The comparison of the performance of 3 T and 7 T T2 mapping for untreated low-grade cartilage lesions.

Abstract:

OBJECTIVE:To investigate T2 mapping as a possible marker for low-grade human articular cartilage lesions during a one-year follow-up, possible changes during the follow-up and compare the reliability and sensitivity of these measurements on high-field (3 T) and ultra-high-field (7 T) MRI scanners. DESIGN:Twenty-one patients with femoral, tibial and patellar cartilage defect in the knee joint participated in the study. The MRI protocol consisted of morphological, as well as three-dimensional triple-echo steady-state (3D-TESS) T2 mapping sequences with similar parameters at 3T and 7T. Patients were scanned at five time-points up to 12 months. T2 values were evaluated in the lesion and healthy-appearing regions for superficial and deep cartilage zone. The repeated ANOVA was used to determine differences in T2 values at various time points. RESULTS:A significant decrease in T2 values was observed between baseline and six months in the superficial layer of the lesion in patients at 3 T (decrease from 41.89 ± 9.3 ms to 31.21 ± 7.2 ms, which is a difference of -5.67 ± 2.2 ms (p = 0.031)), and at 12 months in the superficial layer of the lesion in patients at 3 T (decrease from 41.89 ± 9.3 ms to 35.28 ± 4.9 ms, which is a difference of -6.60 ± 4.4 ms (p = 0.044). No significant differences were recorded at 7 T. CONCLUSION:The change in T2 values acquired with 3 T 3D-TESS appears to be reflecting subtle changes of cartilage composition in the course of low-grade lesion development. 7 T T2 mapping does not reflect these changes probably due to completely decayed short T2 component.

journal_name

Magn Reson Imaging

authors

Juras V,Schreiner M,Laurent D,Zbýň Š,Mlynarik V,Szomolanyi P,Hager B,Scotti C,Goldhahn J,Heule R,Bieri O,Trattnig S

doi

10.1016/j.mri.2018.09.021

subject

Has Abstract

pub_date

2019-01-01 00:00:00

pages

86-92

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(18)30362-X

journal_volume

55

pub_type

杂志文章
  • Carotid plaque high-resolution MRI at 3 T: evaluation of a new imaging score for symptomatic plaque assessment.

    abstract:PURPOSE:To assess the sensitivity and specificity of intra-plaque hemorrhage (IPH), large lipid-rich necrotic core (LR-NC) and ulceration or cap rupture (UCR) for symptomatic carotid plaque characterization and to evaluate a new imaging score [Hemorrhage, Ulceration or cap rupture, Lipid-rich necrotic Core (HULC) score...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.04.024

    authors: Gury-Paquet L,Millon A,Salami F,Cernicanu A,Scoazec JY,Douek P,Boussel L

    更新日期:2012-12-01 00:00:00

  • Considerations in applying 3D PRESS H-1 brain MRSI with an eight-channel phased-array coil at 3 T.

    abstract::The purpose of this study was to assess the benefits of a 3 T scanner and an eight-channel phased-array head coil for acquiring three-dimensional PRESS (Point REsolved Spectral Selection) proton (H-1) magnetic resonance spectroscopic imaging (MRSI) data from the brains of volunteers and patients with brain tumors rela...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.07.012

    authors: Li Y,Osorio JA,Ozturk-Isik E,Chen AP,Xu D,Crane JC,Cha S,Chang S,Berger MS,Vigneron DB,Nelson SJ

    更新日期:2006-12-01 00:00:00

  • Influence of baseline hematocrit on between-subject BOLD signal change using gradient echo and asymmetric spin echo EPI.

    abstract::The dependence of BOLD signal change (BSC) on baseline hematocrit is in the process of being characterized, primarily using conventional Gradient Echo (GE) echo planar imaging (EPI). We describe the first empiric exploration of this relationship using, in addition to GE, Spin Echo (SE) and two Asymmetric Spin Echo EPI...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00083-3

    authors: Gustard S,Williams EJ,Hall LD,Pickard JD,Carpenter TA

    更新日期:2003-07-01 00:00:00

  • Highly homogeneous circularly polarized RF field for whole body NMR imaging.

    abstract::Conditions for generation of polarized RF fields in cylindrical symmetry by high order coils are presented. Whole body NMR transmitters utilizing this principle would require a current control on a certain number of loops. In the present design this is obtained by feeding each loop by an appropriate linear combination...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90398-0

    authors: Sotgiu A,Gualtieri G,Passariello R

    更新日期:1988-05-01 00:00:00

  • Pure uterine lipoma.

