Abstract:
:In ultrashort TE (UTE) imaging, the short T2 values of the tissues of interest are comparable to the k-space readout duration, which result in significant T2 decay during k-space readout. This decay consequently causes significant effects on signal and contrast in UTE sequences, which we evaluate in this paper using models that incorporate the gradient slew rate slew and maximal constant gradient strength gmax, in conjunction with objects of diameter L. The resulting signal and contrast relationships demonstrate steep signal changes between T2 values of ~50-500μs, corresponding to high T2 weighted contrast in this range. When γ⋅gmax(2)/(4π⋅slew)>1/(2L), termed the "ramp only" regime, gmax has no significant effect whereas decreasing slew leads to decreases in signal amplitude and shifts the contrast peak to higher T2 values. When γ⋅gmax(2)/(4π⋅slew)<1/(2L), termed the "mixed gradient" regime, both gmax and slew have significant effects, where decreases in either gmax or slew lead to lower signal amplitudes and shifts the contrast peak to higher T2 values. Under typical scan settings, the "ramp only" regime is usually dominant. Further, we demonstrate an unusual dependence of T2 weighted signal and contrast on object size, whereby objects with smaller values of L demonstrate lower signal amplitudes and peak contrast at higher T2 values, compared to otherwise identical objects with larger L. These results improve understanding of T2 weighted signal and contrast properties in short T2 tissue imaging with UTE.
journal_name
Magn Reson Imagingjournal_title
Magnetic resonance imagingauthors
Chiang JT,Carl M,Du Jdoi
10.1016/j.mri.2013.11.002subject
Has Abstractpub_date
2014-04-01 00:00:00pages
259-69issue
3eissn
0730-725Xissn
1873-5894pii
S0730-725X(13)00379-2journal_volume
32pub_type
杂志文章abstract:INTRODUCTION:Glioma is the most common type of the primary CNS tumor. Radiotherapy is an important treatment measure after surgery. However, its highly invasive character is the main reason of postoperative recurrence. The aim of the study was to probe the correlation between the invasion ability and the metabolite cha...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.05.009
更新日期:2016-10-01 00:00:00
abstract::The amplitudes of gradient-echoes produced using static field gradients are sensitive to diffusion of tissue water during the echo evolution time. Gradient-echoes have been used to produce MR images in which image intensity is proportional to the self-diffusion coefficient of water. However, such measurements are subj...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(95)00051-h
更新日期:1995-01-01 00:00:00
abstract::Constrained energy minimization (CEM) has proven highly effective for hyperspectral (or multispectral) target detection and classification. It requires a complete knowledge of the desired target signature in images. This work presents "Unsupervised CEM (UCEM)," a novel approach to automatically target detection and cl...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2010.03.009
更新日期:2010-06-01 00:00:00
abstract::Balanced steady-state free precession (SSFP) sequences use fully re-focussed gradient waveforms to achieve a high signal and useful image contrast in short scan times. Despite these strengths, the clinical feasibility of balanced SSFP is still limited both by bright fat signal and by the signal voids that result from ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2005.10.013
更新日期:2006-02-01 00:00:00
abstract::Many informatics tools have emerged to process the voluminous and complex data generated by functional magnetic resonance imaging (fMRI). The interpretation of fMRI exams is largely determined by these tools. However, their performance is hard to evaluate because there is no independent means of calibration. A novel f...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2005.12.012
更新日期:2006-04-01 00:00:00
abstract::Quantifying the intracranial tissue volume changes in magnetic resonance imaging (MRI) assists specialists to analyze the effects of natural or pathological changes. Since these changes can be subtle, the accuracy of the automatic compartmentalization method is always criticized by specialists. We propose and then eva...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.11.002
更新日期:2020-01-01 00:00:00
abstract::The ability to evaluate empirical diffusion MRI acquisitions for quality and to correct the resulting imaging metrics allows for improved inference and increased replicability. Previous work has shown promise for estimation of bias and variance of generalized fractional anisotropy (GFA) but comes at the price of compu...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.03.021
更新日期:2019-06-01 00:00:00
abstract::Brain alcohol was measured in rhesus monkeys (Macaca mulatta) by proton magnetic resonance spectroscopy (MRS) following acute nasogastric alcohol administration (0.8 g/kg). Monkeys were anesthetized with ketamine and xylazine. A 1.5 T whole body imager and a 3-inch surface coil were used to acquire TE 30 and 270 ms sp...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)90089-a
更新日期:1994-01-01 00:00:00
abstract::Functional magnetic resonance imaging favors the use of multi-slice gradient-recalled echo-planar imaging due to its short image acquisition times, whole brain coverage and sensitivity to BOLD contrast. However, despite its advantages, gradient-recalled echo-planar imaging also is sensitive to static magnetic field gr...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(00)00199-5
