The effects of changing water content, relaxation times, and tissue contrast on tissue segmentation and measures of cortical anatomy in MR images.

Abstract:

:Water content is the dominant chemical compound in the brain and it is the primary determinant of tissue contrast in magnetic resonance (MR) images. Water content varies greatly between individuals, and it changes dramatically over time from birth through senescence of the human life span. We hypothesize that the effects that individual- and age-related variations in water content have on contrast of the brain in MR images also have important, systematic effects on in vivo, MRI-based measures of regional brain volumes. We also hypothesize that changes in water content and tissue contrast across time may account for age-related changes in regional volumes, and that differences in water content or tissue contrast across differing neuropsychiatric diagnoses may account for differences in regional volumes across diagnostic groups. We demonstrate in several complementary ways that subtle variations in water content across age and tissue compartments alter tissue contrast, and that changing tissue contrast in turn alters measures of the thickness and volume of the cortical mantle: (1) We derive analytic relations describing how age-related changes in tissue relaxation times produce age-related changes in tissue gray-scale intensity values and tissue contrast; (2) We vary tissue contrast in computer-generated images to assess its effects on tissue segmentation and volumes of gray matter and white matter; and (3) We use real-world imaging data from adults with either Schizophrenia or Bipolar Disorder and age- and sex-matched healthy adults to assess the ways in which variations in tissue contrast across diagnoses affects group differences in tissue segmentation and associated volumes. We conclude that in vivo MRI-based morphological measures of the brain, including regional volumes and measures of cortical thickness, are a product of, or at least are confounded by, differences in tissue contrast across individuals, ages, and diagnostic groups, and that differences in tissue contrast in turn likely derive from corresponding differences in water content of the brain across individuals, ages, and diagnostic groups.

journal_name

Magn Reson Imaging

authors

Bansal R,Hao X,Liu F,Xu D,Liu J,Peterson BS

doi

10.1016/j.mri.2013.07.017

subject

Has Abstract

pub_date

2013-12-01 00:00:00

pages

1709-30

issue

10

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(13)00262-2

journal_volume

31

pub_type

杂志文章
  • Fast and exact flow measurements with the fast Fourier flow technique.

    abstract::The fast Fourier flow technique offers a convenient way for extremely exact flow measurements. In combination with ECG gating, arterial flow can be studied. The total acquisition time for a single measurement is about 10 s, an ECG-gated cine sequence can be acquired in about 4 min. Fast Fourier flow can, therefore, be...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90473-0

    authors: Hennig J,Mueri M,Brunner P,Friedburg H

    更新日期:1988-07-01 00:00:00

  • Quantification of synovistis by MRI: correlation between dynamic and static gadolinium-enhanced magnetic resonance imaging and microscopic and macroscopic signs of synovial inflammation.

    abstract::Dynamic and static gadolinium-diethylenetriaminepentaacetic acid(Gd-DTPA)-enhanced magnetic resonance imaging (MRI) were evaluated as measures of joint inflammation in arthritis, by a comparison with macroscopic and microscopic signs of synovitis. Furthermore, the importance of the size of the evaluated synovial areas...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00008-3

    authors: Ostergaard M,Stoltenberg M,Løvgreen-Nielsen P,Volck B,Sonne-Holm S,Lorenzen I

    更新日期:1998-09-01 00:00:00

  • Hair product artifact in magnetic resonance imaging.

    abstract::The presence of metallic compounds in facial cosmetics and permanent tattoos may affect the quality of magnetic resonance imaging. We report a case study describing a signal artifact due to the use of a leave-on powdered hair dye. On reviewing the ingredients of the product, it was found to contain several metallic co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.08.023

    authors: Chenji S,Wilman AH,Mah D,Seres P,Genge A,Kalra S

    更新日期:2017-01-01 00:00:00

  • Area of paradoxical signal drop after the administration of superparamagnetic iron oxide on the T2-weighted image of a patient with lymphangitic metastasis of the liver.

    abstract::We report a geographic area of prominent hypointensity in T2-weighted images vs. normal adjacent liver parenchyma in a patient with cholangiocarcinoma and lymphangitic metastasis of the liver after superparamagnetic iron oxide (SPIO) administration. The area showing this prominent signal drop showed Kupffer cell proli...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.10.012

    authors: Lee Y,Lee JS,Kim CM,Jeong JY,Choi JI,Kim MJ

    更新日期:2008-05-01 00:00:00

  • Correlation of MRI findings to histology of acetaminophen toxicity in the mouse.

