Echo-shifted multislice EPI for high-speed fMRI.

Abstract:

:The advantages of event-related functional Magnetic Resonance Imaging (fMRI) and the increasing use of fMRI in cognitive experiments are both driving the development of techniques that allow images sensitive to the blood oxygen level-dependent effect to be acquired at ever-higher temporal resolution. Here, we present a technique based on the use of echo shifting (ES) in conjunction with a multislice (MS) echo planar imaging (EPI) readout, which allows T2*-weighted images to be generated with a repetition time per slice that is less than the echo time (TE). Using this ES-MS-EPI approach, it is shown that images with a TE of 40 ms can be acquired with an acquisition time per slice of only 27 ms. The utility of the MS-ES-EPI sequence is demonstrated in a visual-motor, event-related fMRI study in which nine-slice image volumes are acquired continuously at a rate of 4.1 Hz. The sequence is shown to produce reliable activation associated with both visual stimuli and motor actions.

journal_name

Magn Reson Imaging

authors

Gibson A,Peters AM,Bowtell R

doi

10.1016/j.mri.2005.12.030

subject

Has Abstract

pub_date

2006-05-01 00:00:00

pages

433-42

issue

4

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(06)00044-0

journal_volume

24

pub_type

杂志文章
  • Chemical exchange magnetic resonance imaging (CHEMI).

    abstract::Systems investigated with NMR spectroscopy are sometimes heterogeneous with respect to chemical composition, rates of chemical exchange, and other properties influencing magnetic resonance parameters. A method was developed to spatially encode reaction kinetic information and produce NMR images sensitive to chemical e...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90125-7

    authors: McFarland EW,Neuringer LJ,Kushmerick MJ

    更新日期:1988-09-01 00:00:00

  • Dielectric resonances and B(1) field inhomogeneity in UHFMRI: computational analysis and experimental findings.

    abstract::B(1) Field inhomogeneity and the relative effects of dielectric resonances are analyzed within the context of ultra high field MRI. This is accomplished by calculating the electromagnetic fields inside spherical phantoms and within a human head model in the presence and absence of an RF coil. These calculations are th...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00300-9

    authors: Ibrahim TS,Lee R,Abduljalil AM,Baertlein BA,Robitaille PM

    更新日期:2001-02-01 00:00:00

  • Noncontrast MRI with diffusion-weighted imaging as the sole imaging modality for detecting liver malignancy in patients with high risk for hepatocellular carcinoma.

    abstract:PURPOSE:To compare the diagnostic performance of the noncontrast MRI including DWI to the standard MRI for detecting hepatic malignancies in patients with chronic liver disease. MATERIALS AND METHODS:We included 135 patients with 136 histologically-confirmed hepatocellular carcinomas (HCCs), 12 cholangiocarcinomas, an...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.12.021

    authors: Kim YK,Kim YK,Park HJ,Park MJ,Lee WJ,Choi D

    更新日期:2014-07-01 00:00:00

  • Three dimensional k-space trajectory design using genetic algorithms.

    abstract::Image quality and total scan time in MRI are determined in large part by the trajectory employed to sample the Fourier space. Each trajectory has different properties like coverage of k-space, scan time, sensitivity to off-resonance conditions, etc. These properties are often contradictory, therefore a universal optim...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00174-7

    authors: Sabat S,Mir R,Guarini M,Guesalaga A,Irarrazaval P

    更新日期:2003-09-01 00:00:00

  • Fast and exact flow measurements with the fast Fourier flow technique.

    abstract::The fast Fourier flow technique offers a convenient way for extremely exact flow measurements. In combination with ECG gating, arterial flow can be studied. The total acquisition time for a single measurement is about 10 s, an ECG-gated cine sequence can be acquired in about 4 min. Fast Fourier flow can, therefore, be...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90473-0

    authors: Hennig J,Mueri M,Brunner P,Friedburg H

    更新日期:1988-07-01 00:00:00

  • Computer-assisted design of surface coils used in magnetic resonance imaging. I. The calculation of the magnetic field.

    abstract::For a number of reasons, it is desirable to fabricate coils which, for a known current, shall produce predetermined values of the magnetic field intensity at a number of points within a nuclear magnetic resonance imager. The calculation of the magnetic field intensity at a set of points involves the integration of the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90524-9

    authors: Letcher JH

    更新日期:1989-11-01 00:00:00

  • A computer algorithm for the simulation of any nuclear magnetic resonance (NMR) imaging method.

