Combination of integrated dynamic shimming and readout-segmented echo planar imaging for diffusion weighted MRI of the head and neck region at 3Tesla.

Abstract:

PURPOSE:To evaluate the performance of combined integrated slice-by-slice shimming and readout-segmented EPI (irsEPI) for diffusion-weighted MR imaging (DWI) of the neck at 3Tesla. METHODS:This study was approved by the local ethics committee. An anthropometric phantom of the head/neck region incorporating compartments with different diffusivities was constructed. In vivo measurements were performed in 10 healthy volunteers. DWI of the phantom and volunteers was performed on a 3Tesla MR scanner using single shot EPI (sEPI), a prototype single shot EPI with integrated slice-by-slice shimming (iEPI), readout segmented EPI (rsEPI) and a prototype readout segmented EPI with integrated shimming irsEPI. Apparent diffusion coefficients (ADC) and spatial distortions of phantom compartments were quantified. For phantom and volunteer measurements, the presence of geometric distortions, signal losses, ghosting artifacts as well as overall image quality were visually assessed on a 4-point scale by two radiologists in consensus. In addition, failure of fat saturation was assessed in volunteer data. RESULTS:Quantification of ADC within the phantom compartments was comparable using the different EPI techniques without significant variations. Using irsEPI, spatial distortions in phase-encoding direction were markedly reduced compared to iEPI, rsEPI and especially sEPI. irsEPI yielded significantly better overall image quality compared to sEPI, iEPI and rsEPI in phantom data as well as volunteer measurements. Markedly reduced geometric distortions and signal loss as well as better fat saturation were observed using irsEPI. CONCLUSION:The use of irsEPI significantly improves image quality and reduces artifacts caused by magnetic field inhomogeneities in EPI based DWI of the head/neck at 3Tesla.

journal_name

Magn Reson Imaging

authors

Walter SS,Liu W,Stemmer A,Martirosian P,Nikolaou K,Notohamiprodjo M,Gatidis S

doi

10.1016/j.mri.2017.05.004

subject

Has Abstract

pub_date

2017-10-01 00:00:00

pages

32-36

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(17)30099-1

journal_volume

42

pub_type

杂志文章
  • A simple way to acquire T(1)-weighted MR images of rat liver with respiratory triggering.

    abstract::To acquire high-resolution T(1)-weighted images of the liver in rats, for which breath-holding cannot be ensured, respiratory triggering is essential. At the respiratory rate of 30-60 times/min in rats, however, T(1)-weighted images cannot be obtained with simple triggering. As a simple solution to this, we applied mu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.10.005

    authors: Morikawa S,Murayama H,Fujimoto S,Shiino A,Inubushi T

    更新日期:2012-04-01 00:00:00

  • Correlations and dissociations between BOLD signal and P300 amplitude in an auditory oddball task: a parametric approach to combining fMRI and ERP.

    abstract::A parametric method is proposed to examine the relationship between neuronal activity, measured with event related potentials (ERPs), and the hemodynamic response, observed with functional magnetic resonance imaging (fMRI), during an auditory oddball paradigm. After verifying that the amplitude of the evoked response ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00496-4

    authors: Horovitz SG,Skudlarski P,Gore JC

    更新日期:2002-05-01 00:00:00

  • Assessment of normal flow patterns in the pulmonary circulation by using 4D magnetic resonance velocity mapping.

    abstract:OBJECTIVE:The purpose of this study was to analyze flow patterns in the pulmonary circulation of healthy volunteers by using 4D flow magnetic resonance imaging. MATERIALS AND METHODS:The study was approved by the local ethics committee and all subjects gave written informed consent. Eighteen volunteers underwent a 4D ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.036

    authors: Bächler P,Pinochet N,Sotelo J,Crelier G,Irarrazaval P,Tejos C,Uribe S

    更新日期:2013-02-01 00:00:00

  • Non-contrast enhanced 3D SSFP MRA of the renal allograft vasculature: a comparison between radial linear combination and Cartesian inflow-weighted acquisitions.

    abstract::Renal transplant patients often require imaging to ensure appropriate graft placement, to assess integrity of transplant vessel anastomosis and to evaluate for stenosis that can be a cause of graft failure. Because there is risk for nephrogenic systemic fibrosis in the setting of renal insufficiency, the use of non-co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.10.004

    authors: Bultman EM,Klaers J,Johnson KM,François CJ,Schiebler ML,Reeder SB,Block WF

    更新日期:2014-02-01 00:00:00

  • Magnetic resonance imaging of female pelvic masses and local recurrent tumors at an ultra low (0.02 T) magnetic field: correlation with computed tomography.

