1H magnetic resonance spectroscopy of the normal testis: preliminary findings.

Abstract:

PURPOSE:The purpose of this study was to determine the pre- and postpubertal 1H magnetic resonance spectroscopic characteristics of the normal testis to establish baseline values for further clinical studies. MATERIALS AND METHODS:The subjects consisted of male volunteers, of whom 19 were prepubertal with ages between 7 and 13 years and 24 were postpubertal with ages between 19 and 39 years. Their testes were evaluated at 1.5 T with magnetic resonance spectroscopy; in addition, testis volumes were measured. Major metabolite peaks were identified and their ratios were calculated. Metabolite differences of testis between pre- and postpubertal age were analyzed. RESULTS:Major constituents of spectra were 3.21 ppm choline and 0.9-1.3 ppm lipid peaks. At the echo time (TE) spectrum of 31 ms, choline/lipid ratios ranged from 0.35 to 8.30 (mean=1.87) in postpubertal males and from 0.06 to 5.45 (mean=0.88) in prepubertal males (P<.013). At the TE spectrum of 136 ms, choline/lipid ratios ranged from 0.66 to 15.42 (mean=4.09) in postpubertal males and from 0.05 to 4.91 (mean=0.9) in prepubertal males (P<.016). CONCLUSIONS:Choline/lipid ratio was higher in the postpubertal period. The existence of higher choline peak in that age group should be due to the initiation of spermatogenesis. The decrease in the lipid peak may represent the effect of testosterone on testicular tissue or may be due to histochemical changes initiated by puberty. The significant decrease in choline/lipid ratio noted after puberty could represent the presence of spermatogenesis. This hypothesis should be evaluated by further studies on postpubertal subjects with impaired spermatogenesis.

journal_name

Magn Reson Imaging

authors

Firat AK,Uğraş M,Karakaş HM,Erdem G,Kurus M,Ugras M,Celik T,Kahraman B,Doğanay S

doi

10.1016/j.mri.2007.06.008

subject

Has Abstract

pub_date

2008-02-01 00:00:00

pages

215-20

issue

2

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(07)00346-3

journal_volume

26

pub_type

杂志文章
  • Computerized quantification of carotid artery stenosis using MRA axial images.

    abstract::Currently, the North American symptomatic carotid endarterectomy trial, European carotid surgery trial, and common carotid method are used to measure the carotid stenosis for determining candidates for carotid endarterectomy using the projection angiography from different modalities such as digital subtraction angiogr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.007

    authors: Kim DY,Park JW

    更新日期:2004-04-01 00:00:00

  • Phase detection and contrast loss in magnetic resonance imaging.

    abstract::Several recent articles have assessed the relative efficiency of nuclear magnetic resonance (NMR) pulse sequences. One consideration that has received little attention is the effect on image contrast of displaying images without information on the sign of the reconstructed signals. The radiofrequency receivers current...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(84)90193-0

    authors: Hendrick RE,Nelson TR,Hendee WR

    更新日期:1984-01-01 00:00:00

  • Bilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain.

    abstract::Deep brain stimulation (DBS) is used increasingly in the field of movement disorders. The implanted electrodes create not only a prior risk to patient safety during MRI, but also a unique opportunity in the collection of functional MRI data conditioned by direct neural stimulation. We evaluated MRI-related heating for...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.02.007

    authors: Bhidayasiri R,Bronstein JM,Sinha S,Krahl SE,Ahn S,Behnke EJ,Cohen MS,Frysinger R,Shellock FG

    更新日期:2005-05-01 00:00:00

  • A nonlinear regularization strategy for GRAPPA calibration.

    abstract::A regularization strategy is described for generalized autocalibrating partially parallel acquisition (GRAPPA) that allows successful calibration using a small number of autocalibration signals (ACS). The approach requires certain nonlinear relationships between the GRAPPA coefficients to be satisfied, which increases...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.05.005

    authors: Bydder M,Jung Y

    更新日期:2009-01-01 00:00:00

  • Diagnosis of suspicious breast lesions using an empirical mathematical model for dynamic contrast-enhanced MRI.

    abstract::The purpose of this study was to test whether an empirical mathematical model (EMM) of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) can distinguish between benign and malignant breast lesions. A modified clinical protocol was used to improve the sampling of contrast medium uptake and washout. T(1)-we...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.10.011

    authors: Fan X,Medved M,Karczmar GS,Yang C,Foxley S,Arkani S,Recant W,Zamora MA,Abe H,Newstead GM

    更新日期:2007-06-01 00:00:00

  • Three-dimensional adiabatic inversion recovery prepared ultrashort echo time cones (3D IR-UTE-Cones) imaging of cortical bone in the hip.

