Abstract:
:Tumor aggressiveness and response to therapy are influenced by the extravascular extracellular space fraction (EESF) of the malignant tissue. The EESF may, therefore, be an important prognostic parameter for cancer patients. The aim of this study was to investigate whether gadopentetate dimeglumine (Gd-DTPA)-based dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) can be used to assess the EESF of tumors. Amelanotic human melanoma xenografts (A-07, R-18) were used as preclinical models of human cancer. Images of E.F (E is the initial extraction fraction of Gd-DTPA and F is perfusion) and lambda (the partition coefficient of Gd-DTPA) were obtained by Kety analysis of DCE-MRI data. Our study was based on the hypothesis that lambda is governed by the EESF and is not influenced significantly by microvascular density (MVD) or blood perfusion. To test this hypothesis, we searched for correlations between lambda and E.F, MVD or EESF by comparing lambda images with E.F images, histological preparations from the imaged tissue and the radial heterogeneity in EESF obtained by invasive imaging. Positive correlations were found between lambda and EESF. Thus, median lambda was larger in A-07 tumors than in R-18 tumors by a factor of 4.2 (P<.00001), consistent with the histological observation that EESF is approximately fourfold larger in A-07 tumors than in R-18 tumors. The radial heterogeneity in lambda in A-07 and R-18 tumors was almost identical to the radial heterogeneity in EESF. Moreover, lambda was larger in tissue regions with high EESF than in tissue regions with low EESF in A-07 tumors (P=.048). On the other hand, significant correlations between lambda and MVD or E.F could not be detected. Consequently, Kety analysis of Gd-DTPA-based DCE-MRI series of xenografted tumors provides lambda images that primarily reflect the EESF of the tissue.
journal_name
Magn Reson Imagingjournal_title
Magnetic resonance imagingauthors
Benjaminsen IC,Brurberg KG,Ruud EB,Rofstad EKdoi
10.1016/j.mri.2007.06.003subject
Has Abstractpub_date
2008-02-01 00:00:00pages
160-70issue
2eissn
0730-725Xissn
1873-5894pii
S0730-725X(07)00307-4journal_volume
26pub_type
杂志文章abstract::Cross-terms between imaging and diffusion gradients, unaccounted for during tensor calculations, can lead to erroneous estimation of diffusivity and fractional anisotropy (FA) in regions of isotropic and anisotropic diffusion. Cross-term of magnitude 136.8±1.6 s/mm(2), artificially introduced in the slice-encode direc...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2012.02.021
更新日期:2012-07-01 00:00:00
abstract::A new method for generating diffusion contrast in magnetic resonance imaging is presented. This technique is robust enough to allow implementation on conventional imaging systems without hardware modifications. Results from phantom measurements are reported. Qualitative contrast changes in magnetic resonance images de...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(93)90069-p
更新日期:1993-01-01 00:00:00
abstract:PURPOSE:The purpose of this study was to determine the pre- and postpubertal 1H magnetic resonance spectroscopic characteristics of the normal testis to establish baseline values for further clinical studies. MATERIALS AND METHODS:The subjects consisted of male volunteers, of whom 19 were prepubertal with ages between...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2007.06.008
更新日期:2008-02-01 00:00:00
abstract::Magnetic resonance imaging (MRI) is a completely noninvasive modality that has shown significant promise for the evaluation of the cardiovascular system. Our imaging technique employed electrocardiographic (ECG) gating, which resulted in well-resolved images of the cardiac structures. Patients and animals with a varie...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(84)90002-x
更新日期:1984-01-01 00:00:00
abstract::In this work an interleaved multiple-gradient-echo chemical shift imaging (IMGE-CSI) technique was designed, implemented and evaluated at 1.5 and 4T for high-resolution lipid quantification and R(2)* measurement in-vivo. The method is analogous to echo planar CSI but utilizes conventional gradient echoes, exploiting t...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(00)00165-x
更新日期:2000-09-01 00:00:00
abstract::Magnetic resonance imaging (MRI) and spectroscopy (MRS) have contributed considerably to clinical radiology, and a variety of MR techniques have been developed to evaluate pathological processes as well as normal tissue biology at the cellular and molecular level. However, in comparison to nuclear imaging, MRI has rel...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.12.008
更新日期:2017-05-01 00:00:00
abstract::Until recently, NMR imaging with intermolecular multiple-quantum coherences (iMQCs) has been based on the acquisition of a single echo. In vivo studies of iMQC image contrast would greatly benefit from a method that could acquire several orders of quantum coherence during the same acquisition. This would enable compar...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2004.10.019