    abstract::Pelvic MR (41 patients) and CT (36 patients) examinations were performed on 14 females with a primary pelvic complaint, and on 28 females with a suspicion of local recurrent disease of gynecologic malignant tumor. Benign cystic tumors were found in eight patients, five patients had endometriomas, one had a lymphoma, a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90409-7

    authors: Varpula M

    更新日期:1993-01-01 00:00:00

  • High-resolution in vivo diffusion tensor imaging of the injured cat spinal cord using self-navigated, interleaved, variable-density spiral acquisition (SNAILS-DTI).

    abstract::Diffusion tensor magnetic resonance imaging (DTI) is useful for studying the microstructural changes in the spinal cord following traumatic injury; however, image quality is generally poor due to the small size of the spinal cord, physiological motion and susceptibility artifacts. Self-navigated, interleaved, variable...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.06.006

    authors: Ellingson BM,Sulaiman O,Kurpad SN

    更新日期:2010-11-01 00:00:00

  • Artificial intelligence in medical imaging.

    abstract::The medical specialty radiology has experienced a number of extremely important and influential technical developments in the past that have affected how medical imaging is deployed. Artificial intelligence (AI) is potentially another such development that will introduce fundamental changes into the practice of radiol...

    journal_title:Magnetic resonance imaging

    pub_type: 社论

    doi:10.1016/j.mri.2019.12.006

    authors: Gore JC

    更新日期:2020-05-01 00:00:00

  • Non-contrast-enhanced MR angiography in the diagnosis of Budd-Chiari syndrome (BCS) compared with digital subtraction angiography (DSA): Preliminary results.

    abstract::Non-CE MRA techniques (true steady-state free-precession, SSFP) have been used effectively for the selective visualization of the portal venous system and inferior vena cava. Budd-Chiari Syndrome (BCS) encompasses a number of conditions that cause the obstruction of the hepatic outflow tract from the small hepatic vei...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.10.006

    authors: Yang C,Li C,Zeng M,Lu X,Li J,Wang J,Sami MU,Xu K

    更新日期:2017-02-01 00:00:00

  • Utility of magnetization prepared GRE MRI for the detection of focal liver lesions.

    abstract::We compared the efficacy of rapidly acquired magnetization prepared gradient-echo (MP-GRE) sequences with CT and standard MRI pulse sequences for the detection of focal liver lesions. Fourteen patients with 28 focal liver lesions were scanned. TI times of 300, 450, and 600 ms were used. MP-GRE lesion conspicuity was c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92198-9

    authors: Winter TC 3rd,Freeny PC,Nghiem HV,Thomas CR Jr

    更新日期:1994-01-01 00:00:00

  • Regional variations in MR relaxation of hip joint cartilage in subjects with and without femoralacetabular impingement.

    abstract::The objective of this study was to analyze regional variations of magnetic resonance (MR) relaxation times (T1ρ and T2) in hip joint cartilage of healthy volunteers and subjects with femoral acetabular impingement (FAI). Morphological and quantitative images of the hip joints of 12 healthy volunteers and 9 FAI patient...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.01.009

    authors: Subburaj K,Valentinitsch A,Dillon AB,Joseph GB,Li X,Link TM,Vail TP,Majumdar S

    更新日期:2013-09-01 00:00:00

  • Automatic segmentation of brain white matter and white matter lesions in normal aging: comparison of five multispectral techniques.

    abstract::White matter loss, ventricular enlargement and white matter lesions are common findings on brain scans of older subjects. Accurate assessment of these different features is therefore essential for normal aging research. Recently, we developed a novel unsupervised classification method, named 'Multispectral Coloring Mo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.09.016

    authors: Valdés Hernández Mdel C,Gallacher PJ,Bastin ME,Royle NA,Maniega SM,Deary IJ,Wardlaw JM

    更新日期:2012-02-01 00:00:00

  • Bilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain.

    abstract::Deep brain stimulation (DBS) is used increasingly in the field of movement disorders. The implanted electrodes create not only a prior risk to patient safety during MRI, but also a unique opportunity in the collection of functional MRI data conditioned by direct neural stimulation. We evaluated MRI-related heating for...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.02.007

    authors: Bhidayasiri R,Bronstein JM,Sinha S,Krahl SE,Ahn S,Behnke EJ,Cohen MS,Frysinger R,Shellock FG

    更新日期:2005-05-01 00:00:00

  • Cardiovascular applications of magnetic resonance imaging.

    abstract::Magnetic resonance imaging (MRI) is a completely noninvasive modality that has shown significant promise for the evaluation of the cardiovascular system. Our imaging technique employed electrocardiographic (ECG) gating, which resulted in well-resolved images of the cardiac structures. Patients and animals with a varie...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(84)90002-x

    authors: McNamara MT,Higgins CB

    更新日期:1984-01-01 00:00:00

  • Study on the variations of the apparent diffusion coefficient in areas of solid tumor in high grade gliomas.

