Investigating mobility of crude oil adsorbates on mineral surfaces by NMR.

Abstract:

:We have applied diffusion and relaxation Nuclear Magnetic Resonance experiments to investigate the translational and rotational mobility of adsorbents on quartz and calcite mineral surfaces. On both surfaces it was found that water is the dominant molecule. On the quartz surface the majority of water molecules have a relatively high degree of both rotational and translational mobility, while a minor fraction of water molecules, and all hydrocarbon molecules, have a significantly lower mobility. On the calcite surface the translational mobility is very low for all the adsorbed molecules, while there is a large diversity in rotational mobility, indicating that the hydrocarbon molecules are strongly attached to the surface, but that some part of each molecule still have a large degree of rotational mobility. Diffusion and relaxation experiments give a detailed description of both the molecular mobility of adsorbed species on these mineral surfaces, which leads to new insight with respect to aging processes on a molecular level.

journal_name

Magn Reson Imaging

authors

Sørgård HN,Totland C,Nerdal W,Seland JG

doi

10.1016/j.mri.2018.10.002

subject

Has Abstract

pub_date

2019-02-01 00:00:00

pages

86-89

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(18)30433-8

journal_volume

56

pub_type

杂志文章
  • Simultaneous PET-MRI in oncology: a solution looking for a problem?

    abstract::With the recent development of integrated positron emission tomography-magnetic resonance imaging (PET-MRI) scanners, new possibilities for quantitative molecular imaging of cancer are realized. However, the practical advantages and potential clinical benefits of the ability to record PET and MRI data simultaneously m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2012.06.001

    authors: Yankeelov TE,Peterson TE,Abramson RG,Izquierdo-Garcia D,Arlinghaus LR,Li X,Atuegwu NC,Catana C,Manning HC,Fayad ZA,Gore JC

    更新日期:2012-11-01 00:00:00

  • Arterial input functions (AIFs) measured directly from arteries with low and standard doses of contrast agent, and AIFs derived from reference tissues.

    abstract::Measurements of arterial input function (AIF) can have large systematic errors at standard contrast agent doses in dynamic contrast enhanced MRI (DCE-MRI). We compared measured AIFs from low dose (AIFLD) and standard dose (AIFSD) contrast agent injections, as well as the AIF derived from a muscle reference tissue and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.10.025

    authors: Wang S,Fan X,Medved M,Pineda FD,Yousuf A,Oto A,Karczmar GS

    更新日期:2016-02-01 00:00:00

  • Acute pancreatic graft fistula and peripancreatic fluid collection: demonstration by secretin-stimulated MRI.

    abstract::Peripancreatic fluid collections are among the common post pancreas transplant complications, which are mainly due to leakage from the anastomosis site to bowel and graft pancreatitis. Differentiation between these two entities is important because they are treated differently. In this case, secretin stimulated magnet...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.02.003

    authors: Alkaade S,Fattahi R,Balci NC,Akduman EI,Garvin PJ,Modanlou KA,Burton FR

    更新日期:2009-09-01 00:00:00

  • Factors affecting nitroxide reduction in ascorbate solution and tissue homogenates.

    abstract::Because of their paramagnetic properties, nitroxides are potentially useful as contrast agents in magnetic resonance imaging (MRI). They are reduced in vivo to their corresponding hydroxylamines which are nonparamagnetic and have no contrast enhancing property. Nitroxides with high resistance to reduction would be adv...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(85)90012-8

    authors: Couet WR,Brasch RC,Sosnovsky G,Tozer TN

    更新日期:1985-01-01 00:00:00

  • Simultaneous recording of neuronal signals and functional NMR imaging.

    abstract::We recently directly examined the relationship between blood-oxygen-level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signals and neural activity by simultaneously acquiring electrophysiological and fMRI data from monkeys in a 4.7-T vertical scanner (Logothetis NK, Pauls J, Augath MA, Trinath T, Oelt...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.03.015

    authors: Oeltermann A,Augath MA,Logothetis NK

    更新日期:2007-07-01 00:00:00

  • Detection of mycotic pseudoaneurysm of the ascending aorta using MRI.

    abstract::Mycotic pseudoaneurysms of the ascending aorta are rare cardiovascular lesions that carry the risk of potentially disastrous complications such as aortic rupture or widespread sepsis. Regardless of its location in the arterial system, this lesion carries a high mortality rate. Early diagnosis of mycotic pseudoaneurysm...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90251-8

    authors: McCuskey WH,Loehr SP,Smidebush GC,Link KM

    更新日期:1993-01-01 00:00:00

  • In vivo proton magnetic resonance spectroscopy of alcohol in rhesus monkey brain.

