Magnetic resonance imaging: application in musculoskeletal infection.

Abstract:

:Forty-two patients with clinically suspected osteomyelitis were examined using magnetic resonance imaging (MRI). Twenty-seven patients (64%) had previous surgery or fracture, and 15 (36%) were referred for differentiation of acute osteomyelitis from bone tumors or other pathologic conditions. MRI was compared with computed tomography in 12 cases and with 111In-labeled leukocytes scans in 22. With MRI, 92% of proved infections were detected, and bone and soft-tissue changes were more evident than with routine radiographs, tomography, or computed tomography. In patients with negative cultures and no previous surgery or fracture, it was difficult for MRI to differentiate operative changes from infection. In these patients, 111In-labeled leukocyte images were more specific than MRI.

journal_name

Magn Reson Imaging

authors

Berquist TH,Brown ML,Fitzgerald RH Jr,May GR

doi

10.1016/0730-725x(85)90350-9

subject

Has Abstract

pub_date

1985-01-01 00:00:00

pages

219-30

issue

3

eissn

0730-725X

issn

1873-5894

pii

0730-725X(85)90350-9

journal_volume

3

pub_type

杂志文章
  • Three-dimensional magnetic resonance imaging after ultrasonography for assessment of fetal gastroschisis.

    abstract::A 24-year-old woman (Gravida I, Para I) at estimated 32 weeks of pregnancy was referred to our department for evaluation of a suspected fetal gastroschisis. Ultrasound scan revealed multiple loops of dilated bowel outside the fetal abdomen and absence of membrane surrounding the herniated loops of the intestines. Thre...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.006

    authors: Sasaki Y,Miyamoto T,Hidaka Y,Satoh H,Takuma N,Sengoku K,Sugimori H,Inaoka T,Aburano T

    更新日期:2006-02-01 00:00:00

  • Simultaneous optimization of power and duration of radio-frequency pulse in PARACEST MRI.

    abstract::Chemical exchange saturation transfer (CEST) MRI is increasingly used to probe mobile proteins and microenvironment properties, and shows great promise for tumor and stroke diagnosis. The CEST effect is complex and depends not only on the CEST agent concentration, exchange rates, the characteristic of the magnetizatio...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.02.001

    authors: Rezaeian MR,Hossein-Zadeh GA,Soltanian-Zadeh H

    更新日期:2016-07-01 00:00:00

  • Artifacts in magnetic resonance imaging after surgical resection of brain tumors.

    abstract:BACKGROUND:Since the advent of magnetic resonance imaging, metal artifacts have posed an important diagnostic problem in different fields of medicine. However, this has not been systematically studied in patients undergoing surgery for brain tumors. OBJECTIVE:This study was planned to assess whether metal artifacts ca...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.11.001

    authors: Bagheri MH,Ahmadloo N,Rezaian S

    更新日期:2013-06-01 00:00:00

  • Recreational runners with patellofemoral pain exhibit elevated patella water content.

    abstract::Increased bone water content resulting from repetitive patellofemoral joint overloading has been suggested to be a possible mechanism underlying patellofemoral pain (PFP). To date, it remains unknown whether persons with PFP exhibit elevated bone water content. The purpose of this study was to determine whether recrea...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.04.018

    authors: Ho KY,Hu HH,Colletti PM,Powers CM

    更新日期:2014-09-01 00:00:00

  • Neuroprotective effect of agmatine in rats with transient cerebral ischemia using MR imaging and histopathologic evaluation.

    abstract:PURPOSE:This study aimed to further investigate the effects of agmatine on brain edema in the rats with middle cerebral artery occlusion (MCAO) injury using magnetic resonance imaging (MRI) monitoring and biochemical and histopathologic evaluation. MATERIALS AND METHODS:Following surgical induction of MCAO for 90min, ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.03.026

    authors: Huang YC,Tzeng WS,Wang CC,Cheng BC,Chang YK,Chen HH,Lin PC,Huang TY,Chuang TJ,Lin JW,Chang CP

    更新日期:2013-09-01 00:00:00

  • Automated segmentation of lateral ventricles from human and primate magnetic resonance images using cognition network technology.

    abstract::Automatic segmentation of different types of tissue from magnetic resonance images is of great importance for clinical and research applications, particularly large-scale and longitudinal studies of brain pathology. We developed a fully automated algorithm for the segmentation of lateral ventricles from cranial magnet...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.08.013

    authors: Schönmeyer R,Prvulovic D,Rotarska-Jagiela A,Haenschel C,Linden DE

    更新日期:2006-12-01 00:00:00

  • Inherent spatial structure in myelin water fraction maps.

