Quantitative assessment of rat kidney function by measuring the clearance of the contrast agent Gd(DOTA) using dynamic MRI.

Abstract:

:Magnetic resonance imaging (MRI) has been applied to assess kidney function in normal rats by monitoring the passage of the extracellular contrast agent GdDOTA. High-resolution images have been obtained using either the rapid acquisition with relaxation enhancement (RARE) or the snapshot pulse sequence. The latter was superior in anatomic definition due to the shorter echo delays used. The GdDOTA induced signal enhancements in the various renal structures were theoretically modeled and the results of the regression analysis then used to estimate local tissue concentrations in renal cortex, inner medulla and outer medulla/pelvis. The concentration-time curves in vena cava and renal cortex were similar and distinctly different from the ones in medulla and pelvis. This is reflected in the time-to-peak (TTP) values, which were TTP (blood) = 0.18 +/- 0.03 < TTP (cortex) = 0.26 +/- 0.05 < TTP (outer medulla) = 0.62 +/- 0.03 < TTP (inner medulla/pelvis) = 0.92 +/- 0.16 min. The initial tracer uptake rates depended linearly on the dose of GdDOTA administered, the value of the uptake rate in the cortex being significantly higher than those in the outer and inner medulla, which were identical within error limits. The initial medullar tracer uptake followed a first-order kinetics. The rate constant k(cl) = (dc[medulla]/dt)/c[cortex] = 3.4 +/- 0.5 min(-1) for the transition from cortex (predominantly blood signal) to medulla (predominantly urine) was considered a measure for the renal clearance. Intravenous administration of furosemide at doses 2.5, 5, and 10 mg/kg led to a dose-dependent decrease of k(cl). This reflects the inhibitory effect of the diuretic furosemide on medullary water resorption and thus the dilution of the GdDOTA in urine.

journal_name

Magn Reson Imaging

authors

Baumann D,Rudin M

doi

10.1016/s0730-725x(00)00134-x

subject

Has Abstract

pub_date

2000-06-01 00:00:00

pages

587-95

issue

5

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(00)00134-X

journal_volume

18

pub_type

杂志文章
  • Comparison of different methods for combining phase-contrast images obtained with multiple coils.

    abstract::The ability to determine coil sensitivities implies that a method optimized in terms of maximized signal-to-noise ratio (SNR) can be applied to the combination of multiple coil images. An optimization of SNR subsequently results in a minimized variance in quantitative velocity measurements using phase-contrast imaging...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.06.002

    authors: Thunberg P,Karlsson M,Wigström L

    更新日期:2005-09-01 00:00:00

  • Simultaneous optimization of power and duration of radio-frequency pulse in PARACEST MRI.

    abstract::Chemical exchange saturation transfer (CEST) MRI is increasingly used to probe mobile proteins and microenvironment properties, and shows great promise for tumor and stroke diagnosis. The CEST effect is complex and depends not only on the CEST agent concentration, exchange rates, the characteristic of the magnetizatio...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.02.001

    authors: Rezaeian MR,Hossein-Zadeh GA,Soltanian-Zadeh H

    更新日期:2016-07-01 00:00:00

  • Spectroscopic imaging of the brain with phased-array coils at 3.0 T.

    abstract::The goal of this study was to develop and evaluate high-resolution magnetic resonance spectroscopic imaging (MRSI) utilizing the gains in signal-to-noise ratio (SNR) provided by combining higher magnetic field with high-sensitivity phased-array (PA) coils. We investigated the maximum improvement in spatial resolution ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.019

    authors: Xu D,Chen AP,Cunningham C,Osorio JA,Nelson SJ,Vigneron DB

    更新日期:2006-01-01 00:00:00

  • Functional MR imaging of visual and motor cortex stimulation at high temporal resolution using a FLASH technique on a standard 1.5 Tesla scanner.

    abstract::Functional magnetic resonance imaging (fMRI) was performed on a conventional 1.5 T scanner by means of a modified FLASH-technique at temporal resolutions of 80 and 320 ms. The method's stability was assessed by phantom measurements and by investigation of three volunteers resulting in a low amplitude (3%) periodic (4 ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(96)00021-5

    authors: Wiener E,Schad LR,Baudendistel KT,Essig M,Müller E,Lorenz WJ

    更新日期:1996-01-01 00:00:00

  • Towards quantitative evaluation of wall shear stress from 4D flow imaging.

    abstract::Wall shear stress (WSS) is a relevant hemodynamic indicator of the local stress applied on the endothelium surface. More specifically, its spatiotemporal distribution reveals crucial in the evolution of many pathologies such as aneurysm, stenosis, and atherosclerosis. This paper introduces a new solution, called PaLMA...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.08.017

    authors: Levilly S,Castagna M,Idier J,Bonnefoy F,Le Touzé D,Moussaoui S,Paul-Gilloteaux P,Serfaty JM

