Different magnetic resonance imaging features in two types of nontraumatic rabbit osteonecrosis models.

Abstract:

:A single injection of high-dose steroid (20 mg/kg) has been reported to induce necrotic lesions in the proximal metaphysis and diaphysis of the rabbit femur. In the rabbit osteonecrosis (ON) model induced by two-dose horse serum injections, contrast-enhanced magnetic resonance imaging (MRI) and T2*-weighted dynamic MRI have been reported to detect necrotic lesions at 3 days after the second serum injection sensitively. The purpose of the present study was to determine whether contrast-enhanced MRI and T2*-weighted dynamic MRI could detect early development of necrotic lesions in the rabbit proximal femora after a single high-dose steroid injection and compare MRI features of the two types of nontraumatic rabbit ON models. We performed nonenhanced MRI, contrast-enhanced MRI and T2*-weighted dynamic MRI of bilateral proximal femora 3 days (10 femora), 1 week (10 femora), 3 weeks (10 femora), 6 weeks (18 femora) and 9 weeks (18 femora) after a single 20 mg/kg steroid injection. Femoral signal intensity of each T2*-weighted dynamic MRI was measured from a 1-cm(2) region of interest in the proximal metaphysis and diaphysis. As a control, MRI was performed in untreated animals (six femora). Histologically, no necrotic lesions were observed in the proximal femora at 3 days and 1 week. Bone marrow necrosis was observed in four (40%) femora at 3 weeks, two (11.1%) femora at 6 weeks and six (33.3%) femora at 9 weeks. Bone marrow lesion completely replaced by granulation tissue was observed in one femur at 6 weeks and one femur at 9 weeks. Histologic evidence of repair tissue surrounding bone marrow necrosis was seen after 6 weeks. Average lesion area including repair tissue was 4.40 mm(2) (range, 0.32 to 20.2 mm(2)). At 9 weeks, contrast-enhanced MRI could detect four (66.7%) femora with bone marrow necrosis of more than 4 mm(2) in the lesion area, while T2*-weighted dynamic images showed a finding of complete ischemia in only one of these four femora. In conclusion, neither contrast-enhanced MRI nor T2*-weighted dynamic MRI could detect early development of necrotic lesions in the single-dose steroid ON model. These results indicated that development of necrotic lesions in the single-dose steroid ON model was not accompanied by as diffuse a femoral hemodynamic change as the two-dose horse serum ON model.

journal_name

Magn Reson Imaging

authors

Takao M,Sugano N,Nishii T,Sakai T,Nakamura N,Yoshikawa H

doi

10.1016/j.mri.2008.07.001

subject

Has Abstract

pub_date

2009-02-01 00:00:00

pages

233-9

issue

2

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(08)00210-5

journal_volume

27

pub_type

杂志文章
  • Area of paradoxical signal drop after the administration of superparamagnetic iron oxide on the T2-weighted image of a patient with lymphangitic metastasis of the liver.

    abstract::We report a geographic area of prominent hypointensity in T2-weighted images vs. normal adjacent liver parenchyma in a patient with cholangiocarcinoma and lymphangitic metastasis of the liver after superparamagnetic iron oxide (SPIO) administration. The area showing this prominent signal drop showed Kupffer cell proli...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.10.012

    authors: Lee Y,Lee JS,Kim CM,Jeong JY,Choi JI,Kim MJ

    更新日期:2008-05-01 00:00:00

  • Using nine degrees-of-freedom registration to correct for changes in voxel size in serial MRI studies.

    abstract::Quantitative longitudinal brain magnetic resonance (MR) studies may be confounded by scanner-related drifts in voxel sizes. Total intracranial volume (TIV) normalisation is commonly used to correct serial cerebral volumetric measurements for these drifts. We hypothesised that automated rigid-body registration of whole...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.057

    authors: Whitwell JL,Schott JM,Lewis EB,MacManus DG,Fox NC

    更新日期:2004-09-01 00:00:00

  • In vivo nuclear magnetic resonance imaging and spectroscopy of aquatic organisms.

