Compensation of susceptibility-induced signal loss in echo-planar imaging for functional applications.

Abstract:

:Functional magnetic resonance imaging favors the use of multi-slice gradient-recalled echo-planar imaging due to its short image acquisition times, whole brain coverage and sensitivity to BOLD contrast. However, despite its advantages, gradient-recalled echo-planar imaging also is sensitive to static magnetic field gradients arising primarily from air-tissue interfaces. This can lead to image artifacts such as voxel shifts and complete signal loss. A method to recover signal loss by adjusting the refocusing gradient amplitude in the slice-select direction, preferably axially, is proposed. This method is implemented as an automated computer algorithm that partitions echo-planar images into regions of recoverable signal intensities using a histogram analysis and determines each region's proper refocusing gradient amplitude. As an example, different refocusing gradient amplitudes are interleaved in a fMRI acquisition to maximize the signal to noise ratio and obtain functional activation in normal and dropout regions. The effectiveness of this method is demonstrated by recovering signal voids in the orbitofrontal cortex, parahippocampal/amygdala region, and inferior visual association cortex near the cerebellum.

journal_name

Magn Reson Imaging

authors

Cordes D,Turski PA,Sorenson JA

doi

10.1016/s0730-725x(00)00199-5

subject

Has Abstract

pub_date

2000-11-01 00:00:00

pages

1055-68

issue

9

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(00)00199-5

journal_volume

18

pub_type

杂志文章
  • Electric stimulation fMRI of the perforant pathway to the rat hippocampus.

    abstract::The hippocampal formation is a brain system that is implicated in learning and memory. The major input to the hippocampus arrives from the entorhinal cortex (EC) to the dentate gyrus (DG) through the perforant path. In the present work, we have investigated the functional properties of this connection by concomitantly...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2008.02.018

    authors: Canals S,Beyerlein M,Murayama Y,Logothetis NK

    更新日期:2008-09-01 00:00:00

  • Assessment of the anomalous pulmonary circulation by dynamic contrast-enhanced MR angiography in under four seconds.

    abstract::The purpose of this study was to demonstrate the initial results of the dynamic contrast-enhanced MRA in under four seconds in the assessment of anomalous pulmonary circulation. We performed dynamic contrast enhanced MRA on ten patients with a temporal resolution of 2-3 sec for each phase. Five patients had pulmonary ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00634-3

    authors: Balci NC,Yalçin Y,Tunaci A,Balci Y

    更新日期:2003-01-01 00:00:00

  • Fast and high-resolution quantitative mapping of tissue water content with full brain coverage for clinically-driven studies.

    abstract::An efficient method for obtaining longitudinal relaxation time (T1) maps is based on acquiring two spoiled gradient recalled echo (SPGR) images in steady states with different flip angles, which has also been extended, with additional acquisitions, to obtain a tissue water content (M0) map. Several factors, including ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.08.001

    authors: Sabati M,Maudsley AA

    更新日期:2013-12-01 00:00:00

  • COmplex-Model-Based Estimation of thermal noise for fMRI data in the presence of artifacts.

    abstract::Due to the presence of artifacts induced by fast-imaging acquisition in functional magnetic resonance imaging (fMRI) studies, it is very difficult to estimate the variance of thermal noise by traditional methods in magnitude images. Moreover, the existence of incidental phase fluctuations impairs the validity of curre...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.12.007

    authors: Xu Y,Wu G,Rowe DB,Ma Y,Zhang R,Xu G,Li SJ

    更新日期:2007-09-01 00:00:00

  • Incidental magnetization transfer contrast in standard multislice imaging.

    abstract::Radio frequency magnetic fields from 5 to 100 kHz off resonance reduce longitudinal magnetization of water in some tissues without affecting the magnetization of simple solutions (Wolff, S.D.; Balaban, R.S. Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo. Magn. Reson. Med. 10:135-144; ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90050-c

    authors: Dixon WT,Engels H,Castillo M,Sardashti M

    更新日期:1990-01-01 00:00:00

  • Equivalent cross relaxation rate image for decreasing a false negative case of sentinel lymph node biopsy.

    abstract::In the breast carcinamas, sentinel lymph node biopsy (SLNB) attracts attention as technique to be settled by axillary lymph node metastasis, but existence of a false negative case is a problem. Equivalent cross relaxation rate image (ECRI) is the measurement method that we can evaluate a change of organization structu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(03)00208-x

    authors: Matsushima S,Sasaki F,Sarumaru S,Ohta D,Era S,Sogami M,Inaba T,Kinosada Y