    abstract:PURPOSE:We present three-dimensional adiabatic inversion recovery prepared ultrashort echo time Cones (3D IR-UTE-Cones) imaging of cortical bone in the hip of healthy volunteers using a clinical 3T scanner. METHODS:A 3D IR-UTE-Cones sequence, based on a short pulse excitation followed by a 3D Cones trajectory, with a ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.07.012

    authors: Nazaran A,Carl M,Ma Y,Jerban S,Zhu Y,Lu X,Du J,Chang EY

    更新日期:2017-12-01 00:00:00

  • Electric current density imaging of bone by MRI.

    abstract::Current density imaging (CDI) has been shown to be a feasible method to map spatial distribution of electric currents through bone structures and for studying osteoporosis and bone fracture models. For the osteoporosis model, bone sample was moistened in a solution of a sodium salt of ethylendiamintetraacetic acid (ED...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00038-6

    authors: Beravs K,White D,Sersa I,Demsar F

    更新日期:1997-01-01 00:00:00

  • A simulation-based comparison of two methods for determining relaxation rates from relaxometry images.

    abstract::When assessing liver iron content using relaxometry, an average relaxation rate (R1, R2 or R2*) is usually determined from a region of interest or the entire liver. This is commonly performed by fitting the signal decay in individual voxels to an appropriate relaxation function. The voxel-level parameters resulting fr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.11.005

    authors: Marro K,Otto R,Kolokythas O,Shimamura A,Sanders JE,McDonald GB,Friedman SD

    更新日期:2011-05-01 00:00:00

  • Low-frequency signal changes reflect differences in functional connectivity between good readers and dyslexics during continuous phoneme mapping.

    abstract::The current fMRI study investigated correlations of low-frequency signal changes in the left inferior frontal gyrus, right inferior frontal gyrus and cerebellum in 13 adult dyslexic and 10 normal readers to examine functional networks associated with these regions. The extent of these networks to regions associated wi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.006

    authors: Stanberry LI,Richards TL,Berninger VW,Nandy RR,Aylward EH,Maravilla KR,Stock PS,Cordes D

    更新日期:2006-04-01 00:00:00

  • Functional evaluation of normal and ischemic kidney by means of gadolinium-DOTA enhanced TurboFLASH MR imaging: a preliminary comparison with 99Tc-MAG3 dynamic scintigraphy.

    abstract::The functional value of TurboFLASH MR imaging in the assessment of dynamic contrast enhancement and renal perfusion anomalies was evaluated in seven patients, who also underwent renal scintigraphy in baseline conditions. The basal renograms obtained from MAG-3 scintigraphy (mercapto acetyl triglycine, MAG3-S) and from...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92534-8

    authors: Laissy JP,Faraggi M,Lebtahi R,Soyer P,Brillet G,Méry JP,Menu Y,Le Guludec D

    更新日期:1994-01-01 00:00:00

  • High-resolution in vivo diffusion tensor imaging of the injured cat spinal cord using self-navigated, interleaved, variable-density spiral acquisition (SNAILS-DTI).

    abstract::Diffusion tensor magnetic resonance imaging (DTI) is useful for studying the microstructural changes in the spinal cord following traumatic injury; however, image quality is generally poor due to the small size of the spinal cord, physiological motion and susceptibility artifacts. Self-navigated, interleaved, variable...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.06.006

    authors: Ellingson BM,Sulaiman O,Kurpad SN

    更新日期:2010-11-01 00:00:00

  • Quantitative multi-modal functional MRI with blood oxygenation level dependent exponential decays adjusted for flow attenuated inversion recovery (BOLDED AFFAIR).

    abstract::A magnetic resonance imaging (MRI) method is described that allows interleaved measurements of transverse (R(2)(*) and R(2)) and longitudinal (R(1)) relaxation rates of tissue water in conjunction with spin labeling. The image-contrasts are intrinsically blood oxygenation level dependent (BOLD) and cerebral blood flow...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00125-9

    authors: Hyder F,Renken R,Kennan RP,Rothman DL

    更新日期:2000-04-01 00:00:00

  • Spine MR images in patients with pedicle screw fixation: Comparison of conventional and SEMAC-VAT sequences at 1.5 T.

    abstract:BACKGROUND AND PURPOSE:Slice-encoding metal artifact corrections (SEMAC)-view-angle tilting (VAT) sequences have recently been used in clinical protocols to reduce metal artifacts in MR scans of patients with spinal instrumentation. The objective of this study was to compare the SEMAC-VAT sequence with the conventional...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.08.002

    authors: Park C,Lee E,Yeo Y,Kang Y,Lee JW,Ahn JM,Kang HS

    更新日期:2018-12-01 00:00:00

  • Inherent spatial structure in myelin water fraction maps.

