The effects of respiratory CO2 fluctuations in the resting-state BOLD signal differ between eyes open and eyes closed.

Abstract:

:Resting fluctuations in arterial CO2 (a cerebral vasodilator) are believed to be an important source of low-frequency blood oxygenation level dependent (BOLD) signal fluctuations. In this study we focus on the two commonly used resting-states in functional magnetic resonance imaging experiments, eyes open and eyes closed, and quantify the degree to which measured spontaneous fluctuations in the partial pressure of end-tidal CO2 (Petco2) relate to BOLD signal time series. A significantly longer latency of BOLD signal changes following Petco2 fluctuations was found in the eyes closed condition compared to with eyes open, which may reveal different intrinsic vascular response delays in CO2 reactivity or an alteration in the net BOLD signal arising from Petco2 fluctuations and altered neural activity with eyes closed. By allowing a spatially varying time delay for the compensation of this temporal difference, a more spatially consistent CO2 correlation map can be obtained. Finally, Granger-causality analysis demonstrated a "causal" relationship between Petco2 and BOLD. The identified dominant Petco2→BOLD directional coupling supports the notion that Petco2 fluctuations are indeed a cause of resting BOLD variance in the majority of subjects.

journal_name

Magn Reson Imaging

authors

Peng T,Niazy R,Payne SJ,Wise RG

doi

10.1016/j.mri.2012.06.013

subject

Has Abstract

pub_date

2013-04-01 00:00:00

pages

336-45

issue

3

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(12)00223-8

journal_volume

31

pub_type

杂志文章
  • Real-time animal functional magnetic resonance imaging and its application to neuropharmacological studies.

    abstract::In pharmacological magnetic resonance imaging (phMRI) with anesthetized animals, there is usually only a single time window to observe the dynamic signal change to an acute drug administration since subsequent drug injections are likely to result in altered response properties (e.g., tolerance). Unlike the block-desig...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.02.020

    authors: Lu H,Yang S,Zuo Y,Demny S,Stein EA,Yang Y

    更新日期:2008-11-01 00:00:00

  • Multispectral analysis of bone lesions in the hands of patients with rheumatoid arthritis.

    abstract::Quantitative measures of rheumatoid arthritis (RA) disease progression can provide valuable tools for evaluation of new treatments during clinical trials. In this study, a novel multispectral (MS) MRI analysis method is presented to quantify changes in bone lesion volume (DeltaBLV) in the hands of RA patients. Image r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.013

    authors: Carano RA,Lynch JA,Redei J,Ostrowitzki S,Miaux Y,Zaim S,White DL,Peterfy CG,Genant HK

    更新日期:2004-05-01 00:00:00

  • Assessment of extravascular extracellular space fraction in human melanoma xenografts by DCE-MRI and kinetic modeling.

    abstract::Tumor aggressiveness and response to therapy are influenced by the extravascular extracellular space fraction (EESF) of the malignant tissue. The EESF may, therefore, be an important prognostic parameter for cancer patients. The aim of this study was to investigate whether gadopentetate dimeglumine (Gd-DTPA)-based dyn...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.06.003

    authors: Benjaminsen IC,Brurberg KG,Ruud EB,Rofstad EK

    更新日期:2008-02-01 00:00:00

  • A nonlinear regularization strategy for GRAPPA calibration.

    abstract::A regularization strategy is described for generalized autocalibrating partially parallel acquisition (GRAPPA) that allows successful calibration using a small number of autocalibration signals (ACS). The approach requires certain nonlinear relationships between the GRAPPA coefficients to be satisfied, which increases...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.05.005

    authors: Bydder M,Jung Y

    更新日期:2009-01-01 00:00:00

  • Ferumoxide-enhanced MRI in patients with colorectal cancer and rising CEA: surgical correlation in early recurrence.

    abstract::The purpose of this study was to evaluate the value of Ferumoxide-enhanced magnetic resonance (MR) imaging in the detection of hepatic metastases in high-risk patients treated for colorectal cancer that have rising CEA. We used 19 patients treated previously for colorectal cancer with rising CEA levels underwent an un...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0730-725x(99)00134-4

    authors: Said B,McCart JA,Libutti SK,Choyke PL

    更新日期:2000-04-01 00:00:00

  • Identification of an optimal threshold for detecting human brown adipose tissue using receiver operating characteristic analysis of IDEAL MRI fat fraction maps.

