SmartPhantom--an fMRI simulator.

Abstract:

:Many informatics tools have emerged to process the voluminous and complex data generated by functional magnetic resonance imaging (fMRI). The interpretation of fMRI exams is largely determined by these tools. However, their performance is hard to evaluate because there is no independent means of calibration. A novel fMRI calibration system called SmartPhantom has been developed to simulate functional blood oxygen level dependent (BOLD) imaging. SmartPhantom contains a quadrature radio frequency coil, comprising two perpendicular planar loops that can be externally activated or deactivated. The system is able to produce reasonably uniform signal enhancements in a calibration sample surrounded by the two loops during an MRI scan. The enhancement is controlled well in both magnitude and predefined timing and produces BOLD-like signals. Characteristics of SmartPhantom are discussed in detail, followed by a comparison of fMRI informatics tools. Two fMRI data sets are acquired with the SmartPhantom. One with high signal-to-noise ratio provides the calibration. Another with lower SNR is input into three software packages (BrainVoyager, FSL and Statistical Parametric Mapping 2) for data preprocessing and statistical analysis. Results from the three packages are compared in both sensitivity of detecting the activation and correlation between the predicted activation and calibration.

journal_name

Magn Reson Imaging

authors

Cheng H,Zhao Q,Duensing GR,Edelstein WA,Spencer D,Browne N,Saylor C,Limkeman M

doi

10.1016/j.mri.2005.12.012

subject

Has Abstract

pub_date

2006-04-01 00:00:00

pages

301-13

issue

3

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(05)00377-2

journal_volume

24

pub_type

杂志文章
  • Rapid assessment of regional and global left ventricular function using three-dimensional k-t BLAST imaging.

    abstract:OBJECTIVE:To test if three-dimensional (3D) cine spatial frequency-temporal frequency Broad-use Linear Acquisition Speed-up Technique (k-t BLAST) is suitable for rapid evaluation of global and regional left ventricular (LV) functional parameters and to evaluate the influence of gadolinium administration. MATERIALS AND...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.01.027

    authors: Huber S,Muthupillai R,Mojibian H,Cheong B,Kouwenhoven M,Flamm SD

    更新日期:2008-07-01 00:00:00

  • Pulsed arterial spin labeling perfusion imaging at 3 T: estimating the number of subjects required in common designs of clinical trials.

    abstract::Pulsed arterial spin labeling (PASL) is an increasingly common technique for noninvasively measuring cerebral blood flow (CBF) and has previously been shown to have good repeatability. It is likely to find a place in clinical trials and in particular the investigation of pharmaceutical agents active in the central ner...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.02.030

    authors: Murphy K,Harris AD,Diukova A,Evans CJ,Lythgoe DJ,Zelaya F,Wise RG

    更新日期:2011-12-01 00:00:00

  • Undifferentiated (embryonal) sarcoma of the liver (USL): MRI findings including dynamic gadolinium enhancement.

    abstract::We report the MR appearance of undifferentiated (embryonal) sarcoma of the liver (USL) in a 13-year-old female who presented with a 1-year history of intermittent abdominal pain, weight loss, and fatigue. The tumor was a large, solitary, well-defined focal mass lesion with multiple cystic spaces, septations, and subst...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.02.003

    authors: Psatha EA,Semelka RC,Fordham L,Firat Z,Woosley JT

    更新日期:2004-07-01 00:00:00

  • T1 and T2* mapping of the human quadriceps and patellar tendons using ultra-short echo-time (UTE) imaging and bivariate relaxation parameter-based volumetric visualization.

    abstract::Quantification of magnetic resonance (MR)-based relaxation parameters of tendons and ligaments is challenging due to their very short transverse relaxation times, requiring application of ultra-short echo-time (UTE) imaging sequences. We quantify both T1 and T2* in the quadriceps and patellar tendons of healthy volunt...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.07.015

    authors: Krämer M,Maggioni MB,Brisson NM,Zachow S,Teichgräber U,Duda GN,Reichenbach JR

    更新日期:2019-11-01 00:00:00

  • Magnetic resonance imaging at frequencies below 1 kHz.

    abstract::Within the magnetic resonance imaging (MRI) community the trend is going to higher and higher magnetic fields, ranging from 1.5 T to 7 T, corresponding to Larmor frequencies of 63.8-298 MHz. Since for high-field MRI the magnetization increases with the applied magnetic field, the signal-to-noise-ratio increases as wel...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.014

    authors: Hilschenz I,Körber R,Scheer HJ,Fedele T,Albrecht HH,Mario Cassará A,Hartwig S,Trahms L,Haase J,Burghoff M