    更新日期:2003-11-01 00:00:00

  • A CT using longitudinally detected ESR (LODESR-CT) of intraperitoneally injected nitroxide radical in a rat's head.

    abstract::We have developed an in vivo longitudinally detected ESR (LODESR) imaging system operating at 700 MHz based on a loop-gap resonator and a pair of saddle-type pickup coils. A good linear relationship between the LODESR signal intensity and the applied power in a range up to 15.8 W was obtained. The detection of LODESR ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)82763-4

    authors: Yokoyama H,Sato T,Tsuchihashi N,Ogata T,Ohya-Nishiguchi H,Kamada H

    更新日期:1997-01-01 00:00:00

  • Rapid and recoverable in vivo magnetic resonance imaging of the adult zebrafish at 7T.

    abstract::Increasing scientific interest in the zebrafish as a model organism across a range of biomedical and biological research areas raises the need for the development of in vivo imaging tools appropriate to this subject. Development of the embryonic and early stage forms of the subject can currently be assessed using opti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.10.013

    authors: Merrifield GD,Mullin J,Gallagher L,Tucker C,Jansen MA,Denvir M,Holmes WM

    更新日期:2017-04-01 00:00:00

  • Relationship between neural and hemodynamic signals during spontaneous activity studied with temporal kernel CCA.

    abstract::Functional magnetic resonance imaging (fMRI) based on the so-called blood oxygen level-dependent (BOLD) contrast is a powerful tool for studying brain function not only locally but also on the large scale. Most studies assume a simple relationship between neural and BOLD activity, in spite of the fact that it is impor...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.12.016

    authors: Murayama Y,Biessmann F,Meinecke FC,Müller KR,Augath M,Oeltermann A,Logothetis NK

    更新日期:2010-10-01 00:00:00

  • Magnetization transfer of water T(2) relaxation components in human brain: implications for T(2)-based segmentation of spectroscopic volumes.

    abstract::Biexponential T(2) relaxation of the localized water signal can be used for segmentation of spectroscopic volumes. To assess the specificity of the components an iterative relaxation measurement of the localized water signal (STEAM, 12 echo times, geometric spacing from 30 ms to 2000 ms) was combined with magnetizatio...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00396-4

    authors: Helms G,Piringer A

    更新日期:2001-07-01 00:00:00

  • Characteristics of geometric distortion correction with increasing field-of-view in open-configuration MRI.

    abstract::Open-configuration magnetic resonance imaging (MRI) systems are becoming increasingly desirable for musculoskeletal imaging and image-guided radiotherapy because of their non-claustrophobic configuration. However, geometric image distortion in large fields-of-view (FOV) due to field inhomogeneity and gradient nonlinea...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.02.007

    authors: Hong C,Lee DH,Han BS

    更新日期:2014-07-01 00:00:00

  • Functional magnetic resonance imaging in a stereotactic setup.

    abstract::The localization of critical structures within the brain is important for the planning of therapeutic strategies. Functional MRI is capable to assess functional response of cortical structures to certain stimuli. The authors present two techniques for functional MRI (fMRI) in a stereotactic set-up. The skull of the pa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)02108-x

    authors: Debus J,Essig M,Schad LR,Wenz F,Baudendistel K,Knopp MV,Engenhart R,Lorenz WJ

    更新日期:1996-01-01 00:00:00

  • Quantitative determination of porosity: a local assessment by NMR imaging techniques.

    abstract::The local determination of porosity is an extremely valuable target because of different applications in petrophysics. In fact, obtaining a reliable profile of porosity or saturations could considerably improve the evaluation of transport properties of porous media, especially if applied to multiphase flow test (i.e.,...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00182-8

    authors: Borgia GC,Bortolotti V,Dattilo P,Fantazzini P,Maddinelli G

    更新日期:1996-01-01 00:00:00

  • Considerations in applying 3D PRESS H-1 brain MRSI with an eight-channel phased-array coil at 3 T.

    abstract::The purpose of this study was to assess the benefits of a 3 T scanner and an eight-channel phased-array head coil for acquiring three-dimensional PRESS (Point REsolved Spectral Selection) proton (H-1) magnetic resonance spectroscopic imaging (MRSI) data from the brains of volunteers and patients with brain tumors rela...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.07.012

    authors: Li Y,Osorio JA,Ozturk-Isik E,Chen AP,Xu D,Crane JC,Cha S,Chang S,Berger MS,Vigneron DB,Nelson SJ