    abstract:PURPOSE:Lower fat fraction (FF) in brown adipose tissue (BAT) than white adipose tissue (WAT) has been exploited using Dixon-based Magnetic Resonance Imaging (MRI) to differentiate these tissues in rodents, human infants and adults. We aimed to determine whether an optimal FF threshold could be determined to differenti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.04.013

    authors: Jones TA,Wayte SC,Reddy NL,Adesanya O,Dimitriadis GK,Barber TM,Hutchinson CE

    更新日期:2018-09-01 00:00:00

  • Isotropically weighted intravoxel incoherent motion brain imaging at 7T.

    abstract::Perfusion magnetic resonance imaging (MRI) is a promising non-invasive technique providing insights regarding the brain's microvascular architecture in vivo. The scalar perfusion metrics can be used for quantitative diagnostics of various brain abnormalities, in particular, in the stroke cases and tumours. However, co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.11.007

    authors: Maximov II,Vellmer S

    更新日期:2019-04-01 00:00:00

  • Assessing the effect of football play on knee articular cartilage using delayed gadolinium-enhanced MRI of cartilage (dGEMRIC).

    abstract::The prevalence of cartilage lesions is much higher in football athletes than in the general population. Delayed gadolinium-enhanced MRI of cartilage (dGEMRIC) has been shown to quantify regional variations of glycosaminoglycan (GAG) concentrations which is an indicator of early cartilage degeneration. The goal of this...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.01.008

    authors: Wei W,Lambach B,Jia G,Flanigan D,Chaudhari AMW,Wei L,Rogers A,Payne J,Siston RA,Knopp MV

    更新日期:2017-06-01 00:00:00

  • Effects of trabecular bone on marrow relaxation in the tibia.

    abstract::The effects of bone on marrow relaxation in the trabecular volume of the most proximal 3 cm in the left tibia were studied with a RF-spoiled gradient echo MRI protocol on a 1.0 T MR unit. The MR measurements were performed on six healthy volunteers, and repeated within one month in order to assess the precision of the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00159-3

    authors: Fransson A,Grampp S,Imhof H

    更新日期:1999-01-01 00:00:00

  • Evaluation of solitary pulmonary nodules with dynamic contrast-enhanced MR imaging--a promising technique.

    abstract::The evaluation of a solitary pulmonary nodule (SPN) is one of the most frequently encountered challenges in thoracic radiology. In addition to a "state-of-the-art" evaluation of SPNs with CT and biopsy techniques, recently the assessment of the enhancement characteristics with iodinized contrast agents has shown its p...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02010-q

    authors: Hittmair K,Eckersberger F,Klepetko W,Helbich T,Herold CJ

    更新日期:1995-01-01 00:00:00

  • Electric current density imaging of bone by MRI.

    abstract::Current density imaging (CDI) has been shown to be a feasible method to map spatial distribution of electric currents through bone structures and for studying osteoporosis and bone fracture models. For the osteoporosis model, bone sample was moistened in a solution of a sodium salt of ethylendiamintetraacetic acid (ED...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00038-6

    authors: Beravs K,White D,Sersa I,Demsar F

    更新日期:1997-01-01 00:00:00

  • Transdermal water mobility in the presence of electrical fields using MR microscopy.

    abstract::Magnetic resonance microscopy of skin from hairless rats under the influence of electrical fields was conducted for two cases: 1) low voltage constant electrical fields and 2) high-voltage short pulse, electrical fields. Under conditions of the low voltage and low current iontophoresis, i.e., 0 to 20 V, and 0 to 0.5 m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00067-3

    authors: Caban JB,Moerland TS,Gibbs SJ,McFadden L,Locke BR

    更新日期:1999-10-01 00:00:00

  • Diagnosis of suspicious breast lesions using an empirical mathematical model for dynamic contrast-enhanced MRI.

    abstract::The purpose of this study was to test whether an empirical mathematical model (EMM) of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) can distinguish between benign and malignant breast lesions. A modified clinical protocol was used to improve the sampling of contrast medium uptake and washout. T(1)-we...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.10.011

    authors: Fan X,Medved M,Karczmar GS,Yang C,Foxley S,Arkani S,Recant W,Zamora MA,Abe H,Newstead GM

    更新日期:2007-06-01 00:00:00

  • Validation of estimated 3D temperature maps during hepatic cryo surgery.