    abstract::Lipomatous tumors of the uterus are unusual, benign neoplasms seen in postmenopausal women. Although many of the mixed-type cases such as lipoleiomyoma and fibrolipoma have been reported, pure uterine lipomas are extremely rare. In the literature, a few cases with pure uterine lipoma have been reported. We first prese...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.01.116

    authors: Erdem G,Celik O,Karakas HM,Alkan A,Hascalik S

    更新日期:2007-10-01 00:00:00

  • MRI-assisted radiation therapy planning of brain tumors--clinical experiences in 17 patients.

    abstract::A new and simple method for precise determination of lateral opposed treatment portals was developed and used in 17 patients. Compared to CT, MRI led to significant changes of portals in 59% (10/17) of cases. Individual shielding blocks could be precisely designed by use of our new method. MRI is the procedure of choi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90007-9

    authors: Just M,Rösler HP,Higer HP,Kutzner J,Thelen M

    更新日期:1991-01-01 00:00:00

  • Effect of slice orientation on reproducibility of fMRI motor activation at 3 Tesla.

    abstract::The effect of slice orientation on reproducibility and sensitivity of 3T fMRI activation using a motor task has been investigated in six normal volunteers. Four slice orientations were used; axial, oblique axial, coronal and sagittal. We applied analysis of variance (ANOVA) to suprathreshold voxel statistics to quanti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00399-x

    authors: Gustard S,Fadili J,Williams EJ,Hall LD,Carpenter TA,Brett M,Bullmore ET

    更新日期:2001-12-01 00:00:00

  • The effects of changing water content, relaxation times, and tissue contrast on tissue segmentation and measures of cortical anatomy in MR images.

    abstract::Water content is the dominant chemical compound in the brain and it is the primary determinant of tissue contrast in magnetic resonance (MR) images. Water content varies greatly between individuals, and it changes dramatically over time from birth through senescence of the human life span. We hypothesize that the effe...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.07.017

    authors: Bansal R,Hao X,Liu F,Xu D,Liu J,Peterson BS

    更新日期:2013-12-01 00:00:00

  • Multispectral analysis of bone lesions in the hands of patients with rheumatoid arthritis.

    abstract::Quantitative measures of rheumatoid arthritis (RA) disease progression can provide valuable tools for evaluation of new treatments during clinical trials. In this study, a novel multispectral (MS) MRI analysis method is presented to quantify changes in bone lesion volume (DeltaBLV) in the hands of RA patients. Image r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.013

    authors: Carano RA,Lynch JA,Redei J,Ostrowitzki S,Miaux Y,Zaim S,White DL,Peterfy CG,Genant HK

    更新日期:2004-05-01 00:00:00

  • Simple phase method for measurement of magnetic field gradient waveforms.

    abstract::Magnetic field gradients play a fundamental role in MR imaging and localized spectroscopy. The MRI experiment, in particular fast MRI, relies on precise gradient switching, which has become more demanding with the constantly growing number of fast imaging techniques. Here we present a simple MR method to measure the b...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.02.002

    authors: Latta P,Gruwel ML,Volotovskyy V,Weber MH,Tomanek B

    更新日期:2007-11-01 00:00:00

  • Detection of mycotic pseudoaneurysm of the ascending aorta using MRI.

    abstract::Mycotic pseudoaneurysms of the ascending aorta are rare cardiovascular lesions that carry the risk of potentially disastrous complications such as aortic rupture or widespread sepsis. Regardless of its location in the arterial system, this lesion carries a high mortality rate. Early diagnosis of mycotic pseudoaneurysm...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90251-8

    authors: McCuskey WH,Loehr SP,Smidebush GC,Link KM

    更新日期:1993-01-01 00:00:00

  • Wavelet-based characterization of vertebral trabecular bone structure from magnetic resonance images at 3 T compared with micro-computed tomographic measurements.

    abstract::Trabecular bone structure and bone density contribute to the strength of bone and are important in the study of osteoporosis. Wavelets are a powerful tool in characterizing and quantifying texture in an image. The purpose of this study was to validate wavelets as a tool in computing trabecular bone thickness directly ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.09.020

    authors: Krug R,Carballido-Gamio J,Burghardt AJ,Haase S,Sedat JW,Moss WC,Majumdar S

    更新日期:2007-04-01 00:00:00

  • Structural changes in glutamate cell swelling followed by multiparametric q-space diffusion MR of excised rat spinal cord.

    abstract::Diffusion in the extracellular and intracellular spaces (ECS and ICS, respectively) was evaluated in excised spinal cords, before and after cell swelling induced by glutamate, by high b-value q-space diffusion MR of specific markers and water. The signal decays of deuterated tetramethylammonium (TMA-d(12)) chloride, a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.029

    authors: Biton IE,Mayk A,Assaf Y,Cohen Y

    更新日期:2004-06-01 00:00:00

  • Agarose as a tissue equivalent phantom material for NMR imaging.