    abstract::Acetaminophen (APAP) toxicity is responsible for approximately half of all cases of acute liver failure in the United States. The mouse model of APAP toxicity is widely used to examine mechanisms of APAP toxicity. Noninvasive approaches would allow for serial measurements in a single animal to study the effects of exp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.09.023

    authors: Brown AT,Ou X,James LP,Jambhekar K,Pandey T,McCullough S,Chaudhuri S,Borrelli MJ

    更新日期:2012-02-01 00:00:00

  • Simultaneous PET-MRI in oncology: a solution looking for a problem?

    abstract::With the recent development of integrated positron emission tomography-magnetic resonance imaging (PET-MRI) scanners, new possibilities for quantitative molecular imaging of cancer are realized. However, the practical advantages and potential clinical benefits of the ability to record PET and MRI data simultaneously m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2012.06.001

    authors: Yankeelov TE,Peterson TE,Abramson RG,Izquierdo-Garcia D,Arlinghaus LR,Li X,Atuegwu NC,Catana C,Manning HC,Fayad ZA,Gore JC

    更新日期:2012-11-01 00:00:00

  • Superparamagnetic iron oxide particles and positive enhancement for myocardial perfusion studies assessed by subsecond T1-weighted MRI.

    abstract::Superparamagnetic iron oxide particles (SPIOs) are usually referred to as T2 MR contrast agents, reducing signal intensity (SI) on T2-weighted MR images (negative enhancement). This study reports the original use of SPIOs as T1-enhancing contrast agents, primarily assessed in vitro, and then applied to an in vivo inve...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90241-5

    authors: Canet E,Revel D,Forrat R,Baldy-Porcher C,de Lorgeril M,Sebbag L,Vallee JP,Didier D,Amiel M

    更新日期:1993-01-01 00:00:00

  • Fast Field Echo imaging: an overview and contrast calculations.

    abstract::Current fast imaging techniques are based on gradient echo sequences with reduced flip angle excitation pulses and very short repetition times TR. Practical T2 values may be of the order of TR or longer. In this situation, a different image contrast can be obtained, depending on details of the sequence. Four essential...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(88)90472-9

    authors: van der Meulen P,Groen JP,Tinus AM,Bruntink G

    更新日期:1988-07-01 00:00:00

  • In-plane flow velocity quantification along the phase encoding axis in MRI.

    abstract::In-plane flow quantification in MRI offers the potential for assessing vessel patency, and both volume flow rate and flow velocity. These techniques will have definite future impact on MR angiography. The method used in this paper employs motion artifact suppression technique (MAST) gradients to refocus spins travelli...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90409-2

    authors: Duerk JL,Pattany PM

    更新日期:1988-05-01 00:00:00

  • Astrocytic energy metabolism and glutamate formation--relevance for 13C-NMR spectroscopy and importance of cytosolic/mitochondrial trafficking.

    abstract::Glutamate plays a double role in (13)C-nuclear magnetic resonance (NMR) spectroscopic determination of glucose metabolism in the brain. Bidirectional exchange between initially unlabeled glutamate and labeled α-ketoglutarate, formed from pyruvate via pyruvate dehydrogenase (PDH), indicates the rate of energy metabolis...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.04.013

    authors: Hertz L

    更新日期:2011-12-01 00:00:00

  • A rapid method for the measurement and estimation of CO2 diffusivity in liquid hydrocarbon-saturated porous media using MRI.

    abstract::In this study, magnetic resonance imaging (MRI) was used to dynamically visualize the diffusion process of CO2 in porous media saturated with liquid hydrocarbon. Based on the assumption of semi-infinite media, effective CO2 diffusivity was obtained directly by the nonlinear fitting of one MR profile during the diffusi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.12.024

    authors: Zhao Y,Chen J,Yang M,Liu Y,Song Y

    更新日期:2016-05-01 00:00:00

  • Partial angle inversion recovery (PAIR) MR imaging: spin-echo and snapshot implementation.

    abstract::The effects of varying the inversion or excitation RF pulse flip angles on image contrast and imaging time have been investigated in IR imaging theoretically, with phantoms and with normal volunteers. Signal intensity in an IR pulse sequence as a function of excitation, inversion and refocusing pulse flip angles was c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90481-e

    authors: Vinitski S,Albert S,Mitchell DG,Tasciyan TA,Rifkin MD

    更新日期:1992-01-01 00:00:00

  • Intensity dependence of flow signal in slice selective velocity measurements.

    abstract::The quantitative determination of flow velocities using inflow-outflow techniques require slice selective excitation pulses. The intensity-velocity relationship for such methods is shown to be such that flow velocities estimated using techniques which rely on an absolute calibration of the measured intensity are sensi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90325-1

    authors: Saloner D

    更新日期:1989-01-01 00:00:00

  • Three dimensional k-space trajectory design using genetic algorithms.

