Accurate and sensitive measurements of magnetic susceptibility using echo planar imaging.

Abstract:

:Susceptibility differences are common causes for artifacts in magnetic resonance (MR); therefore, it is important to choose phantom materials in a way that these artifacts are kept at a minimum. In this study, a previously proposed MR imaging (MRI) method [Beuf O, Briguet A, Lissac M, Davis R. Magnetic resonance imaging for the determination of magnetic susceptibility of materials. J Magn Reson 1996; Series B(112):111-118] was improved to facilitate sensitive in-house measurements of different phantom materials so that such artifacts can more easily be minimized. Using standard MRI protocols and distilled water as reference, we measured magnetic volume susceptibility differences with a clinical MR system. Two imaging techniques, echo planar imaging (EPI) and spin echo, were compared using liquid samples whose susceptibilities were verified by MR spectroscopy. The EPI sequence has a very narrow bandwidth in the phase-encoding direction, which gives an increased sensitivity to magnetic field inhomogeneities. All MRI measurements were evaluated in two ways: (1) manual image analysis and (2) model fitting. The narrow bandwidth of the EPI made it possible to detect very small susceptibility differences (equivalent susceptibility difference, Deltachi(e)> or =0.02 ppm), and even plastics could be measured. Model fitting yielded high accuracy and high sensitivity and was less sensitive to other image artifacts as compared with manual image analysis.

journal_name

Magn Reson Imaging

authors

Carlsson A,Starck G,Ljungberg M,Ekholm S,Forssell-Aronsson E

doi

10.1016/j.mri.2006.07.005

subject

Has Abstract

pub_date

2006-11-01 00:00:00

pages

1179-85

issue

9

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(06)00207-4

journal_volume

24

pub_type

杂志文章
  • A flexible 9-channel coil array for fast 3D MR thermometry in MR-guided high-intensity focused ultrasound (HIFU) studies on rabbits at 3 T.

    abstract::Signal-to-noise ratio (SNR) is a critical factor in MR-guided high-intensity focused ultrasound (HIFU) for local heating, which can affect the accuracy of temperature measurement. In order to achieve high SNR and higher temporal resolution, dedicated coil arrays for MR-guided HIFU applications need to be developed. In...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.10.008

    authors: Chen Q,Li Y,Jiang R,Zou C,Tie C,Wen J,Yang X,Zhang X,Liu X,Zheng H

    更新日期:2020-01-01 00:00:00

  • Analyzing spatially and temporally visualized formation behavior of methane hydrate in unconsolidated porous media.

    abstract::An understanding of the nucleation and growth mechanism of methane hydrate in porous space is essential for exploitation and application of hydrates, but the mechanism is yet to be clarified. Magnetic resonance imaging (MRI) was employed to visually analyze the spatial and temporal formation behavior of methane hydrat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.06.005

    authors: Zhang L,Sun L,Sun M,Lv X,Dong H,Miao Y,Yang L,Song Y,Zhao J

    更新日期:2019-09-01 00:00:00

  • Chemical exchange saturation transfer MR imaging of articular cartilage glycosaminoglycans at 3 T: Accuracy of B0 Field Inhomogeneity corrections with gradient echo method.

    abstract::Glycosaminoglycan Chemical Exchange Saturation Transfer (gagCEST) is an important molecular MRI methodology developed to assess changes in cartilage GAG concentrations. The correction for B0 field inhomogeneity is technically crucial in gagCEST imaging. This study evaluates the accuracy of the B0 estimation determined...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.07.009

    authors: Wei W,Jia G,Flanigan D,Zhou J,Knopp MV

    更新日期:2014-01-01 00:00:00

  • Artifacts in chemical shift selective imaging.

    abstract::The role of susceptibility effects in the production of artifacts in chemical shift images generated by the selective excitation technique is discussed. The effects are demonstrated in images of phantom samples of agarose gels containing small air bubbles. The artifacts can lead to erroneous interpretations, in which ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90022-r

    authors: Pope JM,Walker RR,Kron T

    更新日期:1992-01-01 00:00:00

  • Diagnosis of discoid lateral meniscus of the knee on MR imaging.

    abstract::To establish the quantitative MR diagnostic criteria for discoid lateral meniscus, MR imaging of 60 knees with arthroscopically confirmed discoid lateral menisci and 134 knees with semilunar lateral menisci were analyzed. Following four quantitative parameters were measured. (1) Meniscal width (MW): The minimum menisc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00473-3

    authors: Samoto N,Kozuma M,Tokuhisa T,Kobayashi K

    更新日期:2002-01-01 00:00:00

  • SmartPhantom--an fMRI simulator.

