Functional evaluation of normal and ischemic kidney by means of gadolinium-DOTA enhanced TurboFLASH MR imaging: a preliminary comparison with 99Tc-MAG3 dynamic scintigraphy.

Abstract:

:The functional value of TurboFLASH MR imaging in the assessment of dynamic contrast enhancement and renal perfusion anomalies was evaluated in seven patients, who also underwent renal scintigraphy in baseline conditions. The basal renograms obtained from MAG-3 scintigraphy (mercapto acetyl triglycine, MAG3-S) and from Gd-DOTA-enhanced turboFLASH MRI were compared. After hydration, the protocol used consisted in breath-hold coronal turboFLASH acquisitions after IV bolus of Gd-DOTA (4 s every 20 s during 10 min) for MRI, and IV bolus of 370 MBq of 99mTc-MAG3 followed by 60 frames of 1 s and then 120 frames of 10 s for MAG3-S. Relative renal functions were computed for both methods by calculation of the integral of the uptake phase between the first and the second minute. Renograms exhibited 10 normal and 4 ischemic kidneys. There was a close correlation between the contrast enhancement of MRI and isotopic uptake in normal and ischemic kidneys. Global renograms of MRI correlated with MAG3-S (r = .82, p < .001) with similar curve shape and time to peak. Relative renal function of the right and left kidney were closely correlated in all patients (r = .98, p < .001), although there was a tendency for MR to overestimate MAG3-S evaluation in kidneys with severe basal dysfunction. Enhanced turboFLASH provides noninvasive assessment of renal perfusion in patients with renovascular disease. Accurate renograms are obtained with dynamic-enhanced MRI, but the relative renal function seems to be overestimated in low values of ischemic kidneys, and needs further comparative evaluation.

journal_name

Magn Reson Imaging

authors

Laissy JP,Faraggi M,Lebtahi R,Soyer P,Brillet G,Méry JP,Menu Y,Le Guludec D

doi

10.1016/0730-725x(94)92534-8

subject

Has Abstract

pub_date

1994-01-01 00:00:00

pages

413-9

issue

3

eissn

0730-725X

issn

1873-5894

pii

0730-725X(94)92534-8

journal_volume

12

pub_type

杂志文章
  • MR angiography of meningioma.

    abstract::The clinical evaluation of three-dimensional time-of-flight MR angiography was prospectively performed in 16 patients with intracranial meningioma. MR angiographic techniques used in this study both with and without gadopentetate dimeglumine made it possible to demonstrate the topographic relationship between the tumo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90466-q

    authors: Kadota T,Kuriyama K,Inoue E,Fujita M,Nakagawa H,Kuroda C

    更新日期:1993-01-01 00:00:00

  • Real-time animal functional magnetic resonance imaging and its application to neuropharmacological studies.

    abstract::In pharmacological magnetic resonance imaging (phMRI) with anesthetized animals, there is usually only a single time window to observe the dynamic signal change to an acute drug administration since subsequent drug injections are likely to result in altered response properties (e.g., tolerance). Unlike the block-desig...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.02.020

    authors: Lu H,Yang S,Zuo Y,Demny S,Stein EA,Yang Y

    更新日期:2008-11-01 00:00:00

  • Reproducibility of MRI-derived measurements of right ventricular volumes and myocardial mass.

    abstract::Magnetic resonance (MR) imaging has been shown to provide accurate measurements of right ventricular (RV) volumes and myocardial mass. The purpose of this study was to evaluate the reproducibility of MR imaging, which in clinical practice may be as important as its absolute accuracy. The reproducibility of MR imaging ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)00076-f

    authors: Pattynama PM,Lamb HJ,Van der Velde EA,Van der Geest RJ,Van der Wall EE,De Roos A

    更新日期:1995-01-01 00:00:00

  • Diffusion of water in industrial cement and concrete.

    abstract::We propose a deuterium diffusion tracer approach to measure diffusion coefficient in the case of very short NMR relaxation times, too short for NMR pulsed field gradient sequences (T1 or T2 below 1 ms). We also treat the case of porous media containing metallic fibers (such as reinforced concrete) strongly disturbing ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.09.010

    authors: Fleury M,Berthe G,Chevalier T

    更新日期:2019-02-01 00:00:00

  • Correlations and dissociations between BOLD signal and P300 amplitude in an auditory oddball task: a parametric approach to combining fMRI and ERP.

    abstract::A parametric method is proposed to examine the relationship between neuronal activity, measured with event related potentials (ERPs), and the hemodynamic response, observed with functional magnetic resonance imaging (fMRI), during an auditory oddball paradigm. After verifying that the amplitude of the evoked response ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00496-4

    authors: Horovitz SG,Skudlarski P,Gore JC

    更新日期:2002-05-01 00:00:00

  • Analysis of microporosity and setting of reactive powder concrete by proton nuclear relaxation.