    abstract::Present knowledge suggests that in glioblastoma multiforme the value of the apparent diffusion coefficient (ADC) is elevated in the solid part and hyperintense in T1, in spite of the elevated cellularity, and also in areas where peritumoral vasogenic edema is present. The purpose of our study has been to verify in viv...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00594-5

    authors: Muti M,Aprile I,Principi M,Italiani M,Guiducci A,Giulianelli G,Ottaviano P

    更新日期:2002-11-01 00:00:00

  • Velocity distribution of slow fluid flows in Bentheimer sandstone: an NMRI and propagator study.

    abstract::This work addresses the special problems of measuring flow velocity distributions in rock by NMR methods. Specifically, these problems are to measure very slow flows as well as flows in the presence of background magnetic field gradients caused by heterogeneities of the rock. We modify a stimulated echo sequence for u...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00110-5

    authors: Waggoner RA,Fukushima E

    更新日期:1996-01-01 00:00:00

  • Diffusion of water in industrial cement and concrete.

    abstract::We propose a deuterium diffusion tracer approach to measure diffusion coefficient in the case of very short NMR relaxation times, too short for NMR pulsed field gradient sequences (T1 or T2 below 1 ms). We also treat the case of porous media containing metallic fibers (such as reinforced concrete) strongly disturbing ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.09.010

    authors: Fleury M,Berthe G,Chevalier T

    更新日期:2019-02-01 00:00:00

  • Effect of ovariectomy on contrast agent diffusion into lumbar intervertebral disc: a dynamic contrast-enhanced MRI study in female rats.

    abstract:PURPOSE:The purpose was to study the effect of estrogen deficiency on contrast agent diffusion into intervertebral disc in a rat model. MATERIALS AND METHODS:Seven-month-old female Sprague-Dawley rats were used. Fourteen rats had ovariectomy, and nine rats had sham surgery. Magnetic resonance imaging (MRI) of sagittal...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.01.001

    authors: Deng M,Griffith JF,Zhu XM,Poon WS,Ahuja AT,Wang YX

    更新日期:2012-06-01 00:00:00

  • A rapid method for the measurement and estimation of CO2 diffusivity in liquid hydrocarbon-saturated porous media using MRI.

    abstract::In this study, magnetic resonance imaging (MRI) was used to dynamically visualize the diffusion process of CO2 in porous media saturated with liquid hydrocarbon. Based on the assumption of semi-infinite media, effective CO2 diffusivity was obtained directly by the nonlinear fitting of one MR profile during the diffusi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.12.024

    authors: Zhao Y,Chen J,Yang M,Liu Y,Song Y

    更新日期:2016-05-01 00:00:00

  • Dixon-based fat-free MR-angiography compared to first pass and steady-state high-resolution MR-angiography using a blood pool contrast agent.

    abstract:INTRODUCTION:Compared to standard arterial-only first-pass MR-angiography (FPMRA), imaging during the equilibrium phase of a blood pool contrast agent (steady state) has been shown to provide higher image quality and better stenosis grading. Homogenous Dixon fat-suppression promises to increase contrast by suppression ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.07.005

    authors: Homsi R,Gieseke J,Kukuk GM,Träber F,Willinek WA,Schild HH,Hadizadeh DR

    更新日期:2015-11-01 00:00:00

  • Agarose as a tissue equivalent phantom material for NMR imaging.

    abstract::Phantoms for evaluation of nuclear magnetic resonance (NMR) imaging systems were made from water-based agarose gels, according to a standard procedure herein described. Copper sulfate (CuSO4) was included in the gels to further affect their proton relaxation characteristics. The proton relaxation rates of each batch o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(86)91068-4

    authors: Mitchell MD,Kundel HL,Axel L,Joseph PM

    更新日期:1986-01-01 00:00:00

  • Evaluation of a contraceptive device with MR imaging.

    abstract::The purpose of this investigation is to evaluate the positioning and to confirm the volume concept of the Lea's Shield diaphragm utilizing MR imaging. We evaluated the device in two women, one nulliparous and one multiparous. We were able to comprehensively evaluate the device in both patients and answer all questions...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00385-x

    authors: Maldjian C,Pelosi MA 2nd,Pelosi MA 3rd,Adam R

    更新日期:2001-06-01 00:00:00

  • Test-retest reliability of cerebral blood flow in healthy individuals using arterial spin labeling: Findings from the EMBARC study.