    更新日期:2013-02-01 00:00:00

  • Two-point method for T1 estimation with optimized gradient-echo sequence.

    abstract::Relaxation times estimation methods play a central role in various problems, such as magnetic resonance (MR) hardware calibration, tissue characterization, or temperature measurement. Previous studies have proposed optimization criteria to estimate the relaxation time T1 faster than with a multipoint method leading to...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00092-2

    authors: Imran J,Langevin F,Saint-Jalmes H

    更新日期:1999-11-01 00:00:00

  • Flexible, phase-matched, linear receive arrays for high-field MRI in monkeys.

    abstract::High signal-to-noise ratios (SNR) are essential for high-resolution anatomical and functional MRI. Phased arrays are advantageous for this but have the drawback that they often have inflexible and bulky configurations. Particularly in experiments where functional MRI is combined with simultaneous electrophysiology, sp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.03.026

    authors: Goense J,Logothetis NK,Merkle H

    更新日期:2010-10-01 00:00:00

  • Spectroscopic imaging of the brain with phased-array coils at 3.0 T.

    abstract::The goal of this study was to develop and evaluate high-resolution magnetic resonance spectroscopic imaging (MRSI) utilizing the gains in signal-to-noise ratio (SNR) provided by combining higher magnetic field with high-sensitivity phased-array (PA) coils. We investigated the maximum improvement in spatial resolution ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.019

    authors: Xu D,Chen AP,Cunningham C,Osorio JA,Nelson SJ,Vigneron DB

    更新日期:2006-01-01 00:00:00

  • The relaxivity of Gd-EOB-DTPA and Gd-DTPA in liver and kidney of the Wistar rat.

    abstract::The NMR relaxivities of Gd-EOB-DTPA and Gd-DTPA were determined in the kidney and liver of intact male Wistar rats immediately following sacrifice and in vitro in solutions and gels, at 1.5 T using a clinical MR scanner, T1 and T2 values of tissue samples were derived from spin-echo image sequences. Tissue gadolinium ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02097-d

    authors: Shuter B,Tofts PS,Wang SC,Pope JM

    更新日期:1996-01-01 00:00:00

  • A simple method for MR elastography: a gradient-echo type multi-echo sequence.

    abstract::To demonstrate the feasibility of a novel MR elastography (MRE) technique based on a conventional gradient-echo type multi-echo MR sequence which does not need additional bipolar magnetic field gradients (motion encoding gradient: MEG), yet is sensitive to vibration. In a gradient-echo type multi-echo MR sequence, sev...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.10.002

    authors: Numano T,Mizuhara K,Hata J,Washio T,Homma K

    更新日期:2015-01-01 00:00:00

  • MR imaging of cervical spine motion with HASTE.

    abstract::The HASTE (half-Fourier acquisition single-shot turbo spin-echo) technique delivers images with T2-weighting in about half a second and could be ideal for fast dynamic studies when T2-weighting is needed. We evaluated cardiac-triggered HASTE to study cervical spine flexion/extension. The cervical spines of ten asympto...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00176-3

    authors: Duerinckx AJ,Yu WD,El-Saden S,Kim D,Wang JC,Sandhu HS

    更新日期:1999-04-01 00:00:00

  • Increased confidence of diagnosis of Ewing sarcoma using T2-weighted MR images.

    abstract::To assess whether magnetic resonance imaging could assist in diagnosing Ewing sarcoma, we retrospectively analyzed T1- and T2-weighted images of 24 consecutive solitary lytic bone lesions, including 18 cases of histologically proven Ewing sarcoma, and six aggressive-appearing benign lesions including eosinophilic gran...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92450-3

    authors: Hanna SL,Fletcher BD,Kaste SC,Fairclough DL,Parham DM

    更新日期:1994-01-01 00:00:00

  • Accurate and sensitive measurements of magnetic susceptibility using echo planar imaging.

    abstract::Susceptibility differences are common causes for artifacts in magnetic resonance (MR); therefore, it is important to choose phantom materials in a way that these artifacts are kept at a minimum. In this study, a previously proposed MR imaging (MRI) method [Beuf O, Briguet A, Lissac M, Davis R. Magnetic resonance imagi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.07.005

    authors: Carlsson A,Starck G,Ljungberg M,Ekholm S,Forssell-Aronsson E

    更新日期:2006-11-01 00:00:00

  • Effect of slice orientation on reproducibility of fMRI motor activation at 3 Tesla.