    abstract::More than a dozen Nuclear Magnetic Resonance (NMR) imaging methods have been described using different radio-frequency pulse sequences, magnetic field gradient variations, and data processing. In order to have a theoretical understanding in the most general case, we have conceived a computer program for the simulation...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(84)90065-1

    authors: Bittoun J,Taquin J,Sauzade M

    更新日期:1984-01-01 00:00:00

  • Effect of physiological heart rate variability on quantitative T2 measurement with ECG-gated Fast Spin Echo (FSE) sequence and its retrospective correction.

    abstract:OBJECT:Quantitative T2 measurement is applied in cardiac Magnetic Resonance Imaging (MRI) for the diagnosis and follow-up of myocardial pathologies. Standard Electrocardiogram (ECG)-gated fast spin echo pulse sequences can be used clinically for T2 assessment, with multiple breath-holds. However, heart rate is subject ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.06.006

    authors: de Roquefeuil M,Vuissoz PA,Escanyé JM,Felblinger J

    更新日期:2013-11-01 00:00:00

  • MR characteristics of neoplasms and vascular malformations associated with epilepsy.

    abstract::We assessed the magnetic resonance (MR) imaging characteristics of two categories of epileptogenic substrates, neoplasms, and vascular malformations, to determine MR sensitivity and typical imaging features. A blinded retrospective analysis was performed on MR scans from 41 patients who had a neoplasm or vascular malf...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02026-p

    authors: Bronen RA,Fulbright RK,Spencer DD,Spencer SS,Kim JH,Lange RC

    更新日期:1995-01-01 00:00:00

  • A simple way to acquire T(1)-weighted MR images of rat liver with respiratory triggering.

    abstract::To acquire high-resolution T(1)-weighted images of the liver in rats, for which breath-holding cannot be ensured, respiratory triggering is essential. At the respiratory rate of 30-60 times/min in rats, however, T(1)-weighted images cannot be obtained with simple triggering. As a simple solution to this, we applied mu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.10.005

    authors: Morikawa S,Murayama H,Fujimoto S,Shiino A,Inubushi T

    更新日期:2012-04-01 00:00:00

  • Spatial normalization, bulk motion correction and coregistration for functional magnetic resonance imaging of the human cervical spinal cord and brainstem.

    abstract::Functional magnetic resonance imaging (fMRI) of the cortex is a powerful tool for neuroscience research, and its use has been extended into the brainstem and spinal cord as well. However, there are significant technical challenges with extrapolating the developments that have been achieved in the cortex to their use i...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.01.038

    authors: Stroman PW,Figley CR,Cahill CM

    更新日期:2008-07-01 00:00:00

  • AG-013736, a novel inhibitor of VEGF receptor tyrosine kinases, inhibits breast cancer growth and decreases vascular permeability as detected by dynamic contrast-enhanced magnetic resonance imaging.

    abstract::Dynamic contrast-enhanced MRI (DCE-MRI) was used to noninvasively evaluate the effects of AG-03736, a novel inhibitor of vascular endothelial growth factor (VEGF) receptor tyrosine kinases, on tumor microvasculature in a breast cancer model. First, a dose response study was undertaken to determine the responsiveness o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.09.041

    authors: Wilmes LJ,Pallavicini MG,Fleming LM,Gibbs J,Wang D,Li KL,Partridge SC,Henry RG,Shalinsky DR,Hu-Lowe D,Park JW,McShane TM,Lu Y,Brasch RC,Hylton NM

    更新日期:2007-04-01 00:00:00

  • Interpretation of restricted diffusion in sandstones with internal field gradients.

    abstract::We report on experiments to characterize internal magnetic field gradients that are caused by magnetic susceptibility differences between the solid phase and the fluids filling the pore space. Our measurements focus on low-field relaxometry of brine and oil in sandstones from various reservoirs around the world. Our r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00287-9

    authors: Appel M,Freeman JJ,Gardner JS,Hirasaki GH,Zhang QG,Shafer JL

    更新日期:2001-04-01 00:00:00

  • Quantitation of normal canine hippocampus formation volume: correlation of MRI with gross histology.

    abstract::The hippocampal formation possesses an important role in the development and maintenance of short-term memory. In this study, magnetic resonance imaging (MRI) and gross histology were used to quantify the volume of the hippocampal formation in canines. High resolution MRI, using 1 mm thick slices and an intraplanar re...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02083-6

    authors: Vullo T,Deo-Narine V,Stallmeyer MJ,Gomez DG,Cahill PT

    更新日期:1996-01-01 00:00:00

  • Early assessment of breast cancer response to neoadjuvant chemotherapy by semi-quantitative analysis of high-temporal resolution DCE-MRI: preliminary results.

