Pulsed arterial spin labeling perfusion imaging at 3 T: estimating the number of subjects required in common designs of clinical trials.

Abstract:

:Pulsed arterial spin labeling (PASL) is an increasingly common technique for noninvasively measuring cerebral blood flow (CBF) and has previously been shown to have good repeatability. It is likely to find a place in clinical trials and in particular the investigation of pharmaceutical agents active in the central nervous system. We aimed to estimate the sample sizes necessary to detect regional changes in CBF in common types of clinical trial design including (a) between groups, (b) a two-period crossover and (3) within-session single dosing. Whole brain CBF data were acquired at 3 T in two independent groups of healthy volunteers at rest; one of the groups underwent a repeat scan. Using these data, we were able to estimate between-groups, between-session and within-session variability along with regional mean estimates of CBF. We assessed the number of PASL tag-control image pairs that was needed to provide stable regional estimates of CBF and variability of regional CBF across groups. Forty tag-control image pairs, which take approximately 3 min to acquire using a single inversion label delay time, were adequate for providing stable CBF estimates at the group level. Power calculations based on the variance estimates of regional CBF measurements suggest that comparatively small cohorts are adequate. For example, detecting a 15% change in CBF, depending on the region of interest, requires from 7-15 subjects per group in a crossover design, 6-10 subjects in a within-session design and 20-41 subjects in a between-groups design. Such sample sizes make feasible the use of such CBF measurements in clinical trials of drugs.

journal_name

Magn Reson Imaging

authors

Murphy K,Harris AD,Diukova A,Evans CJ,Lythgoe DJ,Zelaya F,Wise RG

doi

10.1016/j.mri.2011.02.030

subject

Has Abstract

pub_date

2011-12-01 00:00:00

pages

1382-9

issue

10

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(11)00099-3

journal_volume

29

pub_type

杂志文章
  • Empirical optimization of ASL data analysis using an ASL data processing toolbox: ASLtbx.

    abstract::Arterial spin labeling (ASL) perfusion fMRI data differ in important respects from the more familiar blood oxygen level-dependent (BOLD) fMRI data and require specific processing strategies. In this paper, we examined several factors that may influence ASL data analysis, including data storage bit resolution, motion c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.07.003

    authors: Wang Z,Aguirre GK,Rao H,Wang J,Fernández-Seara MA,Childress AR,Detre JA

    更新日期:2008-02-01 00:00:00

  • Assessment of extravascular extracellular space fraction in human melanoma xenografts by DCE-MRI and kinetic modeling.

    abstract::Tumor aggressiveness and response to therapy are influenced by the extravascular extracellular space fraction (EESF) of the malignant tissue. The EESF may, therefore, be an important prognostic parameter for cancer patients. The aim of this study was to investigate whether gadopentetate dimeglumine (Gd-DTPA)-based dyn...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.06.003

    authors: Benjaminsen IC,Brurberg KG,Ruud EB,Rofstad EK

    更新日期:2008-02-01 00:00:00

  • Sex differences in the relationship between white matter microstructure and impulsivity in adolescents.

    abstract::Rapid maturational brain changes occur during adolescence--a time associated with risk-taking behaviors and improvements in cognition. The present study examined the relationship between white matter (WM) microstructure, impulsive behavior and response inhibition in female and male adolescents. Twenty-one healthy adol...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.03.012

    authors: Silveri MM,Rohan ML,Pimentel PJ,Gruber SA,Rosso IM,Yurgelun-Todd DA

    更新日期:2006-09-01 00:00:00

  • MR microscopy of micron scale structures.

    abstract::Magnetic resonance (MR) microscopy of up to 1-5-microm resolutions have been reported previously. The tested phantom structures, however, had widths one order of magnitude bigger than the reported resolutions, e.g., spherical beads or capillary tubes of tens-of-micron diameters or wall thicknesses have been imaged. In...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.01.002

    authors: Lee SC,Kim K,Kim J,Yi JH,Lee S,Cheong C

    更新日期:2009-07-01 00:00:00

  • Electrophoretic NMR studies of electrical transport in fluid-filled porous systems.

    abstract::An NMR technique is described which allows the observation of ionic charge carriers moving in the electric field within a porous system saturated with electrolyte solution. This method, which was recently developed in our laboratory, gives experimental access to the study of electric transport in disordered media on a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00267-3

    authors: Holz M,Heil SR,Schwab IA

    更新日期:2001-04-01 00:00:00

  • The Langerhans' cell histiocytosis (eosinophilic granuloma) of the cervical spine: a rare diagnosis of cervical pain.

