Abstract:
:The NMR relaxivities of Gd-EOB-DTPA and Gd-DTPA were determined in the kidney and liver of intact male Wistar rats immediately following sacrifice and in vitro in solutions and gels, at 1.5 T using a clinical MR scanner, T1 and T2 values of tissue samples were derived from spin-echo image sequences. Tissue gadolinium concentrations were determined by radioassay of Gd153, Gd-EOB-DTPA T1 and T2 relaxivities, R1 and R2 (s-1 mmole-1 kg), were found to be 10.7 +/- 0.5 and 22.5 +/- 3.2 respectively, for liver, 2.4 +/- 0.2 and 12.1 +/- 1.7 for kidney cortex, 2.7 +/- 0.2 and 14.5 +/- 1.9 for kidney outer medulla, 2.0 +/- 0.2 and 11.4 +/- 2.1 for kidney inner medulla. Gd-DTPA R1 and R2 were found to be 4.8 +/- 0.4 and 14.5 +/- 3.7 for liver, 1.2 +/- 0.1 and 7.9 +/- 0.8 for kidney cortex, 1.6 +/- 0.1 and 10.2 +/- 1.4 for kidney outer medulla, 1.3 +/- 0.1 and 10.2 +/- 1.2 for kidney inner medulla. Gd-EOB-DTPA and Gd-DTPA R1 was increased in liver compared to agarose gets at 38 degrees C (4.49 +/- 0.03 and 3.47 +/- 0.06), but reduced in kidney tissues. All R2 were elevated compared to agarose gels at 38 degrees C (5.72 +/- 0.12 and 4.12 +/- 0.03). Elevated R2 and R1 (expressed in terms of the concentration of gadolinium per kg of tissue) can be accounted for in part by the lower water content of tissues compared with gels or solutions increased microviscosity and binding to macromolecules. In addition, susceptibility effects may give rise to further increases in R2. By contrast, the reduced R1 observed in kidney may be the result of compartmentalization of the magnetopharmaceuticals. Statistically improved fits were obtained for T1 recovery curves for liver in the presence of Gd-EOB-DTPA when a dual exponential model was used. Assuming in vitro values for the relaxivities of these artificial contrast agents will lead to inaccuracies when relating observed signal enhancement factors to tissue gadolinium concentration.
journal_name
Magn Reson Imagingjournal_title
Magnetic resonance imagingauthors
Shuter B,Tofts PS,Wang SC,Pope JMdoi
10.1016/0730-725x(95)02097-dsubject
Has Abstractpub_date
1996-01-01 00:00:00pages
243-53issue
3eissn
0730-725Xissn
1873-5894pii
0730-725X(95)02097-Djournal_volume
14pub_type
杂志文章abstract:PURPOSE:The state-of-the-art method to quantify sodium concentrations in vivo consists in a fully relaxed 3D spin-density (SD) weighted acquisition. Nevertheless, most sodium MRI clinical studies use short-TR SD acquisitions to reduce acquisition durations. We present a clinically viable implementation of the Variable ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.01.015
更新日期:2019-05-01 00:00:00
abstract::Functional magnetic resonance imaging (fMRI) has found widespread clinical interest. Difficulties in clinical use of the fMRI technique arise, considering the lack of knowledge about activation task performance. This accounts especially for sensorimotor activation studies, in which performance of the sensorimotor acti...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(95)02052-u
更新日期:1996-01-01 00:00:00
abstract:PURPOSE:To develop a method for estimating metabolite concentrations using phased-array coils and sensitivity-encoded (SENSE) magnetic resonance spectroscopic images (MRSI) of the human brain. MATERIALS AND METHODS:The method is based on the phantom replacement technique and uses receive coil sensitivity maps and body...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2009.11.003
更新日期:2010-04-01 00:00:00
abstract:OBJECTIVE:To characterize capillary perfusion and tissue diffusion changes in transplant renal artery stenosis (TRAS) with diffusion-weighted imaging (DWI). MATERIALS & METHODS:We retrospectively identified 30 patients with non-contrast enhanced magnetic resonance angiography-proven TRAS. Another 20 kidney transplant ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.05.007
更新日期:2019-07-01 00:00:00
abstract:PURPOSE:In this study we proposed a fully automated method for localizing and segmenting the ascending aortic lumen with phase-contrast magnetic resonance imaging (PC-MRI). MATERIAL AND METHODS:Twenty-five phase-contrast series were randomly selected out of a large population dataset of patients whose cardiac MRI exam...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2017.11.010
更新日期:2018-04-01 00:00:00
abstract::A 31-year-old male patient had a transjugular intrahepatic portal systemic shunt (TIPS) placed for acute Budd-Chiari syndrome secondary to paroxysmal nocturnal hemoglobinuria (PNH). Post-procedure, he was anticoagulated for his underlying paroxysmal nocturnal hemoglobinuria. After 11 days, he complained of upper abdom...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(98)00081-2
更新日期:1998-09-01 00:00:00
abstract::Using both quantitative computer-assisted analysis and visual estimation the MR imaging response of brain metastases to whole-brain radiotherapy (WBRT) was prospectively studied in 49 patients. Compared to the computer-assisted analysis, the precision of the visual estimation (by two readers in conference) of tumor re...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(96)00024-0
