Abstract:
PURPOSE:To systematically investigate the scan-rescan, intra-observer, and inter-observer reproducibility of an improved DANTE-SPACE sequence for the simultaneous assessment of intra- and extracranial arterial vessel wall morphology. MATERIALS AND METHODS:Thirty-five healthy volunteers and 10 patients with atherosclerotic plaque formation were each scanned twice using a T1-weighted DANTE-SPACE sequence on a 3 T MR system equipped with a 32-channel combined head and neck coil. Reproducibility analyses were performed for measurements of lumen and vessel wall volume, mean and maximum wall thickness, as well as for the normalized wall index. Intracranial and extracranial arterial segments were compared. RESULTS:Intra-class correlation coefficients (ICC) and Bland-Altman plots indicated good to excellent reproducibility for all morphologic measurements (all ICCs >0.77). In addition, the range of ICCs of extracranial arteries (0.80-0.99) was significant higher than that of intracranial arteries (0.77-0.98, P = 0.003). The range of ICCs of patients (0.79-0.99) was generally higher than that of volunteers (0.77-0.99, P = 0.47), especially for extracranial arteries. CONCLUSIONS:The improved T1-weighted DANTE-SPACE sequence is a reproducible method for the simultaneous assessment of intra- and extracranial vessel wall using a single MR scan. This method could potentially be used for assessing responses to therapy and for monitoring disease progression.
journal_name
Magn Reson Imagingjournal_title
Magnetic resonance imagingauthors
Wan L,Zhang N,Zhang L,Long X,Jia S,Li Y,Liang D,Zheng H,Liu Xdoi
10.1016/j.mri.2019.04.016subject
Has Abstractpub_date
2019-10-01 00:00:00pages
152-158eissn
0730-725Xissn
1873-5894pii
S0730-725X(19)30061-Xjournal_volume
62pub_type
杂志文章abstract::Perceptions of sensation and pain in healthy people are believed to be the net result of sensory input and descending modulation from brainstem and cortical regions depending on emotional and cognitive factors. Here, the influence of attention on neural activity in the spinal cord during thermal sensory stimulation of...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2010.07.012
更新日期:2011-01-01 00:00:00
abstract::The applicability of the synthetic manganese porphyrin MnTPPS as tumor-selective MRI-contrast agent for brain tumors was investigated quantitatively by in vivo relaxometry. To exclude toxic effects of side products, the purification method for MnTPPS was improved. As a result, MnTPPS+Cl- (free acid) with a purity of m...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(93)90007-z
更新日期:1993-01-01 00:00:00
abstract::Acetaminophen (APAP) toxicity is responsible for approximately half of all cases of acute liver failure in the United States. The mouse model of APAP toxicity is widely used to examine mechanisms of APAP toxicity. Noninvasive approaches would allow for serial measurements in a single animal to study the effects of exp...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2011.09.023
更新日期:2012-02-01 00:00:00
abstract::The misunderstanding of the labeling for an "MR conditional" respiratory ventilator system resulted in the placement of this device, which had substantial ferromagnetic components, too close to a 3-T magnetic resonance (MR) system, causing a projectile incident. Magnetic resonance imaging health care professionals sho...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2011.07.002
更新日期:2011-10-01 00:00:00
abstract::The value of NMR spectrometry as a way to understand the porosity and permeability of rocks is well documented. Other more esoteric parameters, such as restrictive diffusion, grain size distribution, and fluid viscosities have received less notice but are also available from the NMR measurements as laboratory studies ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)91537-7
更新日期:1994-01-01 00:00:00
abstract::Functional magnetic resonance imaging (fMRI) based on the so-called blood oxygen level-dependent (BOLD) contrast is a powerful tool for studying brain function not only locally but also on the large scale. Most studies assume a simple relationship between neural and BOLD activity, in spite of the fact that it is impor...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2009.12.016