    abstract::The proton spin-lattice relaxation measured at several frequencies leads to a resolved distribution of four Tli for reactive powder concrete (RPC). The typical Tli frequency dependences are quantitatively interpreted by a biphasic fast exchange model and a proton nuclear relaxation of hydrated paramagnetic ions at the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00063-0

    authors: Philippot S,Korb JP,Petit D,Zanni H

    更新日期:1998-06-01 00:00:00

  • SSFP fMRI at 3 tesla: Efficiency of polar acquisition-reconstruction technique.

    abstract::SSFP-based fMRI techniques, known for their high specificity and low geometrical distortion, look promising for high-resolution brain mapping. Nevertheless, they suffer from lack of speed and sensitivity, leading them to be exploited mostly in high-field scanners. Radial acquisition can help with these inefficiencies ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.09.005

    authors: Malekian V,Rastegar F,Shafieizargar B,Nasiraei-Moghaddam A

    更新日期:2020-12-01 00:00:00

  • Multispectral analysis of bone lesions in the hands of patients with rheumatoid arthritis.

    abstract::Quantitative measures of rheumatoid arthritis (RA) disease progression can provide valuable tools for evaluation of new treatments during clinical trials. In this study, a novel multispectral (MS) MRI analysis method is presented to quantify changes in bone lesion volume (DeltaBLV) in the hands of RA patients. Image r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.013

    authors: Carano RA,Lynch JA,Redei J,Ostrowitzki S,Miaux Y,Zaim S,White DL,Peterfy CG,Genant HK

    更新日期:2004-05-01 00:00:00

  • Preliminary evaluation of accelerated microscopic diffusional kurtosis imaging (μDKI) in a rodent model of epilepsy.

    abstract:PURPOSE:Our study aimed to develop accelerated microscopic diffusional kurtosis imaging (μDKI) and preliminarily evaluated it in a rodent model of chronic epilepsy. METHODS:We investigated two μDKI acceleration schemes of reduced sampling density and angular range in a phantom and wild-type rats, and further tested μD...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.10.009

    authors: Ji Y,Lu D,Wu L,Qiu B,Song YQ,Sun PZ

    更新日期:2019-02-01 00:00:00

  • Evaluation of pancreatic exocrine insufficiency by cine-dynamic MRCP using spatially selective inversion-recovery (IR) pulse: Correlation with severity of chronic pancreatitis based on morphological changes of pancreatic duct.

    abstract:PURPOSE:To evaluate the correlation between the pancreatic exocrine insufficiency estimated by cine-dynamic MRCP using spatially selective IR pulse and the severity stages (modified Cambridge classification) based on morphological changes of the pancreatic duct in patients with suspected chronic pancreatitis. MATERIAL...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.12.007

    authors: Yasokawa K,Ito K,Kanki A,Yamamoto A,Torigoe T,Sato T,Tamada T

    更新日期:2018-05-01 00:00:00

  • Evaluation of a contraceptive device with MR imaging.

    abstract::The purpose of this investigation is to evaluate the positioning and to confirm the volume concept of the Lea's Shield diaphragm utilizing MR imaging. We evaluated the device in two women, one nulliparous and one multiparous. We were able to comprehensively evaluate the device in both patients and answer all questions...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00385-x

    authors: Maldjian C,Pelosi MA 2nd,Pelosi MA 3rd,Adam R

    更新日期:2001-06-01 00:00:00

  • Voxelwise analysis of diffusion MRI of cervical spinal cord using tract-based spatial statistics.

    abstract::Robust voxelwise analysis using tract-based spatial statistics (TBSS) together with permutation statistical method is standardly used in analyzing diffusion tensor imaging (DTI) of brain. A similar analytical method could be useful when studying DTI of cervical spinal cord. Based on anatomical data of sixty-four healt...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.07.008

    authors: Dostál M,Keřkovský M,Staffa E,Bednařík J,Šprláková-Puková A,Mechl M

    更新日期:2020-11-01 00:00:00

  • Self-navigated 3D whole-heart MRA for non-enhanced surveillance of thoracic aortic dilation: A comparison to CTA.

    abstract:PURPOSE:To prospectively compare image quality and reliability of a non-contrast, self-navigated 3D whole-heart magnetic resonance angiography (MRA) sequence with contrast-enhanced computed tomography angiography (CTA) for sizing of thoracic aortic aneurysm (TAA). METHODS:Self-navigated 3D whole-heart 1.5 T MRA was pe...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.12.003

    authors: Poskaite P,Pamminger M,Kranewitter C,Kremser C,Reindl M,Reiter G,Piccini D,Dumfarth J,Henninger B,Tiller C,Holzknecht M,Reinstadler SJ,Klug G,Metzler B,Mayr A

