Radiofrequency magnetic field gradient echoes have reduced sensitivity to susceptibility gradients.

Abstract:

:The amplitudes of gradient-echoes produced using static field gradients are sensitive to diffusion of tissue water during the echo evolution time. Gradient-echoes have been used to produce MR images in which image intensity is proportional to the self-diffusion coefficient of water. However, such measurements are subject to error due to the presence of background magnetic field gradients caused by variations in local magnetic susceptibility. These local gradients add to the applied gradients. The use of radiofrequency (RF) gradients to produce gradient-echoes may avoid this problem. The RF magnetic field is orthogonal to the offset field produced by local magnetic susceptibility gradients. Thus, the effect of the local gradients on RF gradient-echo amplitude is small if the RF field is strong enough to minimize resonance offset effects. The effects of susceptibility gradients can be further reduced by storing magnetization longitudinally during the echo evolution period. A water phantom was used to evaluate the effects of background gradients on the amplitudes of RF gradient-echoes. A surface coil was used to produce an RF gradient of between 1.3 and 1.6 gauss/cm. Gradient-echoes were detected with and without a 0.16 gauss/cm static magnetic field gradient applied along the same direction as the RF gradient. The background static field gradient had no significant effect on the decay of RF gradient-echo amplitude as a function of echo evolution time. In contrast, the effect of the background gradient on echoes produced using a 1.6 gauss/cm static field gradient is calculated to be significant. This analysis suggests that RF gradient-echoes can produce MR images in which signal intensity is a function of the self-diffusion coefficient of water, but is not significantly affected by background gradients.

journal_name

Magn Reson Imaging

authors

Karczmar G,River J,Koretsky AP

doi

10.1016/0730-725x(95)00051-h

subject

Has Abstract

pub_date

1995-01-01 00:00:00

pages

791-7

issue

6

eissn

0730-725X

issn

1873-5894

pii

0730-725X(95)00051-H

journal_volume

13

pub_type

杂志文章
  • Quantitative multi-modal functional MRI with blood oxygenation level dependent exponential decays adjusted for flow attenuated inversion recovery (BOLDED AFFAIR).

    abstract::A magnetic resonance imaging (MRI) method is described that allows interleaved measurements of transverse (R(2)(*) and R(2)) and longitudinal (R(1)) relaxation rates of tissue water in conjunction with spin labeling. The image-contrasts are intrinsically blood oxygenation level dependent (BOLD) and cerebral blood flow...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00125-9

    authors: Hyder F,Renken R,Kennan RP,Rothman DL

    更新日期:2000-04-01 00:00:00

  • High-resolution, three-dimensional diffusion-weighted breast imaging using DESS.

    abstract:PURPOSE:To evaluate the use of the double-echo steady-state (DESS) sequence for acquiring high-resolution breast images with diffusion and T2 weighting. MATERIALS AND METHODS:Phantom scans were used to verify the T2 and diffusion weighting of the DESS sequence. Image distortion was evaluated in volunteers by comparing...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.12.014

    authors: Granlund KL,Staroswiecki E,Alley MT,Daniel BL,Hargreaves BA

    更新日期:2014-05-01 00:00:00

  • Perfusion imaging by un-inverted flow-sensitive alternating inversion recovery (UNFAIR).

    abstract::A new pulse sequence for estimating cerebral blood flow called UNFAIR, which uses a combination of sequential hyperbolic secant preparatory pulses, is introduced. This sequence is based on the same generalized conditions as previously introduced inversion recovery techniques except that the spins in the image slice of...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00353-0

    authors: Helpern JA,Branch CA,Yongbi MN,Huang NC

    更新日期:1997-01-01 00:00:00

  • The effects of respiratory CO2 fluctuations in the resting-state BOLD signal differ between eyes open and eyes closed.

    abstract::Resting fluctuations in arterial CO2 (a cerebral vasodilator) are believed to be an important source of low-frequency blood oxygenation level dependent (BOLD) signal fluctuations. In this study we focus on the two commonly used resting-states in functional magnetic resonance imaging experiments, eyes open and eyes clo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.013

    authors: Peng T,Niazy R,Payne SJ,Wise RG

    更新日期:2013-04-01 00:00:00

  • Single-shot-double-echo EPI.

    abstract::Echo planar imaging (EPI) was extended for the acquisition of both, the spin-echo (SE) and the stimulated echo in a stimulated echo sequence after one excitation from thermal equilibrium. The two independent EPI images reflect different states of the transverse magnetization excited and measured almost simultaneously....