更新日期:2010-10-01 00:00:00
abstract::Functional magnetic resonance imaging (FMRI) is a major tool for the evaluation of brain function and architecture. It is widely used by physicians, neuroscientists, psychologists and others. In order to process the data collected using FMRI, it is necessary to use post-acquisition processing software that employs mot...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2005.04.007
更新日期:2005-06-01 00:00:00
abstract::With the recent development of integrated positron emission tomography-magnetic resonance imaging (PET-MRI) scanners, new possibilities for quantitative molecular imaging of cancer are realized. However, the practical advantages and potential clinical benefits of the ability to record PET and MRI data simultaneously m...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章,评审
doi:10.1016/j.mri.2012.06.001
更新日期:2012-11-01 00:00:00
abstract:BACKGROUND AND PURPOSE:Slice-encoding metal artifact corrections (SEMAC)-view-angle tilting (VAT) sequences have recently been used in clinical protocols to reduce metal artifacts in MR scans of patients with spinal instrumentation. The objective of this study was to compare the SEMAC-VAT sequence with the conventional...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2018.08.002
更新日期:2018-12-01 00:00:00
abstract::Gadolinium DTPA was evaluated as an intravenous contrast agent for magnetic resonance imaging in 15 patients with primary or secondary intracranial neoplastic disease. T1 and T2 weighted images were obtained prior to contrast administration. T1 weighted spin echo 35/800 (TE/TR) images were utilized to detect enhanceme...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(85)90006-2
更新日期:1985-01-01 00:00:00
abstract::In congenital diaphragmatic hernia (CDH), lung hypoplasia and secondary pulmonary hypertension are the major causes of death and severe disability. Based on new therapeutic strategies survival rates could be improved to up to 80%. However, after surgical repair of CDH, long-term follow-up of these pediatric patients i...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2015.08.003
更新日期:2015-12-01 00:00:00
abstract::We have extended the utility of NMR as a technique to probe porous media structure over length scales of approximately 100-2000 microm by using the spin 1/2 noble gas 129Xe imbibed into the system's pore space. Such length scales are much greater than can be probed with NMR diffusion studies of water-saturated porous ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(01)00247-8
更新日期:2001-04-01 00:00:00
abstract::Autofocusing is a postprocessing technique for motion correction, which optimizes an image quality metric against various trial motions. In this work, image metric maps, which are measures of image quality plotted as a function of in-plane 2-D trial translations, are systematically studied to develop improved autofocu...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2006.02.003
更新日期:2006-07-01 00:00:00
abstract:PURPOSE:Rapid regional fluctuations in GABA may result in inhomogeneous concentrations throughout the brain parenchyma. The goal of this study is to provide further insight into the natural distribution of GABA throughout the brain and thus determine if a surrogate site may be used for spectroscopy when evaluating moto...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2015.02.015
更新日期:2015-06-01 00:00:00
abstract::In pharmacological magnetic resonance imaging (phMRI) with anesthetized animals, there is usually only a single time window to observe the dynamic signal change to an acute drug administration since subsequent drug injections are likely to result in altered response properties (e.g., tolerance). Unlike the block-desig...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2008.02.020
更新日期:2008-11-01 00:00:00
abstract:PURPOSE:To identify quantitative dynamic contrast-enhanced (DCE)-MRI perfusion parameters indicating tumor response of hepatocellular carcinoma (HCC) to transarterial chemoembolization (TACE). MATERIALS AND METHODS:This prospective pilot study was approved by our institutional review board; written and informed consen...