    abstract::Many informatics tools have emerged to process the voluminous and complex data generated by functional magnetic resonance imaging (fMRI). The interpretation of fMRI exams is largely determined by these tools. However, their performance is hard to evaluate because there is no independent means of calibration. A novel f...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.012

    authors: Cheng H,Zhao Q,Duensing GR,Edelstein WA,Spencer D,Browne N,Saylor C,Limkeman M

    更新日期:2006-04-01 00:00:00

  • High-resolution magnetic resonance flow imaging in a model of porous bone-implant interface.

    abstract:PURPOSE:To evaluate the application of high-resolution MRI methodology for characterizing the fluid velocity field and evaluate fluid shear field within a simplified in vitro model of a bone-implant interface. MATERIALS AND METHODS:The study used a specific micromotion canine bone implant that has been used for over a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.11.001

    authors: Conroy MJ,Pédrono A,Bechtold JE,Søballe K,Ambard D,Swider P

    更新日期:2006-06-01 00:00:00

  • Effect of slice orientation on reproducibility of fMRI motor activation at 3 Tesla.

    abstract::The effect of slice orientation on reproducibility and sensitivity of 3T fMRI activation using a motor task has been investigated in six normal volunteers. Four slice orientations were used; axial, oblique axial, coronal and sagittal. We applied analysis of variance (ANOVA) to suprathreshold voxel statistics to quanti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00399-x

    authors: Gustard S,Fadili J,Williams EJ,Hall LD,Carpenter TA,Brett M,Bullmore ET

    更新日期:2001-12-01 00:00:00

  • "Molecular" MR imaging at high fields.

    abstract::Magnetic resonance imaging (MRI) and spectroscopy (MRS) have contributed considerably to clinical radiology, and a variety of MR techniques have been developed to evaluate pathological processes as well as normal tissue biology at the cellular and molecular level. However, in comparison to nuclear imaging, MRI has rel...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.12.008

    authors: Gore JC,Zu Z,Wang P,Li H,Xu J,Dortch R,Gochberg DF

    更新日期:2017-05-01 00:00:00

  • Surface magnetic relaxation in cement pastes.

    abstract::Surface magnetic relaxation in porous media is usually attributed to hindered rotation or to paramagnetic impurities on the surface. In cement pastes, however, it seems reasonable to attribute surface relaxation to dipole interactions in water adsorbed as water of hydration on grain surfaces. The rate limiting factor ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91517-2

    authors: Mendelson KS,Halperin WP,Jehng JY,Song YQ

    更新日期:1994-01-01 00:00:00

  • Diffusion tensor imaging of native and degenerated human articular cartilage.

    abstract::Diffusion tensor imaging (DTI) is potentially sensitive to collagen degeneration in cartilage. In this study, DTI was measured on human cartilage samples with interventions of trypsin and collagenase. The measured preferred diffusion direction was consistent with the zonal structure of collagen network. The glycosamin...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.10.015

    authors: Deng X,Farley M,Nieminen MT,Gray M,Burstein D

    更新日期:2007-02-01 00:00:00

  • Towards quantitative evaluation of wall shear stress from 4D flow imaging.

    abstract::Wall shear stress (WSS) is a relevant hemodynamic indicator of the local stress applied on the endothelium surface. More specifically, its spatiotemporal distribution reveals crucial in the evolution of many pathologies such as aneurysm, stenosis, and atherosclerosis. This paper introduces a new solution, called PaLMA...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.08.017

    authors: Levilly S,Castagna M,Idier J,Bonnefoy F,Le Touzé D,Moussaoui S,Paul-Gilloteaux P,Serfaty JM

    更新日期:2020-12-01 00:00:00

  • In vivo animal tests of an artifact-free contrast agent for gastrointestinal MRI.

    abstract::A variety of shortcomings are associated with most currently used gastrointestinal contrast agents for magnetic resonance imaging (MRI). Artifacts resulting from peristalsis and other motions in the abdominal region are produced by many positive contrast agents (which increase signal intensity). Although this is not a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00020-9

    authors: Briggs RW,Wu Z,Mladinich CR,Stoupis C,Gauger J,Liebig T,Ros PR,Ballinger JR,Kubilis P

    更新日期:1997-01-01 00:00:00

  • MRI findings in pulmonary sarcoidosis.