    更新日期:2006-12-01 00:00:00

  • A purpose-built neck coil for black-blood DANTE-prepared carotid artery imaging at 7T.

    abstract::Atherosclerotic plaques in the bifurcation of the carotid arteries can pose a significant health risk due to possible plaque rupture and subsequent stroke. The assessment of plaques, and evaluation of the risk they pose, can be performed with Black-Blood (BB) vessel wall magnetic resonance imaging. However, resolution...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.04.011

    authors: Papoutsis K,Li L,Near J,Payne S,Jezzard P

    更新日期:2017-07-01 00:00:00

  • Artifacts in chemical shift selective imaging.

    abstract::The role of susceptibility effects in the production of artifacts in chemical shift images generated by the selective excitation technique is discussed. The effects are demonstrated in images of phantom samples of agarose gels containing small air bubbles. The artifacts can lead to erroneous interpretations, in which ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90022-r

    authors: Pope JM,Walker RR,Kron T

    更新日期:1992-01-01 00:00:00

  • Factors influencing contrast in fast spin-echo MR imaging.

    abstract::Multi-echo pulse sequences for producing T2-weighted images in much reduced imaging times have recently been developed for routine clinical use. A number of recent articles have described the contrast obtained with fast spin-echo (FSE) sequences and have generally indicated that they depict tissues very similarly to c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(92)90001-g

    authors: Constable RT,Anderson AW,Zhong J,Gore JC

    更新日期:1992-01-01 00:00:00

  • The reliability of routine clinical post-processing software in assessing potential diffusion-weighted MRI "biomarkers" in brain metastases.

    abstract:BACKGROUND AND PURPOSE:Diffusion MRI characteristics have been used as biomarkers to guide prognosis in cerebral pathologies including brain metastases. The measurement of ADC is often described poorly in clinical and research studies with little detail given to the practical considerations of where to place ROIs, whic...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.12.010

    authors: Zakaria R,Das K,Bhojak M,Radon M,Sluming V,Walker C,Jenkinson MD

    更新日期:2014-04-01 00:00:00

  • A fast spin echo two-point Dixon technique and its combination with sensitivity encoding for efficient T2-weighted imaging.

    abstract::A fast spin echo two-point Dixon (fast 2PD) technique was developed for efficient T2-weighted imaging with uniform water and fat separation. The technique acquires two interleaved fast spin echo images with water and fat in-phase and 180 degrees out-of-phase, respectively, and generates automatically separate water an...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.005

    authors: Ma J,Son JB,Bankson JA,Stafford RJ,Choi H,Ragan D

    更新日期:2005-12-01 00:00:00

  • Optimized 3D bright blood MRI of aortic plaque at 3 T.

    abstract:PURPOSE:To evaluate the feasibility of an optimized bright blood MRI protocol at 3 T in combination with contrast agent administration for the detection and characterization of aortic high-risk plaques for the improved workup of acute stroke patients. MATERIALS AND METHODS:ECG synchronized T1-weighted 3D gradient echo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.08.010

    authors: Markl M,Dudler P,Fydrychowicz A,Strecker C,Weiller C,Hennig J,Harloff A

    更新日期:2008-04-01 00:00:00

  • MRI-assisted radiation therapy planning of brain tumors--clinical experiences in 17 patients.

    abstract::A new and simple method for precise determination of lateral opposed treatment portals was developed and used in 17 patients. Compared to CT, MRI led to significant changes of portals in 59% (10/17) of cases. Individual shielding blocks could be precisely designed by use of our new method. MRI is the procedure of choi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(91)90007-9

    authors: Just M,Rösler HP,Higer HP,Kutzner J,Thelen M

    更新日期:1991-01-01 00:00:00

  • MRI of the anal canal: correlation with histologic examination.

    abstract::The purpose of this study was to correlate the MRI features of the anal canal with histologic findings. T1- and T2-weighted MR images of nine anal canals were obtained after fixation in 10% formalin. In three specimens, imaging was repeated after removal of histologic layers with a dissecting microscope. Corresponding...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02056-y

    authors: Van Beers BE,Kartheuser A,Delos MA,Grandin C,Detry R,Jamart J,Pringot J

    更新日期:1996-01-01 00:00:00

  • Characterisation of crosslinked elastomeric materials by 1H NMR relaxation time distributions.