    abstract::The effect of slice orientation on reproducibility and sensitivity of 3T fMRI activation using a motor task has been investigated in six normal volunteers. Four slice orientations were used; axial, oblique axial, coronal and sagittal. We applied analysis of variance (ANOVA) to suprathreshold voxel statistics to quanti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00399-x

    authors: Gustard S,Fadili J,Williams EJ,Hall LD,Carpenter TA,Brett M,Bullmore ET

    更新日期:2001-12-01 00:00:00

  • High-resolution magnetic resonance flow imaging in a model of porous bone-implant interface.

    abstract:PURPOSE:To evaluate the application of high-resolution MRI methodology for characterizing the fluid velocity field and evaluate fluid shear field within a simplified in vitro model of a bone-implant interface. MATERIALS AND METHODS:The study used a specific micromotion canine bone implant that has been used for over a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.11.001

    authors: Conroy MJ,Pédrono A,Bechtold JE,Søballe K,Ambard D,Swider P

    更新日期:2006-06-01 00:00:00

  • Identification of an optimal threshold for detecting human brown adipose tissue using receiver operating characteristic analysis of IDEAL MRI fat fraction maps.

    abstract:PURPOSE:Lower fat fraction (FF) in brown adipose tissue (BAT) than white adipose tissue (WAT) has been exploited using Dixon-based Magnetic Resonance Imaging (MRI) to differentiate these tissues in rodents, human infants and adults. We aimed to determine whether an optimal FF threshold could be determined to differenti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.04.013

    authors: Jones TA,Wayte SC,Reddy NL,Adesanya O,Dimitriadis GK,Barber TM,Hutchinson CE

    更新日期:2018-09-01 00:00:00

  • The comparison of the performance of 3 T and 7 T T2 mapping for untreated low-grade cartilage lesions.

    abstract:OBJECTIVE:To investigate T2 mapping as a possible marker for low-grade human articular cartilage lesions during a one-year follow-up, possible changes during the follow-up and compare the reliability and sensitivity of these measurements on high-field (3 T) and ultra-high-field (7 T) MRI scanners. DESIGN:Twenty-one pa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.09.021

    authors: Juras V,Schreiner M,Laurent D,Zbýň Š,Mlynarik V,Szomolanyi P,Hager B,Scotti C,Goldhahn J,Heule R,Bieri O,Trattnig S

    更新日期:2019-01-01 00:00:00

  • A simulation-based comparison of two methods for determining relaxation rates from relaxometry images.

    abstract::When assessing liver iron content using relaxometry, an average relaxation rate (R1, R2 or R2*) is usually determined from a region of interest or the entire liver. This is commonly performed by fitting the signal decay in individual voxels to an appropriate relaxation function. The voxel-level parameters resulting fr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.11.005

    authors: Marro K,Otto R,Kolokythas O,Shimamura A,Sanders JE,McDonald GB,Friedman SD

    更新日期:2011-05-01 00:00:00

  • Multispectral analysis of bone lesions in the hands of patients with rheumatoid arthritis.

    abstract::Quantitative measures of rheumatoid arthritis (RA) disease progression can provide valuable tools for evaluation of new treatments during clinical trials. In this study, a novel multispectral (MS) MRI analysis method is presented to quantify changes in bone lesion volume (DeltaBLV) in the hands of RA patients. Image r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.013

    authors: Carano RA,Lynch JA,Redei J,Ostrowitzki S,Miaux Y,Zaim S,White DL,Peterfy CG,Genant HK

    更新日期:2004-05-01 00:00:00

  • Balanced multi-image demons for non-rigid registration of magnetic resonance images.

    abstract::A new approach is introduced for non-rigid registration of a pair of magnetic resonance images (MRI). It is a generalization of the demons algorithm with low computational cost, based on local information augmentation (by integrating multiple images) and balanced implementation. Specifically, a single deformation that...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.09.013

    authors: Mesin L

    更新日期:2020-12-01 00:00:00

  • Quantitative determination of porosity: a local assessment by NMR imaging techniques.

    abstract::The local determination of porosity is an extremely valuable target because of different applications in petrophysics. In fact, obtaining a reliable profile of porosity or saturations could considerably improve the evaluation of transport properties of porous media, especially if applied to multiphase flow test (i.e.,...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00182-8

    authors: Borgia GC,Bortolotti V,Dattilo P,Fantazzini P,Maddinelli G

    更新日期:1996-01-01 00:00:00

  • Increasing mean airway pressure reduces functional MRI (fMRI) signal in the primary visual cortex.