    更新日期:2021-02-01 00:00:00

  • Noninvasive evaluation of radiation-enhanced glioma cells invasiveness by ultra-high-field (1)H-MRS in vitro.

    abstract:INTRODUCTION:Glioma is the most common type of the primary CNS tumor. Radiotherapy is an important treatment measure after surgery. However, its highly invasive character is the main reason of postoperative recurrence. The aim of the study was to probe the correlation between the invasion ability and the metabolite cha...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.05.009

    authors: Xu YJ,Cui Y,Li HX,Shi WQ,Li FY,Wang JZ,Zeng QS

    更新日期:2016-10-01 00:00:00

  • Three-dimensional magnetic resonance imaging after ultrasonography for assessment of fetal gastroschisis.

    abstract::A 24-year-old woman (Gravida I, Para I) at estimated 32 weeks of pregnancy was referred to our department for evaluation of a suspected fetal gastroschisis. Ultrasound scan revealed multiple loops of dilated bowel outside the fetal abdomen and absence of membrane surrounding the herniated loops of the intestines. Thre...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.006

    authors: Sasaki Y,Miyamoto T,Hidaka Y,Satoh H,Takuma N,Sengoku K,Sugimori H,Inaoka T,Aburano T

    更新日期:2006-02-01 00:00:00

  • Three dimensional texture analysis in MRI: a preliminary evaluation in gliomas.

    abstract::The discrimination of tumor boundaries from normal tissue, as well as the evaluation of tissue heterogeneity and tumor grading often continue to pose a challenge in MRI. Although yielding promising results in various fields of medical imaging, two- dimensional (2D) texture analysis in MRI has, until now, demonstrated ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00201-7

    authors: Mahmoud-Ghoneim D,Toussaint G,Constans JM,de Certaines JD

    更新日期:2003-11-01 00:00:00

  • Drug monitoring of 5-fluorouracil: in vivo 19F NMR study during 5-FU chemotherapy in patients with metastases of colorectal adenocarcinoma.

    abstract::The metabolism of 5-fluorouracil (5-FU) is complex and the reason for the low response rate of tumor patients to 5-FU is currently unknown. The aim of this study was to evaluate whether spectral parameters obtained noninvasively by in vivo 19F nuclear magnetic resonance (NMR) spectroscopy can be used to assess individ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92544-5

    authors: Schlemmer HP,Bachert P,Semmler W,Hohenberger P,Schlag P,Lorenz WJ,van Kaick G

    更新日期:1994-01-01 00:00:00

  • A simple method for MR elastography: a gradient-echo type multi-echo sequence.

    abstract::To demonstrate the feasibility of a novel MR elastography (MRE) technique based on a conventional gradient-echo type multi-echo MR sequence which does not need additional bipolar magnetic field gradients (motion encoding gradient: MEG), yet is sensitive to vibration. In a gradient-echo type multi-echo MR sequence, sev...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.10.002

    authors: Numano T,Mizuhara K,Hata J,Washio T,Homma K

    更新日期:2015-01-01 00:00:00

  • An MRI perfusion model incorporating nonequilibrium exchange between vascular and extravascular compartments.

    abstract::A model of MRI signal intensity which is a function of perfusion is developed based upon the assumption that biological tissue can be represented by a blood and tissue compartment. The longitudinal magnetization is derived from the Bloch equations which are modified to model the magnetization in both the blood and tis...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90095-4

    authors: Gullberg GT,Ma X,Parker DL,Roy DN

    更新日期:1991-01-01 00:00:00

  • Application of spherical harmonics derived space rotation invariant indices to the analysis of multiple sclerosis lesions' geometry by MRI.

    abstract::In the longitudinal study of multiple sclerosis (MS) lesions, varying position of the patient inside the MRI scanner is one of the major sources of assessment errors. We propose to use analytical indices that are invariant to spatial orientation to describe the lesions, rather than focus on patient repositioning or im...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.053

    authors: Goldberg-Zimring D,Achiron A,Warfield SK,Guttmann CR,Azhari H

    更新日期:2004-07-01 00:00:00

  • An alternative viewpoint of the similarities and differences of SVD and FT deconvolution algorithms used for quantitative MR perfusion studies.

    abstract::Quantitative cerebral blood flow (CBF) values can be determined from residue function estimates obtained from magnetic resonance dynamic susceptibility contrast (DSC) perfusion studies using a variety of deconvolution approaches. However, there are significant differences between the CBF estimates obtained, difference...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.12.001

    authors: Salluzzi M,Frayne R,Smith MR

    更新日期:2005-04-01 00:00:00

  • Factors influencing contrast in fast spin-echo MR imaging.