    abstract::NMR imaging and localized 1H spectroscopy of a variety of aquatic organisms in vivo is described for the first time. The practical consideration of life support, water volume, salinity, and anesthesia are discussed and solutions presented. Such animal studies shape our understanding of physiology, biochemistry, and bi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90253-x

    authors: Blackband SJ,Stoskopf MK

    更新日期:1990-01-01 00:00:00

  • Effect of anesthesia on the signal intensity in tumors using BOLD-MRI: comparison with flow measurements by Laser Doppler flowmetry and oxygen measurements by luminescence-based probes.

    abstract::BOLD-contrast functional magnetic resonance imaging (MRI) was used to assess the evolution of tumor oxygenation and blood flow after administration of four different anesthetics: pentobarbital (60 mg/kg), ketamine/xylazine (80/8 mg/kg), fentanyl/droperidol (0.078/3.9 mg/kg), and isoflurane (1.5%). Gradient echo sequen...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.02.005

    authors: Baudelet C,Gallez B

    更新日期:2004-09-01 00:00:00

  • Improved sensitivity of MRI in multiple sclerosis by use of extensive standardized procedures.

    abstract::The relative value of two different MRI procedures for the assessment of infratentorial extension in multiple sclerosis (MS) was studied. Multislice spin-echo techniques were used overall. Procedure A consisted of parasagittal T1-weighted images (500/30) and axial T2-weighted images (2500/30, 2500/120). Procedure B co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90547-x

    authors: Van de Vyver FL,Truyen L,Gheuens J,Degryse HR,Peersman GV,Martin JJ

    更新日期:1989-05-01 00:00:00

  • Analysis of microporosity and setting of reactive powder concrete by proton nuclear relaxation.

    abstract::The proton spin-lattice relaxation measured at several frequencies leads to a resolved distribution of four Tli for reactive powder concrete (RPC). The typical Tli frequency dependences are quantitatively interpreted by a biphasic fast exchange model and a proton nuclear relaxation of hydrated paramagnetic ions at the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00063-0

    authors: Philippot S,Korb JP,Petit D,Zanni H

    更新日期:1998-06-01 00:00:00

  • Flexible, phase-matched, linear receive arrays for high-field MRI in monkeys.

    abstract::High signal-to-noise ratios (SNR) are essential for high-resolution anatomical and functional MRI. Phased arrays are advantageous for this but have the drawback that they often have inflexible and bulky configurations. Particularly in experiments where functional MRI is combined with simultaneous electrophysiology, sp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.03.026

    authors: Goense J,Logothetis NK,Merkle H

    更新日期:2010-10-01 00:00:00

  • Semi-adiabatic Shinnar-Le Roux pulses and their application to diffusion tensor imaging of humans at 7T.

    abstract::The adiabatic Shinnar-Le Roux (SLR) algorithm for radiofrequency (RF) pulse design enables systematic control of pulse parameters such as bandwidth, RF energy distribution and duration. Some applications, such as diffusion-weighted imaging (DWI) at high magnetic fields, would benefit from RF pulses that can provide gr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.04.003

    authors: Balchandani P,Qiu D

    更新日期:2014-09-01 00:00:00

  • Evidence for left-right asymmetries in the proton MRS of brain in normal volunteers.

    abstract::Although there is ample evidence in the literature for structural, functional and physiological asymmetries in the two hemispheres of human brain, direct evidence of a similar asymmetry in the in vivo distribution of brain metabolites has been lacking. In this study, the existence of chemical asymmetries in six differ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00342-6

    authors: Jayasundar R,Raghunathan P

    更新日期:1997-01-01 00:00:00

  • Quantitative SENSE-MRSI of the human brain.

