Fast Field Echo imaging: an overview and contrast calculations.

Abstract:

:Current fast imaging techniques are based on gradient echo sequences with reduced flip angle excitation pulses and very short repetition times TR. Practical T2 values may be of the order of TR or longer. In this situation, a different image contrast can be obtained, depending on details of the sequence. Four essentially different versions of the basic Fast Field Echo (FFE) sequence can be distinguished and are described systematically in this article. For these sequences, image contrast formulas are presented. Practical imaging should tolerate small field inhomogeneities. This requirement can be satisfied by only three of the four versions. Numerical simulations are used to study the influence of a modified phase alternation scheme on image contrasts of two of the remaining sequences. The results of the calculations are verified by phantom studies on a 1.5-T whole-body imager. Implications for contrast in clinical images are discussed in relation to head images obtained on the same machine.

journal_name

Magn Reson Imaging

authors

van der Meulen P,Groen JP,Tinus AM,Bruntink G

doi

10.1016/0730-725x(88)90472-9

subject

Has Abstract

pub_date

1988-07-01 00:00:00

pages

355-68

issue

4

eissn

0730-725X

issn

1873-5894

pii

0730-725X(88)90472-9

journal_volume

6

pub_type

杂志文章,评审
  • In vivo mapping of functional domains and axonal connectivity in cat visual cortex using magnetic resonance imaging.

    abstract::Noninvasive cognitive neuroimaging studies based on functional magnetic resonance imaging (fMRI) are of ever-increasing importance for basic and clinical neurosciences. The explanatory power of fMRI could be greatly expanded, however, if the pattern of the neuronal circuitry underlying functional activation could be m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.08.014

    authors: Kim DS,Kim M,Ronen I,Formisano E,Kim KH,Ugurbil K,Mori S,Goebel R

    更新日期:2003-12-01 00:00:00

  • Isotropically weighted intravoxel incoherent motion brain imaging at 7T.

    abstract::Perfusion magnetic resonance imaging (MRI) is a promising non-invasive technique providing insights regarding the brain's microvascular architecture in vivo. The scalar perfusion metrics can be used for quantitative diagnostics of various brain abnormalities, in particular, in the stroke cases and tumours. However, co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.11.007

    authors: Maximov II,Vellmer S

    更新日期:2019-04-01 00:00:00

  • Evidence for left-right asymmetries in the proton MRS of brain in normal volunteers.

    abstract::Although there is ample evidence in the literature for structural, functional and physiological asymmetries in the two hemispheres of human brain, direct evidence of a similar asymmetry in the in vivo distribution of brain metabolites has been lacking. In this study, the existence of chemical asymmetries in six differ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00342-6

    authors: Jayasundar R,Raghunathan P

    更新日期:1997-01-01 00:00:00

  • Combination of integrated dynamic shimming and readout-segmented echo planar imaging for diffusion weighted MRI of the head and neck region at 3Tesla.

    abstract:PURPOSE:To evaluate the performance of combined integrated slice-by-slice shimming and readout-segmented EPI (irsEPI) for diffusion-weighted MR imaging (DWI) of the neck at 3Tesla. METHODS:This study was approved by the local ethics committee. An anthropometric phantom of the head/neck region incorporating compartment...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.05.004

    authors: Walter SS,Liu W,Stemmer A,Martirosian P,Nikolaou K,Notohamiprodjo M,Gatidis S

    更新日期:2017-10-01 00:00:00

  • Dependence of BOLD signal change on tactile stimulus intensity in SI of primates.

    abstract::Recently, we have demonstrated that the fine-digit topography (millimeter sized) previously identified in the primary somatosensory cortex (SI), using electrophysiology and intrinsic signal optical imaging, can also be mapped with submillimeter resolution using blood-oxygenation-level-dependent (BOLD) functional magne...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.05.002

    authors: Zhang N,Gore JC,Chen LM,Avison MJ

    更新日期:2007-07-01 00:00:00

  • Noninvasive evaluation of radiation-enhanced glioma cells invasiveness by ultra-high-field (1)H-MRS in vitro.

    abstract:INTRODUCTION:Glioma is the most common type of the primary CNS tumor. Radiotherapy is an important treatment measure after surgery. However, its highly invasive character is the main reason of postoperative recurrence. The aim of the study was to probe the correlation between the invasion ability and the metabolite cha...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.05.009

    authors: Xu YJ,Cui Y,Li HX,Shi WQ,Li FY,Wang JZ,Zeng QS

    更新日期:2016-10-01 00:00:00

  • Drug monitoring of 5-fluorouracil: in vivo 19F NMR study during 5-FU chemotherapy in patients with metastases of colorectal adenocarcinoma.