    abstract::We present the case of a 44-year-old man who complained of cervical pain. He was treated with physiotherapy and analgetics. Because of persistent pain, computed tomography (CT) scan and MRI were performed. They revealed an osteolytic destruction of the fourth cervical vertebra. The patient was treated surgically for r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2004.01.006

    authors: Simanski C,Bouillon B,Brockmann M,Tiling T

    更新日期:2004-05-01 00:00:00

  • Single-shot-double-echo EPI.

    abstract::Echo planar imaging (EPI) was extended for the acquisition of both, the spin-echo (SE) and the stimulated echo in a stimulated echo sequence after one excitation from thermal equilibrium. The two independent EPI images reflect different states of the transverse magnetization excited and measured almost simultaneously....

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91234-n

    authors: Börnert P,Jensen D

    更新日期:1994-01-01 00:00:00

  • Active intrahepatic gadolinium extravasation following TIPS.

    abstract::A 31-year-old male patient had a transjugular intrahepatic portal systemic shunt (TIPS) placed for acute Budd-Chiari syndrome secondary to paroxysmal nocturnal hemoglobinuria (PNH). Post-procedure, he was anticoagulated for his underlying paroxysmal nocturnal hemoglobinuria. After 11 days, he complained of upper abdom...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00081-2

    authors: Hasegawa S,Eisenberg LB,Semelka RC

    更新日期:1998-09-01 00:00:00

  • Phase gradient imaging for positive contrast generation to superparamagnetic iron oxide nanoparticle-labeled targets in magnetic resonance imaging.

    abstract::Positive contrast imaging methods produce enhanced signal at large magnetic field gradient in magnetic resonance imaging. Several postprocessing algorithms, such as susceptibility gradient mapping and phase gradient mapping methods, have been applied for positive contrast generation to detect the cells targeted by sup...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.04.011

    authors: Zhu H,Demachi K,Sekino M

    更新日期:2011-09-01 00:00:00

  • Issues about the fMRI of the human spinal cord.

    abstract::Noninvasive functional studies on human spinal cord by means of magnetic resonance imaging (MRI) are gaining attention because of the promising applications in the study of healthy and injured central nervous system. The findings obtained are generally consistent with the anatomic knowledge based on invasive methods, ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2004.10.015

    authors: Giove F,Garreffa G,Giulietti G,Mangia S,Colonnese C,Maraviglia B

    更新日期:2004-12-01 00:00:00

  • A new method for diffusion weighted imaging.

    abstract::A new method for generating diffusion contrast in magnetic resonance imaging is presented. This technique is robust enough to allow implementation on conventional imaging systems without hardware modifications. Results from phantom measurements are reported. Qualitative contrast changes in magnetic resonance images de...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90069-p

    authors: Norwood TJ,Williams SC

    更新日期:1993-01-01 00:00:00

  • Pure uterine lipoma.

    abstract::Lipomatous tumors of the uterus are unusual, benign neoplasms seen in postmenopausal women. Although many of the mixed-type cases such as lipoleiomyoma and fibrolipoma have been reported, pure uterine lipomas are extremely rare. In the literature, a few cases with pure uterine lipoma have been reported. We first prese...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.01.116

    authors: Erdem G,Celik O,Karakas HM,Alkan A,Hascalik S

    更新日期:2007-10-01 00:00:00

  • Analysis of machine-dependent and object-induced geometric distortion in 2DFT MR imaging.

    abstract::Geometric distortion in MR imaging predominantly arises from the inhomogeneity of the static field and the nonlinearity of the gradients. It is the purpose of this paper to analyse the object and machine related contributions to geometric distortion in order to determine which corrections are necessary for attaining a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90011-n

    authors: Bakker CJ,Moerland MA,Bhagwandien R,Beersma R

    更新日期:1992-01-01 00:00:00

  • Measurements of RF heating during 3.0-T MRI of a pig implanted with deep brain stimulator.

    abstract:PURPOSE:To present preliminary, in vivo temperature measurements during MRI of a pig implanted with a deep brain stimulation (DBS) system. MATERIALS AND METHODS:DBS system (Medtronic Inc., Minneapolis, MN) was implanted in the brain of an anesthetized pig. 3.0-T MRI was performed with a T/R head coil using the low-SAR...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.11.005

    authors: Gorny KR,Presti MF,Goerss SJ,Hwang SC,Jang DP,Kim I,Min HK,Shu Y,Favazza CP,Lee KH,Bernstein MA

    更新日期:2013-06-01 00:00:00

  • Bilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain.