    abstract:PURPOSE:To develop a method for estimating metabolite concentrations using phased-array coils and sensitivity-encoded (SENSE) magnetic resonance spectroscopic images (MRSI) of the human brain. MATERIALS AND METHODS:The method is based on the phantom replacement technique and uses receive coil sensitivity maps and body...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.11.003

    authors: Bonekamp D,Smith MA,Zhu H,Barker PB

    更新日期:2010-04-01 00:00:00

  • Radiofrequency magnetic field gradient echoes have reduced sensitivity to susceptibility gradients.

    abstract::The amplitudes of gradient-echoes produced using static field gradients are sensitive to diffusion of tissue water during the echo evolution time. Gradient-echoes have been used to produce MR images in which image intensity is proportional to the self-diffusion coefficient of water. However, such measurements are subj...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00051-h

    authors: Karczmar G,River J,Koretsky AP

    更新日期:1995-01-01 00:00:00

  • Predictability of SNR and reader preference in clinical MR imaging.

    abstract::Fifty-four independent scans were performed in two volunteers covering one anatomic region in each (the brain and knee) with the purpose of ascertaining the agreement between predicted and measured signal-to-noise ratios (SNR). Systematically varied parameters were number of excitations (NEX), field of view (FOV), sec...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90009-q

    authors: Owen RS,Wehrli FW

    更新日期:1990-01-01 00:00:00

  • Partial angle inversion recovery (PAIR) MR imaging: spin-echo and snapshot implementation.

    abstract::The effects of varying the inversion or excitation RF pulse flip angles on image contrast and imaging time have been investigated in IR imaging theoretically, with phantoms and with normal volunteers. Signal intensity in an IR pulse sequence as a function of excitation, inversion and refocusing pulse flip angles was c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90481-e

    authors: Vinitski S,Albert S,Mitchell DG,Tasciyan TA,Rifkin MD

    更新日期:1992-01-01 00:00:00

  • 1H-MRS of the macaque monkey primary visual cortex at 7 T: strategies and pitfalls of shimming at the brain surface.

    abstract::Magnetic resonance spectroscopy (MRS) is ideally suited for physiology-neurochemistry experiments with the living brain and particularly for studies on the primary visual cortex (striate cortex or area V1). Yet, the highly convoluted form of the human V1 has thus far prevented the performance of MRS investigations tha...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.03.008

    authors: Juchem C,Logothetis NK,Pfeuffer J

    更新日期:2007-07-01 00:00:00

  • MRI-guided breast vacuum biopsy: Localization of the lesion without contrast-agent application using diffusion-weighted imaging.

    abstract:OBJECTIVE:In magnetic resonance-guided breast vacuum biopsies, the contrast agent for targeting suspicious lesions can typically be applied only once during an intervention, due to the slow elimination of the gadolinium chelate from the extracellular fluid space. This study evaluated the feasibility of diffusion-weight...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.12.006

    authors: Berger N,Varga Z,Frauenfelder T,Boss A

    更新日期:2017-05-01 00:00:00

  • Liposomal Gd-DTPA: effect of encapsulation on enhancement of hepatoma model by MRI.

    abstract::Liposomes entrapping gadolinium-DTPA (Gd-DTPA) were synthesized from 60 mole percent egg phosphatidylcholine (EPC) and 40 mole percent cholesterol or EPC alone entrapping Gd-DTPA in diameters of 100 and 200 nm. Rats bearing Morris hepatoma in their flanks were imaged by MR pre- and post-contrast with free Gd-DTPA and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90491-8

    authors: Unger EC,MacDougall P,Cullis P,Tilcock C

    更新日期:1989-07-01 00:00:00

  • A new diagnostic approach to vascular rings and pulmonary slings: the role of MRI.

    abstract:UNLABELLED:The conventional diagnostic work-up of a patient suspected of having a vascular cause for stridor, or dysphagia, includes esophagography and bronchoscopy to delineate the abnormal structure without imaging the structure itself. Cine-angiography is regarded as the golden standard, but is not routinely perform...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00245-2

    authors: Beekman RP,Hazekamp MG,Sobotka MA,Meijboom EJ,de Roos A,Staalman CR,Beek FJ,Ottenkamp J