    abstract::Phantoms for evaluation of nuclear magnetic resonance (NMR) imaging systems were made from water-based agarose gels, according to a standard procedure herein described. Copper sulfate (CuSO4) was included in the gels to further affect their proton relaxation characteristics. The proton relaxation rates of each batch o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(86)91068-4

    authors: Mitchell MD,Kundel HL,Axel L,Joseph PM

    更新日期:1986-01-01 00:00:00

  • Chemical exchange saturation transfer MR imaging of articular cartilage glycosaminoglycans at 3 T: Accuracy of B0 Field Inhomogeneity corrections with gradient echo method.

    abstract::Glycosaminoglycan Chemical Exchange Saturation Transfer (gagCEST) is an important molecular MRI methodology developed to assess changes in cartilage GAG concentrations. The correction for B0 field inhomogeneity is technically crucial in gagCEST imaging. This study evaluates the accuracy of the B0 estimation determined...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.07.009

    authors: Wei W,Jia G,Flanigan D,Zhou J,Knopp MV

    更新日期:2014-01-01 00:00:00

  • Self-navigated 3D whole-heart MRA for non-enhanced surveillance of thoracic aortic dilation: A comparison to CTA.

    abstract:PURPOSE:To prospectively compare image quality and reliability of a non-contrast, self-navigated 3D whole-heart magnetic resonance angiography (MRA) sequence with contrast-enhanced computed tomography angiography (CTA) for sizing of thoracic aortic aneurysm (TAA). METHODS:Self-navigated 3D whole-heart 1.5 T MRA was pe...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.12.003

    authors: Poskaite P,Pamminger M,Kranewitter C,Kremser C,Reindl M,Reiter G,Piccini D,Dumfarth J,Henninger B,Tiller C,Holzknecht M,Reinstadler SJ,Klug G,Metzler B,Mayr A

    更新日期:2021-02-01 00:00:00

  • Single-shot-double-echo EPI.

    abstract::Echo planar imaging (EPI) was extended for the acquisition of both, the spin-echo (SE) and the stimulated echo in a stimulated echo sequence after one excitation from thermal equilibrium. The two independent EPI images reflect different states of the transverse magnetization excited and measured almost simultaneously....

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91234-n

    authors: Börnert P,Jensen D

    更新日期:1994-01-01 00:00:00

  • High-resolution MR venography of cerebral arteriovenous malformations.

    abstract::The purpose of this study was to evaluate the diagnostic potential of a high-resolution magnetic resonance (MR) venography technique in patients with cerebral arteriovenous malformations (AVMs). A high-resolution 3D gradient echo sequence was used with a long echo time TE to obtain venous information down to sub-pixel...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00084-3

    authors: Essig M,Reichenbach JR,Schad LR,Schoenberg SO,Debus J,Kaiser WA

    更新日期:1999-12-01 00:00:00

  • Diffusion-weighted imaging in epilepsy.

    abstract::Diffusion-weighted imaging (DWI) is a relatively new magnetic resonance imaging (MRI) technique that can be used to probe the microenvironment of water. Contrast in DWI depends on properties different from traditional T1 and T2 contrast, and is derived form the translational motion of water molecules. Since it is reas...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(95)02036-s

    authors: Helpern JA,Huang N

    更新日期:1995-01-01 00:00:00

  • Signal and contrast effects due to T2 decay during k-space readout of UTE (ultrashort TE) sequences.

    abstract::In ultrashort TE (UTE) imaging, the short T2 values of the tissues of interest are comparable to the k-space readout duration, which result in significant T2 decay during k-space readout. This decay consequently causes significant effects on signal and contrast in UTE sequences, which we evaluate in this paper using m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.11.002

    authors: Chiang JT,Carl M,Du J

    更新日期:2014-04-01 00:00:00

  • Investigations of polymer dynamics in nanoporous media by field cycling NMR relaxometry and the dipolar correlation effect.

    abstract::The chain dynamics of short-chain perfluoropolyether melts confined in Vycor nanoporous media has been characterized by field cycling nuclear magnetic resonance relaxometry and the dipolar correlation effect. The slowdown of motions under confinement, leading to larger residual dipolar couplings, has been probed by lo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.11.018

    authors: Kausik R,Fatkullin N,Hüsing N,Kimmich R

    更新日期:2007-05-01 00:00:00

  • Gadolinium-enhanced magnetic resonance angiography of renal transplants.