更新日期:2004-12-01 00:00:00
abstract:PURPOSE:To systematically investigate the scan-rescan, intra-observer, and inter-observer reproducibility of an improved DANTE-SPACE sequence for the simultaneous assessment of intra- and extracranial arterial vessel wall morphology. MATERIALS AND METHODS:Thirty-five healthy volunteers and 10 patients with atheroscler...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.04.016
更新日期:2019-10-01 00:00:00
abstract::Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is often used to examine vascular function in malignant tumors and noninvasively monitor drug efficacy of antivascular therapies in clinical studies. However, complex numerical methods used to derive tumor physiological properties from DCE-MRI images can b...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2012.09.007
更新日期:2013-05-01 00:00:00
abstract::We studied the effect of hydralazine on tumor blood volume fraction and microvascular random flow velocity magnitude by IVIM weighted MRI in conjunction with dynamic Gd-DTPA-Albumin enhanced MRI. Blood volume fraction maps were obtained from the dynamic Gd-DTPA-Albumin enhanced MRI measurements. The average blood volu...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(01)00431-3
更新日期:2001-10-01 00:00:00
abstract::Water content is the dominant chemical compound in the brain and it is the primary determinant of tissue contrast in magnetic resonance (MR) images. Water content varies greatly between individuals, and it changes dramatically over time from birth through senescence of the human life span. We hypothesize that the effe...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2013.07.017
更新日期:2013-12-01 00:00:00
abstract:OBJECTIVE:To perform non-enhanced (NE) magnetic resonance imaging (MRI) of the small bowel at 7 Tesla (7T) and to compare it with 1.5 Tesla (1.5T). MATERIAL AND METHODS:Twelve healthy subjects were prospectively examined using a 1.5T and 7T MRI system. Coronal and axial true fast imaging with steady-state precession (...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2015.11.012
更新日期:2016-06-01 00:00:00
abstract:PURPOSE:To provide a single open-source platform for comprehensive MR algorithm development inclusive of simulations, pulse sequence design and deployment, reconstruction, and image analysis. METHODS:We integrated the "Pulseq" platform for vendor-independent pulse programming with Graphical Programming Interface (GPI)...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2018.03.008
更新日期:2018-10-01 00:00:00
abstract::We determined whether the accuracy of magnetic resonance angiography (MRA) in the peripheral run-off vessels can be improved by using contrast-enhanced (CE) three-dimensional (3D) technique in comparison to electrocardiograph (ECG)-triggered two-dimensional (2D) time-of-flight (TOF) technique. In a prospective study 2...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(98)00078-2
更新日期:1998-10-01 00:00:00
abstract::A four-channel Tic-Tac-Toe (TTT) transmit RF coil was designed and constructed for foot and ankle imaging at 7T MRI. Numerical simulations using an in-house developed FDTD package and experimental analyses using a homogenous phantom show an excellent agreement in terms of B1+ field distribution and s-parameters. Simul...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2017.09.005
更新日期:2018-01-01 00:00:00
abstract::Disseminated osseous tuberculosis is a rare disease. This is a report of two cases of disseminated osseous tuberculosis imaged with MRI at 1.5-T, CT, plain radiography and bone scintigraphy. CT and plain radiography demonstrated either highly destructive or cystic lesions with sclerotic margins. Bone scintigraphy and ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(87)90384-5
更新日期:1987-01-01 00:00:00
abstract::The successful use of magnetic resonance imaging (MRI) of a moldic fossil dicynodont from the Permian aeolian Hopeman Sandstone Formation of Elgin, Scotland, UK, provides paleontologists with a nondestructive technique for examining fossils preserved in this fashion. For large moldic fossils, medical scanners such as ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2003.09.006
更新日期:2004-02-01 00:00:00
abstract:PURPOSE:To establish an optimized sequence design for fast acceleration of arterial spin labeling (ASL)-based time-resolved magnetic resonance angiography (MRA) by acquisition of control and labeled images in the same shot (fast ACTRESS) and a scan time of <1min, for the evaluation of intracranial vessels. MATERIALS A...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2017.07.026
更新日期:2017-11-01 00:00:00
abstract::We report initial NMR studies of continuous flow laser-polarized xenon gas, both in unrestricted tubing, and in a model porous media. The study uses Pulsed Gradient Spin Echo-based techniques in the gas-phase, with the aim of obtaining more sophisticated information than just translational self-diffusion coefficients....
