A new NOE-mediated MT signal at around -1.6ppm for detecting ischemic stroke in rat brain.

Abstract:

:In the present work, we reported a new nuclear Overhauser enhancement (NOE)-mediated magnetization transfer (MT) signal at around -1.6ppm (NOE(-1.6)) in rat brain and investigated its application in the detection of acute ischemic stroke in rodent model. Using continuous wave (CW) MT sequence, the NOE(-1.6) is reliably detected in rat brain. The amplitude of this new NOE signal in rat brain was quantified using a 5-pool Lorentzian Z-spectral fitting method. Amplitudes of amide, amine, NOE at -3.5ppm (NOE(-3.5)), as well as NOE(-1.6) were mapped using this fitting method in rat brain. Several other conventional imaging parameters (R1, R2, apparent diffusion coefficient (ADC), and semi-solid pool size ratio (PSR)) were also measured. Our results show that NOE(-1.6), R1, R2, ADC, and APT signals from stroke lesion have significant changes at 0.5-1h after stroke. Compared with several other imaging parameters, NOE(-1.6) shows the strongest contrast differences between stroke and contralateral normal tissues and stays consistent over time until 2h after onset of stroke. Our results demonstrate that this new NOE(-1.6) signal in rat brain is a new potential contrast for assessment of acute stroke in vivo and might provide broad applications in the detection of other abnormal tissues.

journal_name

Magn Reson Imaging

authors

Zhang XY,Wang F,Afzal A,Xu J,Gore JC,Gochberg DF,Zu Z

doi

10.1016/j.mri.2016.05.002

subject

Has Abstract

pub_date

2016-10-01 00:00:00

pages

1100-6

issue

8

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(16)30048-0

journal_volume

34

pub_type

杂志文章
  • Strategies for reducing large fMRI data sets for independent component analysis.

    abstract::In independent component analysis (ICA), principal component analysis (PCA) is generally used to reduce the raw data to a few principal components (PCs) through eigenvector decomposition (EVD) on the data covariance matrix. Although this works for spatial ICA (sICA) on moderately sized fMRI data, it is intractable for...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.013

    authors: Wang Z,Wang J,Calhoun V,Rao H,Detre JA,Childress AR

    更新日期:2006-06-01 00:00:00

  • 3D MR image denoising using rough set and kernel PCA method.

    abstract::In this paper, we have presented a two stage method, using kernel principal component analysis (KPCA) and rough set theory (RST), for denoising volumetric MRI data. A rough set theory (RST) based clustering technique has been used for voxel based processing. The method groups similar voxels (3D cubes) using class and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.10.010

    authors: Phophalia A,Mitra SK

    更新日期:2017-02-01 00:00:00

  • Measuring pore connectivity by pulsed field gradient diffusion editing with hydrocarbon gases.

    abstract::Measurements of time-dependent diffusion are performed on a rock sample saturated first with water, then methane and finally ethane. The gases were selected because their increased diffusivities and relaxation times allow probing greater length scales than water and because of their practical relevance. The nuclear ma...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.01.002

    authors: Flaum M,Hirasaki GJ,Flaum C,Straley C

    更新日期:2005-02-01 00:00:00

  • Dual-echo breathhold T(2)-weighted fast spin echo MR imaging of liver lesions.

    abstract::The purpose of this study was to develop a multi-shot dual-echo breathhold fast spin echo technique (DFSE) and compare it with conventional spin echo (T2SE) for T(2)-weighted MR imaging of liver lesions. The DFSE acquisition (EffTE1/EffTE2/TR = 66/143/2100 ms) imaged 5 sections per 17 s breathhold. T2SE imaging (TE1/T...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00120-4

    authors: Rydberg JN,Tervonen OA,Rydberg DB,Lomas DJ,Ehman RL,Riederer SJ

    更新日期:2000-02-01 00:00:00

  • Simple phase method for measurement of magnetic field gradient waveforms.

    abstract::Magnetic field gradients play a fundamental role in MR imaging and localized spectroscopy. The MRI experiment, in particular fast MRI, relies on precise gradient switching, which has become more demanding with the constantly growing number of fast imaging techniques. Here we present a simple MR method to measure the b...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.02.002

    authors: Latta P,Gruwel ML,Volotovskyy V,Weber MH,Tomanek B

    更新日期:2007-11-01 00:00:00

  • Quantitative computer-assisted analysis vs. visual estimation of MR imaging response of brain metastases to radiotherapy.