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91234-n

    authors: Börnert P,Jensen D

    更新日期:1994-01-01 00:00:00

  • Self-navigated 3D whole-heart MRA for non-enhanced surveillance of thoracic aortic dilation: A comparison to CTA.

    abstract:PURPOSE:To prospectively compare image quality and reliability of a non-contrast, self-navigated 3D whole-heart magnetic resonance angiography (MRA) sequence with contrast-enhanced computed tomography angiography (CTA) for sizing of thoracic aortic aneurysm (TAA). METHODS:Self-navigated 3D whole-heart 1.5 T MRA was pe...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.12.003

    authors: Poskaite P,Pamminger M,Kranewitter C,Kremser C,Reindl M,Reiter G,Piccini D,Dumfarth J,Henninger B,Tiller C,Holzknecht M,Reinstadler SJ,Klug G,Metzler B,Mayr A

    更新日期:2021-02-01 00:00:00

  • Chemical exchange magnetic resonance imaging (CHEMI).

    abstract::Systems investigated with NMR spectroscopy are sometimes heterogeneous with respect to chemical composition, rates of chemical exchange, and other properties influencing magnetic resonance parameters. A method was developed to spatially encode reaction kinetic information and produce NMR images sensitive to chemical e...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90125-7

    authors: McFarland EW,Neuringer LJ,Kushmerick MJ

    更新日期:1988-09-01 00:00:00

  • Voxelwise analysis of diffusion MRI of cervical spinal cord using tract-based spatial statistics.

    abstract::Robust voxelwise analysis using tract-based spatial statistics (TBSS) together with permutation statistical method is standardly used in analyzing diffusion tensor imaging (DTI) of brain. A similar analytical method could be useful when studying DTI of cervical spinal cord. Based on anatomical data of sixty-four healt...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.07.008

    authors: Dostál M,Keřkovský M,Staffa E,Bednařík J,Šprláková-Puková A,Mechl M

    更新日期:2020-11-01 00:00:00

  • Evaluation of solitary pulmonary nodules with dynamic contrast-enhanced MR imaging--a promising technique.

    abstract::The evaluation of a solitary pulmonary nodule (SPN) is one of the most frequently encountered challenges in thoracic radiology. In addition to a "state-of-the-art" evaluation of SPNs with CT and biopsy techniques, recently the assessment of the enhancement characteristics with iodinized contrast agents has shown its p...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02010-q

    authors: Hittmair K,Eckersberger F,Klepetko W,Helbich T,Herold CJ

    更新日期:1995-01-01 00:00:00

  • 7T CEST MRI: A potential imaging tool for the assessment of tumor grade and cell proliferation in breast cancer.

    abstract:OBJECTIVES:To investigate the feasibility of chemical exchange saturation transfer (CEST) MRI in patients with breast carcinomas and possible correlations between magnetization transfer asymmetry (MTRasym) values and histological features, such as tumor grade and the Ki-67 proliferation index. MATERIALS AND METHODS:Ni...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.03.004

    authors: Zaric O,Farr A,Poblador Rodriguez E,Mlynarik V,Bogner W,Gruber S,Asseryanis E,Singer CF,Trattnig S

    更新日期:2019-06-01 00:00:00

  • 3D Slicer as an image computing platform for the Quantitative Imaging Network.

    abstract::Quantitative analysis has tremendous but mostly unrealized potential in healthcare to support objective and accurate interpretation of the clinical imaging. In 2008, the National Cancer Institute began building the Quantitative Imaging Network (QIN) initiative with the goal of advancing quantitative imaging in the con...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.05.001

    authors: Fedorov A,Beichel R,Kalpathy-Cramer J,Finet J,Fillion-Robin JC,Pujol S,Bauer C,Jennings D,Fennessy F,Sonka M,Buatti J,Aylward S,Miller JV,Pieper S,Kikinis R

    更新日期:2012-11-01 00:00:00

  • Regional variations in MR relaxation of hip joint cartilage in subjects with and without femoralacetabular impingement.

    abstract::The objective of this study was to analyze regional variations of magnetic resonance (MR) relaxation times (T1ρ and T2) in hip joint cartilage of healthy volunteers and subjects with femoral acetabular impingement (FAI). Morphological and quantitative images of the hip joints of 12 healthy volunteers and 9 FAI patient...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.01.009

    authors: Subburaj K,Valentinitsch A,Dillon AB,Joseph GB,Li X,Link TM,Vail TP,Majumdar S

    更新日期:2013-09-01 00:00:00

  • Tortuosity measurement and the effects of finite pulse widths on xenon gas diffusion NMR studies of porous media.

