Abstract:
OBJECTIVE:In magnetic resonance-guided breast vacuum biopsies, the contrast agent for targeting suspicious lesions can typically be applied only once during an intervention, due to the slow elimination of the gadolinium chelate from the extracellular fluid space. This study evaluated the feasibility of diffusion-weighted imaging (DWI) for lesion targeting in vacuum assisted magnetic resonance imaging (MRI) biopsies. CONCLUSION:DWI may be used as an alternative to dynamic contrast-enhanced MRI with the advantage of reproducibility. However, the targeted lesion requires the characteristics of a mass-like lesion, substantial diffusion restriction, and a minimum size of approximately 1cm.
journal_name
Magn Reson Imagingjournal_title
Magnetic resonance imagingauthors
Berger N,Varga Z,Frauenfelder T,Boss Adoi
10.1016/j.mri.2016.12.006subject
Has Abstractpub_date
2017-05-01 00:00:00pages
1-5eissn
0730-725Xissn
1873-5894pii
S0730-725X(16)30241-7journal_volume
38pub_type
杂志文章abstract::Blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) is currently the dominant technique for non-invasive investigation of brain functions. One of the challenges with BOLD fMRI, particularly at high fields, is compensation for the effects of spatiotemporally varying magnetic field inho...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2009.07.005
更新日期:2010-02-01 00:00:00
abstract::Merkel cell carcinoma (MCC) is a rare malignant tumor of the skin and often is diagnosed histologically as lymphoma, melanoma and even metastatic small cell carcinoma of the lung (SCCL). Classified as a neuroendocrine tumor, clinically it originates in the head and neck region and may present with metastatic disease a...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(00)00176-4
更新日期:2000-10-01 00:00:00
abstract::We examined if MR diffusion tensor imaging with fiber tracking could be performed on the sciatic nerve. In 3 healthy volunteers the proximal thigh was examined on a 1.5-Tesla MR-scanner with a 2-channel phased-array coil. Though inherently susceptible to motion, field inhomogeneities, and fast T(2)-relaxation of the d...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2004.01.073
更新日期:2004-06-01 00:00:00
abstract:PURPOSE:To introduce a simple analytical formula for estimating T2 from a single Double-Echo in Steady-State (DESS) scan. METHODS:Extended Phase Graph (EPG) modeling was used to develop a straightforward linear approximation of the relationship between the two DESS signals, enabling accurate T2 estimation from one DES...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.12.018
更新日期:2017-05-01 00:00:00
abstract::Multiparametric MRI is a remarkable imaging method for the assessment of patho-physiological processes. In particular, brain tumor characterization has taken advantage of the development of advanced techniques such as Diffusion- (DWI) and Perfusion- (PWI) Weighted Imaging, but a thorough analysis of meningiomas is sti...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.12.003
更新日期:2020-04-01 00:00:00
abstract:BACKGROUND:Doppler based mitral annular velocities are an integral part of echocardiographic left ventricular diastolic function assessment. Although these measurements can be obtained by phase contrast cardiac magnetic resonance imaging (PC-CMR), this approach has limitations. The aims of this study were to assess the...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2018.08.018
更新日期:2019-01-01 00:00:00
abstract::Magic-angle sample spinning is one of the cornerstones in high-resolution NMR of solid and semisolid materials. The technique enhances spectral resolution by averaging away rank 2 anisotropic spin interactions, thereby producing isotropic-like spectra with resolved chemical shifts and scalar couplings. In principle, i...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2004.11.067
更新日期:2005-02-01 00:00:00
abstract::Partial volume effects in proton magnetic resonance spectroscopy in the brain have been studied previously in terms of proper water concentration calculations, but there is a lack of disclosure in terms of voxel placement techniques that would affect the calculations. The purpose of this study is to facilitate a fully...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2013.04.001
更新日期:2013-09-01 00:00:00
abstract:INTRODUCTION:Recent animal and human epidemiological studies suggest that early childhood exposure to anesthesia may have adverse effects on brain development. As more than 50% of pregnant women in the United States and one-third in the United Kingdom receive regional anesthesia during labor and delivery, understanding...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2014.08.033