    abstract::Using both quantitative computer-assisted analysis and visual estimation the MR imaging response of brain metastases to whole-brain radiotherapy (WBRT) was prospectively studied in 49 patients. Compared to the computer-assisted analysis, the precision of the visual estimation (by two readers in conference) of tumor re...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00024-0

    authors: Taphoorn MJ,Potman RA,Barkhof F,Weerts JG,Valk J,Karim AB,Heimans JJ

    更新日期:1997-01-01 00:00:00

  • Pulseq-Graphical Programming Interface: Open source visual environment for prototyping pulse sequences and integrated magnetic resonance imaging algorithm development.

    abstract:PURPOSE:To provide a single open-source platform for comprehensive MR algorithm development inclusive of simulations, pulse sequence design and deployment, reconstruction, and image analysis. METHODS:We integrated the "Pulseq" platform for vendor-independent pulse programming with Graphical Programming Interface (GPI)...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.03.008

    authors: Ravi KS,Potdar S,Poojar P,Reddy AK,Kroboth S,Nielsen JF,Zaitsev M,Venkatesan R,Geethanath S

    更新日期:2018-10-01 00:00:00

  • A simple analytic method for estimating T2 in the knee from DESS.

    abstract:PURPOSE:To introduce a simple analytical formula for estimating T2 from a single Double-Echo in Steady-State (DESS) scan. METHODS:Extended Phase Graph (EPG) modeling was used to develop a straightforward linear approximation of the relationship between the two DESS signals, enabling accurate T2 estimation from one DES...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.12.018

    authors: Sveinsson B,Chaudhari AS,Gold GE,Hargreaves BA

    更新日期:2017-05-01 00:00:00

  • Factors affecting nitroxide reduction in ascorbate solution and tissue homogenates.

    abstract::Because of their paramagnetic properties, nitroxides are potentially useful as contrast agents in magnetic resonance imaging (MRI). They are reduced in vivo to their corresponding hydroxylamines which are nonparamagnetic and have no contrast enhancing property. Nitroxides with high resistance to reduction would be adv...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(85)90012-8

    authors: Couet WR,Brasch RC,Sosnovsky G,Tozer TN

    更新日期:1985-01-01 00:00:00

  • Adaptive segmentation of magnetic resonance images with intensity inhomogeneity using level set method.

    abstract::It is a big challenge to segment magnetic resonance (MR) images with intensity inhomogeneity. The widely used segmentation algorithms are region based, which mostly rely on the intensity homogeneity, and could bring inaccurate results. In this paper, we propose a novel region-based active contour model in a variationa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.10.010

    authors: Liu L,Zhang Q,Wu M,Li W,Shang F

    更新日期:2013-05-01 00:00:00

  • MRI appearance of disseminated osseous tuberculosis.

    abstract::Disseminated osseous tuberculosis is a rare disease. This is a report of two cases of disseminated osseous tuberculosis imaged with MRI at 1.5-T, CT, plain radiography and bone scintigraphy. CT and plain radiography demonstrated either highly destructive or cystic lesions with sclerotic margins. Bone scintigraphy and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90384-5

    authors: Quinn SF,Murray W,Prochaska J,Cochran C,Clark R

    更新日期:1987-01-01 00:00:00

  • A robust electrical conductivity imaging method with total variation and wavelet regularization.

    abstract:PURPOSE:This study aims to develop and evaluate a robust conductivity imaging method that combines total variation and wavelet regularization to enhance the accuracy of conductivity maps. THEORY AND METHODS:The proposed approach is based on a gradient-based method. The central equation is derived from Maxwell's equati...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.02.015

    authors: Sun X,Lu L,Qi L,Mei Y,Liu X,Chen W

    更新日期:2020-06-01 00:00:00

  • 1H magnetic resonance imaging and 31P magnetic resonance spectroscopy in experimental filariasis.

    abstract::1H Magnetic resonance imaging and 31P magnetic resonance spectroscopy (MRS) have been carried out in experimental rodent filariasis, i.e., Acanthocheilonema viteae infection in the rodent host, Mastomys coucha. The T2-weighted image of the infected host shows fine hyperintense thread like structures of adult filariid ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00180-x

    authors: Shukla-Dave A,Fatma N,Roy R,Srivastava S,Chatterjee RK,Govindaraju V,Viswanathan AK,Raghunathan P

    更新日期:1997-01-01 00:00:00

  • Considerations in applying 3D PRESS H-1 brain MRSI with an eight-channel phased-array coil at 3 T.

    abstract::The purpose of this study was to assess the benefits of a 3 T scanner and an eight-channel phased-array head coil for acquiring three-dimensional PRESS (Point REsolved Spectral Selection) proton (H-1) magnetic resonance spectroscopic imaging (MRSI) data from the brains of volunteers and patients with brain tumors rela...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.07.012

    authors: Li Y,Osorio JA,Ozturk-Isik E,Chen AP,Xu D,Crane JC,Cha S,Chang S,Berger MS,Vigneron DB,Nelson SJ