    abstract::Image quality and total scan time in MRI are determined in large part by the trajectory employed to sample the Fourier space. Each trajectory has different properties like coverage of k-space, scan time, sensitivity to off-resonance conditions, etc. These properties are often contradictory, therefore a universal optim...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00174-7

    authors: Sabat S,Mir R,Guarini M,Guesalaga A,Irarrazaval P

    更新日期:2003-09-01 00:00:00

  • Visualization of Taylor-Couette and spiral Poiseuille flows using a snapshot FLASH spatial tagging sequence.

    abstract::A new magnetic resonance imaging technique was applied to the Taylor-Couette and spiral Poiseuille (Taylor-Couette with superposed mean axial flux) flows for the first time. The experimental technique is a combination of spatial tagging methods and a snapshot FLASH imaging sequence, which allows the full-field visuali...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00121-6

    authors: Moser KW,Raguin LG,Harris A,Morris HD,Georgiadis J,Shannon M,Philpott M

    更新日期:2000-02-01 00:00:00

  • Mitral annular velocity measurement with cardiac magnetic resonance imaging using a novel annular tracking algorithm: Validation against echocardiography.

    abstract:BACKGROUND:Doppler based mitral annular velocities are an integral part of echocardiographic left ventricular diastolic function assessment. Although these measurements can be obtained by phase contrast cardiac magnetic resonance imaging (PC-CMR), this approach has limitations. The aims of this study were to assess the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.08.018

    authors: Thavendiranathan P,Guetter C,da Silveira JS,Lu X,Scandling D,Xue H,Jolly MP,Raman SV,Simonetti OP

    更新日期:2019-01-01 00:00:00

  • Automated classification of multispectral MR images using unsupervised constrained energy minimization based on fuzzy logic.

    abstract::Constrained energy minimization (CEM) has proven highly effective for hyperspectral (or multispectral) target detection and classification. It requires a complete knowledge of the desired target signature in images. This work presents "Unsupervised CEM (UCEM)," a novel approach to automatically target detection and cl...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.03.009

    authors: Lin GC,Wang CM,Wang WJ,Sun SY

    更新日期:2010-06-01 00:00:00

  • A method for MR quantification of flow velocities in blood and CSF using interleaved gradient-echo pulse sequences.

    abstract::The aim of this study was to establish a rapid method for in vivo quantification of a large range of flow velocities using phase information. A basic gradient-echo sequence was constructed, in which flow was encoded along the slice selection direction by variation of the amplitude of a bipolar gradient without changes...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90535-3

    authors: Ståhlberg F,Mogelvang J,Thomsen C,Nordell B,Stubgaard M,Ericsson A,Sperber G,Greitz D,Larsson H,Henriksen O

    更新日期:1989-11-01 00:00:00

  • A data augmentation approach to train fully convolutional networks for left ventricle segmentation.

    abstract::Left ventricle (LV) segmentation plays an important role in the diagnosis of cardiovascular diseases. The cardiac contractile function can be quantified by measuring the segmentation results of LVs. Fully convolutional networks (FCNs) have been proven to be able to segment images. However, a large number of annotated ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.08.004

    authors: Lin A,Wu J,Yang X

    更新日期:2020-02-01 00:00:00

  • Dynamic contrast-enhanced 3D breath hold MRA using a multiple variable orientation slab acquisition.

    abstract::With the conventional 3D MR angiographic sequences, it is difficult to prescribe multiple phases in different orientations, though multiple phases may be prescribed in the same orientation as the initial scan. Magnetic resonance angiography (MRA) was performed in which three slabs were prescribed in different orientat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00003-x

    authors: Shetty AN,Bis KG

    更新日期:1999-07-01 00:00:00

  • High resolution simultaneous imaging of intracranial and extracranial arterial wall with improved cerebrospinal fluid suppression.

    abstract:PURPOSE:To develop a technique for three dimensional (3D) high resolution joint imaging of intracranial and extracranial arterial walls with improved cerebrospinal fluid (CSF) suppression and good blood suppression based on T1 weighted sampling perfection with application optimized contrast using different angle evolut...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.08.004

    authors: Zhang L,Zhang N,Wu J,Liu X,Chung YC

    更新日期:2017-12-01 00:00:00

  • Idiopathic dilatation of the pulmonary artery: report of four cases.