    abstract::Myelin water fraction (MWF) images in brain tend to be spatially noisy with unknown or no apparent spatial patterns structure, so values are therefore typically averaged over large white matter (WM) volumes. We investigated the existence of an inherent spatial structure in MWF maps and explored the benefits of examini...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.09.012

    authors: Baumeister TR,Kolind SH,MacKay AL,McKeown MJ

    更新日期:2020-04-01 00:00:00

  • Susceptibility-matched envelope for the correction of EPI artifacts.

    abstract::Fast gradient echo sequences, such as echo planer imaging (EPI) and spiral imaging, are vulnerable to artifacts resulting from B(0) inhomogeneities. A major contribution to these artifacts is the susceptibility variation across the head, which is most severe in regions adjacent to air-tissue interfaces, such as the mo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.07.011

    authors: Neufeld A,Assaf Y,Graif M,Hendler T,Navon G

    更新日期:2005-11-01 00:00:00

  • Investigating mobility of crude oil adsorbates on mineral surfaces by NMR.

    abstract::We have applied diffusion and relaxation Nuclear Magnetic Resonance experiments to investigate the translational and rotational mobility of adsorbents on quartz and calcite mineral surfaces. On both surfaces it was found that water is the dominant molecule. On the quartz surface the majority of water molecules have a ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.10.002

    authors: Sørgård HN,Totland C,Nerdal W,Seland JG

    更新日期:2019-02-01 00:00:00

  • Dynamic contrast-enhanced MRI to assess hepatocellular carcinoma response to Transarterial chemoembolization using LI-RADS criteria: A pilot study.

    abstract:PURPOSE:To identify quantitative dynamic contrast-enhanced (DCE)-MRI perfusion parameters indicating tumor response of hepatocellular carcinoma (HCC) to transarterial chemoembolization (TACE). MATERIALS AND METHODS:This prospective pilot study was approved by our institutional review board; written and informed consen...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.mri.2019.06.017

    authors: Thibodeau-Antonacci A,Petitclerc L,Gilbert G,Bilodeau L,Olivié D,Cerny M,Castel H,Turcotte S,Huet C,Perreault P,Soulez G,Chagnon M,Kadoury S,Tang A

    更新日期:2019-10-01 00:00:00

  • Astrocytic energy metabolism and glutamate formation--relevance for 13C-NMR spectroscopy and importance of cytosolic/mitochondrial trafficking.

    abstract::Glutamate plays a double role in (13)C-nuclear magnetic resonance (NMR) spectroscopic determination of glucose metabolism in the brain. Bidirectional exchange between initially unlabeled glutamate and labeled α-ketoglutarate, formed from pyruvate via pyruvate dehydrogenase (PDH), indicates the rate of energy metabolis...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.04.013

    authors: Hertz L

    更新日期:2011-12-01 00:00:00

  • Predictability of SNR and reader preference in clinical MR imaging.

    abstract::Fifty-four independent scans were performed in two volunteers covering one anatomic region in each (the brain and knee) with the purpose of ascertaining the agreement between predicted and measured signal-to-noise ratios (SNR). Systematically varied parameters were number of excitations (NEX), field of view (FOV), sec...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90009-q

    authors: Owen RS,Wehrli FW

    更新日期:1990-01-01 00:00:00

  • Magnetic resonance cholangiopancreatography: comparison between respiratory-triggered turbo spin echo and breath hold single-shot turbo spin echo sequences.

    abstract::The purpose of this study was to compare the relative conspicuity of the pancreaticobiliary tree on respiratory-triggered three-dimensional turbo spin echo (3D TSE RT) and breath hold single-shot turbo spin echo (SSTSE BH) acquisitions respectively in MRCP imaging. Both techniques were applied to 61 patients with clin...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00074-0

    authors: Papanikolaou N,Karantanas AH,Heracleous E,Costa JC,Gourtsoyiannis N

    更新日期:1999-11-01 00:00:00

  • Short T2 contrast with three-dimensional ultrashort echo time imaging.

    abstract::There is increasing interest in imaging short T2 species which show little or no signal with conventional magnetic resonance (MR) pulse sequences. In this paper, we describe the use of three-dimensional ultrashort echo time (3D UTE) sequences with TEs down to 8 μs for imaging of these species. Image contrast was gener...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.11.003

    authors: Du J,Bydder M,Takahashi AM,Carl M,Chung CB,Bydder GM

    更新日期:2011-05-01 00:00:00

  • High-resolution MR venography of cerebral arteriovenous malformations.