    abstract::Brain alcohol was measured in rhesus monkeys (Macaca mulatta) by proton magnetic resonance spectroscopy (MRS) following acute nasogastric alcohol administration (0.8 g/kg). Monkeys were anesthetized with ketamine and xylazine. A 1.5 T whole body imager and a 3-inch surface coil were used to acquire TE 30 and 270 ms sp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)90089-a

    authors: Kaufman MJ,Chiu TM,Mendelson JH,Woods BT,Mello NK,Lukas SE,Fivel PA,Wighton LG

    更新日期:1994-01-01 00:00:00

  • In vivo animal tests of an artifact-free contrast agent for gastrointestinal MRI.

    abstract::A variety of shortcomings are associated with most currently used gastrointestinal contrast agents for magnetic resonance imaging (MRI). Artifacts resulting from peristalsis and other motions in the abdominal region are produced by many positive contrast agents (which increase signal intensity). Although this is not a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00020-9

    authors: Briggs RW,Wu Z,Mladinich CR,Stoupis C,Gauger J,Liebig T,Ros PR,Ballinger JR,Kubilis P

    更新日期:1997-01-01 00:00:00

  • MRI of the normal hippocampus.

    abstract::Before it is possible to use MR imaging to investigate changes in the hippocampus in disease processes such as epilepsy and memory disorders, it is imperative that normal variations are defined. Using specific anatomic locations, we evaluated the hippocampi of 29 normal volunteers with coronal MR studies. Mild variati...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90035-k

    authors: Bronen RA,Cheung G

    更新日期:1991-01-01 00:00:00

  • Localization of ischemia in canine hearts using tagged rotated long axis MR images, endocardial surface stretch and wall thickening.

    abstract::Tagged magnetic resonance imaging allows the noninvasive measurement of regional systolic myocardial deformations and helps localize ischemic regions in the left ventricle (LV). The objective of this study was to evaluate the potential accuracy of localizing ischemic regions in the LV using endocardial and epicardial ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00161-6

    authors: Denisova O,Shapiro EP,Weiss JL,Azhari H

    更新日期:1997-01-01 00:00:00

  • Sampling time effects on signal-to-noise and contrast-to-noise ratios in spin-echo MRI.

    abstract::This work discusses the effect of sampling time on noise, signal-to-noise and contrast-to-noise ratios in magnetic resonance imaging. A simple imaging experiment is performed to demonstrate the effect of sampling time on noise, confirming theoretical expectations that doubling the sampling time while decreasing the re...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90481-4

    authors: Hendrick RE

    更新日期:1987-01-01 00:00:00

  • Functional magnetic resonance imaging in a stereotactic setup.

    abstract::The localization of critical structures within the brain is important for the planning of therapeutic strategies. Functional MRI is capable to assess functional response of cortical structures to certain stimuli. The authors present two techniques for functional MRI (fMRI) in a stereotactic set-up. The skull of the pa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)02108-x

    authors: Debus J,Essig M,Schad LR,Wenz F,Baudendistel K,Knopp MV,Engenhart R,Lorenz WJ

    更新日期:1996-01-01 00:00:00

  • Signal and contrast effects due to T2 decay during k-space readout of UTE (ultrashort TE) sequences.

    abstract::In ultrashort TE (UTE) imaging, the short T2 values of the tissues of interest are comparable to the k-space readout duration, which result in significant T2 decay during k-space readout. This decay consequently causes significant effects on signal and contrast in UTE sequences, which we evaluate in this paper using m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.11.002

    authors: Chiang JT,Carl M,Du J

    更新日期:2014-04-01 00:00:00

  • In vivo mapping of functional domains and axonal connectivity in cat visual cortex using magnetic resonance imaging.

    abstract::Noninvasive cognitive neuroimaging studies based on functional magnetic resonance imaging (fMRI) are of ever-increasing importance for basic and clinical neurosciences. The explanatory power of fMRI could be greatly expanded, however, if the pattern of the neuronal circuitry underlying functional activation could be m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.08.014

    authors: Kim DS,Kim M,Ronen I,Formisano E,Kim KH,Ugurbil K,Mori S,Goebel R

    更新日期:2003-12-01 00:00:00

  • Off-resonance correction using an estimated linear time map.