更新日期:1997-01-01 00:00:00
abstract:PURPOSE:To evaluate the application of high-resolution MRI methodology for characterizing the fluid velocity field and evaluate fluid shear field within a simplified in vitro model of a bone-implant interface. MATERIALS AND METHODS:The study used a specific micromotion canine bone implant that has been used for over a...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2005.11.001
更新日期:2006-06-01 00:00:00
abstract::The purpose of the study was to determine whether diffusion-weighted magnetic resonance imaging (DWI) could identify focal lesions that develop in ischemia-sensitive cerebral tissues during reperfusion following global brain ischemia. Localized 1H-Magnetic Resonance Spectroscopy (1H-MRS) measurements were also obtaine...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(96)00094-x
更新日期:1996-01-01 00:00:00
abstract::The effect of slice orientation on reproducibility and sensitivity of 3T fMRI activation using a motor task has been investigated in six normal volunteers. Four slice orientations were used; axial, oblique axial, coronal and sagittal. We applied analysis of variance (ANOVA) to suprathreshold voxel statistics to quanti...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(01)00399-x
更新日期:2001-12-01 00:00:00
abstract::The adiabatic Shinnar-Le Roux (SLR) algorithm for radiofrequency (RF) pulse design enables systematic control of pulse parameters such as bandwidth, RF energy distribution and duration. Some applications, such as diffusion-weighted imaging (DWI) at high magnetic fields, would benefit from RF pulses that can provide gr...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2014.04.003
更新日期:2014-09-01 00:00:00
abstract:PURPOSE:To perform comprehensive in vitro experiments using six-directional icosahedral flow encoding (ICOSA6) 4D flow magnetic resonance imaging (MRI) under various scan conditions to analyze the robustness of velocity and turbulence quantification. MATERIALS AND METHODS:In vitro flow phantoms with steady flow rates ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2020.06.020
更新日期:2020-10-01 00:00:00
abstract::Quantitative measures of rheumatoid arthritis (RA) disease progression can provide valuable tools for evaluation of new treatments during clinical trials. In this study, a novel multispectral (MS) MRI analysis method is presented to quantify changes in bone lesion volume (DeltaBLV) in the hands of RA patients. Image r...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2004.01.013
更新日期:2004-05-01 00:00:00
abstract::Truncation artifacts arise in magnetic resonance spectroscopic imaging (MRSI) of the human brain due to limited coverage of k-space necessitated by low SNR of metabolite signal and limited scanning time. In proton MRSI of the head, intense extra-cranial lipid signals "bleed" into brain regions, thereby contaminating s...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(02)00608-2
更新日期:2002-12-01 00:00:00
abstract:BACKGROUND:Since the advent of magnetic resonance imaging, metal artifacts have posed an important diagnostic problem in different fields of medicine. However, this has not been systematically studied in patients undergoing surgery for brain tumors. OBJECTIVE:This study was planned to assess whether metal artifacts ca...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2012.11.001
更新日期:2013-06-01 00:00:00
abstract::The purpose of this study was to assess the benefits of a 3 T scanner and an eight-channel phased-array head coil for acquiring three-dimensional PRESS (Point REsolved Spectral Selection) proton (H-1) magnetic resonance spectroscopic imaging (MRSI) data from the brains of volunteers and patients with brain tumors rela...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2006.07.012
更新日期:2006-12-01 00:00:00
abstract::Functional MR (fMR) imaging techniques based on blood oxygenation level dependent (BOLD) effects were developed and applied to a rat brain tumor model to evaluate the potential utility of the method for characterizing tumor growth and regression following treatment. Rats bearing 9L brain tumors in situ were imaged dur...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(98)00208-2
更新日期:1999-05-01 00:00:00
abstract::Magnetic field gradients play a fundamental role in MR imaging and localized spectroscopy. The MRI experiment, in particular fast MRI, relies on precise gradient switching, which has become more demanding with the constantly growing number of fast imaging techniques. Here we present a simple MR method to measure the b...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2007.02.002
更新日期:2007-11-01 00:00:00
abstract::Echo planar imaging (EPI) was extended for the acquisition of both, the spin-echo (SE) and the stimulated echo in a stimulated echo sequence after one excitation from thermal equilibrium. The two independent EPI images reflect different states of the transverse magnetization excited and measured almost simultaneously....