    abstract::Multi-echo pulse sequences for producing T2-weighted images in much reduced imaging times have recently been developed for routine clinical use. A number of recent articles have described the contrast obtained with fast spin-echo (FSE) sequences and have generally indicated that they depict tissues very similarly to c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(92)90001-g

    authors: Constable RT,Anderson AW,Zhong J,Gore JC

    更新日期:1992-01-01 00:00:00

  • Magnetization transfer of water T(2) relaxation components in human brain: implications for T(2)-based segmentation of spectroscopic volumes.

    abstract::Biexponential T(2) relaxation of the localized water signal can be used for segmentation of spectroscopic volumes. To assess the specificity of the components an iterative relaxation measurement of the localized water signal (STEAM, 12 echo times, geometric spacing from 30 ms to 2000 ms) was combined with magnetizatio...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00396-4

    authors: Helms G,Piringer A

    更新日期:2001-07-01 00:00:00

  • Differentiation of hepatomas from nonhepatomatous masses: use of MnDPDP-enhanced MR images.

    abstract::Manganese (II) N,N'-dipyridoxylethylenediamine-N,N' diacetate 5,5'-bis(phosphate) (MnDPDP) is a hepatobiliary agent that is incorporated into the hepatocyte. We retrospectively reviewed our experience with 39 focal liver lesions in 20 patients studies with MnDPDP-enhanced hepatic magnetic resonance (MR) imaging to det...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92354-x

    authors: Liou J,Lee JK,Borrello JA,Brown JJ

    更新日期:1994-01-01 00:00:00

  • Reducing SAR in parallel excitation using variable-density spirals: a simulation-based study.

    abstract::Parallel excitation using multiple transmit channels has emerged as an effective method to shorten multidimensional spatially selective radiofrequency (RF) pulses, which have a number of important applications, including B1 field inhomogeneity correction in high-field MRI. The specific absorption rate (SAR) is a prima...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.02.003

    authors: Liu Y,Feng K,McDougall MP,Wright SM,Ji J

    更新日期:2008-10-01 00:00:00

  • Fast and exact flow measurements with the fast Fourier flow technique.

    abstract::The fast Fourier flow technique offers a convenient way for extremely exact flow measurements. In combination with ECG gating, arterial flow can be studied. The total acquisition time for a single measurement is about 10 s, an ECG-gated cine sequence can be acquired in about 4 min. Fast Fourier flow can, therefore, be...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90473-0

    authors: Hennig J,Mueri M,Brunner P,Friedburg H

    更新日期:1988-07-01 00:00:00

  • Lateral ventricular cerebrospinal fluid diffusivity as a potential neuroimaging marker of brain temperature in multiple sclerosis: a hypothesis and implications.

    abstract::In this retrospective study we tested the hypothesis that the net effect of impaired electrical conduction and therefore increased heat dissipation in multiple sclerosis (MS) results in elevated lateral ventricular (LV) cerebrospinal fluid (CSF) diffusivity as a measure of brain temperature estimated in vivo using dif...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.11.002

    authors: Hasan KM,Lincoln JA,Nelson FM,Wolinsky JS,Narayana PA

    更新日期:2015-04-01 00:00:00

  • Rapid and recoverable in vivo magnetic resonance imaging of the adult zebrafish at 7T.

    abstract::Increasing scientific interest in the zebrafish as a model organism across a range of biomedical and biological research areas raises the need for the development of in vivo imaging tools appropriate to this subject. Development of the embryonic and early stage forms of the subject can currently be assessed using opti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.10.013

    authors: Merrifield GD,Mullin J,Gallagher L,Tucker C,Jansen MA,Denvir M,Holmes WM

    更新日期:2017-04-01 00:00:00

  • A nonlinear regularization strategy for GRAPPA calibration.

    abstract::A regularization strategy is described for generalized autocalibrating partially parallel acquisition (GRAPPA) that allows successful calibration using a small number of autocalibration signals (ACS). The approach requires certain nonlinear relationships between the GRAPPA coefficients to be satisfied, which increases...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.05.005

    authors: Bydder M,Jung Y

    更新日期:2009-01-01 00:00:00

  • Non-Gaussian diffusion MRI assessment of brain microstructure in mild cognitive impairment and Alzheimer's disease.

    abstract::We report the first application of a novel diffusion-based MRI method, called diffusional kurtosis imaging (DKI), to investigate changes in brain tissue microstructure in patients with mild cognitive impairment (MCI) and AD and in cognitively intact controls. The subject groups were characterized and compared in terms...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.02.008

    authors: Falangola MF,Jensen JH,Tabesh A,Hu C,Deardorff RL,Babb JS,Ferris S,Helpern JA

    更新日期:2013-07-01 00:00:00