    更新日期:2006-12-01 00:00:00

  • Superparamagnetic iron oxide particles and positive enhancement for myocardial perfusion studies assessed by subsecond T1-weighted MRI.

    abstract::Superparamagnetic iron oxide particles (SPIOs) are usually referred to as T2 MR contrast agents, reducing signal intensity (SI) on T2-weighted MR images (negative enhancement). This study reports the original use of SPIOs as T1-enhancing contrast agents, primarily assessed in vitro, and then applied to an in vivo inve...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90241-5

    authors: Canet E,Revel D,Forrat R,Baldy-Porcher C,de Lorgeril M,Sebbag L,Vallee JP,Didier D,Amiel M

    更新日期:1993-01-01 00:00:00

  • GPU-accelerated nonparametric kinetic analysis of DCE-MRI data from glioblastoma patients treated with bevacizumab.

    abstract::Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is often used to examine vascular function in malignant tumors and noninvasively monitor drug efficacy of antivascular therapies in clinical studies. However, complex numerical methods used to derive tumor physiological properties from DCE-MRI images can b...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.09.007

    authors: Hsu YH,Ferl GZ,Ng CM

    更新日期:2013-05-01 00:00:00

  • Reproducibility of simultaneous imaging of intracranial and extracranial arterial vessel walls using an improved T1-weighted DANTE-SPACE sequence on a 3 T MR system.

    abstract:PURPOSE:To systematically investigate the scan-rescan, intra-observer, and inter-observer reproducibility of an improved DANTE-SPACE sequence for the simultaneous assessment of intra- and extracranial arterial vessel wall morphology. MATERIALS AND METHODS:Thirty-five healthy volunteers and 10 patients with atheroscler...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.04.016

    authors: Wan L,Zhang N,Zhang L,Long X,Jia S,Li Y,Liang D,Zheng H,Liu X

    更新日期:2019-10-01 00:00:00

  • A CT using longitudinally detected ESR (LODESR-CT) of intraperitoneally injected nitroxide radical in a rat's head.

    abstract::We have developed an in vivo longitudinally detected ESR (LODESR) imaging system operating at 700 MHz based on a loop-gap resonator and a pair of saddle-type pickup coils. A good linear relationship between the LODESR signal intensity and the applied power in a range up to 15.8 W was obtained. The detection of LODESR ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)82763-4

    authors: Yokoyama H,Sato T,Tsuchihashi N,Ogata T,Ohya-Nishiguchi H,Kamada H

    更新日期:1997-01-01 00:00:00

  • Identification of an optimal threshold for detecting human brown adipose tissue using receiver operating characteristic analysis of IDEAL MRI fat fraction maps.

    abstract:PURPOSE:Lower fat fraction (FF) in brown adipose tissue (BAT) than white adipose tissue (WAT) has been exploited using Dixon-based Magnetic Resonance Imaging (MRI) to differentiate these tissues in rodents, human infants and adults. We aimed to determine whether an optimal FF threshold could be determined to differenti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.04.013

    authors: Jones TA,Wayte SC,Reddy NL,Adesanya O,Dimitriadis GK,Barber TM,Hutchinson CE

    更新日期:2018-09-01 00:00:00

  • Parametric multiecho proton spectroscopic imaging: application to the rat brain in vivo.

    abstract::A parametric multiecho variant of proton spectroscopic imaging (SI) is presented using a multiecho SI sequence with uniform phase-encoding of all echoes within each echo train. The acquisition of SI data sets at different echo times (TE) increases the amount of information obtained within the same total measuring time...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00027-e

    authors: Dreher W,Leibfritz D

    更新日期:1995-01-01 00:00:00

  • Ferumoxide-enhanced MRI in patients with colorectal cancer and rising CEA: surgical correlation in early recurrence.

    abstract::The purpose of this study was to evaluate the value of Ferumoxide-enhanced magnetic resonance (MR) imaging in the detection of hepatic metastases in high-risk patients treated for colorectal cancer that have rising CEA. We used 19 patients treated previously for colorectal cancer with rising CEA levels underwent an un...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0730-725x(99)00134-4

    authors: Said B,McCart JA,Libutti SK,Choyke PL

    更新日期:2000-04-01 00:00:00

  • Three dimensional texture analysis in MRI: a preliminary evaluation in gliomas.