    abstract:INTRODUCTION:Previous investigations of test-retest reliability of cerebral blood flow (CBF) at rest measured with pseudo-continuous Arterial Spin Labeling (pCASL) demonstrated good reliability, but are limited by the use of similar scanner platforms. In the present study we examined test-retest reliability of CBF in r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.09.004

    authors: Almeida JRC,Greenberg T,Lu H,Chase HW,Fournier JC,Cooper CM,Deckersbach T,Adams P,Carmody T,Fava M,Kurian B,McGrath PJ,McInnis MG,Oquendo MA,Parsey R,Weissman M,Trivedi M,Phillips ML

    更新日期:2018-01-01 00:00:00

  • Automated measurement of fat infiltration in the hip abductors from Dixon magnetic resonance imaging.

    abstract:PURPOSE:Intramuscular fat infiltration is a dynamic process, in response to exercise and muscle health, which can be quantified by estimating fat fraction (FF) from Dixon MRI. Healthy hip abductor muscles are a good indicator of a healthy hip and an active lifestyle as they have a fundamental role in walking. The autom...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.06.019

    authors: Belzunce MA,Henckel J,Fotiadou A,Di Laura A,Hart A

    更新日期:2020-10-01 00:00:00

  • Highly homogeneous circularly polarized RF field for whole body NMR imaging.

    abstract::Conditions for generation of polarized RF fields in cylindrical symmetry by high order coils are presented. Whole body NMR transmitters utilizing this principle would require a current control on a certain number of loops. In the present design this is obtained by feeding each loop by an appropriate linear combination...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90398-0

    authors: Sotgiu A,Gualtieri G,Passariello R

    更新日期:1988-05-01 00:00:00

  • Correction of intensity nonuniformity in MR images of any orientation.

    abstract::The specialised radiofrequency (RF) coils used in MRI such as head or surface coils can give rise to marked image intensity nonuniformities. There are two situations in which it is essential to correct this: (1) When a global intensity threshold is used to segment particular tissues; and (2) in proton density images, ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90023-7

    authors: Wicks DA,Barker GJ,Tofts PS

    更新日期:1993-01-01 00:00:00

  • Determination of relaxation characteristics during preacute stage of lysophosphatidyl choline-induced demyelinating lesion in rat brain: an animal model of multiple sclerosis.

    abstract::Relaxation time measurements were carried out during the preacute stage of lesion progression in an animal model of demyelination created in the internal capsule (ic) area of the rat brain using lysophosphatidyl choline (LPC). T1 and T2 were determined both before and after 36 h of lesion creation. Histology carried o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.11.010

    authors: Degaonkar MN,Raghunathan P,Jayasundar R,Jagannathan NR

    更新日期:2005-01-01 00:00:00

  • Neuroprotective effect of agmatine in rats with transient cerebral ischemia using MR imaging and histopathologic evaluation.

    abstract:PURPOSE:This study aimed to further investigate the effects of agmatine on brain edema in the rats with middle cerebral artery occlusion (MCAO) injury using magnetic resonance imaging (MRI) monitoring and biochemical and histopathologic evaluation. MATERIALS AND METHODS:Following surgical induction of MCAO for 90min, ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.03.026

    authors: Huang YC,Tzeng WS,Wang CC,Cheng BC,Chang YK,Chen HH,Lin PC,Huang TY,Chuang TJ,Lin JW,Chang CP

    更新日期:2013-09-01 00:00:00

  • Effects of apodization smoothing and denoising on spectral fitting.

    abstract:PURPOSE:Visual review of individual spectra in magnetic resonance spectroscopic imaging (MRSI) data benefits from the application of spectral smoothing; however, if this processing step is applied prior to spectral analysis this can impact the accuracy of the quantitation. This study aims to analyze the effect of spect...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.04.013

    authors: Goryawala M,Sullivan M,Maudsley AA

    更新日期:2020-07-01 00:00:00

  • Spectroscopic imaging of the brain with phased-array coils at 3.0 T.

    abstract::The goal of this study was to develop and evaluate high-resolution magnetic resonance spectroscopic imaging (MRSI) utilizing the gains in signal-to-noise ratio (SNR) provided by combining higher magnetic field with high-sensitivity phased-array (PA) coils. We investigated the maximum improvement in spatial resolution ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.019

    authors: Xu D,Chen AP,Cunningham C,Osorio JA,Nelson SJ,Vigneron DB

    更新日期:2006-01-01 00:00:00

  • Functional magnetic resonance imaging in a stereotactic setup.

    abstract::The localization of critical structures within the brain is important for the planning of therapeutic strategies. Functional MRI is capable to assess functional response of cortical structures to certain stimuli. The authors present two techniques for functional MRI (fMRI) in a stereotactic set-up. The skull of the pa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)02108-x

    authors: Debus J,Essig M,Schad LR,Wenz F,Baudendistel K,Knopp MV,Engenhart R,Lorenz WJ

    更新日期:1996-01-01 00:00:00