    abstract::Myelin water fraction (MWF) images in brain tend to be spatially noisy with unknown or no apparent spatial patterns structure, so values are therefore typically averaged over large white matter (WM) volumes. We investigated the existence of an inherent spatial structure in MWF maps and explored the benefits of examini...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.09.012

    authors: Baumeister TR,Kolind SH,MacKay AL,McKeown MJ

    更新日期:2020-04-01 00:00:00

  • The influence of stimulated echoes on contrast in fast spin-echo imaging.

    abstract::Tissue contrast obtained using fast spin-echo (FSE) and conventional spin-echo (SE) sequences is not identical and a number of mechanisms are thought to contribute to these contrast differences. The effect of stimulated echoes has previously been apparently ruled out as a contributing mechanism. Signal-to-noise ratios...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02110-f

    authors: Williams CF,Redpath TW,Smith FW

    更新日期:1996-01-01 00:00:00

  • Lateral ventricular cerebrospinal fluid diffusivity as a potential neuroimaging marker of brain temperature in multiple sclerosis: a hypothesis and implications.

    abstract::In this retrospective study we tested the hypothesis that the net effect of impaired electrical conduction and therefore increased heat dissipation in multiple sclerosis (MS) results in elevated lateral ventricular (LV) cerebrospinal fluid (CSF) diffusivity as a measure of brain temperature estimated in vivo using dif...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.11.002

    authors: Hasan KM,Lincoln JA,Nelson FM,Wolinsky JS,Narayana PA

    更新日期:2015-04-01 00:00:00

  • Noninvasive evaluation of radiation-enhanced glioma cells invasiveness by ultra-high-field (1)H-MRS in vitro.

    abstract:INTRODUCTION:Glioma is the most common type of the primary CNS tumor. Radiotherapy is an important treatment measure after surgery. However, its highly invasive character is the main reason of postoperative recurrence. The aim of the study was to probe the correlation between the invasion ability and the metabolite cha...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.05.009

    authors: Xu YJ,Cui Y,Li HX,Shi WQ,Li FY,Wang JZ,Zeng QS

    更新日期:2016-10-01 00:00:00

  • MR visible localization device for radiographic-pathologic correlation of surgical specimens.

    abstract:PURPOSE:The detection of small parenchymal hepatic lesions identified by preoperative imaging remains a challenge for traditional pathologic methods in large specimens. We developed a magnetic resonance imaging (MRI) compatible localization device for imaging of surgical specimens aimed to improve identification and lo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.11.021

    authors: Kinner S,Schubert TB,Nocerino EA,Hynes S,Colgan TJ,Loeffler AG,Brace C,Reeder SB,Winslow E

    更新日期:2017-04-01 00:00:00

  • A CT using longitudinally detected ESR (LODESR-CT) of intraperitoneally injected nitroxide radical in a rat's head.

    abstract::We have developed an in vivo longitudinally detected ESR (LODESR) imaging system operating at 700 MHz based on a loop-gap resonator and a pair of saddle-type pickup coils. A good linear relationship between the LODESR signal intensity and the applied power in a range up to 15.8 W was obtained. The detection of LODESR ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)82763-4

    authors: Yokoyama H,Sato T,Tsuchihashi N,Ogata T,Ohya-Nishiguchi H,Kamada H

    更新日期:1997-01-01 00:00:00

  • Effects of 3D sampling in (k, t)-space on temporal qualities of dynamic MRI.

    abstract::3D (kx, ky, t)-space analysis is invoked to provide insights into dynamic magnetic resonance imaging (DMRI) with arbitrary k-space sampling trajectories. The effects of 3D sampling in (kx, ky, t) are analyzed theoretically and verified with computer simulation. The analyses show that a 3D sampling pattern that is more...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.04.009

    authors: Park JB,Nishimura DG

    更新日期:2006-10-01 00:00:00

  • Noise estimation in single- and multiple-coil magnetic resonance data based on statistical models.

    abstract::Noise estimation is a challenging task in magnetic resonance imaging (MRI), with applications in quality assessment, filtering or diffusion tensor estimation. Main noise estimators based on the Rician model are revisited and classified in this article, and new useful methods are proposed. Additionally, all the surveye...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.025

    authors: Aja-Fernández S,Tristán-Vega A,Alberola-López C

    更新日期:2009-12-01 00:00:00

  • Technical evaluation of in vivo abdominal fat and IMCL quantification using MRI and MRSI at 3 T.