    abstract::Changes in both blood flow and blood oxygenation determine the functional MRI (fMRI) signal. In the present study factors responsible for blood oxygenation (e.g., FiO(2)) were held constant so that changes in pixel count would above all reflect changes in regional cerebral blood flow (rCBF). Continuous positive airway...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00229-0

    authors: Lorenz IH,Kolbitsch C,Hörmann C,Schocke M,Kremser C,Zschiegner F,Felber S,Benzer A

    更新日期:2001-01-01 00:00:00

  • Factors influencing contrast in fast spin-echo MR imaging.

    abstract::Multi-echo pulse sequences for producing T2-weighted images in much reduced imaging times have recently been developed for routine clinical use. A number of recent articles have described the contrast obtained with fast spin-echo (FSE) sequences and have generally indicated that they depict tissues very similarly to c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(92)90001-g

    authors: Constable RT,Anderson AW,Zhong J,Gore JC

    更新日期:1992-01-01 00:00:00

  • A new NOE-mediated MT signal at around -1.6ppm for detecting ischemic stroke in rat brain.

    abstract::In the present work, we reported a new nuclear Overhauser enhancement (NOE)-mediated magnetization transfer (MT) signal at around -1.6ppm (NOE(-1.6)) in rat brain and investigated its application in the detection of acute ischemic stroke in rodent model. Using continuous wave (CW) MT sequence, the NOE(-1.6) is reliabl...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.05.002

    authors: Zhang XY,Wang F,Afzal A,Xu J,Gore JC,Gochberg DF,Zu Z

    更新日期:2016-10-01 00:00:00

  • 1H magnetic resonance imaging and 31P magnetic resonance spectroscopy in experimental filariasis.

    abstract::1H Magnetic resonance imaging and 31P magnetic resonance spectroscopy (MRS) have been carried out in experimental rodent filariasis, i.e., Acanthocheilonema viteae infection in the rodent host, Mastomys coucha. The T2-weighted image of the infected host shows fine hyperintense thread like structures of adult filariid ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00180-x

    authors: Shukla-Dave A,Fatma N,Roy R,Srivastava S,Chatterjee RK,Govindaraju V,Viswanathan AK,Raghunathan P

    更新日期:1997-01-01 00:00:00

  • Parametric multiecho proton spectroscopic imaging: application to the rat brain in vivo.

    abstract::A parametric multiecho variant of proton spectroscopic imaging (SI) is presented using a multiecho SI sequence with uniform phase-encoding of all echoes within each echo train. The acquisition of SI data sets at different echo times (TE) increases the amount of information obtained within the same total measuring time...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00027-e

    authors: Dreher W,Leibfritz D

    更新日期:1995-01-01 00:00:00

  • Reaction of gadolinium chelates with endogenously available ions.

    abstract::The extent of reaction of 153Gd-radiolabeled Gd(L) chelates with 25 mM CO23- (25 mF), PO34-, Zn2+ and Cu2+ at pH 7 was determined for L = EDTA, DTPA, DOTA, HP-DO3A, and DO3A. Gd(EDTA)- and Gd(DTPA)2- reacted (greater than 20% in 10 min) with Cu2+ and Zn2+ in the presence of PO34-. These double replacement reactions yi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90429-p

    authors: Tweedle MF,Hagan JJ,Kumar K,Mantha S,Chang CA

    更新日期:1991-01-01 00:00:00

  • Effects of spatial smoothing on fMRI group inferences.

    abstract::The analysis of functional magnetic resonance imaging (fMRI) data involves multiple stages of data pre-processing before the activation can be statistically detected. Spatial smoothing is a very common pre-processing step in the analysis of functional brain imaging data. This study presents a broad perspective on the ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.08.006

    authors: Mikl M,Marecek R,Hlustík P,Pavlicová M,Drastich A,Chlebus P,Brázdil M,Krupa P

    更新日期:2008-05-01 00:00:00

  • Reducing motion artifacts in two-dimensional Fourier transform imaging.

    abstract::The effects of motion in two-dimensional Fourier transform imaging (2DFT) are considered. Specific calculations describing the case of periodic motion are presented. The results predict the commonly seen artifact of image replication, sometimes referred to as ghosting. Expressions for both position and amplitude of th...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(86)91046-5

    authors: Haacke EM,Patrick JL

    更新日期:1986-01-01 00:00:00

  • Artifacts in chemical shift selective imaging.

    abstract::The role of susceptibility effects in the production of artifacts in chemical shift images generated by the selective excitation technique is discussed. The effects are demonstrated in images of phantom samples of agarose gels containing small air bubbles. The artifacts can lead to erroneous interpretations, in which ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90022-r

    authors: Pope JM,Walker RR,Kron T

    更新日期:1992-01-01 00:00:00