    abstract::A simple model for estimating temperature distribution within the frozen region during cryo ablation was tested for accuracy. Freezing experiments were conducted in both ex vivo and in vivo porcine livers. Temperature was measured during freezing using a fiber-optic temperature sensor. Three-dimensional MR images were...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00389-7

    authors: Samset E,Mala T,Edwin B,Gladhaug I,Søreide O,Fosse E

    更新日期:2001-06-01 00:00:00

  • Quantitative multi-modal functional MRI with blood oxygenation level dependent exponential decays adjusted for flow attenuated inversion recovery (BOLDED AFFAIR).

    abstract::A magnetic resonance imaging (MRI) method is described that allows interleaved measurements of transverse (R(2)(*) and R(2)) and longitudinal (R(1)) relaxation rates of tissue water in conjunction with spin labeling. The image-contrasts are intrinsically blood oxygenation level dependent (BOLD) and cerebral blood flow...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00125-9

    authors: Hyder F,Renken R,Kennan RP,Rothman DL

    更新日期:2000-04-01 00:00:00

  • Diffusional kurtosis imaging of cingulate fibers in Parkinson disease: comparison with conventional diffusion tensor imaging.

    abstract:OBJECTIVE:The pathological changes in Parkinson disease begin in the brainstem; reach the limbic system and ultimately spread to the cerebral cortex. In Parkinson disease (PD) patients, we evaluated the alteration of cingulate fibers, which comprise part of the limbic system, by using diffusional kurtosis imaging (DKI)...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.06.009

    authors: Kamagata K,Tomiyama H,Motoi Y,Kano M,Abe O,Ito K,Shimoji K,Suzuki M,Hori M,Nakanishi A,Kuwatsuru R,Sasai K,Aoki S,Hattori N

    更新日期:2013-11-01 00:00:00

  • Incidental magnetization transfer contrast in standard multislice imaging.

    abstract::Radio frequency magnetic fields from 5 to 100 kHz off resonance reduce longitudinal magnetization of water in some tissues without affecting the magnetization of simple solutions (Wolff, S.D.; Balaban, R.S. Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo. Magn. Reson. Med. 10:135-144; ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90050-c

    authors: Dixon WT,Engels H,Castillo M,Sardashti M

    更新日期:1990-01-01 00:00:00

  • Fractional amplitude of low-frequency fluctuation changes in monkeys with spinal cord injury: a resting-state fMRI study.

    abstract:PURPOSE:Although functional magnetic resonance imaging (fMRI) has revealed that spinal cord injury (SCI) causes anomalous changes in task-induced brain activation, its effect during the resting state remains unclear. The aim of this study is to explore the changes of the brain resting-state function in non-human primat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.02.001

    authors: Rao JS,Ma M,Zhao C,Zhang AF,Yang ZY,Liu Z,Li XG

    更新日期:2014-06-01 00:00:00

  • Evaluation of intracranial stenoses and aneurysms with accelerated 4D flow.

    abstract::The aim of this study was to evaluate intracranial arterial stenoses and aneurysms with accelerated time-resolved three-dimensional (3D) phase-contrast MRI or 4D flow. The 4D flow technique was utilized to image four normal volunteers, two patients with intracranial stenoses and two patients with intracranial aneurysm...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.042

    authors: Hope TA,Hope MD,Purcell DD,von Morze C,Vigneron DB,Alley MT,Dillon WP

    更新日期:2010-01-01 00:00:00

  • Off-resonance frequency filtered magnetic resonance imaging.

    abstract::One of the main problems with rapid magnetic resonance imaging (MRI) techniques is the artifacts that result from off-resonance effects. The proposed off-resonance frequency filtered MRI (OFF-MRI) method focuses on the elimination of off-resonance components from the image of the observed object. To maintain imaging s...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.12.027

    authors: Medic J,Tomazic S

    更新日期:2010-05-01 00:00:00

  • High resolution simultaneous imaging of intracranial and extracranial arterial wall with improved cerebrospinal fluid suppression.

    abstract:PURPOSE:To develop a technique for three dimensional (3D) high resolution joint imaging of intracranial and extracranial arterial walls with improved cerebrospinal fluid (CSF) suppression and good blood suppression based on T1 weighted sampling perfection with application optimized contrast using different angle evolut...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.08.004

    authors: Zhang L,Zhang N,Wu J,Liu X,Chung YC

    更新日期:2017-12-01 00:00:00

  • Quantitative evaluation of porous media wettability using NMR relaxometry.