    abstract::One of the most critical structural parameters in elastomeric materials is the density of cross-linking between the polymeric chains. This chemical feature greatly affects chain motions and is determinant in controlling mechanical properties of the final product. NMR techniques are widely and efficiently applied to in...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00257-0

    authors: Borgia GC,Fantazzini P,Ferrando A,Maddinelli G

    更新日期:2001-04-01 00:00:00

  • Electric current density imaging of bone by MRI.

    abstract::Current density imaging (CDI) has been shown to be a feasible method to map spatial distribution of electric currents through bone structures and for studying osteoporosis and bone fracture models. For the osteoporosis model, bone sample was moistened in a solution of a sodium salt of ethylendiamintetraacetic acid (ED...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00038-6

    authors: Beravs K,White D,Sersa I,Demsar F

    更新日期:1997-01-01 00:00:00

  • Is 'virtual histology' the next step after the 'virtual autopsy'? Magnetic resonance microscopy in forensic medicine.

    abstract:AIM:The study aimed to validate magnetic resonance microscopy (MRM) studies of forensic tissue specimens (skin samples with electric injury patterns) against the results from routine histology. METHODS AND RESULTS:Computed tomography and magnetic resonance imaging are fast becoming important tools in clinical and fore...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.08.019

    authors: Thali MJ,Dirnhofer R,Becker R,Oliver W,Potter K

    更新日期:2004-10-01 00:00:00

  • Spine MR images in patients with pedicle screw fixation: Comparison of conventional and SEMAC-VAT sequences at 1.5 T.

    abstract:BACKGROUND AND PURPOSE:Slice-encoding metal artifact corrections (SEMAC)-view-angle tilting (VAT) sequences have recently been used in clinical protocols to reduce metal artifacts in MR scans of patients with spinal instrumentation. The objective of this study was to compare the SEMAC-VAT sequence with the conventional...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.08.002

    authors: Park C,Lee E,Yeo Y,Kang Y,Lee JW,Ahn JM,Kang HS

    更新日期:2018-12-01 00:00:00

  • Analysis of kinetic curve and model-based perfusion parameters on dynamic contrast enhanced MRI in breast cancer patients: Correlations with dominant stroma type.

    abstract:OBJECTIVE:Our purpose was to evaluate imaging findings of breast cancers according to the dominant stroma type by using kinetic curve analysis and model-based perfusion parameters from dynamic contrast-enhanced magnetic resonance imaging. METHODS:From March 2011 to September 2011, 64 cancers in 64 patients were includ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.07.010

    authors: Yim H,Kang DK,Jung YS,Jeon GS,Kim TH

    更新日期:2016-01-01 00:00:00

  • Fast T2-mapping with snapshot flash imaging.

    abstract::It has been shown recently that quantitative T2-maps may be measured by acquisition of a series of at least eight T2-weighted SNAPSHOT FLASH images. These measurements require a relaxation delay of 10-15 s after each T2-weighted image for the complete relaxation of the spin system. This results in long measuring times...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)00004-z

    authors: Deichmann R,Adolf H,Nöth U,Morrissey S,Schwarzbauer C,Haase A

    更新日期:1995-01-01 00:00:00

  • Accurate and sensitive measurements of magnetic susceptibility using echo planar imaging.

    abstract::Susceptibility differences are common causes for artifacts in magnetic resonance (MR); therefore, it is important to choose phantom materials in a way that these artifacts are kept at a minimum. In this study, a previously proposed MR imaging (MRI) method [Beuf O, Briguet A, Lissac M, Davis R. Magnetic resonance imagi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.07.005

    authors: Carlsson A,Starck G,Ljungberg M,Ekholm S,Forssell-Aronsson E

    更新日期:2006-11-01 00:00:00

  • MAgnitude and PHase Thresholding (MAPHT) of noisy complex-valued magnetic resonance images.

    abstract::It is often desirable to separate voxels that contain signal from tissue along with measurement noise from those that contain purely measurement noise. Generally, this separation called thresholding utilizes only the magnitude portion of the images. Recently, methods have been developed that utilize both the magnitude...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.008

    authors: Rowe DB,Haacke EM

    更新日期:2009-11-01 00:00:00