更新日期:2015-02-01 00:00:00
abstract::We compared the efficacy of rapidly acquired magnetization prepared gradient-echo (MP-GRE) sequences with CT and standard MRI pulse sequences for the detection of focal liver lesions. Fourteen patients with 28 focal liver lesions were scanned. TI times of 300, 450, and 600 ms were used. MP-GRE lesion conspicuity was c...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)92198-9
更新日期:1994-01-01 00:00:00
abstract::Quantitative analysis has tremendous but mostly unrealized potential in healthcare to support objective and accurate interpretation of the clinical imaging. In 2008, the National Cancer Institute began building the Quantitative Imaging Network (QIN) initiative with the goal of advancing quantitative imaging in the con...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2012.05.001
更新日期:2012-11-01 00:00:00
abstract::A new application of the stimulated echo pulse sequence is presented that permits the elucidation of molecular order and dynamics in a time scale between about 100 microseconds and the spin-lattice relaxation time. The technique exploits the influence of dipolar coupling on the quotient of the stimulated and primary e...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(96)00172-5
更新日期:1996-01-01 00:00:00
abstract::Blood circulation is an important determinant of the biodistribution of superparamagnetic iron oxide nanoparticles. Here we present a magnetic resonance imaging (MRI) technique based on the use of ultrafast echo times (UTE) for the noninvasive determination of blood half-lives at high particle concentrations, when con...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2015.06.017
更新日期:2015-11-01 00:00:00
abstract:PURPOSE:The purpose of this study was to determine the pre- and postpubertal 1H magnetic resonance spectroscopic characteristics of the normal testis to establish baseline values for further clinical studies. MATERIALS AND METHODS:The subjects consisted of male volunteers, of whom 19 were prepubertal with ages between...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2007.06.008
更新日期:2008-02-01 00:00:00
abstract::Automatic segmentation of different types of tissue from magnetic resonance images is of great importance for clinical and research applications, particularly large-scale and longitudinal studies of brain pathology. We developed a fully automated algorithm for the segmentation of lateral ventricles from cranial magnet...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2006.08.013
更新日期:2006-12-01 00:00:00
abstract::A new pulse sequence for estimating cerebral blood flow called UNFAIR, which uses a combination of sequential hyperbolic secant preparatory pulses, is introduced. This sequence is based on the same generalized conditions as previously introduced inversion recovery techniques except that the spins in the image slice of...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(96)00353-0
更新日期:1997-01-01 00:00:00
abstract::Changes in both blood flow and blood oxygenation determine the functional MRI (fMRI) signal. In the present study factors responsible for blood oxygenation (e.g., FiO(2)) were held constant so that changes in pixel count would above all reflect changes in regional cerebral blood flow (rCBF). Continuous positive airway...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(00)00229-0
更新日期:2001-01-01 00:00:00
abstract::A variety of shortcomings are associated with most currently used gastrointestinal contrast agents for magnetic resonance imaging (MRI). Artifacts resulting from peristalsis and other motions in the abdominal region are produced by many positive contrast agents (which increase signal intensity). Although this is not a...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(97)00020-9
更新日期:1997-01-01 00:00:00
abstract::We propose a novel processing method for reducing shading artifacts in quantitative susceptibility mapping (QSM) for prostate imaging. In the conventional method, calculation errors in the boundary regions between water and fat cause shading artifacts that degrade the image quality for QSM. In the proposed method, wat...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.11.006
更新日期:2020-02-01 00:00:00