    abstract::We propose a new method to determine wettability indices from NMR relaxometry. The new method uses the sensitivity of low field NMR relaxometry to the fluid distribution in oil-water saturated porous media. The model is based on the existence of a surface relaxivity for both oil and water, allowing the determination o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00145-0

    authors: Fleury M,Deflandre F

    更新日期:2003-04-01 00:00:00

  • A fast spin echo two-point Dixon technique and its combination with sensitivity encoding for efficient T2-weighted imaging.

    abstract::A fast spin echo two-point Dixon (fast 2PD) technique was developed for efficient T2-weighted imaging with uniform water and fat separation. The technique acquires two interleaved fast spin echo images with water and fat in-phase and 180 degrees out-of-phase, respectively, and generates automatically separate water an...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.005

    authors: Ma J,Son JB,Bankson JA,Stafford RJ,Choi H,Ragan D

    更新日期:2005-12-01 00:00:00

  • MRI observation of heavy metal transport in aquifer matrices down to sub-mg quantities.

    abstract::In this contribution, we report results from MRI studies of the propagation of heavy metal ions through columns packed with sandy aquifer materials. Both sorption of low concentrations of heavy metal ions from water flowing through the column and the formation of sorption traces produced from initially localized highe...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00166-8

    authors: Nestle N,Baumann T,Wunderlich A,Niessner R

    更新日期:2003-04-01 00:00:00

  • STrategically Acquired Gradient Echo (STAGE) imaging, part II: Correcting for RF inhomogeneities in estimating T1 and proton density.

    abstract:PURPOSE:To develop a method for mapping the B1 transmit (B1t) and B1 receive (B1r) fields from two gradient echo datasets each with a different flip angle and from these two images obtain accurate T1 and proton density (PD) maps of the brain. METHODS:A strategically acquired gradient echo (STAGE) data set is collected...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.10.006

    authors: Wang Y,Chen Y,Wu D,Wang Y,Sethi SK,Yang G,Xie H,Xia S,Haacke EM

    更新日期:2018-02-01 00:00:00

  • Quantitative susceptibility mapping of prostate with separate calculations for water and fat regions for reducing shading artifacts.

    abstract::We propose a novel processing method for reducing shading artifacts in quantitative susceptibility mapping (QSM) for prostate imaging. In the conventional method, calculation errors in the boundary regions between water and fat cause shading artifacts that degrade the image quality for QSM. In the proposed method, wat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.11.006

    authors: Sato R,Shirai T,Soutome Y,Bito Y,Ochi H

    更新日期:2020-02-01 00:00:00

  • Effect of ovariectomy on contrast agent diffusion into lumbar intervertebral disc: a dynamic contrast-enhanced MRI study in female rats.

    abstract:PURPOSE:The purpose was to study the effect of estrogen deficiency on contrast agent diffusion into intervertebral disc in a rat model. MATERIALS AND METHODS:Seven-month-old female Sprague-Dawley rats were used. Fourteen rats had ovariectomy, and nine rats had sham surgery. Magnetic resonance imaging (MRI) of sagittal...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.01.001

    authors: Deng M,Griffith JF,Zhu XM,Poon WS,Ahuja AT,Wang YX

    更新日期:2012-06-01 00:00:00

  • Diffusion pore imaging with generalized temporal gradient profiles.

    abstract::In porous material research, one main interest of nuclear magnetic resonance diffusion (NMR) experiments is the determination of the shape of pores. While it has been a longstanding question if this is in principle achievable, it has been shown recently that it is indeed possible to perform NMR-based diffusion pore im...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.03.027

    authors: Laun FB,Kuder TA

    更新日期:2013-09-01 00:00:00

  • A deep learning approach to estimation of subject-level bias and variance in high angular resolution diffusion imaging.

    abstract::The ability to evaluate empirical diffusion MRI acquisitions for quality and to correct the resulting imaging metrics allows for improved inference and increased replicability. Previous work has shown promise for estimation of bias and variance of generalized fractional anisotropy (GFA) but comes at the price of compu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.03.021

    authors: Hainline AE,Nath V,Parvathaneni P,Schilling KG,Blaber JA,Anderson AW,Kang H,Landman BA

    更新日期:2019-06-01 00:00:00

  • The influence of stimulated echoes on contrast in fast spin-echo imaging.

    abstract::Tissue contrast obtained using fast spin-echo (FSE) and conventional spin-echo (SE) sequences is not identical and a number of mechanisms are thought to contribute to these contrast differences. The effect of stimulated echoes has previously been apparently ruled out as a contributing mechanism. Signal-to-noise ratios...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02110-f

    authors: Williams CF,Redpath TW,Smith FW

    更新日期:1996-01-01 00:00:00