    更新日期:1998-01-01 00:00:00

  • Undifferentiated (embryonal) sarcoma of the liver (USL): MRI findings including dynamic gadolinium enhancement.

    abstract::We report the MR appearance of undifferentiated (embryonal) sarcoma of the liver (USL) in a 13-year-old female who presented with a 1-year history of intermittent abdominal pain, weight loss, and fatigue. The tumor was a large, solitary, well-defined focal mass lesion with multiple cystic spaces, septations, and subst...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.02.003

    authors: Psatha EA,Semelka RC,Fordham L,Firat Z,Woosley JT

    更新日期:2004-07-01 00:00:00

  • Validation of estimated 3D temperature maps during hepatic cryo surgery.

    abstract::A simple model for estimating temperature distribution within the frozen region during cryo ablation was tested for accuracy. Freezing experiments were conducted in both ex vivo and in vivo porcine livers. Temperature was measured during freezing using a fiber-optic temperature sensor. Three-dimensional MR images were...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00389-7

    authors: Samset E,Mala T,Edwin B,Gladhaug I,Søreide O,Fosse E

    更新日期:2001-06-01 00:00:00

  • Free-running simultaneous myocardial T1/T2 mapping and cine imaging with 3D whole-heart coverage and isotropic spatial resolution.

    abstract:PURPOSE:To develop a free-running framework for 3D isotropic simultaneous myocardial T1/T2 mapping and cine imaging. METHODS:Continuous data acquisition with 3D golden angle radial trajectory is used in conjunction with T2 preparation of varying echo times and inversion recovery (IR) pulses to enable simultaneous myoc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.08.008

    authors: Qi H,Bustin A,Cruz G,Jaubert O,Chen H,Botnar RM,Prieto C

    更新日期:2019-11-01 00:00:00

  • Biodegradable cystamine spacer facilitates the clearance of Gd(III) chelates in poly(glutamic acid) Gd-DO3A conjugates for contrast-enhanced MR imaging.

    abstract::Poly(L-glutamic acid) (PGA)-cystamine-[gadolinium (Gd)-DO3A] was prepared in high yield with a high Gd-DO3A conjugation efficiency. Approximately 55% of the carboxylic groups in PGA were loaded with Gd-DO3A via cystamine as the spacer. Cystamine can be readily cleaved by endogenous thiols to release the Gd(III) chelat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.03.009

    authors: Ke T,Feng Y,Guo J,Parker DL,Lu ZR

    更新日期:2006-09-01 00:00:00

  • Sources of functional magnetic resonance imaging signal fluctuations in the human brain at rest: a 7 T study.

    abstract::Signal fluctuations in functional magnetic resonance imaging (fMRI) can result from a number of sources that may have a neuronal, physiologic or instrumental origin. To determine the relative contribution of these sources, we recorded physiological (respiration and cardiac) signals simultaneously with fMRI in human vo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.02.004

    authors: Bianciardi M,Fukunaga M,van Gelderen P,Horovitz SG,de Zwart JA,Shmueli K,Duyn JH

    更新日期:2009-10-01 00:00:00

  • Factors influencing contrast in fast spin-echo MR imaging.

    abstract::Multi-echo pulse sequences for producing T2-weighted images in much reduced imaging times have recently been developed for routine clinical use. A number of recent articles have described the contrast obtained with fast spin-echo (FSE) sequences and have generally indicated that they depict tissues very similarly to c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(92)90001-g

    authors: Constable RT,Anderson AW,Zhong J,Gore JC

    更新日期:1992-01-01 00:00:00

  • Magnetic resonance imaging of soft-tissue tumors: comparison with computed tomography.