    更新日期:2020-12-01 00:00:00

  • Technical evaluation of in vivo abdominal fat and IMCL quantification using MRI and MRSI at 3 T.

    abstract:OBJECTIVES:The objectives of this study were to develop protocols that measure abdominal fat and calf muscle lipids with magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS), respectively, at 3 T and to examine the correlation between these parameters and insulin sensitivity. MATERIALS AND METHOD...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.06.006

    authors: Li X,Youngren JF,Hyun B,Sakkas GK,Mulligan K,Majumdar S,Masharani UB,Schambelan M,Goldfine ID

    更新日期:2008-02-01 00:00:00

  • High resolution simultaneous imaging of intracranial and extracranial arterial wall with improved cerebrospinal fluid suppression.

    abstract:PURPOSE:To develop a technique for three dimensional (3D) high resolution joint imaging of intracranial and extracranial arterial walls with improved cerebrospinal fluid (CSF) suppression and good blood suppression based on T1 weighted sampling perfection with application optimized contrast using different angle evolut...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.08.004

    authors: Zhang L,Zhang N,Wu J,Liu X,Chung YC

    更新日期:2017-12-01 00:00:00

  • Internal derangement of the temporomandibular joint: radiologic staging with clinical, surgical, and pathologic correlation.

    abstract::The radiologic findings from 60 patients with 86 internally deranged temporomandibular joints (TMJ) upon whom sequential imaging procedures had been performed over a period of two months to ten years were analyzed and correlated with clinical, surgical (72 joints), and pathological observations. Internal derangement o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90404-9

    authors: Schellhas KP

    更新日期:1989-09-01 00:00:00

  • Acute effects of exercise on muscle MRI in peripheral arterial occlusive disease.

    abstract::The midcalf muscles of eight patients who had peripheral arterial occlusive disease were evaluated by exercise MRI before and after bypass surgery or percutaneous transluminal angioplasty. MRI showed a high intensity of these muscles, especially the posterior muscles, after exercise in all patients before intervention...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00018-c

    authors: Yoshioka H,Anno I,Kuramoto K,Matsumoto K,Jikuya T,Itai Y

    更新日期:1995-01-01 00:00:00

  • Adaptive total linear least square method for quantification of mean transit time in brain perfusion MRI.

    abstract::Absolute quantification of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) are of great relevance for clinical applications. One of the widely used methods for quantification of these parameters is gamma-variate fitting. Traditional nonlinear regression methods for gamma-variate fit...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00075-4

    authors: Li X,Tian J,Li E,Wang X,Dai J,Ai L

    更新日期:2003-06-01 00:00:00

  • The Langerhans' cell histiocytosis (eosinophilic granuloma) of the cervical spine: a rare diagnosis of cervical pain.

    abstract::We present the case of a 44-year-old man who complained of cervical pain. He was treated with physiotherapy and analgetics. Because of persistent pain, computed tomography (CT) scan and MRI were performed. They revealed an osteolytic destruction of the fourth cervical vertebra. The patient was treated surgically for r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2004.01.006

    authors: Simanski C,Bouillon B,Brockmann M,Tiling T

    更新日期:2004-05-01 00:00:00

  • Assessing image artifacts from radiotherapy electromagnetic transponders with metal-artifact reduction imaging.

    abstract::Image artifacts due to 14 gauge radiotherapy electromagnetic (EM) transponders were assessed on conventional spin echo images, and corrected using metal artifact reduction techniques: high bandwidth, view angle tilting (VAT), and slice encoding for metal artifact correction (SEMAC). Large areas of signal loss and/or p...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.02.005

    authors: Bergen RV,Ryner L

    更新日期:2019-06-01 00:00:00

  • Probe efficiency improvement with remote and transmission line tuning and matching.

    abstract::In certain nuclear magnetic resonance (NMR) applications in which accessibility to the gantry is limited, performing optimal tuning and matching represents a major problem. Here, we discuss a method of tuning NMR probe circuits and matching their impedances which uses cables with different impedance values. This simpl...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00051-x

    authors: Villa P,Vaquero JJ,Chesnick S,Ruiz-Cabello J

    更新日期:1999-09-01 00:00:00

  • Comparison of BLADE and conventional T2-TSE sequences for the sagittal visualization of the cervical spinal cord in multiple sclerosis patients - a case report.

    abstract::The purpose of this study is to report the significant differences found in the identification of lesions in cervical spinal cord of two patients with multiple sclerosis when using the BLADE T2-TSE and BLADE T2-TIRM sequences as opposed to the conventional T2-TSE and T2-TIRM sequences for sagittal acquisition at 1.5T....