    abstract::The purpose of this study was to evaluate the diagnostic potential of a high-resolution magnetic resonance (MR) venography technique in patients with cerebral arteriovenous malformations (AVMs). A high-resolution 3D gradient echo sequence was used with a long echo time TE to obtain venous information down to sub-pixel...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00084-3

    authors: Essig M,Reichenbach JR,Schad LR,Schoenberg SO,Debus J,Kaiser WA

    更新日期:1999-12-01 00:00:00

  • High-energy phosphate metabolism during incremental calf exercise in humans measured by 31 phosphorus magnetic resonance spectroscopy (31P MRS).

    abstract::Several previous 31 phosphorus magnetic resonance spectroscopy ((31)P MRS) studies performing incremental or progressive muscle exercises have observed that a decrease in pH is accompanied with an acceleration in phosphocreatine (PCr) hydrolysis. The purpose of this study was to investigate the relationship between PC...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.07.001

    authors: Schocke MF,Esterhammer R,Kammerlander C,Rass A,Kremser C,Fraedrich G,Jaschke WR,Greiner A

    更新日期:2004-01-01 00:00:00

  • Real-time animal functional magnetic resonance imaging and its application to neuropharmacological studies.

    abstract::In pharmacological magnetic resonance imaging (phMRI) with anesthetized animals, there is usually only a single time window to observe the dynamic signal change to an acute drug administration since subsequent drug injections are likely to result in altered response properties (e.g., tolerance). Unlike the block-desig...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.02.020

    authors: Lu H,Yang S,Zuo Y,Demny S,Stein EA,Yang Y

    更新日期:2008-11-01 00:00:00

  • Superparamagnetic iron oxide particles and positive enhancement for myocardial perfusion studies assessed by subsecond T1-weighted MRI.

    abstract::Superparamagnetic iron oxide particles (SPIOs) are usually referred to as T2 MR contrast agents, reducing signal intensity (SI) on T2-weighted MR images (negative enhancement). This study reports the original use of SPIOs as T1-enhancing contrast agents, primarily assessed in vitro, and then applied to an in vivo inve...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90241-5

    authors: Canet E,Revel D,Forrat R,Baldy-Porcher C,de Lorgeril M,Sebbag L,Vallee JP,Didier D,Amiel M

    更新日期:1993-01-01 00:00:00

  • Microstructure abnormity in the optic nerve of type 1 diabetic rats revealed by diffusion tensor imaging study.

    abstract::Diabetic retinopathy (DR) is one of a major complication of type 1 diabetes mellitus (T1DM) and a leading cause of blindness. Evidence of animal study has shown that it is not only a microvasucular lesion of the eye, but also a neurodegeneration disease of the visual system. However, the in vivo imaging evidence of ax...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.05.003

    authors: Gao L,Huang M,Luo X,Song T,Wang X,Wang Z,Zhang W,Chen J,Lei H

    更新日期:2020-09-01 00:00:00

  • Non-contrast enhanced 3D SSFP MRA of the renal allograft vasculature: a comparison between radial linear combination and Cartesian inflow-weighted acquisitions.

    abstract::Renal transplant patients often require imaging to ensure appropriate graft placement, to assess integrity of transplant vessel anastomosis and to evaluate for stenosis that can be a cause of graft failure. Because there is risk for nephrogenic systemic fibrosis in the setting of renal insufficiency, the use of non-co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.10.004

    authors: Bultman EM,Klaers J,Johnson KM,François CJ,Schiebler ML,Reeder SB,Block WF

    更新日期:2014-02-01 00:00:00

  • High-resolution magnetic resonance flow imaging in a model of porous bone-implant interface.

    abstract:PURPOSE:To evaluate the application of high-resolution MRI methodology for characterizing the fluid velocity field and evaluate fluid shear field within a simplified in vitro model of a bone-implant interface. MATERIALS AND METHODS:The study used a specific micromotion canine bone implant that has been used for over a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.11.001

    authors: Conroy MJ,Pédrono A,Bechtold JE,Søballe K,Ambard D,Swider P

    更新日期:2006-06-01 00:00:00

  • Measurement of fat fraction in the human thymus by localized NMR and three-point Dixon MRI techniques.