    abstract::The metabolism of 5-fluorouracil (5-FU) is complex and the reason for the low response rate of tumor patients to 5-FU is currently unknown. The aim of this study was to evaluate whether spectral parameters obtained noninvasively by in vivo 19F nuclear magnetic resonance (NMR) spectroscopy can be used to assess individ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)92544-5

    authors: Schlemmer HP,Bachert P,Semmler W,Hohenberger P,Schlag P,Lorenz WJ,van Kaick G

    更新日期:1994-01-01 00:00:00

  • 3D cerebrovascular segmentation combining fuzzy vessel enhancement and level-sets with anisotropic energy weights.

    abstract::The aim of this work is to present and evaluate a level-set segmentation approach with vesselness-dependent anisotropic energy weights, which focuses on the exact segmentation of malformed as well as small vessels from time-of-flight (TOF) magnetic resonance angiography (MRA) datasets. In a first step, a vesselness fi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.07.008

    authors: Forkert ND,Schmidt-Richberg A,Fiehler J,Illies T,Möller D,Säring D,Handels H,Ehrhardt J

    更新日期:2013-02-01 00:00:00

  • Diffusion of liquids into semicrystalline polyethylene.

    abstract::Pulsed field gradient (PFG) nuclear magnetic resonance (NMR) and microimaging experiments have been performed to study the diffusion of liquid alkanes into a variety of semicrystalline polyethylene (PE) samples. The results highlight the importance of the crystalline phase in controlling the diffusion process in terms...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00032-0

    authors: Harding SG,Gladden LF

    更新日期:1998-06-01 00:00:00

  • A simple way to acquire T(1)-weighted MR images of rat liver with respiratory triggering.

    abstract::To acquire high-resolution T(1)-weighted images of the liver in rats, for which breath-holding cannot be ensured, respiratory triggering is essential. At the respiratory rate of 30-60 times/min in rats, however, T(1)-weighted images cannot be obtained with simple triggering. As a simple solution to this, we applied mu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.10.005

    authors: Morikawa S,Murayama H,Fujimoto S,Shiino A,Inubushi T

    更新日期:2012-04-01 00:00:00

  • Reducing motion artifacts in two-dimensional Fourier transform imaging.

    abstract::The effects of motion in two-dimensional Fourier transform imaging (2DFT) are considered. Specific calculations describing the case of periodic motion are presented. The results predict the commonly seen artifact of image replication, sometimes referred to as ghosting. Expressions for both position and amplitude of th...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(86)91046-5

    authors: Haacke EM,Patrick JL

    更新日期:1986-01-01 00:00:00

  • Monitoring brain tumor response to therapy using MRI segmentation.

    abstract::The performance evaluation of a semi-supervised fuzzy c-means (SFCM) clustering method for monitoring brain tumor volume changes during the course of routine clinical radiation-therapeutic and chemo-therapeutic regimens is presented. The tumor volume determined using the SFCM method was compared with the volume estima...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00386-4

    authors: Vaidyanathan M,Clarke LP,Hall LO,Heidtman C,Velthuizen R,Gosche K,Phuphanich S,Wagner H,Greenberg H,Silbiger ML

    更新日期:1997-01-01 00:00:00

  • On the R2⁎ relaxometry in complex multi-peak multi-Echo chemical shift-based water-fat quantification: Applications to the neuromuscular diseases.

    abstract:PURPOSE:Investigation of the feasibility of the R2⁎ mapping techniques by using latest theoretical models corrected for confounding factors and optimized for signal to noise ratio. THEORY AND METHODS:The improvement of the performance of state of the art magnetic resonance imaging (MRI) relaxometry algorithms is chall...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.08.006

    authors: Siracusano G,La Corte A,Milazzo C,Anastasi GP,Finocchio G,Gaeta M

    更新日期:2017-01-01 00:00:00

  • Influence of excess ligand on Nephrogenic Systemic Fibrosis associated with nonionic, linear gadolinium-based contrast agents.