    abstract::Deep brain stimulation (DBS) is used increasingly in the field of movement disorders. The implanted electrodes create not only a prior risk to patient safety during MRI, but also a unique opportunity in the collection of functional MRI data conditioned by direct neural stimulation. We evaluated MRI-related heating for...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.02.007

    authors: Bhidayasiri R,Bronstein JM,Sinha S,Krahl SE,Ahn S,Behnke EJ,Cohen MS,Frysinger R,Shellock FG

    更新日期:2005-05-01 00:00:00

  • Identification and characterization of biological tissues by NMR. Concerted research project of the European Economic Community. Introduction, objectives, and activities.

    abstract::NMR offers, in the complex proton relaxation properties of biological tissues, a unique and potentially powerful tool of tissue characterization. The difficulties encountered so far in comparing the results of in vitro and in vivo NMR studies carried out in different laboratories inhibit NMR methodologies from fully e...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90447-x

    authors: Podo F,Orr JS,Schmidt KH,Bovée WM

    更新日期:1988-03-01 00:00:00

  • Quantitative multi-modal functional MRI with blood oxygenation level dependent exponential decays adjusted for flow attenuated inversion recovery (BOLDED AFFAIR).

    abstract::A magnetic resonance imaging (MRI) method is described that allows interleaved measurements of transverse (R(2)(*) and R(2)) and longitudinal (R(1)) relaxation rates of tissue water in conjunction with spin labeling. The image-contrasts are intrinsically blood oxygenation level dependent (BOLD) and cerebral blood flow...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00125-9

    authors: Hyder F,Renken R,Kennan RP,Rothman DL

    更新日期:2000-04-01 00:00:00

  • Magnetic resonance imaging: application in musculoskeletal infection.

    abstract::Forty-two patients with clinically suspected osteomyelitis were examined using magnetic resonance imaging (MRI). Twenty-seven patients (64%) had previous surgery or fracture, and 15 (36%) were referred for differentiation of acute osteomyelitis from bone tumors or other pathologic conditions. MRI was compared with com...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(85)90350-9

    authors: Berquist TH,Brown ML,Fitzgerald RH Jr,May GR

    更新日期:1985-01-01 00:00:00

  • A flexible 9-channel coil array for fast 3D MR thermometry in MR-guided high-intensity focused ultrasound (HIFU) studies on rabbits at 3 T.

    abstract::Signal-to-noise ratio (SNR) is a critical factor in MR-guided high-intensity focused ultrasound (HIFU) for local heating, which can affect the accuracy of temperature measurement. In order to achieve high SNR and higher temporal resolution, dedicated coil arrays for MR-guided HIFU applications need to be developed. In...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.10.008

    authors: Chen Q,Li Y,Jiang R,Zou C,Tie C,Wen J,Yang X,Zhang X,Liu X,Zheng H

    更新日期:2020-01-01 00:00:00

  • A new diagnostic approach to vascular rings and pulmonary slings: the role of MRI.

    abstract:UNLABELLED:The conventional diagnostic work-up of a patient suspected of having a vascular cause for stridor, or dysphagia, includes esophagography and bronchoscopy to delineate the abnormal structure without imaging the structure itself. Cine-angiography is regarded as the golden standard, but is not routinely perform...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00245-2

    authors: Beekman RP,Hazekamp MG,Sobotka MA,Meijboom EJ,de Roos A,Staalman CR,Beek FJ,Ottenkamp J

    更新日期:1998-01-01 00:00:00

  • Manifestation and post hoc correction of gradient cross-term artifacts in DTI.

    abstract::Cross-terms between imaging and diffusion gradients, unaccounted for during tensor calculations, can lead to erroneous estimation of diffusivity and fractional anisotropy (FA) in regions of isotropic and anisotropic diffusion. Cross-term of magnitude 136.8±1.6 s/mm(2), artificially introduced in the slice-encode direc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.02.021

    authors: Nair G,Hu XP

    更新日期:2012-07-01 00:00:00

  • Spine MR images in patients with pedicle screw fixation: Comparison of conventional and SEMAC-VAT sequences at 1.5 T.

    abstract:BACKGROUND AND PURPOSE:Slice-encoding metal artifact corrections (SEMAC)-view-angle tilting (VAT) sequences have recently been used in clinical protocols to reduce metal artifacts in MR scans of patients with spinal instrumentation. The objective of this study was to compare the SEMAC-VAT sequence with the conventional...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.08.002

    authors: Park C,Lee E,Yeo Y,Kang Y,Lee JW,Ahn JM,Kang HS

    更新日期:2018-12-01 00:00:00

  • Accurate and sensitive measurements of magnetic susceptibility using echo planar imaging.