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)91234-n
更新日期:1994-01-01 00:00:00
abstract::Functional magnetic resonance imaging favors the use of multi-slice gradient-recalled echo-planar imaging due to its short image acquisition times, whole brain coverage and sensitivity to BOLD contrast. However, despite its advantages, gradient-recalled echo-planar imaging also is sensitive to static magnetic field gr...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(00)00199-5
更新日期:2000-11-01 00:00:00
abstract::We propose a novel processing method for reducing shading artifacts in quantitative susceptibility mapping (QSM) for prostate imaging. In the conventional method, calculation errors in the boundary regions between water and fat cause shading artifacts that degrade the image quality for QSM. In the proposed method, wat...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.11.006
更新日期:2020-02-01 00:00:00
abstract::To determine if magnetic resonance imaging (MRI) can be used to detect tissue viability in segments with persistent 201T1 defects early following acute myocardial infarction, 24 patients underwent MRI and adenosine 201T1 single photon emission computed tomography (SPECT) imaging at approximately 6 days. Infarction was...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(93)90214-x
更新日期:1993-01-01 00:00:00
abstract::Magnetic resonance (MR) imaging has been shown to provide accurate measurements of right ventricular (RV) volumes and myocardial mass. The purpose of this study was to evaluate the reproducibility of MR imaging, which in clinical practice may be as important as its absolute accuracy. The reproducibility of MR imaging ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)00076-f
更新日期:1995-01-01 00:00:00
abstract::We have applied diffusion and relaxation Nuclear Magnetic Resonance experiments to investigate the translational and rotational mobility of adsorbents on quartz and calcite mineral surfaces. On both surfaces it was found that water is the dominant molecule. On the quartz surface the majority of water molecules have a ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2018.10.002
更新日期:2019-02-01 00:00:00
abstract::The HASTE (half-Fourier acquisition single-shot turbo spin-echo) technique delivers images with T2-weighting in about half a second and could be ideal for fast dynamic studies when T2-weighting is needed. We evaluated cardiac-triggered HASTE to study cervical spine flexion/extension. The cervical spines of ten asympto...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(98)00176-3
更新日期:1999-04-01 00:00:00
abstract::We compared the ability of magnetic resonance imaging (MRI) using a 0.064 T permanent magnet, three-phase bone scanning, and indium-labeled white blood cell (111In-WBC) scanning, to diagnose osteomyelitis. Twenty-three patients underwent biopsy. All patients were examined at presentation with all three modalities. Sen...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(91)90540-3
更新日期:1991-01-01 00:00:00
abstract::Magnetic resonance imaging (MRI) has been applied to assess kidney function in normal rats by monitoring the passage of the extracellular contrast agent GdDOTA. High-resolution images have been obtained using either the rapid acquisition with relaxation enhancement (RARE) or the snapshot pulse sequence. The latter was...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(00)00134-x
更新日期:2000-06-01 00:00:00
abstract::The discrimination of tumor boundaries from normal tissue, as well as the evaluation of tissue heterogeneity and tumor grading often continue to pose a challenge in MRI. Although yielding promising results in various fields of medical imaging, two- dimensional (2D) texture analysis in MRI has, until now, demonstrated ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(03)00201-7
更新日期:2003-11-01 00:00:00
abstract:PURPOSE:This study aimed to establish the topographical and zonal T2 patterns of multi-resolution MRI in medial tibial cartilage in a canine model of osteoarthritis (OA), initiated by the anterior cruciate ligament (ACL) transection surgery, and studied after 8-weeks and 12-weeks post-surgery. METHODS:Articular cartil...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2021.01.002
更新日期:2021-01-22 00:00:00
abstract::Changes in both blood flow and blood oxygenation determine the functional MRI (fMRI) signal. In the present study factors responsible for blood oxygenation (e.g., FiO(2)) were held constant so that changes in pixel count would above all reflect changes in regional cerebral blood flow (rCBF). Continuous positive airway...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(00)00229-0
更新日期:2001-01-01 00:00:00