    abstract::Our purpose was to investigate three-dimensional (3D) gadolinium-enhanced magnetic resonance angiography (Gd-MRA) in the evaluation of renal transplant arteries. Eleven MR angiography examinations were performed in nine renal transplant patients. Gd-MRA, three-dimensional phase contrast (3D-PC) post-gadolinium, and tw...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00348-7

    authors: Johnson DB,Lerner CA,Prince MR,Kazanjian SN,Narasimham DL,Leichtman AB,Cho KJ

    更新日期:1997-01-01 00:00:00

  • Explicit treatment of mutual inductance in eight-column birdcage resonators.

    abstract::A formulation has been developed for the determination of self and mutual inductances in unloaded, eight-column symmetric birdcage coils using their expected resonant mode current patterns and well-known inductance formulas. The average frequency differences between theory and experiment for mode one resonances for ni...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90511-w

    authors: Pascone R,Vullo T,Farrelly J,Cahill PT

    更新日期:1992-01-01 00:00:00

  • Impact of baseline CO2 on Blood-Oxygenation-Level-Dependent MRI measurements of cerebrovascular reactivity and task-evoked signal activation.

    abstract::Neurovascular coupling describes the cascade between neuronal activity and subsequent Blood-Oxygenation-Level-Dependent (BOLD) signal increase. Based on this premise, the correlation of this BOLD signal increase with a particular task, such as finger-tapping, is used to map neuronal activation. This signal increase ma...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.02.002

    authors: van Niftrik CHB,Piccirelli M,Bozinov O,Maldaner N,Strittmatter C,Pangalu A,Valavanis A,Regli L,Fierstra J

    更新日期:2018-06-01 00:00:00

  • Comparison of different methods for combining phase-contrast images obtained with multiple coils.

    abstract::The ability to determine coil sensitivities implies that a method optimized in terms of maximized signal-to-noise ratio (SNR) can be applied to the combination of multiple coil images. An optimization of SNR subsequently results in a minimized variance in quantitative velocity measurements using phase-contrast imaging...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.06.002

    authors: Thunberg P,Karlsson M,Wigström L

    更新日期:2005-09-01 00:00:00

  • Diffusion-weighted MRI and MR- volumetry--in the evaluation of tumor response after preoperative chemoradiotherapy in patients with locally advanced rectal cancer.

    abstract:PURPOSE:To determine the diagnostic performance of diffusion-weighted MRI and MR volumetry for the assessment of tumor response after preoperative chemoradiotherapy (CRT) in patients with locally advanced rectal cancer. MATERIALS AND METHODS:Forty-three patients with rectal cancer who underwent preoperative CRT were p...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.08.041

    authors: Birlik B,Obuz F,Elibol FD,Celik AO,Sokmen S,Terzi C,Sagol O,Sarioglu S,Gorken I,Oztop I

    更新日期:2015-02-01 00:00:00

  • Parallel imaging for first-pass myocardial perfusion.

    abstract::Two parallel imaging methods used for first-pass myocardial perfusion imaging were compared in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and image artifacts. One used adaptive Time-adaptive SENSitivity Encoding (TSENSE) and the other used GeneRalized Autocalibrating Partially Parallel Acquisi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.10.012

    authors: Irwan R,Lubbers DD,van der Vleuten PA,Kappert P,Götte MJ,Sijens PE

    更新日期:2007-06-01 00:00:00

  • Improved optimization strategies for autofocusing motion compensation in MRI via the analysis of image metric maps.

    abstract::Autofocusing is a postprocessing technique for motion correction, which optimizes an image quality metric against various trial motions. In this work, image metric maps, which are measures of image quality plotted as a function of in-plane 2-D trial translations, are systematically studied to develop improved autofocu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.02.003

    authors: Lin W,Song HK

    更新日期:2006-07-01 00:00:00

  • Analysis of machine-dependent and object-induced geometric distortion in 2DFT MR imaging.

    abstract::Geometric distortion in MR imaging predominantly arises from the inhomogeneity of the static field and the nonlinearity of the gradients. It is the purpose of this paper to analyse the object and machine related contributions to geometric distortion in order to determine which corrections are necessary for attaining a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90011-n

    authors: Bakker CJ,Moerland MA,Bhagwandien R,Beersma R

    更新日期:1992-01-01 00:00:00

  • Noninvasive evaluation of the regional variations of GABA using magnetic resonance spectroscopy at 3 Tesla.

    abstract:PURPOSE:Rapid regional fluctuations in GABA may result in inhomogeneous concentrations throughout the brain parenchyma. The goal of this study is to provide further insight into the natural distribution of GABA throughout the brain and thus determine if a surrogate site may be used for spectroscopy when evaluating moto...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.02.015

    authors: Durst CR,Michael N,Tustison NJ,Patrie JT,Raghavan P,Wintermark M,Sendhil Velan S

    更新日期:2015-06-01 00:00:00