    abstract::Images acquired in the presence of magnetic field deviations and reconstructed without taking into account the off-resonance, are distorted and corrupted with artifacts. Several post-processing algorithms have been developed for correcting the distortion when it is not possible to fix the field inhomogeneities. These ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00487-3

    authors: Akel JA,Rosenblitt M,Irarrazaval P

    更新日期:2002-02-01 00:00:00

  • Selective microvascular muscle perfusion imaging in the shoulder with intravoxel incoherent motion (IVIM).

    abstract::The evaluation of local muscle recruitment during a specific movement can be done indirectly by measuring changes in local blood flow. Intravoxel incoherent motion perfusion imaging exploits some properties of the magnetic resonance to measure locally microvascular perfusion, and seems ideally suited for this task. We...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.08.005

    authors: Nguyen A,Ledoux JB,Omoumi P,Becce F,Forget J,Federau C

    更新日期:2017-01-01 00:00:00

  • Neurophysiological and functional MRI evidence of reorganization of cortical motor areas in cerebral arteriovenous malformation.

    abstract::Functional magnetic resonance imaging (fMRI) research has shown that brain arteriovenous malformations (AVMs) lead to reorganization of cortical motor areas. Since it is known that blood oxygenation level-dependent signal in fMRI may be influenced by the hemodynamic perturbation associated with the presence of the AVM...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.029

    authors: Caramia F,Francia A,Mainero C,Tinelli E,Palmieri MG,Colonnese C,Bozzao L,Caramia MD

    更新日期:2009-12-01 00:00:00

  • Chiari malformation type I: a new MRI classification.

    abstract::Thirty patients with Chiari I malformation were examined by MRI over 2-year period. All patients underwent MRI scan before and after surgical decompression of the posterior fossa. Images of the craniocervical junction confirmed tonsillar herniation in all cases and allowed the definition of two anatomically distinct t...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00383-9

    authors: Amer TA,el-Shmam OM

    更新日期:1997-01-01 00:00:00

  • Three dimensional k-space trajectory design using genetic algorithms.

    abstract::Image quality and total scan time in MRI are determined in large part by the trajectory employed to sample the Fourier space. Each trajectory has different properties like coverage of k-space, scan time, sensitivity to off-resonance conditions, etc. These properties are often contradictory, therefore a universal optim...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00174-7

    authors: Sabat S,Mir R,Guarini M,Guesalaga A,Irarrazaval P

    更新日期:2003-09-01 00:00:00

  • Noninvasive evaluation of the regional variations of GABA using magnetic resonance spectroscopy at 3 Tesla.

    abstract:PURPOSE:Rapid regional fluctuations in GABA may result in inhomogeneous concentrations throughout the brain parenchyma. The goal of this study is to provide further insight into the natural distribution of GABA throughout the brain and thus determine if a surrogate site may be used for spectroscopy when evaluating moto...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.02.015

    authors: Durst CR,Michael N,Tustison NJ,Patrie JT,Raghavan P,Wintermark M,Sendhil Velan S

    更新日期:2015-06-01 00:00:00

  • MRI of polysplenia syndrome.

    abstract::The polysplenia syndrome is the association of multiple spleens, situs inversus, congenital heart disease, and azygous continuation of the inferior vena cava. Magnetic resonance (MR) is a noninvasive imaging modality which can easily confirm the multiplicity of spleens, situs inversus, and identify complex congenital ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90538-9

    authors: Jelinek JS,Stuart PL,Done SL,Ghaed N,Rudd SA

    更新日期:1989-11-01 00:00:00

  • Usefulness of cervical magnetic resonance imaging for detecting type A acute aortic dissection with acute stroke symptoms.

    abstract::Type A acute aortic dissection (TAAAD) sometimes presents with acute stroke-like symptoms. When intravenous tissue plasminogen activator (IV-tPA) therapy is considered for acute ischemic stroke, TAAAD must be excluded. Painless TAAAD presenting with acute stroke may be easily missed. Two cases of painless TAAAD presen...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.04.021

    authors: Matsumoto H,Yoshida Y,Hirata Y

    更新日期:2016-09-01 00:00:00

  • Non-contrast enhanced 3D SSFP MRA of the renal allograft vasculature: a comparison between radial linear combination and Cartesian inflow-weighted acquisitions.

