A simple analytic method for estimating T2 in the knee from DESS.

Abstract:

PURPOSE:To introduce a simple analytical formula for estimating T2 from a single Double-Echo in Steady-State (DESS) scan. METHODS:Extended Phase Graph (EPG) modeling was used to develop a straightforward linear approximation of the relationship between the two DESS signals, enabling accurate T2 estimation from one DESS scan. Simulations were performed to demonstrate cancellation of different echo pathways to validate this simple model. The resulting analytic formula was compared to previous methods for T2 estimation using DESS and fast spin-echo scans in agar phantoms and knee cartilage in three volunteers and three patients. The DESS approach allows 3D (256×256×44) T2-mapping with fat suppression in scan times of 3-4min. RESULTS:The simulations demonstrated that the model approximates the true signal very well. If the T1 is within 20% of the assumed T1, the T2 estimation error was shown to be less than 5% for typical scans. The inherent residual error in the model was demonstrated to be small both due to signal decay and opposing signal contributions. The estimated T2 from the linear relationship agrees well with reference scans, both for the phantoms and in vivo. The method resulted in less underestimation of T2 than previous single-scan approaches, with processing times 60 times faster than using a numerical fit. CONCLUSION:A simplified relationship between the two DESS signals allows for rapid 3D T2 quantification with DESS that is accurate, yet also simple. The simplicity of the method allows for immediate T2 estimation in cartilage during the MRI examination.

journal_name

Magn Reson Imaging

authors

Sveinsson B,Chaudhari AS,Gold GE,Hargreaves BA

doi

10.1016/j.mri.2016.12.018

subject

Has Abstract

pub_date

2017-05-01 00:00:00

pages

63-70

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(16)30265-X

journal_volume

38

pub_type

杂志文章
  • Breath-hold T2-weighted sequences of the liver: a comparison of four techniques at 1.0 and 1.5 T.

    abstract::T2-weighted images are considered the most sensitive for lesion detection at high field; however, long imaging time is problematic. Accordingly, the authors compared four breath-hold T2 or T2* weighted sequences comprising T2*-weighted FLASH, T2*-weighted PSIF, T2-weighted rapid spin echo (RASE), and T2-weighted Turbo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90371-6

    authors: Simm FC,Semelka RC,Recht M,Deimling M,Lenz G,Laub GA

    更新日期:1992-01-01 00:00:00

  • Evaluation of water content by spatially resolved transverse relaxation times of human articular cartilage.

    abstract::Non-invasive assessment of cartilage properties, specifically water content, could prove helpful in the diagnosis of early degenerative joint diseases. Transverse relaxation times T(2) of human articular cartilage (34 cartilage slices of three donors) were measured on a pixel-by-pixel basis in a clinical whole body MR...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00144-7

    authors: Lüsse S,Claassen H,Gehrke T,Hassenpflug J,Schünke M,Heller M,Glüer CC

    更新日期:2000-05-01 00:00:00

  • Cortical morphologic changes in recent-onset, drug-naïve idiopathic generalized epilepsy.

    abstract:PURPOSE:Only a few studies have investigated the brain morphology abnormalities in structural MRI in patients with drug-naïve idiopathic generalized epilepsy (IGE) and mainly focused on brain volume changes. In the present study, we aimed to investigate the changes in three morphologic measurement differences including...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.05.035

    authors: Deng DM,Chen LZ,Li YW,Long R,Tang GC,Han FG,Diao XM,Chen HL,Long ZL,Qiu LH

    更新日期:2019-09-01 00:00:00

  • Synovial sarcoma: MR imaging.

    abstract::Ten patients with biopsy-proved synovial sarcoma were evaluated by magnetic resonance (MR) imaging on a 1.5-T unit. The lesions showed intermediate signal intensity on T1-weighted images and heterogeneous high signal intensity on T2-weighted images. Tumors were well-demarcated from normal tissues. Additional informati...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90706-6

    authors: Mahajan H,Lorigan JG,Shirkhoda A

    更新日期:1989-03-01 00:00:00

  • A computer algorithm for the simulation of any nuclear magnetic resonance (NMR) imaging method.

    abstract::More than a dozen Nuclear Magnetic Resonance (NMR) imaging methods have been described using different radio-frequency pulse sequences, magnetic field gradient variations, and data processing. In order to have a theoretical understanding in the most general case, we have conceived a computer program for the simulation...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(84)90065-1

    authors: Bittoun J,Taquin J,Sauzade M

    更新日期:1984-01-01 00:00:00

  • Non-contrast-enhanced MR angiography in the diagnosis of Budd-Chiari syndrome (BCS) compared with digital subtraction angiography (DSA): Preliminary results.

