High-resolution, three-dimensional diffusion-weighted breast imaging using DESS.

Abstract:

PURPOSE:To evaluate the use of the double-echo steady-state (DESS) sequence for acquiring high-resolution breast images with diffusion and T2 weighting. MATERIALS AND METHODS:Phantom scans were used to verify the T2 and diffusion weighting of the DESS sequence. Image distortion was evaluated in volunteers by comparing DESS images and conventional diffusion-weighted images (DWI) to spoiled gradient-echo images. The DESS sequence was added to a standard clinical protocol, and the resulting patient images were used to evaluate overall image quality and image contrast in lesions. RESULTS:The diffusion weighting of the DESS sequence can be easily modulated by changing the spoiler gradient area and flip angle. Radiologists rated DESS images as having higher resolution and less distortion than conventional DWI. Lesion-to-tissue contrast ratios are strongly correlated between DWI and DESS images (R=0.83) and between T2-weighted fast spin-echo and DESS images (R=0.80). CONCLUSION:The DESS sequence is able to acquire high-resolution 3D diffusion- and T2-weighted images in short scan times, with image quality that facilitates morphological assessment of lesions.

journal_name

Magn Reson Imaging

authors

Granlund KL,Staroswiecki E,Alley MT,Daniel BL,Hargreaves BA

doi

10.1016/j.mri.2013.12.014

subject

Has Abstract

pub_date

2014-05-01 00:00:00

pages

330-41

issue

4

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(13)00420-7

journal_volume

32

pub_type

杂志文章
  • Cardiovascular applications of magnetic resonance imaging.

    abstract::Magnetic resonance imaging (MRI) is a completely noninvasive modality that has shown significant promise for the evaluation of the cardiovascular system. Our imaging technique employed electrocardiographic (ECG) gating, which resulted in well-resolved images of the cardiac structures. Patients and animals with a varie...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(84)90002-x

    authors: McNamara MT,Higgins CB

    更新日期:1984-01-01 00:00:00

  • A case of Budd-Chiari syndrome: Gd-EOB-DTPA-enhanced MR findings.

    abstract::Budd-Chiari syndrome (BCS) is a rare disorder caused by the obstruction of hepatic venous outflow, leading to sinusoidal congestion, ischemic injury to liver cells and portal hypertension. Long-term survival largely depends on whether hepatocellular carcinoma occurs. A recently available liver-specific contrast medium...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.10.013

    authors: Kitajima K,Yoshikawa T,Seo Y,Ohno Y,Yano Y,Miki A,Kanda T,Kanata N,Azuma T,Sugimura K

    更新日期:2011-05-01 00:00:00

  • Assessment of the anomalous pulmonary circulation by dynamic contrast-enhanced MR angiography in under four seconds.

    abstract::The purpose of this study was to demonstrate the initial results of the dynamic contrast-enhanced MRA in under four seconds in the assessment of anomalous pulmonary circulation. We performed dynamic contrast enhanced MRA on ten patients with a temporal resolution of 2-3 sec for each phase. Five patients had pulmonary ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00634-3

    authors: Balci NC,Yalçin Y,Tunaci A,Balci Y

    更新日期:2003-01-01 00:00:00

  • Idiopathic dilatation of the pulmonary artery: report of four cases.

    abstract::Idiopathic dilatation of the pulmonary artery (IDPA) is a rare congenital disease which is usually detected fortuitously on chest x-ray, thus radiologists must be aware of this clinical entity. This report describes four cases to which Magnetic Resonance Imaging (MRI) played a major role in diagnosing IDPA and in dete...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00013-2

    authors: Ugolini P,Mousseaux E,Sadou Y,Sidi D,Mercier LA,Paquet E,Gaux JC

    更新日期:1999-07-01 00:00:00

  • Free-running simultaneous myocardial T1/T2 mapping and cine imaging with 3D whole-heart coverage and isotropic spatial resolution.

    abstract:PURPOSE:To develop a free-running framework for 3D isotropic simultaneous myocardial T1/T2 mapping and cine imaging. METHODS:Continuous data acquisition with 3D golden angle radial trajectory is used in conjunction with T2 preparation of varying echo times and inversion recovery (IR) pulses to enable simultaneous myoc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.08.008

    authors: Qi H,Bustin A,Cruz G,Jaubert O,Chen H,Botnar RM,Prieto C

    更新日期:2019-11-01 00:00:00

  • Evaluation of solitary pulmonary nodules with dynamic contrast-enhanced MR imaging--a promising technique.