更新日期:2000-11-01 00:00:00
abstract:OBJECTIVE:The pathological changes in Parkinson disease begin in the brainstem; reach the limbic system and ultimately spread to the cerebral cortex. In Parkinson disease (PD) patients, we evaluated the alteration of cingulate fibers, which comprise part of the limbic system, by using diffusional kurtosis imaging (DKI)...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2013.06.009
更新日期:2013-11-01 00:00:00
abstract::White matter loss, ventricular enlargement and white matter lesions are common findings on brain scans of older subjects. Accurate assessment of these different features is therefore essential for normal aging research. Recently, we developed a novel unsupervised classification method, named 'Multispectral Coloring Mo...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2011.09.016
更新日期:2012-02-01 00:00:00
abstract::In this contribution, we explore the potential of proton electron double resonance imaging (PEDRI) in environmental science (hydrogeological) applications. After a discussion of the hydrogeological motivation for studies of free radical transport in environmental matrices, we present results from first experiments tha...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2004.11.027
更新日期:2005-02-01 00:00:00
abstract::The aim of this study was to establish a rapid method for in vivo quantification of a large range of flow velocities using phase information. A basic gradient-echo sequence was constructed, in which flow was encoded along the slice selection direction by variation of the amplitude of a bipolar gradient without changes...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(89)90535-3
更新日期:1989-11-01 00:00:00
abstract::The purpose of this study is to report the significant differences found in the identification of lesions in cervical spinal cord of two patients with multiple sclerosis when using the BLADE T2-TSE and BLADE T2-TIRM sequences as opposed to the conventional T2-TSE and T2-TIRM sequences for sagittal acquisition at 1.5T....
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2013.07.008
更新日期:2013-12-01 00:00:00
abstract::Zero-mean noise introduced into quadrature detected MRI signals is generally rectified by the reconstruction algorithm to give a nonzero background intensity in the displayed image. In low signal-to-noise ratio (SNR) images, this background will inflate region of interest (ROI) signal measurements, leading to improper...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(93)90225-3
更新日期:1993-01-01 00:00:00
abstract::Postero-anterior radiographs and magnetic resonance imaging (MRI) of the chest were performed in nine biopsy proven cases of sarcoidosis. MRI was more sensitive than a postero-anterior chest roentgenogram in detecting hilar and mediastinal adenopathy but less informative in detecting pleural and parenchymal disease. ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(88)90131-2
更新日期:1988-09-01 00:00:00
abstract::The polysplenia syndrome is the association of multiple spleens, situs inversus, congenital heart disease, and azygous continuation of the inferior vena cava. Magnetic resonance (MR) is a noninvasive imaging modality which can easily confirm the multiplicity of spleens, situs inversus, and identify complex congenital ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(89)90538-9
更新日期:1989-11-01 00:00:00
abstract::We propose a new method to determine wettability indices from NMR relaxometry. The new method uses the sensitivity of low field NMR relaxometry to the fluid distribution in oil-water saturated porous media. The model is based on the existence of a surface relaxivity for both oil and water, allowing the determination o...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(03)00145-0
更新日期:2003-04-01 00:00:00
abstract::A new approach is introduced for non-rigid registration of a pair of magnetic resonance images (MRI). It is a generalization of the demons algorithm with low computational cost, based on local information augmentation (by integrating multiple images) and balanced implementation. Specifically, a single deformation that...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2020.09.013
更新日期:2020-12-01 00:00:00
abstract::Current fast imaging techniques are based on gradient echo sequences with reduced flip angle excitation pulses and very short repetition times TR. Practical T2 values may be of the order of TR or longer. In this situation, a different image contrast can be obtained, depending on details of the sequence. Four essential...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章,评审
doi:10.1016/0730-725x(88)90472-9
更新日期:1988-07-01 00:00:00
abstract::Water content is the dominant chemical compound in the brain and it is the primary determinant of tissue contrast in magnetic resonance (MR) images. Water content varies greatly between individuals, and it changes dramatically over time from birth through senescence of the human life span. We hypothesize that the effe...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2013.07.017
更新日期:2013-12-01 00:00:00
abstract:PURPOSE:To evaluate whether semi-quantitative analysis of high temporal resolution dynamic contrast-enhanced MRI (DCE-MRI) acquired early in treatment can predict the response of locally advanced breast cancer (LABC) to neoadjuvant chemotherapy (NAC). MATERIALS AND METHODS:As part of an IRB-approved prospective study,...