    abstract::We have extended the utility of NMR as a technique to probe porous media structure over length scales of approximately 100-2000 microm by using the spin 1/2 noble gas 129Xe imbibed into the system's pore space. Such length scales are much greater than can be probed with NMR diffusion studies of water-saturated porous ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00247-8

    authors: Mair RW,Hürlimann MD,Sen PN,Schwartz LM,Patz S,Walsworth RL

    更新日期:2001-04-01 00:00:00

  • MR imaging findings in recurrent primary osseous Ewing sarcoma.

    abstract::The objective of this study was to determine the value of magnetic resonance (MR) imaging in diagnosing local recurrence of Ewing sarcoma. We retrospectively reviewed radiographs, Tc99m-methylene diphosphonate (MDP) skeletal scintigraphy, computed tomography scans, and MR studies of 11 patients who had local recurrenc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)90079-7

    authors: Kauffman WM,Fletcher BD,Hanna SL,Meyer WH

    更新日期:1994-01-01 00:00:00

  • Probe efficiency improvement with remote and transmission line tuning and matching.

    abstract::In certain nuclear magnetic resonance (NMR) applications in which accessibility to the gantry is limited, performing optimal tuning and matching represents a major problem. Here, we discuss a method of tuning NMR probe circuits and matching their impedances which uses cables with different impedance values. This simpl...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00051-x

    authors: Villa P,Vaquero JJ,Chesnick S,Ruiz-Cabello J

    更新日期:1999-09-01 00:00:00

  • Voxel-Wise Logistic Regression and Leave-One-Source-Out Cross Validation for white matter hyperintensity segmentation.

    abstract::Many algorithms have been proposed for automated segmentation of white matter hyperintensities (WMH) in brain MRI. Yet, broad uptake of any particular algorithm has not been observed. In this work, we argue that this may be due to variable and suboptimal validation data and frameworks, precluding direct comparison of ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.06.009

    authors: Knight J,Taylor GW,Khademi A

    更新日期:2018-12-01 00:00:00

  • Interpretation of restricted diffusion in sandstones with internal field gradients.

    abstract::We report on experiments to characterize internal magnetic field gradients that are caused by magnetic susceptibility differences between the solid phase and the fluids filling the pore space. Our measurements focus on low-field relaxometry of brine and oil in sandstones from various reservoirs around the world. Our r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00287-9

    authors: Appel M,Freeman JJ,Gardner JS,Hirasaki GH,Zhang QG,Shafer JL

    更新日期:2001-04-01 00:00:00

  • Correction of partial volume inaccuracies in quantitative phase contrast MR angiography.

    abstract::The phase difference method of phase contrast MR angiography provides a means of measuring the average velocity in each voxel of an MR scan. When static tissue is present in a voxel containing flow, the measured velocity is not the average velocity of the flow alone, but is lower due to the partial volume effect of th...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91245-r

    authors: Hamilton CA

    更新日期:1994-01-01 00:00:00

  • MR imaging of late onset orbital rhabdomyosarcoma with intracranial extension.

    abstract::Today, patients with alveolar rhabdomyosarcoma have a favorable prognosis with a survival rate of more than 80%, due to modern radiotherapy. However, those patients with secondary meningeal involvement are still afflicted with a mortality rate of 90% unless a different therapeutic approach is taken. We report a case o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90035-c

    authors: Judmaier W,Birbamer G,Buchberger W,Mihatsch T,Lener M,Felber S

    更新日期:1993-01-01 00:00:00

  • Influence of excess ligand on Nephrogenic Systemic Fibrosis associated with nonionic, linear gadolinium-based contrast agents.

    abstract:BACKGROUND:The molecular structure, charge, thermodynamic and kinetic stability are approximately the same for gadodiamide and gadoversetamide, the main substantive difference is that gadodiamide is manufactured with 5% free ligand to form Omniscan® and gadoversetamide with 10% free ligand to form OptiMARK®. PURPOSE:T...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.11.015

    authors: Semelka RC,Prybylski JP,Ramalho M

    更新日期:2019-05-01 00:00:00

  • Synthesis of magnetic gradients for NMR tomography.

    abstract::A numerical method is applied to calculate an optimal distribution of currents in air which generate the magnetic field gradients required to spatially encode the radiofrequency signal in a NMR tomographic experiment. We compare the performances of the gradient circuits for the whole body air-core electromagnet descri...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90242-t

    authors: Mustarelli P,Rudnicki M,Savini A,Savoldi F,Villa M

    更新日期:1990-01-01 00:00:00

  • Active intrahepatic gadolinium extravasation following TIPS.