    abstract::Idiopathic dilatation of the pulmonary artery (IDPA) is a rare congenital disease which is usually detected fortuitously on chest x-ray, thus radiologists must be aware of this clinical entity. This report describes four cases to which Magnetic Resonance Imaging (MRI) played a major role in diagnosing IDPA and in dete...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00013-2

    authors: Ugolini P,Mousseaux E,Sadou Y,Sidi D,Mercier LA,Paquet E,Gaux JC

    更新日期:1999-07-01 00:00:00

  • Reproducibility of simultaneous imaging of intracranial and extracranial arterial vessel walls using an improved T1-weighted DANTE-SPACE sequence on a 3 T MR system.

    abstract:PURPOSE:To systematically investigate the scan-rescan, intra-observer, and inter-observer reproducibility of an improved DANTE-SPACE sequence for the simultaneous assessment of intra- and extracranial arterial vessel wall morphology. MATERIALS AND METHODS:Thirty-five healthy volunteers and 10 patients with atheroscler...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.04.016

    authors: Wan L,Zhang N,Zhang L,Long X,Jia S,Li Y,Liang D,Zheng H,Liu X

    更新日期:2019-10-01 00:00:00

  • Sampling time effects on signal-to-noise and contrast-to-noise ratios in spin-echo MRI.

    abstract::This work discusses the effect of sampling time on noise, signal-to-noise and contrast-to-noise ratios in magnetic resonance imaging. A simple imaging experiment is performed to demonstrate the effect of sampling time on noise, confirming theoretical expectations that doubling the sampling time while decreasing the re...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90481-4

    authors: Hendrick RE

    更新日期:1987-01-01 00:00:00

  • Severe anaphylactoid reaction after i.v. Gd-DTPA.

    abstract::Serious adverse reactions following the IV administration of Gd-DTPA (Magnevist, gadopenetate dimeglumine, Berlex Laboratories, Wayne, NJ), although extremely rare, can occur. As yet, there has been no published case of a severe anaphylactoid-type reaction to Gd-DTPA. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90019-x

    authors: Weiss KL

    更新日期:1990-01-01 00:00:00

  • High density barium sulphate as an MRI oral contrast.

    abstract::High density barium sulphate suspension was investigated as an oral contrast on MRI. On 30 consecutive subjects, the stomach (in all cases) and the two first portions of the duodenum (in 21 cases) were filled with the suspension. This oral contrast behaved as a negative contrast, being hypointense on all pulse sequenc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90019-i

    authors: Marti-Bonmati L,Vilar J,Paniagua JC,Talens A

    更新日期:1991-01-01 00:00:00

  • In vivo muscle magnetic resonance spectroscopy in a family with mitochondrial cytopathy: a defect in fat metabolism.

    abstract::In vivo proton and phosphorus magnetic resonance spectroscopy (MRS) studies were performed at 1.5 T on two patients (siblings) diagnosed as having a mitochondrial cytopathy. The clinical diagnosis was based on a complete battery of biochemical tests, electron microscopy and modified Gomori trichrome stain studies of m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90695-4

    authors: Narayana PA,Slopis JM,Jackson EF,Hazle JD,Kulkarni MV,Butler IJ

    更新日期:1989-03-01 00:00:00

  • Functional MR imaging in the awake monkey: effects of motion on dynamic off-resonance and processing strategies.

    abstract::Functional MR imaging of the alert, behaving monkey is being used more and more often to detect activation patterns and guide electrophysiological research investigating the neural basis of behavior. Several labs have reported fMRI data from the awake monkey, but none of them has studied and systematically corrected t...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.03.002

    authors: Pfeuffer J,Shmuel A,Keliris GA,Steudel T,Merkle H,Logothetis NK

    更新日期:2007-07-01 00:00:00

  • Quantitative assessment of rat kidney function by measuring the clearance of the contrast agent Gd(DOTA) using dynamic MRI.

    abstract::Magnetic resonance imaging (MRI) has been applied to assess kidney function in normal rats by monitoring the passage of the extracellular contrast agent GdDOTA. High-resolution images have been obtained using either the rapid acquisition with relaxation enhancement (RARE) or the snapshot pulse sequence. The latter was...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00134-x

    authors: Baumann D,Rudin M

    更新日期:2000-06-01 00:00:00

  • Neural activity-induced modulation of BOLD poststimulus undershoot independent of the positive signal.

    abstract::Despite intense research on the blood oxygenation level-dependent (BOLD) signal underlying functional magnetic resonance imaging, our understanding of its physiological basis is far from complete. In this study, it was investigated whether the so-called poststimulus BOLD signal undershoot is solely a passive vascular ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.04.003

    authors: Sadaghiani S,Uğurbil K,Uludağ K

    更新日期:2009-10-01 00:00:00