journal_title:Magnetic resonance imaging
pub_type: 临床试验,杂志文章
doi:10.1016/j.mri.2013.07.002
更新日期:2013-11-01 00:00:00
abstract::Laplace inversion has been widely used in analyzing nuclear magnetic resonance data to obtain a spectrum of decay time constant, such as the T(2) spectrum. However, due to the ill-conditioned nature of such inversion, it is difficult to determine the reliability and error of the resulting spectrum. This article descri...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章,评审
doi:10.1016/j.mri.2006.11.023
更新日期:2007-05-01 00:00:00
abstract:PURPOSE:To evaluate the performance of combined integrated slice-by-slice shimming and readout-segmented EPI (irsEPI) for diffusion-weighted MR imaging (DWI) of the neck at 3Tesla. METHODS:This study was approved by the local ethics committee. An anthropometric phantom of the head/neck region incorporating compartment...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2017.05.004
更新日期:2017-10-01 00:00:00
abstract::Autoradiographic studies have shown that low dose ketamine produces increases in regional glucose utilisation and blood flow in the hippocampus, cerebral cortex, and olfactory lobe in the rat brain, probably due to antagonism at the NMDA receptor. Functional MRI using deoxyhaemoglobin contrast can be used to study cha...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(95)00010-e
更新日期:1995-01-01 00:00:00
abstract:PURPOSE:To determine the diagnostic performance of diffusion-weighted MRI and MR volumetry for the assessment of tumor response after preoperative chemoradiotherapy (CRT) in patients with locally advanced rectal cancer. MATERIALS AND METHODS:Forty-three patients with rectal cancer who underwent preoperative CRT were p...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2014.08.041
更新日期:2015-02-01 00:00:00
abstract::The nonhuman primate brain study provides important supplemental means for human brain exploration since the two species share close anatomical and functional similarities. MR diffusion tensor imaging (DTI) in human brain has revealed exquisite details of brain structures especially in the brain white matter. However,...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2008.07.004
更新日期:2009-04-01 00:00:00
abstract::Functional magnetic resonance imaging (fMRI) was used to investigate the spatial distribution of cortical activation in frontal and parietal lobes during auditory and visual oddball tasks in 10 healthy subjects. The purpose of the study was to compare activation within auditory and visual modalities and identify commo...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(00)00128-4
更新日期:2000-06-01 00:00:00
abstract::Magnetic resonance spectroscopy (MRS) is ideally suited for physiology-neurochemistry experiments with the living brain and particularly for studies on the primary visual cortex (striate cortex or area V1). Yet, the highly convoluted form of the human V1 has thus far prevented the performance of MRS investigations tha...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2007.03.008
更新日期:2007-07-01 00:00:00
abstract::The purpose of this study was to develop a multi-shot dual-echo breathhold fast spin echo technique (DFSE) and compare it with conventional spin echo (T2SE) for T(2)-weighted MR imaging of liver lesions. The DFSE acquisition (EffTE1/EffTE2/TR = 66/143/2100 ms) imaged 5 sections per 17 s breathhold. T2SE imaging (TE1/T...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(99)00120-4
更新日期:2000-02-01 00:00:00