    abstract:PURPOSE:To evaluate whether semi-quantitative analysis of high temporal resolution dynamic contrast-enhanced MRI (DCE-MRI) acquired early in treatment can predict the response of locally advanced breast cancer (LABC) to neoadjuvant chemotherapy (NAC). MATERIALS AND METHODS:As part of an IRB-approved prospective study,...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.mri.2013.07.002

    authors: Abramson RG,Li X,Hoyt TL,Su PF,Arlinghaus LR,Wilson KJ,Abramson VG,Chakravarthy AB,Yankeelov TE

    更新日期:2013-11-01 00:00:00

  • The Elgin marvel: using magnetic resonance imaging to look at a moldic fossil from the Permian of Elgin, Scotland, UK.

    abstract::The successful use of magnetic resonance imaging (MRI) of a moldic fossil dicynodont from the Permian aeolian Hopeman Sandstone Formation of Elgin, Scotland, UK, provides paleontologists with a nondestructive technique for examining fossils preserved in this fashion. For large moldic fossils, medical scanners such as ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.09.006

    authors: Clark ND,Adams C,Lawton T,Cruickshank AR,Woods K

    更新日期:2004-02-01 00:00:00

  • Initial clinical evaluation of gadolinium DTPA for contrast-enhanced magnetic resonance imaging.

    abstract::Gadolinium DTPA was evaluated as an intravenous contrast agent for magnetic resonance imaging in 15 patients with primary or secondary intracranial neoplastic disease. T1 and T2 weighted images were obtained prior to contrast administration. T1 weighted spin echo 35/800 (TE/TR) images were utilized to detect enhanceme...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(85)90006-2

    authors: Runge VM,Schoerner W,Niendorf HP,Laniado M,Koehler D,Claussen C,Felix R,James AE Jr

    更新日期:1985-01-01 00:00:00

  • Lateral ventricular cerebrospinal fluid diffusivity as a potential neuroimaging marker of brain temperature in multiple sclerosis: a hypothesis and implications.

    abstract::In this retrospective study we tested the hypothesis that the net effect of impaired electrical conduction and therefore increased heat dissipation in multiple sclerosis (MS) results in elevated lateral ventricular (LV) cerebrospinal fluid (CSF) diffusivity as a measure of brain temperature estimated in vivo using dif...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.11.002

    authors: Hasan KM,Lincoln JA,Nelson FM,Wolinsky JS,Narayana PA

    更新日期:2015-04-01 00:00:00

  • Fast reconstruction of highly undersampled MR images using one and two dimensional principal component analysis.

    abstract::Recent compressed sensing techniques allow signal acquisition with less sampling than required by the Nyquist-Shannon theorem which reduces the data acquisition time in magnetic resonance imaging (MRI). However, prior knowledge becomes essential to reconstruct detailed features when the sampling rate is exceedingly lo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.10.009

    authors: Zong F,d'Eurydice MN,Galvosas P

    更新日期:2016-02-01 00:00:00

  • Simultaneous recording of neuronal signals and functional NMR imaging.

    abstract::We recently directly examined the relationship between blood-oxygen-level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signals and neural activity by simultaneously acquiring electrophysiological and fMRI data from monkeys in a 4.7-T vertical scanner (Logothetis NK, Pauls J, Augath MA, Trinath T, Oelt...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.03.015

    authors: Oeltermann A,Augath MA,Logothetis NK

    更新日期:2007-07-01 00:00:00

  • The relaxivity of Gd-EOB-DTPA and Gd-DTPA in liver and kidney of the Wistar rat.

    abstract::The NMR relaxivities of Gd-EOB-DTPA and Gd-DTPA were determined in the kidney and liver of intact male Wistar rats immediately following sacrifice and in vitro in solutions and gels, at 1.5 T using a clinical MR scanner, T1 and T2 values of tissue samples were derived from spin-echo image sequences. Tissue gadolinium ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02097-d

    authors: Shuter B,Tofts PS,Wang SC,Pope JM

    更新日期:1996-01-01 00:00:00

  • Background parenchymal enhancement in the contralateral normal breast of patients undergoing neoadjuvant chemotherapy measured by DCE-MRI.

    abstract::The purpose of this study was to analyze background parenchymal enhancement (BPE) in the contralateral normal breast of cancer patients during the course of neoadjuvant chemotherapy (NAC). Forty-five subjects were analyzed. Each patient had three MRIs, one baseline (B/L) and two follow-up (F/U) studies. The fibrogland...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.07.014

    authors: Chen JH,Yu H,Lin M,Mehta RS,Su MY

    更新日期:2013-11-01 00:00:00

  • Breath-hold T2-weighted sequences of the liver: a comparison of four techniques at 1.0 and 1.5 T.