    abstract:BACKGROUND:The molecular structure, charge, thermodynamic and kinetic stability are approximately the same for gadodiamide and gadoversetamide, the main substantive difference is that gadodiamide is manufactured with 5% free ligand to form Omniscan® and gadoversetamide with 10% free ligand to form OptiMARK®. PURPOSE:T...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.11.015

    authors: Semelka RC,Prybylski JP,Ramalho M

    更新日期:2019-05-01 00:00:00

  • Optimal real-time estimation in diffusion tensor imaging.

    abstract::Diffusion tensor imaging (DTI) constitutes the most used paradigm among the diffusion-weighted magnetic resonance imaging (DW-MRI) techniques due to its simplicity and application potential. Recently, real-time estimation in DW-MRI has deserved special attention, with several proposals aiming at the estimation of mean...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.12.001

    authors: Casaseca-de-la-Higuera P,Tristán-Vega A,Aja-Fernández S,Alberola-López C,Westin CF,San José Estépar R

    更新日期:2012-05-01 00:00:00

  • Application of machine learning methods to describe the effects of conjugated equine estrogens therapy on region-specific brain volumes.

    abstract::Use of conjugated equine estrogens (CEE) has been linked to smaller regional brain volumes in women aged ≥65 years; however, it is unknown whether this results in a broad-based characteristic pattern of effects. Structural magnetic resonance imaging was used to assess regional volumes of normal tissue and ischemic les...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.mri.2010.12.001

    authors: Casanova R,Espeland MA,Goveas JS,Davatzikos C,Gaussoin SA,Maldjian JA,Brunner RL,Kuller LH,Johnson KC,Mysiw WJ,Wagner B,Resnick SM,Women's Health Initiative Memory Study.

    更新日期:2011-05-01 00:00:00

  • Test-retest reliability of cerebral blood flow in healthy individuals using arterial spin labeling: Findings from the EMBARC study.

    abstract:INTRODUCTION:Previous investigations of test-retest reliability of cerebral blood flow (CBF) at rest measured with pseudo-continuous Arterial Spin Labeling (pCASL) demonstrated good reliability, but are limited by the use of similar scanner platforms. In the present study we examined test-retest reliability of CBF in r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.09.004

    authors: Almeida JRC,Greenberg T,Lu H,Chase HW,Fournier JC,Cooper CM,Deckersbach T,Adams P,Carmody T,Fava M,Kurian B,McGrath PJ,McInnis MG,Oquendo MA,Parsey R,Weissman M,Trivedi M,Phillips ML

    更新日期:2018-01-01 00:00:00

  • Diffusion of water in industrial cement and concrete.

    abstract::We propose a deuterium diffusion tracer approach to measure diffusion coefficient in the case of very short NMR relaxation times, too short for NMR pulsed field gradient sequences (T1 or T2 below 1 ms). We also treat the case of porous media containing metallic fibers (such as reinforced concrete) strongly disturbing ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.09.010

    authors: Fleury M,Berthe G,Chevalier T

    更新日期:2019-02-01 00:00:00

  • Aligning 3D time-of-flight MRA datasets for quantitative longitudinal studies: evaluation of rigid registration techniques.

    abstract:OBJECTIVE:3D Time-of-flight (TOF) magnetic resonance angiography is commonly used for vascular analyses. A quantification of longitudinal morphological changes usually requires the registration of TOF image sequences acquired at different time points. The aim of this study was to evaluate the precision of different 3D ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.08.011

    authors: Verleger T,Schönfeld M,Säring D,Siemonsen S,Fiehler J,Forkert ND

    更新日期:2014-12-01 00:00:00

  • Fast magnetic resonance in vascular diseases of the abdomen.

    abstract::Fast magnetic resonance (MR) imaging provides a consistent and predictable appearance of vascular abnormalities as shown by four patients with thrombi, dissection and aneurysm. Fast MR images are obtained during breath-holding, resulting in an absence of respiratory motion artifacts. The time of MR study is much less ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90483-3

    authors: Raval B,Kulkarni M,Narayana P,Mehta S

    更新日期:1988-07-01 00:00:00

  • Simultaneous imaging of locus coeruleus and substantia nigra with a quantitative neuromelanin MRI approach.