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.07.008

    authors: Lavdas E,Mavroidis P,Topaltzikis T,Slatinopoulos V,Roka V,Vlachopoulou A,Papanikolaou N,Stathakis S,Kapsalaki E,Batsikas G

    更新日期:2013-12-01 00:00:00

  • Sampling time effects on signal-to-noise and contrast-to-noise ratios in spin-echo MRI.

    abstract::This work discusses the effect of sampling time on noise, signal-to-noise and contrast-to-noise ratios in magnetic resonance imaging. A simple imaging experiment is performed to demonstrate the effect of sampling time on noise, confirming theoretical expectations that doubling the sampling time while decreasing the re...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90481-4

    authors: Hendrick RE

    更新日期:1987-01-01 00:00:00

  • Arterial input functions (AIFs) measured directly from arteries with low and standard doses of contrast agent, and AIFs derived from reference tissues.

    abstract::Measurements of arterial input function (AIF) can have large systematic errors at standard contrast agent doses in dynamic contrast enhanced MRI (DCE-MRI). We compared measured AIFs from low dose (AIFLD) and standard dose (AIFSD) contrast agent injections, as well as the AIF derived from a muscle reference tissue and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.10.025

    authors: Wang S,Fan X,Medved M,Pineda FD,Yousuf A,Oto A,Karczmar GS

    更新日期:2016-02-01 00:00:00

  • Off-resonance correction using an estimated linear time map.

    abstract::Images acquired in the presence of magnetic field deviations and reconstructed without taking into account the off-resonance, are distorted and corrupted with artifacts. Several post-processing algorithms have been developed for correcting the distortion when it is not possible to fix the field inhomogeneities. These ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00487-3

    authors: Akel JA,Rosenblitt M,Irarrazaval P

    更新日期:2002-02-01 00:00:00

  • Evaluation of EPI distortion correction methods for quantitative MRI of the brain at high magnetic field.

    abstract::High field MRI has been applied to high-resolution structural and functional imaging of the brain. Echo planar imaging (EPI) is an ultrafast acquisition technique widely used in diffusion imaging, functional MRI and perfusion imaging. However, it suffers from geometric and intensity distortions caused by static magnet...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.06.010

    authors: Hong X,To XV,Teh I,Soh JR,Chuang KH

    更新日期:2015-11-01 00:00:00

  • Echo-shifted multislice EPI for high-speed fMRI.

    abstract::The advantages of event-related functional Magnetic Resonance Imaging (fMRI) and the increasing use of fMRI in cognitive experiments are both driving the development of techniques that allow images sensitive to the blood oxygen level-dependent effect to be acquired at ever-higher temporal resolution. Here, we present ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.030

    authors: Gibson A,Peters AM,Bowtell R

    更新日期:2006-05-01 00:00:00

  • Validation of estimated 3D temperature maps during hepatic cryo surgery.

    abstract::A simple model for estimating temperature distribution within the frozen region during cryo ablation was tested for accuracy. Freezing experiments were conducted in both ex vivo and in vivo porcine livers. Temperature was measured during freezing using a fiber-optic temperature sensor. Three-dimensional MR images were...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00389-7

    authors: Samset E,Mala T,Edwin B,Gladhaug I,Søreide O,Fosse E

    更新日期:2001-06-01 00:00:00

  • Magnetization transfer and T2 quantitation in normal appearing cortical gray matter and white matter adjacent to focal abnormality in patients with traumatic brain injury.

    abstract::Traumatic brain injury (TBI) is one of the commonest causes of morbidity and mortality in the developed countries with posttraumatic epilepsy and functional disability being its major sequelae. The purpose of this study was to test the hypothesis whether the normal appearing adjacent gray and white matter regions on T...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00189-9

    authors: Kumar R,Gupta RK,Rao SB,Chawla S,Husain M,Rathore RK

    更新日期:2003-10-01 00:00:00

  • A fast spin echo two-point Dixon technique and its combination with sensitivity encoding for efficient T2-weighted imaging.

    abstract::A fast spin echo two-point Dixon (fast 2PD) technique was developed for efficient T2-weighted imaging with uniform water and fat separation. The technique acquires two interleaved fast spin echo images with water and fat in-phase and 180 degrees out-of-phase, respectively, and generates automatically separate water an...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.005

    authors: Ma J,Son JB,Bankson JA,Stafford RJ,Choi H,Ragan D

    更新日期:2005-12-01 00:00:00

  • COmplex-Model-Based Estimation of thermal noise for fMRI data in the presence of artifacts.