    abstract:OBJECTIVES:The objectives of this study were to develop protocols that measure abdominal fat and calf muscle lipids with magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS), respectively, at 3 T and to examine the correlation between these parameters and insulin sensitivity. MATERIALS AND METHOD...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.06.006

    authors: Li X,Youngren JF,Hyun B,Sakkas GK,Mulligan K,Majumdar S,Masharani UB,Schambelan M,Goldfine ID

    更新日期:2008-02-01 00:00:00

  • Accurate and sensitive measurements of magnetic susceptibility using echo planar imaging.

    abstract::Susceptibility differences are common causes for artifacts in magnetic resonance (MR); therefore, it is important to choose phantom materials in a way that these artifacts are kept at a minimum. In this study, a previously proposed MR imaging (MRI) method [Beuf O, Briguet A, Lissac M, Davis R. Magnetic resonance imagi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.07.005

    authors: Carlsson A,Starck G,Ljungberg M,Ekholm S,Forssell-Aronsson E

    更新日期:2006-11-01 00:00:00

  • Short T2 contrast with three-dimensional ultrashort echo time imaging.

    abstract::There is increasing interest in imaging short T2 species which show little or no signal with conventional magnetic resonance (MR) pulse sequences. In this paper, we describe the use of three-dimensional ultrashort echo time (3D UTE) sequences with TEs down to 8 μs for imaging of these species. Image contrast was gener...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.11.003

    authors: Du J,Bydder M,Takahashi AM,Carl M,Chung CB,Bydder GM

    更新日期:2011-05-01 00:00:00

  • Three dimensional k-space trajectory design using genetic algorithms.

    abstract::Image quality and total scan time in MRI are determined in large part by the trajectory employed to sample the Fourier space. Each trajectory has different properties like coverage of k-space, scan time, sensitivity to off-resonance conditions, etc. These properties are often contradictory, therefore a universal optim...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00174-7

    authors: Sabat S,Mir R,Guarini M,Guesalaga A,Irarrazaval P

    更新日期:2003-09-01 00:00:00

  • Echo-shifted multislice EPI for high-speed fMRI.

    abstract::The advantages of event-related functional Magnetic Resonance Imaging (fMRI) and the increasing use of fMRI in cognitive experiments are both driving the development of techniques that allow images sensitive to the blood oxygen level-dependent effect to be acquired at ever-higher temporal resolution. Here, we present ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.030

    authors: Gibson A,Peters AM,Bowtell R

    更新日期:2006-05-01 00:00:00

  • Influence of baseline hematocrit on between-subject BOLD signal change using gradient echo and asymmetric spin echo EPI.

    abstract::The dependence of BOLD signal change (BSC) on baseline hematocrit is in the process of being characterized, primarily using conventional Gradient Echo (GE) echo planar imaging (EPI). We describe the first empiric exploration of this relationship using, in addition to GE, Spin Echo (SE) and two Asymmetric Spin Echo EPI...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00083-3

    authors: Gustard S,Williams EJ,Hall LD,Pickard JD,Carpenter TA

    更新日期:2003-07-01 00:00:00

  • Three-dimensional magnetic resonance spectroscopic imaging of histologically confirmed brain tumors.

    abstract::The goal of this study was to determine whether presurgical metabolite levels measured by 3D MR Spectroscopic Imaging (MRSI) can accurately detect viable cancer within human brain tumor masses. A total of 31 patients (33 exams, 39 pathology correlations) with brain tumors were studied prior to surgical biopsy and/or r...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0730-725x(01)00225-9

    authors: Vigneron D,Bollen A,McDermott M,Wald L,Day M,Moyher-Noworolski S,Henry R,Chang S,Berger M,Dillon W,Nelson S

    更新日期:2001-01-01 00:00:00

  • A deep learning approach to estimation of subject-level bias and variance in high angular resolution diffusion imaging.

    abstract::The ability to evaluate empirical diffusion MRI acquisitions for quality and to correct the resulting imaging metrics allows for improved inference and increased replicability. Previous work has shown promise for estimation of bias and variance of generalized fractional anisotropy (GFA) but comes at the price of compu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.03.021

    authors: Hainline AE,Nath V,Parvathaneni P,Schilling KG,Blaber JA,Anderson AW,Kang H,Landman BA

    更新日期:2019-06-01 00:00:00

  • Improved sensitivity of MRI in multiple sclerosis by use of extensive standardized procedures.

    abstract::The relative value of two different MRI procedures for the assessment of infratentorial extension in multiple sclerosis (MS) was studied. Multislice spin-echo techniques were used overall. Procedure A consisted of parasagittal T1-weighted images (500/30) and axial T2-weighted images (2500/30, 2500/120). Procedure B co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90547-x

    authors: Van de Vyver FL,Truyen L,Gheuens J,Degryse HR,Peersman GV,Martin JJ

    更新日期:1989-05-01 00:00:00