    abstract::T2-weighted images are considered the most sensitive for lesion detection at high field; however, long imaging time is problematic. Accordingly, the authors compared four breath-hold T2 or T2* weighted sequences comprising T2*-weighted FLASH, T2*-weighted PSIF, T2-weighted rapid spin echo (RASE), and T2-weighted Turbo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90371-6

    authors: Simm FC,Semelka RC,Recht M,Deimling M,Lenz G,Laub GA

    更新日期:1992-01-01 00:00:00

  • Functional magnetic resonance imaging in a stereotactic setup.

    abstract::The localization of critical structures within the brain is important for the planning of therapeutic strategies. Functional MRI is capable to assess functional response of cortical structures to certain stimuli. The authors present two techniques for functional MRI (fMRI) in a stereotactic set-up. The skull of the pa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)02108-x

    authors: Debus J,Essig M,Schad LR,Wenz F,Baudendistel K,Knopp MV,Engenhart R,Lorenz WJ

    更新日期:1996-01-01 00:00:00

  • A fast spin echo two-point Dixon technique and its combination with sensitivity encoding for efficient T2-weighted imaging.

    abstract::A fast spin echo two-point Dixon (fast 2PD) technique was developed for efficient T2-weighted imaging with uniform water and fat separation. The technique acquires two interleaved fast spin echo images with water and fat in-phase and 180 degrees out-of-phase, respectively, and generates automatically separate water an...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.005

    authors: Ma J,Son JB,Bankson JA,Stafford RJ,Choi H,Ragan D

    更新日期:2005-12-01 00:00:00

  • Assessment of transplant renal artery stenosis with diffusion-weighted imaging: A preliminary study.

    abstract:OBJECTIVE:To characterize capillary perfusion and tissue diffusion changes in transplant renal artery stenosis (TRAS) with diffusion-weighted imaging (DWI). MATERIALS & METHODS:We retrospectively identified 30 patients with non-contrast enhanced magnetic resonance angiography-proven TRAS. Another 20 kidney transplant ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.05.007

    authors: Fan M,Ni X,Li Y,Chen J,Cheng D,Shi D,He X,Wen J

    更新日期:2019-07-01 00:00:00

  • Test-retest reliability of cerebral blood flow in healthy individuals using arterial spin labeling: Findings from the EMBARC study.

    abstract:INTRODUCTION:Previous investigations of test-retest reliability of cerebral blood flow (CBF) at rest measured with pseudo-continuous Arterial Spin Labeling (pCASL) demonstrated good reliability, but are limited by the use of similar scanner platforms. In the present study we examined test-retest reliability of CBF in r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.09.004

    authors: Almeida JRC,Greenberg T,Lu H,Chase HW,Fournier JC,Cooper CM,Deckersbach T,Adams P,Carmody T,Fava M,Kurian B,McGrath PJ,McInnis MG,Oquendo MA,Parsey R,Weissman M,Trivedi M,Phillips ML

    更新日期:2018-01-01 00:00:00

  • Deep neural network inspired by iterative shrinkage-thresholding algorithm with data consistency (NISTAD) for fast Undersampled MRI reconstruction.

    abstract::With the aim of developing a fast algorithm for high-quality MRI reconstruction from undersampled k-space data, we propose a novel deep neural Network, which is inspired by Iterative Shrinkage Thresholding Algorithm with Data consistency (NISTAD). NISTAD consists of three consecutive blocks: an encoding block, which m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.04.016

    authors: Qiu W,Li D,Jin X,Liu F,Sun B

    更新日期:2020-07-01 00:00:00

  • CPMG relaxation rate dispersion in dipole fields around capillaries.

    abstract::Transverse relaxation rates for Carr-Purcell-Meiboom-Gill (CPMG) sequences increase with inter-echo time in presence of microscopic magnetic field inhomogeneities due to nuclear spin diffusion. For a weak field approximation that includes diffusion effects, the CPMG relaxation rate shift for proton diffusion around ca...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.03.016

    authors: Kurz FT,Kampf T,Buschle LR,Heiland S,Schlemmer HP,Bendszus M,Ziener CH

    更新日期:2016-09-01 00:00:00

  • MRI appearance of disseminated osseous tuberculosis.

    abstract::Disseminated osseous tuberculosis is a rare disease. This is a report of two cases of disseminated osseous tuberculosis imaged with MRI at 1.5-T, CT, plain radiography and bone scintigraphy. CT and plain radiography demonstrated either highly destructive or cystic lesions with sclerotic margins. Bone scintigraphy and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90384-5

    authors: Quinn SF,Murray W,Prochaska J,Cochran C,Clark R

    更新日期:1987-01-01 00:00:00