    abstract::Non-CE MRA techniques (true steady-state free-precession, SSFP) have been used effectively for the selective visualization of the portal venous system and inferior vena cava. Budd-Chiari Syndrome (BCS) encompasses a number of conditions that cause the obstruction of the hepatic outflow tract from the small hepatic vei...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.10.006

    authors: Yang C,Li C,Zeng M,Lu X,Li J,Wang J,Sami MU,Xu K

    更新日期:2017-02-01 00:00:00

  • Assessing the effect of football play on knee articular cartilage using delayed gadolinium-enhanced MRI of cartilage (dGEMRIC).

    abstract::The prevalence of cartilage lesions is much higher in football athletes than in the general population. Delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) has been shown to quantify regional variations of glycosaminoglycan (GAG) concentrations which is an indicator of early cartilage degeneration. The goal of this...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.01.008

    authors: Wei W,Lambach B,Jia G,Flanigan D,Chaudhari AMW,Wei L,Rogers A,Payne J,Siston RA,Knopp MV

    更新日期:2017-06-01 00:00:00

  • Investigating mobility of crude oil adsorbates on mineral surfaces by NMR.

    abstract::We have applied diffusion and relaxation Nuclear Magnetic Resonance experiments to investigate the translational and rotational mobility of adsorbents on quartz and calcite mineral surfaces. On both surfaces it was found that water is the dominant molecule. On the quartz surface the majority of water molecules have a ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.10.002

    authors: Sørgård HN,Totland C,Nerdal W,Seland JG

    更新日期:2019-02-01 00:00:00

  • Two-tensor model-based bootstrapping on classified tensor morphologies: estimation of uncertainty in fiber orientation and probabilistic tractography.

    abstract::In this manuscript, fast and clinically feasible model-based bootstrapping algorithms using a geometrically constrained two-tensor diffusion model are employed for estimating uncertainty in fiber orientation. A Monte-Carlo-based tensor morphology voxel classification algorithm is initially applied using single-tensor ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.07.004

    authors: Ratnarajah N,Simmons A,Bertoni M,Hojjatoleslami A

    更新日期:2013-02-01 00:00:00

  • Quantitative MRI using T1ρ and T2 in human osteoarthritic cartilage specimens: correlation with biochemical measurements and histology.

    abstract:PURPOSE:A direct correlation between T(1ρ), T(2) and quantified proteoglycan and collagen contents in human osteoarthritic cartilage has yet to be documented. We aimed to investigate the orientation effect on T(1ρ) and T(2) values in human osteoarthritic cartilage and to quantify the correlation between T(1ρ), T(2) vs....

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.09.004

    authors: Li X,Cheng J,Lin K,Saadat E,Bolbos RI,Jobke B,Ries MD,Horvai A,Link TM,Majumdar S

    更新日期:2011-04-01 00:00:00

  • Muscle and fat quantification in MRI gradient echo images using a partial volume detection method. Application to the characterization of pig belly tissue.

    abstract::Complete dissection is the current reference method to quantify muscle and fat tissue on pig carcasses. Magnetic resonance imaging (MRI) is an appropriate nondestructive alternative method that can provide reliable and quantitative information on pig carcass composition without losing the spatial information. We have ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.05.001

    authors: Monziols M,Collewet G,Mariette F,Kouba M,Davenel A

    更新日期:2005-07-01 00:00:00

  • 1H-MRS of the macaque monkey primary visual cortex at 7 T: strategies and pitfalls of shimming at the brain surface.

    abstract::Magnetic resonance spectroscopy (MRS) is ideally suited for physiology-neurochemistry experiments with the living brain and particularly for studies on the primary visual cortex (striate cortex or area V1). Yet, the highly convoluted form of the human V1 has thus far prevented the performance of MRS investigations tha...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.03.008

    authors: Juchem C,Logothetis NK,Pfeuffer J

    更新日期:2007-07-01 00:00:00

  • Quantitative longitudinal fluid saturation profiles with a slice-selected CPMG sequence.

    abstract::A technique for obtaining quantitative longitudinal saturation/porosity profiles of rock cores which are longer than the NMR coil has been developed. The slice-selected experiment uses a prefocused pulse in conjunction with a magnetic field gradient for the localization and a CPMG sequence to sample the data. A variet...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91547-4

    authors: Pierens GK,Peyron M,Lucas AJ,Carpenter TA,Hall LD,Potter GF,Stewart RC,Phelps DW