    abstract::Renal transplant patients often require imaging to ensure appropriate graft placement, to assess integrity of transplant vessel anastomosis and to evaluate for stenosis that can be a cause of graft failure. Because there is risk for nephrogenic systemic fibrosis in the setting of renal insufficiency, the use of non-co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.10.004

    authors: Bultman EM,Klaers J,Johnson KM,François CJ,Schiebler ML,Reeder SB,Block WF

    更新日期:2014-02-01 00:00:00

  • Magnetic resonance imaging of mouse Ehrlich carcinoma growth inhibition by thiacarpine, an analogue of cytotoxic marine alkaloid polycarpine.

    abstract::The anticancer effect of thiacarpine, a synthetic analogue of the known cytotoxic alkaloid polycarpine isolated from the Pacific ascidian Polycarpa aurata, was investigated in vivo in experiments using mouse solid Ehrlich carcinoma tumor as the target. A high-resolution magnetic resonance imaging (MRI) technique using...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.01.014

    authors: Agafonova IG,Radchenko OS,Novikov VL,Aminin DL,Stonik VA

    更新日期:2008-07-01 00:00:00

  • NMR in rotating magnetic fields: magic-angle field spinning.

    abstract::Magic-angle sample spinning is one of the cornerstones in high-resolution NMR of solid and semisolid materials. The technique enhances spectral resolution by averaging away rank 2 anisotropic spin interactions, thereby producing isotropic-like spectra with resolved chemical shifts and scalar couplings. In principle, i...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.11.067

    authors: Sakellariou D,Meriles CA,Martin RW,Pines A

    更新日期:2005-02-01 00:00:00

  • In vitro experiments on ICOSA6 4D flow MRI measurement for the quantification of velocity and turbulence parameters.

    abstract:PURPOSE:To perform comprehensive in vitro experiments using six-directional icosahedral flow encoding (ICOSA6) 4D flow magnetic resonance imaging (MRI) under various scan conditions to analyze the robustness of velocity and turbulence quantification. MATERIALS AND METHODS:In vitro flow phantoms with steady flow rates ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.06.020

    authors: Ha H,Park KJ,Dyverfeldt P,Ebbers T,Yang DH

    更新日期:2020-10-01 00:00:00

  • The effects of respiratory CO2 fluctuations in the resting-state BOLD signal differ between eyes open and eyes closed.

    abstract::Resting fluctuations in arterial CO2 (a cerebral vasodilator) are believed to be an important source of low-frequency blood oxygenation level dependent (BOLD) signal fluctuations. In this study we focus on the two commonly used resting-states in functional magnetic resonance imaging experiments, eyes open and eyes clo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.013

    authors: Peng T,Niazy R,Payne SJ,Wise RG

    更新日期:2013-04-01 00:00:00

  • Evaluation of stacked resonators to enhance the performance of a surface receive-only array for prostate MRI at 3 Tesla.

    abstract::Prostate MRI is an important tool to diagnose and characterize cancer. High local sensitivity and good parallel imaging performance are of paramount importance for diagnostic quality and efficiency. The purpose of this work was to evaluate stacked resonators as part of a surface receiver array for prostate MRI at 3 Te...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.07.010

    authors: Chacon-Caldera J,Fischer A,Malzacher M,Vetter Y,Davids M,Flöser M,Stumpf C,Schad LR

    更新日期:2018-11-01 00:00:00

  • A computer algorithm for the simulation of any nuclear magnetic resonance (NMR) imaging method.

    abstract::More than a dozen Nuclear Magnetic Resonance (NMR) imaging methods have been described using different radio-frequency pulse sequences, magnetic field gradient variations, and data processing. In order to have a theoretical understanding in the most general case, we have conceived a computer program for the simulation...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(84)90065-1

    authors: Bittoun J,Taquin J,Sauzade M

    更新日期:1984-01-01 00:00:00

  • Correlations and dissociations between BOLD signal and P300 amplitude in an auditory oddball task: a parametric approach to combining fMRI and ERP.

    abstract::A parametric method is proposed to examine the relationship between neuronal activity, measured with event related potentials (ERPs), and the hemodynamic response, observed with functional magnetic resonance imaging (fMRI), during an auditory oddball paradigm. After verifying that the amplitude of the evoked response ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00496-4

    authors: Horovitz SG,Skudlarski P,Gore JC

    更新日期:2002-05-01 00:00:00