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(03)00156-5
更新日期:2003-04-01 00:00:00
abstract::The purpose of this study was to evaluate the effect of gadoxetic acid (Gd-EOB-DTPA) on measurements of liver stiffness by using magnetic resonance elastography (MRE). In this study, 104 consecutive patients (mean age, 67.7±9.4 years) underwent MRE using a 1.5-T MR scanner equipped with a cylindrical passive driver th...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2011.08.005
更新日期:2012-01-01 00:00:00
abstract::Increased bone water content resulting from repetitive patellofemoral joint overloading has been suggested to be a possible mechanism underlying patellofemoral pain (PFP). To date, it remains unknown whether persons with PFP exhibit elevated bone water content. The purpose of this study was to determine whether recrea...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2014.04.018
更新日期:2014-09-01 00:00:00
abstract::In the present work, we reported a new nuclear Overhauser enhancement (NOE)-mediated magnetization transfer (MT) signal at around -1.6ppm (NOE(-1.6)) in rat brain and investigated its application in the detection of acute ischemic stroke in rodent model. Using continuous wave (CW) MT sequence, the NOE(-1.6) is reliabl...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.05.002
更新日期:2016-10-01 00:00:00
abstract::The purpose of this study is to illustrate motion correction in Musculoskeletal (MSK) Magnetic Resonance Imaging (MRI) through utilization of information from an optical tracker to capture the extent and instant of motion. A Digital Single Lens Reflexive camera is employed as the optical tracker to capture the extent ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2017.12.031
更新日期:2018-05-01 00:00:00
abstract::The apparent diffusion coefficient (ADC) measured using magnetic resonance imaging methods provides information on microstructural properties of biological tissues, and thus has found applications as a useful biomarker for assessing changes such as those that occur in ischemic stroke and cancer. Conventional pulsed gr...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2010.10.002
更新日期:2011-04-01 00:00:00
abstract:PURPOSE:To develop a protocol to non-invasively measure and map fat fraction, fat/(fat+water), as a function of age in the adult thymus for future studies monitoring the effects of interventions aimed at promoting thymic rejuvenation and preservation of immunity in older adults. MATERIALS AND METHODS:Three-dimensional...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2018.03.016
更新日期:2018-07-01 00:00:00
abstract:PURPOSE:To evaluate the application of high-resolution MRI methodology for characterizing the fluid velocity field and evaluate fluid shear field within a simplified in vitro model of a bone-implant interface. MATERIALS AND METHODS:The study used a specific micromotion canine bone implant that has been used for over a...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2005.11.001
更新日期:2006-06-01 00:00:00
abstract:INTRODUCTION:Previous investigations of test-retest reliability of cerebral blood flow (CBF) at rest measured with pseudo-continuous Arterial Spin Labeling (pCASL) demonstrated good reliability, but are limited by the use of similar scanner platforms. In the present study we examined test-retest reliability of CBF in r...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2017.09.004
更新日期:2018-01-01 00:00:00
abstract::Quantitative analysis has tremendous but mostly unrealized potential in healthcare to support objective and accurate interpretation of the clinical imaging. In 2008, the National Cancer Institute began building the Quantitative Imaging Network (QIN) initiative with the goal of advancing quantitative imaging in the con...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2012.05.001
更新日期:2012-11-01 00:00:00
abstract::Arterial spin labeling (ASL) perfusion fMRI data differ in important respects from the more familiar blood oxygen level-dependent (BOLD) fMRI data and require specific processing strategies. In this paper, we examined several factors that may influence ASL data analysis, including data storage bit resolution, motion c...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2007.07.003
更新日期:2008-02-01 00:00:00
abstract::We retrospectively compared the diagnostic accuracy of abdominal ultrasound (US), computed tomography (CT), and magnetic resonance imaging (MRI) studies performed on the same individual to determine the relative performance of these modalities in the evaluation of disease processes, arising from different intra-abdomi...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2003.01.001
更新日期:2004-01-01 00:00:00