    更新日期:1994-01-01 00:00:00

  • The relaxivity of Gd-EOB-DTPA and Gd-DTPA in liver and kidney of the Wistar rat.

    abstract::The NMR relaxivities of Gd-EOB-DTPA and Gd-DTPA were determined in the kidney and liver of intact male Wistar rats immediately following sacrifice and in vitro in solutions and gels, at 1.5 T using a clinical MR scanner, T1 and T2 values of tissue samples were derived from spin-echo image sequences. Tissue gadolinium ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02097-d

    authors: Shuter B,Tofts PS,Wang SC,Pope JM

    更新日期:1996-01-01 00:00:00

  • Echo-shifted multislice EPI for high-speed fMRI.

    abstract::The advantages of event-related functional Magnetic Resonance Imaging (fMRI) and the increasing use of fMRI in cognitive experiments are both driving the development of techniques that allow images sensitive to the blood oxygen level-dependent effect to be acquired at ever-higher temporal resolution. Here, we present ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.030

    authors: Gibson A,Peters AM,Bowtell R

    更新日期:2006-05-01 00:00:00

  • A data augmentation approach to train fully convolutional networks for left ventricle segmentation.

    abstract::Left ventricle (LV) segmentation plays an important role in the diagnosis of cardiovascular diseases. The cardiac contractile function can be quantified by measuring the segmentation results of LVs. Fully convolutional networks (FCNs) have been proven to be able to segment images. However, a large number of annotated ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.08.004

    authors: Lin A,Wu J,Yang X

    更新日期:2020-02-01 00:00:00

  • Phase contrast and time-of-flight magnetic resonance angiography of the intracerebral arteries at 1.5, 3 and 7 T.

    abstract:PURPOSE:Time-of-flight (ToF) and phase contrast (PC) magnetic resonance angiographies (MRAs) are noninvasive applications to depict the cerebral arteries. Both approaches can image the cerebral vasculature without the administration of intravenous contrast. Therefore, it is used in routine clinical evaluation of cerebr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.10.023

    authors: Stamm AC,Wright CL,Knopp MV,Schmalbrock P,Heverhagen JT

    更新日期:2013-05-01 00:00:00

  • Anisotropic diffusion in etched particle tracks studied by field gradient NMR.

    abstract::Etched particle tracks produced after heavy ion irradiation of polymer foils are used as model systems to test the performance of NMR in a newly developed ultrahigh magnetic field gradient system. The stimulated NMR echo decay of molecules diffusing in the channels, formulated in terms of the self part of the intermed...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91527-x

    authors: Fujara F,Ilyina E,Nienstaedt H,Sillescu H,Spohr R,Trautmann C

    更新日期:1994-01-01 00:00:00

  • Relationship between cancellous bone induced magnetic field and ultrastructure in a rat ovariectomy model.

    abstract::The site-dependent variations in trabecular bone morphology were studied in the rat tibia by magnitude and phase difference three-dimensional nuclear magnetic resonance microscopy and image processing, and the implications of ovariectomy were evaluated. Specimens excised from the proximal tibial metaphysis in ovariect...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00107-1

    authors: Takahashi M,Wehrli FW,Hwang SN,Wehrli SL

    更新日期:2000-01-01 00:00:00

  • In vitro experiments on ICOSA6 4D flow MRI measurement for the quantification of velocity and turbulence parameters.

    abstract:PURPOSE:To perform comprehensive in vitro experiments using six-directional icosahedral flow encoding (ICOSA6) 4D flow magnetic resonance imaging (MRI) under various scan conditions to analyze the robustness of velocity and turbulence quantification. MATERIALS AND METHODS:In vitro flow phantoms with steady flow rates ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.06.020

    authors: Ha H,Park KJ,Dyverfeldt P,Ebbers T,Yang DH

    更新日期:2020-10-01 00:00:00

  • Short T2 contrast with three-dimensional ultrashort echo time imaging.

    abstract::There is increasing interest in imaging short T2 species which show little or no signal with conventional magnetic resonance (MR) pulse sequences. In this paper, we describe the use of three-dimensional ultrashort echo time (3D UTE) sequences with TEs down to 8 μs for imaging of these species. Image contrast was gener...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.11.003

    authors: Du J,Bydder M,Takahashi AM,Carl M,Chung CB,Bydder GM

    更新日期:2011-05-01 00:00:00

  • MRI-assisted radiation therapy planning of brain tumors--clinical experiences in 17 patients.

