality control of elastomers.

    abstract::New applications of the NMR-MOUSE (mobile universal surface explorer) to non-destructive quality control of elastomers are reported. One example concern the thermal aging of fast clutches which was probed by measurements of 1H transverse relaxation time. Novel methodological developments show that 1H double-quantum fi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00277-6

    authors: Kühn H,Klein M,Wiesmath A,Demco DE,Blümich B,Kelm J,Gold PW

    更新日期:2001-04-01 00:00:00

  • 1H magnetic resonance imaging and 31P magnetic resonance spectroscopy in experimental filariasis.

    abstract::1H Magnetic resonance imaging and 31P magnetic resonance spectroscopy (MRS) have been carried out in experimental rodent filariasis, i.e., Acanthocheilonema viteae infection in the rodent host, Mastomys coucha. The T2-weighted image of the infected host shows fine hyperintense thread like structures of adult filariid ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00180-x

    authors: Shukla-Dave A,Fatma N,Roy R,Srivastava S,Chatterjee RK,Govindaraju V,Viswanathan AK,Raghunathan P

    更新日期:1997-01-01 00:00:00

  • A simple way to acquire T(1)-weighted MR images of rat liver with respiratory triggering.

    abstract::To acquire high-resolution T(1)-weighted images of the liver in rats, for which breath-holding cannot be ensured, respiratory triggering is essential. At the respiratory rate of 30-60 times/min in rats, however, T(1)-weighted images cannot be obtained with simple triggering. As a simple solution to this, we applied mu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.10.005

    authors: Morikawa S,Murayama H,Fujimoto S,Shiino A,Inubushi T

    更新日期:2012-04-01 00:00:00

  • Simple phase method for measurement of magnetic field gradient waveforms.

    abstract::Magnetic field gradients play a fundamental role in MR imaging and localized spectroscopy. The MRI experiment, in particular fast MRI, relies on precise gradient switching, which has become more demanding with the constantly growing number of fast imaging techniques. Here we present a simple MR method to measure the b...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.02.002

    authors: Latta P,Gruwel ML,Volotovskyy V,Weber MH,Tomanek B

    更新日期:2007-11-01 00:00:00

  • Glutamate quantification by PRESS or MEGA-PRESS: Validation, repeatability, and concordance.

    abstract:PURPOSE:While PRESS is often employed to measure glutamate concentrations, MEGA-PRESS enables simultaneous Glx (glutamate and glutamine) and GABA measurements. This study aimed to compare validation, repeatability, and concordance of different approaches for glutamate quantification at 3T to aid future studies in their...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.12.029

    authors: van Veenendaal TM,Backes WH,van Bussel FCG,Edden RAE,Puts NAJ,Aldenkamp AP,Jansen JFA

    更新日期:2018-05-01 00:00:00

  • MRI studies of the neurotoxic effects of L-2-chloropropionic acid on rat brain.

    abstract::L-2-Chloropropionic acid (L-CPA) is selectively toxic to rat cerebellar granule cells; necrosis is first observed about 36 hours after administration of L-CPA (750 mg/kg p.o.) becoming more marked by 48 h. Parallel to the onset of cell death an increase in cerebellar water content and sodium concentration has been rep...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00231-4

    authors: Williams RE,Prior M,Bachelard HS,Waterton JC,Checkley D,Lock EA

    更新日期:2001-02-01 00:00:00

  • Localized high-resolution DTI of the human midbrain using single-shot EPI, parallel imaging, and outer-volume suppression at 7T.

    abstract::Localized high-resolution diffusion tensor images (DTI) from the midbrain were obtained using reduced field-of-view (rFOV) methods combined with SENSE parallel imaging and single-shot echo planar (EPI) acquisitions at 7T. This combination aimed to diminish sensitivities of DTI to motion, susceptibility variations, and...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.01.013

    authors: Wargo CJ,Gore JC

    更新日期:2013-07-01 00:00:00