journal_title:Magnetic resonance imaging
pub_type: 临床试验,杂志文章
doi:10.1016/j.mri.2019.06.017
更新日期:2019-10-01 00:00:00
abstract::Liver fibrosis determines the functional liver reserve. Several studies have reported that the apparent diffusion coefficient (ADC) values of diffusion-weighted magnetic resonance imaging (DW-MRI) can assess liver fibrosis. We investigated whether DW-MRI predicts postoperative hepatic insufficiency and liver fibrosis ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2010.03.018
更新日期:2010-07-01 00:00:00
abstract::Radio frequency magnetic fields from 5 to 100 kHz off resonance reduce longitudinal magnetization of water in some tissues without affecting the magnetization of simple solutions (Wolff, S.D.; Balaban, R.S. Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo. Magn. Reson. Med. 10:135-144; ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(90)90050-c
更新日期:1990-01-01 00:00:00
abstract:PURPOSE:While PRESS is often employed to measure glutamate concentrations, MEGA-PRESS enables simultaneous Glx (glutamate and glutamine) and GABA measurements. This study aimed to compare validation, repeatability, and concordance of different approaches for glutamate quantification at 3T to aid future studies in their...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2017.12.029
更新日期:2018-05-01 00:00:00
abstract::Peripheral magnetic resonance angiography (MRA) is growing in use. However, methods of performing peripheral MRA vary widely and continue to be optimized, especially for improvement in illustration of infrapopliteal arteries. The main purpose of this project was to identify imaging factors that can improve arterial vi...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(02)00531-3
更新日期:2002-09-01 00:00:00
abstract::High-resolution magnetic resonance imaging using dedicated high-field radiofrequency micro-coils at 16.4 T (700 MHz) was investigated. Specific solenoid coils primarily using silver and copper as conductors with enamel and polyurethane coatings were built to establish which coil configuration produces the best image. ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2012.04.027
更新日期:2012-10-01 00:00:00
abstract::Functional magnetic resonance imaging (fMRI) has found widespread clinical interest. Difficulties in clinical use of the fMRI technique arise, considering the lack of knowledge about activation task performance. This accounts especially for sensorimotor activation studies, in which performance of the sensorimotor acti...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(95)02052-u
更新日期:1996-01-01 00:00:00
abstract::The penetration of horse liver alcohol dehydrogenase (HLAD) molecules into polyacrylamide gel beads, which are used to immobilize the enzyme, was studied. HLAD was labeled with gadolinium diethylene-triamine-pentaacetic acid (Gd-DTPA), using the N-hydroxy-succinimide active ester of DTPA as a chelating agent. The HLAD...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(91)90046-o
更新日期:1991-01-01 00:00:00
abstract:PURPOSE:To develop a method for estimating metabolite concentrations using phased-array coils and sensitivity-encoded (SENSE) magnetic resonance spectroscopic images (MRSI) of the human brain. MATERIALS AND METHODS:The method is based on the phantom replacement technique and uses receive coil sensitivity maps and body...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2009.11.003
更新日期:2010-04-01 00:00:00
abstract::A fast spin echo two-point Dixon (fast 2PD) technique was developed for efficient T2-weighted imaging with uniform water and fat separation. The technique acquires two interleaved fast spin echo images with water and fat in-phase and 180 degrees out-of-phase, respectively, and generates automatically separate water an...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2005.10.005
更新日期:2005-12-01 00:00:00
abstract::With the aim of developing a fast algorithm for high-quality MRI reconstruction from undersampled k-space data, we propose a novel deep neural Network, which is inspired by Iterative Shrinkage Thresholding Algorithm with Data consistency (NISTAD). NISTAD consists of three consecutive blocks: an encoding block, which m...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2020.04.016
更新日期:2020-07-01 00:00:00
abstract::The biodistribution and relative molar effectiveness of the ionic (GdCl3) and chelated (Gd-DTPA) forms of gadolinium (Gd) to enhance proton relaxation rates in rat kidney, liver and spleen were evaluated. Rats were given intravenous injections of either GdCl3 (100 mumol/kg) or Gd-DTPA (178 mumol/kg). Gd-DTPA was prima...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(87)90023-3
更新日期:1987-01-01 00:00:00
abstract::Primary epiploic appendagitis (PEA) occurs secondary to inflammation of an epiploic appendage, and is considered to be a rare cause of acute abdomen. In this case report, we describe the magnetic resonance imaging (MRI) findings of PEA correlated with computed tomographic (CT) findings. MRI findings included an oval s...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(02)00478-2
更新日期:2002-01-01 00:00:00
abstract::Retained sponges after laparotomy may cause a broad spectrum of clinical symptoms and present a difficult diagnostic problem. We report a case of retained surgical sponge in a dog to illustrate the MRI findings of this infrequent but important cause of postoperative complications. ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(85)90358-3
更新日期:1985-01-01 00:00:00
abstract::Relaxation time measurements were carried out during the preacute stage of lesion progression in an animal model of demyelination created in the internal capsule (ic) area of the rat brain using lysophosphatidyl choline (LPC). T1 and T2 were determined both before and after 36 h of lesion creation. Histology carried o...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2004.11.010
更新日期:2005-01-01 00:00:00