    abstract::The evaluation of a solitary pulmonary nodule (SPN) is one of the most frequently encountered challenges in thoracic radiology. In addition to a "state-of-the-art" evaluation of SPNs with CT and biopsy techniques, recently the assessment of the enhancement characteristics with iodinized contrast agents has shown its p...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02010-q

    authors: Hittmair K,Eckersberger F,Klepetko W,Helbich T,Herold CJ

    更新日期:1995-01-01 00:00:00

  • A preliminary study of blood-oxygen-level-dependent MRI in patients with chronic kidney disease.

    abstract:BACKGROUND:Blood-oxygen-level-dependent (BOLD) magnetic resonance imaging (MRI) can provide regional measurements of oxygen content using deoxyhemoglobin paramagnetic characteristics. The apparent relaxation rate or R2*(=1/T2*) can be determined from the slope of log (intensity) versus echo time and is directly proport...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.10.003

    authors: Xin-Long P,Jing-Xia X,Jian-Yu L,Song W,Xin-Kui T

    更新日期:2012-04-01 00:00:00

  • Quantitative magnetic resonance imaging of 'Fuyu' persimmon fruit during development and ripening.

    abstract::Qualitative and quantitative proton magnetic resonance imaging techniques were applied to persimmon (Diospyros kaki cv 'Fuyu') fruit during development and post-harvest ripening. Spin-lattice (T(1)) relaxation times in mesocarp parenchyma and vascular tissue exhibited a sigmoidal pattern of increase leading to commerc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00082-1

    authors: Clark CJ,MacFall JS

    更新日期:2003-07-01 00:00:00

  • Can preoperative diffusion-weighted MRI predict postoperative hepatic insufficiency after curative resection of HBV-related hepatocellular carcinoma? A pilot study.

    abstract::Liver fibrosis determines the functional liver reserve. Several studies have reported that the apparent diffusion coefficient (ADC) values of diffusion-weighted magnetic resonance imaging (DW-MRI) can assess liver fibrosis. We investigated whether DW-MRI predicts postoperative hepatic insufficiency and liver fibrosis ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.03.018

    authors: Kim SU,Kim YC,Choi JS,Kim KS,Choi GH,Choi JS,Park JY,Kim DY,Ahn SH,Choi EH,Park YN,Chon CY,Han KH,Kim MJ

    更新日期:2010-07-01 00:00:00

  • 7T GRE-MRI signal compartments are sensitive to dysplastic tissue in focal epilepsy.

    abstract::Ultra-high field magnetic resonance imaging data obtained using a multi-echo gradient echo sequence has been shown to contain information on tissue microstructure. Quantitative assessment of water fraction, relaxation time and frequency shift using multi-compartment signal modelling may help improve our understanding ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.05.011

    authors: Thapaliya K,Urriola J,Barth M,Reutens DC,Bollmann S,Vegh V

    更新日期:2019-09-01 00:00:00

  • Increasing mean airway pressure reduces functional MRI (fMRI) signal in the primary visual cortex.

    abstract::Changes in both blood flow and blood oxygenation determine the functional MRI (fMRI) signal. In the present study factors responsible for blood oxygenation (e.g., FiO(2)) were held constant so that changes in pixel count would above all reflect changes in regional cerebral blood flow (rCBF). Continuous positive airway...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00229-0

    authors: Lorenz IH,Kolbitsch C,Hörmann C,Schocke M,Kremser C,Zschiegner F,Felber S,Benzer A

    更新日期:2001-01-01 00:00:00

  • Undersampled MRI reconstruction with patch-based directional wavelets.

    abstract::Compressed sensing has shown great potential in reducing data acquisition time in magnetic resonance imaging (MRI). In traditional compressed sensing MRI methods, an image is reconstructed by enforcing its sparse representation with respect to a preconstructed basis or dictionary. In this paper, patch-based directiona...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.02.019

    authors: Qu X,Guo D,Ning B,Hou Y,Lin Y,Cai S,Chen Z

    更新日期:2012-09-01 00:00:00

  • Paradoxical parasellar high signals resembling shunt diseases on routine 3D time-of-flight MR angiography of the brain: mechanism for the signals and differential diagnosis from shunt diseases.

    abstract:BACKGROUND AND PURPOSE:We occasionally encounter phenomena in which venous flow signals of the cavernous sinus (CS) and/or inferior petrosal sinus (IPS) are visualized paradoxically in patients without arteriovenous shunt in 3D time-of-flight magnetic resonance angiography (3D-TOF MRA) of the brain. The aims of this st...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.08.004

    authors: Sakamoto M,Taoka T,Iwasaki S,Nakagawa H,Fukusumi A,Takayama K,Wada T,Kichikawa K