    abstract::Susceptibility differences are common causes for artifacts in magnetic resonance (MR); therefore, it is important to choose phantom materials in a way that these artifacts are kept at a minimum. In this study, a previously proposed MR imaging (MRI) method [Beuf O, Briguet A, Lissac M, Davis R. Magnetic resonance imagi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.07.005

    authors: Carlsson A,Starck G,Ljungberg M,Ekholm S,Forssell-Aronsson E

    更新日期:2006-11-01 00:00:00

  • 4D MR phase and magnitude segmentations with GPU parallel computing.

    abstract::The increasing size and number of data sets of large four dimensional (three spatial, one temporal) magnetic resonance (MR) cardiac images necessitates efficient segmentation algorithms. Analysis of phase-contrast MR images yields cardiac flow information which can be manipulated to produce accurate segmentations of t...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.08.019

    authors: Bergen RV,Lin HY,Alexander ME,Bidinosti CP

    更新日期:2015-01-01 00:00:00

  • Characterisation of crosslinked elastomeric materials by 1H NMR relaxation time distributions.

    abstract::One of the most critical structural parameters in elastomeric materials is the density of cross-linking between the polymeric chains. This chemical feature greatly affects chain motions and is determinant in controlling mechanical properties of the final product. NMR techniques are widely and efficiently applied to in...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00257-0

    authors: Borgia GC,Fantazzini P,Ferrando A,Maddinelli G

    更新日期:2001-04-01 00:00:00

  • Biliary cystadenocarcinoma: seven year follow-up and the role of MRI and MRCP.

    abstract::Biliary cystadenomas and their malignant counterparts, biliary cystadenocarcinomas, are rare cystic tumors that arise from hepatobiliary epithelium. Ultrasound (US) and computed tomography (CT) are the initial imaging modalities used for the evaluation of biliary cystic tumors, but are not specific. MRI and MRCP, beca...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00453-2

    authors: Williams DM,Vitellas KM,Sheafor D

    更新日期:2001-11-01 00:00:00

  • Cardiac magnetic resonance tissue tracking in right ventricle: Feasibility and normal values.

    abstract:PURPOSE:To investigate right ventricular (RV) strain in patients without identified cardiac pathology using cardiac magnetic resonance tissue tracking (CMR TT). METHODS:A total of 50 consecutive patients with no identified cardiac pathology were analyzed. RV longitudinal and circumferential strain was assessed by CMR ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.01.007

    authors: Truong VT,Safdar KS,Kalra DK,Gao X,Ambach S,Taylor MD,Moore R,Taylor RJ,Germann J,Toro-Salazar O,Jefferies JL,Bartone C,Raman SV,Ngo T,Mazur W

    更新日期:2017-05-01 00:00:00

  • Undersampled MRI reconstruction with patch-based directional wavelets.

    abstract::Compressed sensing has shown great potential in reducing data acquisition time in magnetic resonance imaging (MRI). In traditional compressed sensing MRI methods, an image is reconstructed by enforcing its sparse representation with respect to a preconstructed basis or dictionary. In this paper, patch-based directiona...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.02.019

    authors: Qu X,Guo D,Ning B,Hou Y,Lin Y,Cai S,Chen Z

    更新日期:2012-09-01 00:00:00

  • Rapid acquisition strategy for functional T1ρ mapping of the brain.

    abstract::Functional T1ρ mapping has been proposed as a method to assess pH and metabolism dynamics in the brain with high spatial and temporal resolution. The purpose of this work is to describe and evaluate a variant of the spin-locked echo-planar imaging sequence for functional T1ρ mapping at 3T. The proposed sequence rapidl...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.07.010

    authors: Johnson CP,Heo HY,Thedens DR,Wemmie JA,Magnotta VA

    更新日期:2014-11-01 00:00:00

  • Analysis of kinetic curve and model-based perfusion parameters on dynamic contrast enhanced MRI in breast cancer patients: Correlations with dominant stroma type.

    abstract:OBJECTIVE:Our purpose was to evaluate imaging findings of breast cancers according to the dominant stroma type by using kinetic curve analysis and model-based perfusion parameters from dynamic contrast-enhanced magnetic resonance imaging. METHODS:From March 2011 to September 2011, 64 cancers in 64 patients were includ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.07.010

    authors: Yim H,Kang DK,Jung YS,Jeon GS,Kim TH

    更新日期:2016-01-01 00:00:00