    abstract::Due to the presence of artifacts induced by fast-imaging acquisition in functional magnetic resonance imaging (fMRI) studies, it is very difficult to estimate the variance of thermal noise by traditional methods in magnitude images. Moreover, the existence of incidental phase fluctuations impairs the validity of curre...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.12.007

    authors: Xu Y,Wu G,Rowe DB,Ma Y,Zhang R,Xu G,Li SJ

    更新日期:2007-09-01 00:00:00

  • High-energy phosphate metabolism during incremental calf exercise in humans measured by 31 phosphorus magnetic resonance spectroscopy (31P MRS).

    abstract::Several previous 31 phosphorus magnetic resonance spectroscopy ((31)P MRS) studies performing incremental or progressive muscle exercises have observed that a decrease in pH is accompanied with an acceleration in phosphocreatine (PCr) hydrolysis. The purpose of this study was to investigate the relationship between PC...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.07.001

    authors: Schocke MF,Esterhammer R,Kammerlander C,Rass A,Kremser C,Fraedrich G,Jaschke WR,Greiner A

    更新日期:2004-01-01 00:00:00

  • Different magnetic resonance imaging features in two types of nontraumatic rabbit osteonecrosis models.

    abstract::A single injection of high-dose steroid (20 mg/kg) has been reported to induce necrotic lesions in the proximal metaphysis and diaphysis of the rabbit femur. In the rabbit osteonecrosis (ON) model induced by two-dose horse serum injections, contrast-enhanced magnetic resonance imaging (MRI) and T2*-weighted dynamic MR...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.07.001

    authors: Takao M,Sugano N,Nishii T,Sakai T,Nakamura N,Yoshikawa H

    更新日期:2009-02-01 00:00:00

  • Dose distribution of proton beams with NMR measurements of Fricke-agarose gels.

    abstract::Fricke-agarose gels have been irradiated with a proton beam. Then samples have been extracted at different depths with respect to the beam penetration distance, corresponding to different irradiation doses. Relaxation times T1 and T2, measured at 17 MHz, appear sensitive to this kind of radiation. In particular, T2 ex...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00380-3

    authors: Di Capua S,D'Errico F,Egger E,Guidoni L,Luciani AM,Rosi A,Viti V

    更新日期:1997-01-01 00:00:00

  • Functional magnetic resonance imaging in a stereotactic setup.

    abstract::The localization of critical structures within the brain is important for the planning of therapeutic strategies. Functional MRI is capable to assess functional response of cortical structures to certain stimuli. The authors present two techniques for functional MRI (fMRI) in a stereotactic set-up. The skull of the pa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)02108-x

    authors: Debus J,Essig M,Schad LR,Wenz F,Baudendistel K,Knopp MV,Engenhart R,Lorenz WJ

    更新日期:1996-01-01 00:00:00

  • Phase contrast and time-of-flight magnetic resonance angiography of the intracerebral arteries at 1.5, 3 and 7 T.

    abstract:PURPOSE:Time-of-flight (ToF) and phase contrast (PC) magnetic resonance angiographies (MRAs) are noninvasive applications to depict the cerebral arteries. Both approaches can image the cerebral vasculature without the administration of intravenous contrast. Therefore, it is used in routine clinical evaluation of cerebr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.10.023

    authors: Stamm AC,Wright CL,Knopp MV,Schmalbrock P,Heverhagen JT

    更新日期:2013-05-01 00:00:00

  • Equivalent cross-relaxation rate imaging positively correlates with pathological grade and cell density of adipocytic tumors.

    abstract:OBJECTIVE:Equivalent cross-relaxation rate imaging (ECRI) is an MRI technique used to evaluate qualitative changes in protein-water interactions. We aimed to prospectively evaluate the utility of ECRI for classification of adipocytic tumors. MATERIALS AND METHODS:Institutional Review Board approval was obtained and al...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.12.004

    authors: Okuda H,Matsushima S,Sugiura H,Yamada K,Hamada S,Nishida Y,Ishiguro N

    更新日期:2014-04-01 00:00:00

  • Acute pancreatic graft fistula and peripancreatic fluid collection: demonstration by secretin-stimulated MRI.

    abstract::Peripancreatic fluid collections are among the common post pancreas transplant complications, which are mainly due to leakage from the anastomosis site to bowel and graft pancreatitis. Differentiation between these two entities is important because they are treated differently. In this case, secretin stimulated magnet...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.02.003

    authors: Alkaade S,Fattahi R,Balci NC,Akduman EI,Garvin PJ,Modanlou KA,Burton FR

    更新日期:2009-09-01 00:00:00