    abstract:PURPOSE:To develop a protocol to non-invasively measure and map fat fraction, fat/(fat+water), as a function of age in the adult thymus for future studies monitoring the effects of interventions aimed at promoting thymic rejuvenation and preservation of immunity in older adults. MATERIALS AND METHODS:Three-dimensional...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.03.016

    authors: Fishbein KW,Makrogiannis SK,Lukas VA,Okine M,Ramachandran R,Ferrucci L,Egan JM,Chia CW,Spencer RG

    更新日期:2018-07-01 00:00:00

  • SmartPhantom--an fMRI simulator.

    abstract::Many informatics tools have emerged to process the voluminous and complex data generated by functional magnetic resonance imaging (fMRI). The interpretation of fMRI exams is largely determined by these tools. However, their performance is hard to evaluate because there is no independent means of calibration. A novel f...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.012

    authors: Cheng H,Zhao Q,Duensing GR,Edelstein WA,Spencer D,Browne N,Saylor C,Limkeman M

    更新日期:2006-04-01 00:00:00

  • Internal derangement of the temporomandibular joint: radiologic staging with clinical, surgical, and pathologic correlation.

    abstract::The radiologic findings from 60 patients with 86 internally deranged temporomandibular joints (TMJ) upon whom sequential imaging procedures had been performed over a period of two months to ten years were analyzed and correlated with clinical, surgical (72 joints), and pathological observations. Internal derangement o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90404-9

    authors: Schellhas KP

    更新日期:1989-09-01 00:00:00

  • A robust electrical conductivity imaging method with total variation and wavelet regularization.

    abstract:PURPOSE:This study aims to develop and evaluate a robust conductivity imaging method that combines total variation and wavelet regularization to enhance the accuracy of conductivity maps. THEORY AND METHODS:The proposed approach is based on a gradient-based method. The central equation is derived from Maxwell's equati...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.02.015

    authors: Sun X,Lu L,Qi L,Mei Y,Liu X,Chen W

    更新日期:2020-06-01 00:00:00

  • Quantitative analysis of asymmetrical cortical activity in motor areas during sequential finger movement.

    abstract::Brain asymmetry is a phenomenon well known for handedness and has been studied in motor cortices. However, few quantitative studies on asymmetrical cortical activity in motor areas have been conducted. In this study, we systematically investigated asymmetrical cortical activity in motor areas during sequential finger ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.03.024

    authors: Zeng L,Chen H,Ouyang L,Yao D,Gao JH

    更新日期:2007-12-01 00:00:00

  • Lesion load measurements in multiple sclerosis: the effect of incorporating magnetization transfer contrast in fast-FLAIR sequence.

    abstract::We compared the ability and reproducibility of a fast fluid-attenuated inversion recovery (fast-FLAIR) sequence with and without a magnetization transfer (MT) pulse for detecting and measuring multiple sclerosis (MS)-related abnormalities on magnetic resonance imaging (MRI) scans from 20 patients. The Contrast-to-Nois...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00182-9

    authors: Filippi M,Rocca MA,Mastronardo G,Comi G

    更新日期:1999-04-01 00:00:00

  • Intracranial vascular feature changes in time of flight MR angiography in patients undergoing carotid revascularization surgery.

    abstract:PURPOSE:To characterize the intracranial vascular features extracted from time of flight (TOF) images and their changes from baseline to follow-up in patients undergoing carotid revascularization, using arterial spin labeling (ASL) cerebral blood flow (CBF) measurement as a reference. METHODS:In this retrospective stu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.10.004

    authors: Chen Z,Chen L,Shirakawa M,Liu W,Ortega D,Chen J,Balu N,Trouard T,Hatsukami TS,Zhou W,Yuan C

    更新日期:2021-01-01 00:00:00

  • Intensity dependence of flow signal in slice selective velocity measurements.

    abstract::The quantitative determination of flow velocities using inflow-outflow techniques require slice selective excitation pulses. The intensity-velocity relationship for such methods is shown to be such that flow velocities estimated using techniques which rely on an absolute calibration of the measured intensity are sensi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90325-1

    authors: Saloner D

    更新日期:1989-01-01 00:00:00

  • A new RF transmit coil for foot and ankle imaging at 7T MRI.

    abstract::A four-channel Tic-Tac-Toe (TTT) transmit RF coil was designed and constructed for foot and ankle imaging at 7T MRI. Numerical simulations using an in-house developed FDTD package and experimental analyses using a homogenous phantom show an excellent agreement in terms of B1+ field distribution and s-parameters. Simul...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.09.005

    authors: Santini T,Kim J,Wood S,Krishnamurthy N,Farhat N,Maciel C,Raval SB,Zhao T,Ibrahim TS

    更新日期:2018-01-01 00:00:00