    abstract::Postero-anterior radiographs and magnetic resonance imaging (MRI) of the chest were performed in nine biopsy proven cases of sarcoidosis. MRI was more sensitive than a postero-anterior chest roentgenogram in detecting hilar and mediastinal adenopathy but less informative in detecting pleural and parenchymal disease. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90131-2

    authors: Craig DA,Colletti PM,Ratto D,Gordonson JS,Raval JK,Sharma OP

    更新日期:1988-09-01 00:00:00

  • Trajectory correction for free-breathing radial cine MRI.

    abstract::Radial acquisitions can suffer from trajectory errors leading to reduced image quality. Here we present a new method of trajectory correction that uses all spokes of a radial acquisition and compare it to an existing method that uses a two-spoke pre-scan calibration. For both methods, estimates of the necessary shifts...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.04.006

    authors: Buonincontri G,Methner C,Krieg T,Carpenter TA,Sawiak SJ

    更新日期:2014-09-01 00:00:00

  • In vivo nuclear magnetic resonance imaging and spectroscopy of aquatic organisms.

    abstract::NMR imaging and localized 1H spectroscopy of a variety of aquatic organisms in vivo is described for the first time. The practical consideration of life support, water volume, salinity, and anesthesia are discussed and solutions presented. Such animal studies shape our understanding of physiology, biochemistry, and bi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90253-x

    authors: Blackband SJ,Stoskopf MK

    更新日期:1990-01-01 00:00:00

  • Flexible, phase-matched, linear receive arrays for high-field MRI in monkeys.

    abstract::High signal-to-noise ratios (SNR) are essential for high-resolution anatomical and functional MRI. Phased arrays are advantageous for this but have the drawback that they often have inflexible and bulky configurations. Particularly in experiments where functional MRI is combined with simultaneous electrophysiology, sp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.03.026

    authors: Goense J,Logothetis NK,Merkle H

    更新日期:2010-10-01 00:00:00

  • MR imaging of late onset orbital rhabdomyosarcoma with intracranial extension.

    abstract::Today, patients with alveolar rhabdomyosarcoma have a favorable prognosis with a survival rate of more than 80%, due to modern radiotherapy. However, those patients with secondary meningeal involvement are still afflicted with a mortality rate of 90% unless a different therapeutic approach is taken. We report a case o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90035-c

    authors: Judmaier W,Birbamer G,Buchberger W,Mihatsch T,Lener M,Felber S

    更新日期:1993-01-01 00:00:00

  • Voxel- and atlas-based analysis of diffusion tensor imaging may reveal focal axonal injuries in mild traumatic brain injury -- comparison with diffuse axonal injury.

    abstract:BACKGROUND:The diagnosis and management of mild traumatic brain injury (MTBI) continue to be subjects of debate, with varying opinions regarding the extent to which tissue-based impairments versus the impacts of other stressors cause ongoing disability. Detecting areas of the brain with abnormalities that can explain s...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.12.018

    authors: Kasahara K,Hashimoto K,Abo M,Senoo A

    更新日期:2012-05-01 00:00:00

  • Correction of partial volume inaccuracies in quantitative phase contrast MR angiography.

    abstract::The phase difference method of phase contrast MR angiography provides a means of measuring the average velocity in each voxel of an MR scan. When static tissue is present in a voxel containing flow, the measured velocity is not the average velocity of the flow alone, but is lower due to the partial volume effect of th...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91245-r

    authors: Hamilton CA

    更新日期:1994-01-01 00:00:00

  • In vivo magnetic resonance study of the histochemistry of coconut (Cocos nucifera).

    abstract::Magnetic resonance imaging (MRI) and localized proton MR spectroscopy (MRS) techniques have been applied for studying different maturation processes in the histochemistry of coconut (Cocos nucifera). Images of the tender and mature coconut are characterized by protons of the aqueous solution present in the cavity and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00033-d

    authors: Jagannathan NR,Govindaraju V,Raghunathan P

    更新日期:1995-01-01 00:00:00

  • Analysis of machine-dependent and object-induced geometric distortion in 2DFT MR imaging.

    abstract::Geometric distortion in MR imaging predominantly arises from the inhomogeneity of the static field and the nonlinearity of the gradients. It is the purpose of this paper to analyse the object and machine related contributions to geometric distortion in order to determine which corrections are necessary for attaining a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90011-n

    authors: Bakker CJ,Moerland MA,Bhagwandien R,Beersma R

    更新日期:1992-01-01 00:00:00

  • Biliary cystadenocarcinoma: seven year follow-up and the role of MRI and MRCP.