    abstract::The discrimination of tumor boundaries from normal tissue, as well as the evaluation of tissue heterogeneity and tumor grading often continue to pose a challenge in MRI. Although yielding promising results in various fields of medical imaging, two- dimensional (2D) texture analysis in MRI has, until now, demonstrated ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00201-7

    authors: Mahmoud-Ghoneim D,Toussaint G,Constans JM,de Certaines JD

    更新日期:2003-11-01 00:00:00

  • Non-contrast-enhanced MR angiography in the diagnosis of Budd-Chiari syndrome (BCS) compared with digital subtraction angiography (DSA): Preliminary results.

    abstract::Non-CE MRA techniques (true steady-state free-precession, SSFP) have been used effectively for the selective visualization of the portal venous system and inferior vena cava. Budd-Chiari Syndrome (BCS) encompasses a number of conditions that cause the obstruction of the hepatic outflow tract from the small hepatic vei...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.10.006

    authors: Yang C,Li C,Zeng M,Lu X,Li J,Wang J,Sami MU,Xu K

    更新日期:2017-02-01 00:00:00

  • MR angiography of meningioma.

    abstract::The clinical evaluation of three-dimensional time-of-flight MR angiography was prospectively performed in 16 patients with intracranial meningioma. MR angiographic techniques used in this study both with and without gadopentetate dimeglumine made it possible to demonstrate the topographic relationship between the tumo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90466-q

    authors: Kadota T,Kuriyama K,Inoue E,Fujita M,Nakagawa H,Kuroda C

    更新日期:1993-01-01 00:00:00

  • Off-resonance frequency filtered magnetic resonance imaging.

    abstract::One of the main problems with rapid magnetic resonance imaging (MRI) techniques is the artifacts that result from off-resonance effects. The proposed off-resonance frequency filtered MRI (OFF-MRI) method focuses on the elimination of off-resonance components from the image of the observed object. To maintain imaging s...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.12.027

    authors: Medic J,Tomazic S

    更新日期:2010-05-01 00:00:00

  • MRI-guided breast vacuum biopsy: Localization of the lesion without contrast-agent application using diffusion-weighted imaging.

    abstract:OBJECTIVE:In magnetic resonance-guided breast vacuum biopsies, the contrast agent for targeting suspicious lesions can typically be applied only once during an intervention, due to the slow elimination of the gadolinium chelate from the extracellular fluid space. This study evaluated the feasibility of diffusion-weight...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.12.006

    authors: Berger N,Varga Z,Frauenfelder T,Boss A

    更新日期:2017-05-01 00:00:00

  • The Elgin marvel: using magnetic resonance imaging to look at a moldic fossil from the Permian of Elgin, Scotland, UK.

    abstract::The successful use of magnetic resonance imaging (MRI) of a moldic fossil dicynodont from the Permian aeolian Hopeman Sandstone Formation of Elgin, Scotland, UK, provides paleontologists with a nondestructive technique for examining fossils preserved in this fashion. For large moldic fossils, medical scanners such as ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.09.006

    authors: Clark ND,Adams C,Lawton T,Cruickshank AR,Woods K

    更新日期:2004-02-01 00:00:00

  • Diffusion of water in industrial cement and concrete.

    abstract::We propose a deuterium diffusion tracer approach to measure diffusion coefficient in the case of very short NMR relaxation times, too short for NMR pulsed field gradient sequences (T1 or T2 below 1 ms). We also treat the case of porous media containing metallic fibers (such as reinforced concrete) strongly disturbing ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.09.010

    authors: Fleury M,Berthe G,Chevalier T

    更新日期:2019-02-01 00:00:00

  • Automatic motion correction of Musculoskeletal MRI using DSLR camera.

    abstract::The purpose of this study is to illustrate motion correction in Musculoskeletal (MSK) Magnetic Resonance Imaging (MRI) through utilization of information from an optical tracker to capture the extent and instant of motion. A Digital Single Lens Reflexive camera is employed as the optical tracker to capture the extent ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.12.031

    authors: Chikop SA,Anchan ABS,Koulagi G,Honnedevasthana AA,Imam S,Geethanath S

    更新日期:2018-05-01 00:00:00

  • Noninvasive evaluation of radiation-enhanced glioma cells invasiveness by ultra-high-field (1)H-MRS in vitro.

    abstract:INTRODUCTION:Glioma is the most common type of the primary CNS tumor. Radiotherapy is an important treatment measure after surgery. However, its highly invasive character is the main reason of postoperative recurrence. The aim of the study was to probe the correlation between the invasion ability and the metabolite cha...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.05.009

    authors: Xu YJ,Cui Y,Li HX,Shi WQ,Li FY,Wang JZ,Zeng QS

    更新日期:2016-10-01 00:00:00