    更新日期:2004-11-01 00:00:00

  • Trajectory correction for free-breathing radial cine MRI.

    abstract::Radial acquisitions can suffer from trajectory errors leading to reduced image quality. Here we present a new method of trajectory correction that uses all spokes of a radial acquisition and compare it to an existing method that uses a two-spoke pre-scan calibration. For both methods, estimates of the necessary shifts...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.04.006

    authors: Buonincontri G,Methner C,Krieg T,Carpenter TA,Sawiak SJ

    更新日期:2014-09-01 00:00:00

  • Summary of special issue on gadolinium bioeffects and toxicity with a look to the future.

    abstract::This summary attempts to provide forward-looking concepts regarding gadolinium related toxicity, as discussed in further detail in this issue. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2016.09.002

    authors: Semelka RC,Ramalho M,Jay M

    更新日期:2016-12-01 00:00:00

  • Visualization of Taylor-Couette and spiral Poiseuille flows using a snapshot FLASH spatial tagging sequence.

    abstract::A new magnetic resonance imaging technique was applied to the Taylor-Couette and spiral Poiseuille (Taylor-Couette with superposed mean axial flux) flows for the first time. The experimental technique is a combination of spatial tagging methods and a snapshot FLASH imaging sequence, which allows the full-field visuali...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00121-6

    authors: Moser KW,Raguin LG,Harris A,Morris HD,Georgiadis J,Shannon M,Philpott M

    更新日期:2000-02-01 00:00:00

  • MRI inter-slice reconstruction using super-resolution.

    abstract::MRI reconstruction using super-resolution is presented and shown to improve spatial resolution in cases when spatially-selective RF pulses are used for localization. In 2-D multislice MRI, the resolution in the slice direction is often lower than the in-plane resolution. For certain diagnostic imaging applications, is...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00511-8

    authors: Greenspan H,Oz G,Kiryati N,Peled S

    更新日期:2002-06-01 00:00:00

  • Comparison between end-tidal CO₂ and respiration volume per time for detecting BOLD signal fluctuations during paced hyperventilation.

    abstract::Respiratory motion and capnometry monitoring were performed during blood oxygen level-dependent (BOLD) functional magnetic resonance imaging (fMRI) of the brain while a series of paced hyperventilation tasks were performed that caused significant hypocapnia. Respiration volume per time (RVT) and end-tidal carbon dioxi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.07.011

    authors: Vogt KM,Ibinson JW,Schmalbrock P,Small RH

    更新日期:2011-11-01 00:00:00

  • Pulsed arterial spin labeling perfusion imaging at 3 T: estimating the number of subjects required in common designs of clinical trials.

    abstract::Pulsed arterial spin labeling (PASL) is an increasingly common technique for noninvasively measuring cerebral blood flow (CBF) and has previously been shown to have good repeatability. It is likely to find a place in clinical trials and in particular the investigation of pharmaceutical agents active in the central ner...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.02.030

    authors: Murphy K,Harris AD,Diukova A,Evans CJ,Lythgoe DJ,Zelaya F,Wise RG

    更新日期:2011-12-01 00:00:00

  • Improved sensitivity of MRI in multiple sclerosis by use of extensive standardized procedures.

    abstract::The relative value of two different MRI procedures for the assessment of infratentorial extension in multiple sclerosis (MS) was studied. Multislice spin-echo techniques were used overall. Procedure A consisted of parasagittal T1-weighted images (500/30) and axial T2-weighted images (2500/30, 2500/120). Procedure B co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90547-x

    authors: Van de Vyver FL,Truyen L,Gheuens J,Degryse HR,Peersman GV,Martin JJ

    更新日期:1989-05-01 00:00:00

  • Towards quantitative evaluation of wall shear stress from 4D flow imaging.

    abstract::Wall shear stress (WSS) is a relevant hemodynamic indicator of the local stress applied on the endothelium surface. More specifically, its spatiotemporal distribution reveals crucial in the evolution of many pathologies such as aneurysm, stenosis, and atherosclerosis. This paper introduces a new solution, called PaLMA...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.08.017

    authors: Levilly S,Castagna M,Idier J,Bonnefoy F,Le Touzé D,Moussaoui S,Paul-Gilloteaux P,Serfaty JM

    更新日期:2020-12-01 00:00:00

  • Error propagation model for microscopic magnetic resonance elastography shear-wave images.