    abstract::Biliary cystadenomas and their malignant counterparts, biliary cystadenocarcinomas, are rare cystic tumors that arise from hepatobiliary epithelium. Ultrasound (US) and computed tomography (CT) are the initial imaging modalities used for the evaluation of biliary cystic tumors, but are not specific. MRI and MRCP, beca...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00453-2

    authors: Williams DM,Vitellas KM,Sheafor D

    更新日期:2001-11-01 00:00:00

  • Functional MR imaging in the awake monkey: effects of motion on dynamic off-resonance and processing strategies.

    abstract::Functional MR imaging of the alert, behaving monkey is being used more and more often to detect activation patterns and guide electrophysiological research investigating the neural basis of behavior. Several labs have reported fMRI data from the awake monkey, but none of them has studied and systematically corrected t...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.03.002

    authors: Pfeuffer J,Shmuel A,Keliris GA,Steudel T,Merkle H,Logothetis NK

    更新日期:2007-07-01 00:00:00

  • Multispectral analysis of bone lesions in the hands of patients with rheumatoid arthritis.

    abstract::Quantitative measures of rheumatoid arthritis (RA) disease progression can provide valuable tools for evaluation of new treatments during clinical trials. In this study, a novel multispectral (MS) MRI analysis method is presented to quantify changes in bone lesion volume (DeltaBLV) in the hands of RA patients. Image r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.013

    authors: Carano RA,Lynch JA,Redei J,Ostrowitzki S,Miaux Y,Zaim S,White DL,Peterfy CG,Genant HK

    更新日期:2004-05-01 00:00:00

  • Evaluation of a contraceptive device with MR imaging.

    abstract::The purpose of this investigation is to evaluate the positioning and to confirm the volume concept of the Lea's Shield diaphragm utilizing MR imaging. We evaluated the device in two women, one nulliparous and one multiparous. We were able to comprehensively evaluate the device in both patients and answer all questions...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00385-x

    authors: Maldjian C,Pelosi MA 2nd,Pelosi MA 3rd,Adam R

    更新日期:2001-06-01 00:00:00

  • Intracranial vascular feature changes in time of flight MR angiography in patients undergoing carotid revascularization surgery.

    abstract:PURPOSE:To characterize the intracranial vascular features extracted from time of flight (TOF) images and their changes from baseline to follow-up in patients undergoing carotid revascularization, using arterial spin labeling (ASL) cerebral blood flow (CBF) measurement as a reference. METHODS:In this retrospective stu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.10.004

    authors: Chen Z,Chen L,Shirakawa M,Liu W,Ortega D,Chen J,Balu N,Trouard T,Hatsukami TS,Zhou W,Yuan C

    更新日期:2021-01-01 00:00:00

  • A simple analytic method for estimating T2 in the knee from DESS.

    abstract:PURPOSE:To introduce a simple analytical formula for estimating T2 from a single Double-Echo in Steady-State (DESS) scan. METHODS:Extended Phase Graph (EPG) modeling was used to develop a straightforward linear approximation of the relationship between the two DESS signals, enabling accurate T2 estimation from one DES...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.12.018

    authors: Sveinsson B,Chaudhari AS,Gold GE,Hargreaves BA

    更新日期:2017-05-01 00:00:00

  • Fast acceleration of ASL-based time-resolved magnetic resonance angiography by acquisition of control and labeled images in the same shot (fast ACTRESS): An optimization study.

    abstract:PURPOSE:To establish an optimized sequence design for fast acceleration of arterial spin labeling (ASL)-based time-resolved magnetic resonance angiography (MRA) by acquisition of control and labeled images in the same shot (fast ACTRESS) and a scan time of <1min, for the evaluation of intracranial vessels. MATERIALS A...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.07.026

    authors: Sugimori H,Fujima N,Suzuki Y,Hamaguchi H,Ishizaka K,Kudo K

    更新日期:2017-11-01 00:00:00

  • Rapid acquisition strategy for functional T1ρ mapping of the brain.

    abstract::Functional T1ρ mapping has been proposed as a method to assess pH and metabolism dynamics in the brain with high spatial and temporal resolution. The purpose of this work is to describe and evaluate a variant of the spin-locked echo-planar imaging sequence for functional T1ρ mapping at 3T. The proposed sequence rapidl...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.07.010

    authors: Johnson CP,Heo HY,Thedens DR,Wemmie JA,Magnotta VA

    更新日期:2014-11-01 00:00:00