abstract:OBJECTIVES:To investigate the feasibility of chemical exchange saturation transfer (CEST) MRI in patients with breast carcinomas and possible correlations between magnetization transfer asymmetry (MTRasym) values and histological features, such as tumor grade and the Ki-67 proliferation index. MATERIALS AND METHODS:Ni...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.03.004
更新日期:2019-06-01 00:00:00
abstract::The location and masking of the brain and surrounding cerebrospinal fluid (CSF) in two-dimensional (2D) dual-echo fast spin-echo (FSE) magnetic resonance (MR) images of the head is achieved by an automated procedure with a voxel-based computational algorithm. Linear scale-space features are derived from the short-echo...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(98)00099-x
更新日期:1999-02-01 00:00:00
abstract::Surfactant adsorption layers on polystyrene latex particles are investigated concerning their equilibrium exchange dynamics with surfactant molecules in solution. Pulsed field gradient (PFG) nuclear magnetic resonance (NMR) self-diffusion measurements of the nonionic surfactant C12(EO)5 are performed, making use of th...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(98)00023-x
更新日期:1998-06-01 00:00:00
abstract::The NMR relaxivities of Gd-EOB-DTPA and Gd-DTPA were determined in the kidney and liver of intact male Wistar rats immediately following sacrifice and in vitro in solutions and gels, at 1.5 T using a clinical MR scanner, T1 and T2 values of tissue samples were derived from spin-echo image sequences. Tissue gadolinium ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(95)02097-d
更新日期:1996-01-01 00:00:00
abstract:OBJECTIVE:Equivalent cross-relaxation rate imaging (ECRI) is an MRI technique used to evaluate qualitative changes in protein-water interactions. We aimed to prospectively evaluate the utility of ECRI for classification of adipocytic tumors. MATERIALS AND METHODS:Institutional Review Board approval was obtained and al...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2013.12.004
更新日期:2014-04-01 00:00:00
abstract:PURPOSE:To evaluate the correlation between the pancreatic exocrine insufficiency estimated by cine-dynamic MRCP using spatially selective IR pulse and the severity stages (modified Cambridge classification) based on morphological changes of the pancreatic duct in patients with suspected chronic pancreatitis. MATERIAL...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2017.12.007
更新日期:2018-05-01 00:00:00
abstract:PURPOSE:The purpose was to validate diffusion-weighted imaging (DWI) in the assessment of hepatic metastases compared with superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance imaging. MATERIALS AND METHODS:For 21 consecutive patients with 160 metastases from extrahepatic malignancy and 25 benign focal lesi...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2011.12.007
更新日期:2012-05-01 00:00:00
abstract::Liver fibrosis determines the functional liver reserve. Several studies have reported that the apparent diffusion coefficient (ADC) values of diffusion-weighted magnetic resonance imaging (DW-MRI) can assess liver fibrosis. We investigated whether DW-MRI predicts postoperative hepatic insufficiency and liver fibrosis ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2010.03.018
更新日期:2010-07-01 00:00:00
abstract:PURPOSE:Our study aimed to develop accelerated microscopic diffusional kurtosis imaging (μDKI) and preliminarily evaluated it in a rodent model of chronic epilepsy. METHODS:We investigated two μDKI acceleration schemes of reduced sampling density and angular range in a phantom and wild-type rats, and further tested μD...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2018.10.009
更新日期:2019-02-01 00:00:00
abstract::Chemical exchange saturation transfer (CEST) MRI is increasingly used to probe mobile proteins and microenvironment properties, and shows great promise for tumor and stroke diagnosis. The CEST effect is complex and depends not only on the CEST agent concentration, exchange rates, the characteristic of the magnetizatio...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.02.001
更新日期:2016-07-01 00:00:00
abstract::Recently, we have demonstrated that the fine-digit topography (millimeter sized) previously identified in the primary somatosensory cortex (SI), using electrophysiology and intrinsic signal optical imaging, can also be mapped with submillimeter resolution using blood-oxygenation-level-dependent (BOLD) functional magne...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2007.05.002
更新日期:2007-07-01 00:00:00