    abstract::A new and simple method for precise determination of lateral opposed treatment portals was developed and used in 17 patients. Compared to CT, MRI led to significant changes of portals in 59% (10/17) of cases. Individual shielding blocks could be precisely designed by use of our new method. MRI is the procedure of choi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90007-9

    authors: Just M,Rösler HP,Higer HP,Kutzner J,Thelen M

    更新日期:1991-01-01 00:00:00

  • Fractional amplitude of low-frequency fluctuation changes in monkeys with spinal cord injury: a resting-state fMRI study.

    abstract:PURPOSE:Although functional magnetic resonance imaging (fMRI) has revealed that spinal cord injury (SCI) causes anomalous changes in task-induced brain activation, its effect during the resting state remains unclear. The aim of this study is to explore the changes of the brain resting-state function in non-human primat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.02.001

    authors: Rao JS,Ma M,Zhao C,Zhang AF,Yang ZY,Liu Z,Li XG

    更新日期:2014-06-01 00:00:00

  • Ovarian Brenner tumors: MR imaging characteristics.

    abstract::This study describes the appearance of Brenner tumors on MR imaging and compares quantitative signal intensity measurements of Brenner tumors with that of other ovarian tumors. A search of pathologic and MR records disclosed patients who had MRIs showing Brenner tumors prior to surgical excision. Patients (21) with ot...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0730-725x(98)00136-2

    authors: Outwater EK,Siegelman ES,Kim B,Chiowanich P,Blasbalg R,Kilger A

    更新日期:1998-12-01 00:00:00

  • The NMR-MOUSE: quality control of elastomers.

    abstract::New applications of the NMR-MOUSE (mobile universal surface explorer) to non-destructive quality control of elastomers are reported. One example concern the thermal aging of fast clutches which was probed by measurements of 1H transverse relaxation time. Novel methodological developments show that 1H double-quantum fi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00277-6

    authors: Kühn H,Klein M,Wiesmath A,Demco DE,Blümich B,Kelm J,Gold PW

    更新日期:2001-04-01 00:00:00

  • Glutamate quantification by PRESS or MEGA-PRESS: Validation, repeatability, and concordance.

    abstract:PURPOSE:While PRESS is often employed to measure glutamate concentrations, MEGA-PRESS enables simultaneous Glx (glutamate and glutamine) and GABA measurements. This study aimed to compare validation, repeatability, and concordance of different approaches for glutamate quantification at 3T to aid future studies in their...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.12.029

    authors: van Veenendaal TM,Backes WH,van Bussel FCG,Edden RAE,Puts NAJ,Aldenkamp AP,Jansen JFA

    更新日期:2018-05-01 00:00:00

  • The Langerhans' cell histiocytosis (eosinophilic granuloma) of the cervical spine: a rare diagnosis of cervical pain.

    abstract::We present the case of a 44-year-old man who complained of cervical pain. He was treated with physiotherapy and analgetics. Because of persistent pain, computed tomography (CT) scan and MRI were performed. They revealed an osteolytic destruction of the fourth cervical vertebra. The patient was treated surgically for r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2004.01.006

    authors: Simanski C,Bouillon B,Brockmann M,Tiling T

    更新日期:2004-05-01 00:00:00

  • Simultaneous PET-MRI in oncology: a solution looking for a problem?

    abstract::With the recent development of integrated positron emission tomography-magnetic resonance imaging (PET-MRI) scanners, new possibilities for quantitative molecular imaging of cancer are realized. However, the practical advantages and potential clinical benefits of the ability to record PET and MRI data simultaneously m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2012.06.001

    authors: Yankeelov TE,Peterson TE,Abramson RG,Izquierdo-Garcia D,Arlinghaus LR,Li X,Atuegwu NC,Catana C,Manning HC,Fayad ZA,Gore JC

    更新日期:2012-11-01 00:00:00

  • Quantitative radial imaging of porous particles beds with varying water contents.

    abstract::Radial imaging protocols suitable for monitoring water transport in biopolymer and food materials during processes such as drying and rehydration are developed and tested on a well-characterized model sample. This model consisted of a randomly packed bed of Sephadex beads with varying water content. The results are in...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91238-r

    authors: Hills BP,Babonneau F

    更新日期:1994-01-01 00:00:00

  • Applications of controlled-flow laser-polarized xenon gas to porous and granular media study.

    abstract::We report initial NMR studies of continuous flow laser-polarized xenon gas, both in unrestricted tubing, and in a model porous media. The study uses Pulsed Gradient Spin Echo-based techniques in the gas-phase, with the aim of obtaining more sophisticated information than just translational self-diffusion coefficients....

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00156-5

    authors: Mair RW,Wang R,Rosen MS,Candela D,Cory DG,Walsworth RL

    更新日期:2003-04-01 00:00:00