    abstract::Twenty-seven patients with soft-tissue tumors were examined with a Picker 0.15-tesla resistive magnet and by computed tomography (CT). In all but one patient, MRI was better than or equal to CT in defining the anatomic extent of the tumor. We could determine whether major vascular structures were engulfed by the tumor...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(85)90398-4

    authors: Weekes RG,Berquist TH,McLeod RA,Zimmer WD

    更新日期:1985-01-01 00:00:00

  • Automated measurement of fat infiltration in the hip abductors from Dixon magnetic resonance imaging.

    abstract:PURPOSE:Intramuscular fat infiltration is a dynamic process, in response to exercise and muscle health, which can be quantified by estimating fat fraction (FF) from Dixon MRI. Healthy hip abductor muscles are a good indicator of a healthy hip and an active lifestyle as they have a fundamental role in walking. The autom...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.06.019

    authors: Belzunce MA,Henckel J,Fotiadou A,Di Laura A,Hart A

    更新日期:2020-10-01 00:00:00

  • Dynamic contrast-enhanced MRI to assess hepatocellular carcinoma response to Transarterial chemoembolization using LI-RADS criteria: A pilot study.

    abstract:PURPOSE:To identify quantitative dynamic contrast-enhanced (DCE)-MRI perfusion parameters indicating tumor response of hepatocellular carcinoma (HCC) to transarterial chemoembolization (TACE). MATERIALS AND METHODS:This prospective pilot study was approved by our institutional review board; written and informed consen...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.mri.2019.06.017

    authors: Thibodeau-Antonacci A,Petitclerc L,Gilbert G,Bilodeau L,Olivié D,Cerny M,Castel H,Turcotte S,Huet C,Perreault P,Soulez G,Chagnon M,Kadoury S,Tang A

    更新日期:2019-10-01 00:00:00

  • Bilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain.

    abstract::Deep brain stimulation (DBS) is used increasingly in the field of movement disorders. The implanted electrodes create not only a prior risk to patient safety during MRI, but also a unique opportunity in the collection of functional MRI data conditioned by direct neural stimulation. We evaluated MRI-related heating for...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.02.007

    authors: Bhidayasiri R,Bronstein JM,Sinha S,Krahl SE,Ahn S,Behnke EJ,Cohen MS,Frysinger R,Shellock FG

    更新日期:2005-05-01 00:00:00

  • Complimentary aspects of diffusion imaging and fMRI: II. Elucidating contributions to the fMRI signal with diffusion sensitization.

    abstract::Tissue water molecules reside in different biophysical compartments. For example, water molecules in the vasculature reside for variable periods of time within arteries, arterioles, capillaries, venuoles and veins, and may be within blood cells or blood plasma. Water molecules outside of the vasculature, in the extrav...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2007.02.006

    authors: Mulkern RV,Haker SJ,Maier SE

    更新日期:2007-07-01 00:00:00

  • Characterisation of wetting heterogeneities in sandstone rocks by MRI.

    abstract::MRI is applied to the visualisation of wetting heterogeneities evidenced by water proton T1 contrast at 0.1 T. Water saturated Fontainebleau sandstone samples were examined either in their original water-wet condition, or after silanation. T1, T2Hahn, and T2CPMG were measured for several porosities. T1 and T2CPMG of h...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91557-1

    authors: Guillot G,Chardaire-Rivière C,Bobroff S,Le Roux A,Roussel JC,Cuiec L

    更新日期:1994-01-01 00:00:00

  • Development of computer-generated phantoms for FMRI software evaluation.

    abstract::Functional magnetic resonance imaging (FMRI) is a major tool for the evaluation of brain function and architecture. It is widely used by physicians, neuroscientists, psychologists and others. In order to process the data collected using FMRI, it is necessary to use post-acquisition processing software that employs mot...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.04.007

    authors: Pickens DR,Li Y,Morgan VL,Dawant BM

    更新日期:2005-06-01 00:00:00