    abstract::Microscopic magnetic resonance elastography is a high-resolution method for visualizing shear waves and assessing the biomechanical viscoelastic properties of small biological samples. In this work, we used error propagation to develop a simple analytical model that relates the signal-to-noise ratio of MR magnitude im...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.09.040

    authors: Othman SF,Zhou XJ,Xu H,Royston TJ,Magin RL

    更新日期:2007-01-01 00:00:00

  • CPMG relaxation rate dispersion in dipole fields around capillaries.

    abstract::Transverse relaxation rates for Carr-Purcell-Meiboom-Gill (CPMG) sequences increase with inter-echo time in presence of microscopic magnetic field inhomogeneities due to nuclear spin diffusion. For a weak field approximation that includes diffusion effects, the CPMG relaxation rate shift for proton diffusion around ca...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.03.016

    authors: Kurz FT,Kampf T,Buschle LR,Heiland S,Schlemmer HP,Bendszus M,Ziener CH

    更新日期:2016-09-01 00:00:00

  • Undifferentiated (embryonal) sarcoma of the liver (USL): MRI findings including dynamic gadolinium enhancement.

    abstract::We report the MR appearance of undifferentiated (embryonal) sarcoma of the liver (USL) in a 13-year-old female who presented with a 1-year history of intermittent abdominal pain, weight loss, and fatigue. The tumor was a large, solitary, well-defined focal mass lesion with multiple cystic spaces, septations, and subst...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.02.003

    authors: Psatha EA,Semelka RC,Fordham L,Firat Z,Woosley JT

    更新日期:2004-07-01 00:00:00

  • A simple method for MR elastography: a gradient-echo type multi-echo sequence.

    abstract::To demonstrate the feasibility of a novel MR elastography (MRE) technique based on a conventional gradient-echo type multi-echo MR sequence which does not need additional bipolar magnetic field gradients (motion encoding gradient: MEG), yet is sensitive to vibration. In a gradient-echo type multi-echo MR sequence, sev...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.10.002

    authors: Numano T,Mizuhara K,Hata J,Washio T,Homma K

    更新日期:2015-01-01 00:00:00

  • Effects of apodization smoothing and denoising on spectral fitting.

    abstract:PURPOSE:Visual review of individual spectra in magnetic resonance spectroscopic imaging (MRSI) data benefits from the application of spectral smoothing; however, if this processing step is applied prior to spectral analysis this can impact the accuracy of the quantitation. This study aims to analyze the effect of spect...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.04.013

    authors: Goryawala M,Sullivan M,Maudsley AA

    更新日期:2020-07-01 00:00:00

  • Non-contrast MR Lymphography of lipedema of the lower extremities.

    abstract:AIM:To assess imaging findings and characteristics of the lymphatic system in patients affected by lipedema and lipolymphedema of the lower extremities on Non-Contrast MR Lymphography (NCMRL). MATERIALS AND METHODS:44 lower extremities in 11 consecutive female patients affected by lipedema, and 11 patients with lipoly...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.06.010

    authors: Cellina M,Gibelli D,Soresina M,Menozzi A,Martinenghi C,Panzeri M,Oliva G

    更新日期:2020-09-01 00:00:00

  • Skeletal muscle lymphoma: MRI evaluation.

    abstract::The magnetic resonance imaging (MRI) features of two cases of malignant lymphoproliferative disease involving skeletal muscle are presented. In both cases involved muscles were quantitatively and subjectively hypointense to fat on T1-weighted spin echo images, hypointense or isointense on T2-weighted spin echo images,...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90522-2

    authors: Metzler JP,Fleckenstein JL,Vuitch F,Frenkel EP

    更新日期:1992-01-01 00:00:00

  • Applications of controlled-flow laser-polarized xenon gas to porous and granular media study.

    abstract::We report initial NMR studies of continuous flow laser-polarized xenon gas, both in unrestricted tubing, and in a model porous media. The study uses Pulsed Gradient Spin Echo-based techniques in the gas-phase, with the aim of obtaining more sophisticated information than just translational self-diffusion coefficients....

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00156-5

    authors: Mair RW,Wang R,Rosen MS,Candela D,Cory DG,Walsworth RL

    更新日期:2003-04-01 00:00:00

  • Optimized 3D bright blood MRI of aortic plaque at 3 T.

    abstract:PURPOSE:To evaluate the feasibility of an optimized bright blood MRI protocol at 3 T in combination with contrast agent administration for the detection and characterization of aortic high-risk plaques for the improved workup of acute stroke patients. MATERIALS AND METHODS:ECG synchronized T1-weighted 3D gradient echo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.08.010

    authors: Markl M,Dudler P,Fydrychowicz A,Strecker C,Weiller C,Hennig J,Harloff A

    更新日期:2008-04-01 00:00:00