    abstract::A 31-year-old male patient had a transjugular intrahepatic portal systemic shunt (TIPS) placed for acute Budd-Chiari syndrome secondary to paroxysmal nocturnal hemoglobinuria (PNH). Post-procedure, he was anticoagulated for his underlying paroxysmal nocturnal hemoglobinuria. After 11 days, he complained of upper abdom...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00081-2

    authors: Hasegawa S,Eisenberg LB,Semelka RC

    更新日期:1998-09-01 00:00:00

  • Artifacts in chemical shift selective imaging.

    abstract::The role of susceptibility effects in the production of artifacts in chemical shift images generated by the selective excitation technique is discussed. The effects are demonstrated in images of phantom samples of agarose gels containing small air bubbles. The artifacts can lead to erroneous interpretations, in which ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90022-r

    authors: Pope JM,Walker RR,Kron T

    更新日期:1992-01-01 00:00:00

  • Cortical morphologic changes in recent-onset, drug-naïve idiopathic generalized epilepsy.

    abstract:PURPOSE:Only a few studies have investigated the brain morphology abnormalities in structural MRI in patients with drug-naïve idiopathic generalized epilepsy (IGE) and mainly focused on brain volume changes. In the present study, we aimed to investigate the changes in three morphologic measurement differences including...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.05.035

    authors: Deng DM,Chen LZ,Li YW,Long R,Tang GC,Han FG,Diao XM,Chen HL,Long ZL,Qiu LH

    更新日期:2019-09-01 00:00:00

  • High-resolution gadolinium-enhanced 3D MRA of the infrapopliteal arteries. Lessons for improving bolus-chase peripheral MRA.

    abstract::Peripheral magnetic resonance angiography (MRA) is growing in use. However, methods of performing peripheral MRA vary widely and continue to be optimized, especially for improvement in illustration of infrapopliteal arteries. The main purpose of this project was to identify imaging factors that can improve arterial vi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00531-3

    authors: Hood MN,Ho VB,Foo TK,Marcos HB,Hess SL,Choyke PL

    更新日期:2002-09-01 00:00:00

  • Adaptive total linear least square method for quantification of mean transit time in brain perfusion MRI.

    abstract::Absolute quantification of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) are of great relevance for clinical applications. One of the widely used methods for quantification of these parameters is gamma-variate fitting. Traditional nonlinear regression methods for gamma-variate fit...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00075-4

    authors: Li X,Tian J,Li E,Wang X,Dai J,Ai L

    更新日期:2003-06-01 00:00:00

  • Rapid and recoverable in vivo magnetic resonance imaging of the adult zebrafish at 7T.

    abstract::Increasing scientific interest in the zebrafish as a model organism across a range of biomedical and biological research areas raises the need for the development of in vivo imaging tools appropriate to this subject. Development of the embryonic and early stage forms of the subject can currently be assessed using opti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.10.013

    authors: Merrifield GD,Mullin J,Gallagher L,Tucker C,Jansen MA,Denvir M,Holmes WM

    更新日期:2017-04-01 00:00:00

  • A computer algorithm for the simulation of any nuclear magnetic resonance (NMR) imaging method.

    abstract::More than a dozen Nuclear Magnetic Resonance (NMR) imaging methods have been described using different radio-frequency pulse sequences, magnetic field gradient variations, and data processing. In order to have a theoretical understanding in the most general case, we have conceived a computer program for the simulation...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(84)90065-1

    authors: Bittoun J,Taquin J,Sauzade M

    更新日期:1984-01-01 00:00:00

  • Multi-parametric MRI of the physiology and optics of the in-vivo mouse lens.

    abstract::The optics of the ocular lens are determined by its geometry (shape and volume) and its inherent gradient of refractive index (water to protein ratio), which are in turn maintained by unique cellular physiology known as the lens internal microcirculation system. Previously, magnetic resonance imaging (MRI) has been us...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.04.015

    authors: Muir ER,Pan X,Donaldson PJ,Vaghefi E,Jiang Z,Sellitto C,White TW

    更新日期:2020-07-01 00:00:00

  • The influence of stimulated echoes on contrast in fast spin-echo imaging.

    abstract::Tissue contrast obtained using fast spin-echo (FSE) and conventional spin-echo (SE) sequences is not identical and a number of mechanisms are thought to contribute to these contrast differences. The effect of stimulated echoes has previously been apparently ruled out as a contributing mechanism. Signal-to-noise ratios...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02110-f

    authors: Williams CF,Redpath TW,Smith FW

    更新日期:1996-01-01 00:00:00