    abstract::Quantitative MRI of neuromelanin (NM) containing structures (referred to as NM-MRI) in the brainstem, namely the locus coeruleus (LC) and substantia nigra (SN), may assist with the early detection of Parkinson's disease (PD) and Alzheimer's disease (AD) as well as differential diagnosis in the early disease stages. In...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.07.003

    authors: Chen X,Huddleston DE,Langley J,Ahn S,Barnum CJ,Factor SA,Levey AI,Hu X

    更新日期:2014-12-01 00:00:00

  • Off-resonance frequency filtered magnetic resonance imaging.

    abstract::One of the main problems with rapid magnetic resonance imaging (MRI) techniques is the artifacts that result from off-resonance effects. The proposed off-resonance frequency filtered MRI (OFF-MRI) method focuses on the elimination of off-resonance components from the image of the observed object. To maintain imaging s...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.12.027

    authors: Medic J,Tomazic S

    更新日期:2010-05-01 00:00:00

  • Idiopathic dilatation of the pulmonary artery: report of four cases.

    abstract::Idiopathic dilatation of the pulmonary artery (IDPA) is a rare congenital disease which is usually detected fortuitously on chest x-ray, thus radiologists must be aware of this clinical entity. This report describes four cases to which Magnetic Resonance Imaging (MRI) played a major role in diagnosing IDPA and in dete...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00013-2

    authors: Ugolini P,Mousseaux E,Sadou Y,Sidi D,Mercier LA,Paquet E,Gaux JC

    更新日期:1999-07-01 00:00:00

  • Breath-hold T2-weighted sequences of the liver: a comparison of four techniques at 1.0 and 1.5 T.

    abstract::T2-weighted images are considered the most sensitive for lesion detection at high field; however, long imaging time is problematic. Accordingly, the authors compared four breath-hold T2 or T2* weighted sequences comprising T2*-weighted FLASH, T2*-weighted PSIF, T2-weighted rapid spin echo (RASE), and T2-weighted Turbo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90371-6

    authors: Simm FC,Semelka RC,Recht M,Deimling M,Lenz G,Laub GA

    更新日期:1992-01-01 00:00:00

  • Synovial sarcoma: MR imaging.

    abstract::Ten patients with biopsy-proved synovial sarcoma were evaluated by magnetic resonance (MR) imaging on a 1.5-T unit. The lesions showed intermediate signal intensity on T1-weighted images and heterogeneous high signal intensity on T2-weighted images. Tumors were well-demarcated from normal tissues. Additional informati...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90706-6

    authors: Mahajan H,Lorigan JG,Shirkhoda A

    更新日期:1989-03-01 00:00:00

  • 1H magnetic resonance imaging and 31P magnetic resonance spectroscopy in experimental filariasis.

    abstract::1H Magnetic resonance imaging and 31P magnetic resonance spectroscopy (MRS) have been carried out in experimental rodent filariasis, i.e., Acanthocheilonema viteae infection in the rodent host, Mastomys coucha. The T2-weighted image of the infected host shows fine hyperintense thread like structures of adult filariid ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00180-x

    authors: Shukla-Dave A,Fatma N,Roy R,Srivastava S,Chatterjee RK,Govindaraju V,Viswanathan AK,Raghunathan P

    更新日期:1997-01-01 00:00:00

  • Partial angle inversion recovery (PAIR) MR imaging: spin-echo and snapshot implementation.

    abstract::The effects of varying the inversion or excitation RF pulse flip angles on image contrast and imaging time have been investigated in IR imaging theoretically, with phantoms and with normal volunteers. Signal intensity in an IR pulse sequence as a function of excitation, inversion and refocusing pulse flip angles was c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90481-e

    authors: Vinitski S,Albert S,Mitchell DG,Tasciyan TA,Rifkin MD

    更新日期:1992-01-01 00:00:00

  • In-plane flow velocity quantification along the phase encoding axis in MRI.

    abstract::In-plane flow quantification in MRI offers the potential for assessing vessel patency, and both volume flow rate and flow velocity. These techniques will have definite future impact on MR angiography. The method used in this paper employs motion artifact suppression technique (MAST) gradients to refocus spins travelli...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(88)90409-2

    authors: Duerk JL,Pattany PM

    更新日期:1988-05-01 00:00:00

  • MR imaging of cervical spine motion with HASTE.

    abstract::The HASTE (half-Fourier acquisition single-shot turbo spin-echo) technique delivers images with T2-weighting in about half a second and could be ideal for fast dynamic studies when T2-weighting is needed. We evaluated cardiac-triggered HASTE to study cervical spine flexion/extension. The cervical spines of ten asympto...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00176-3

    authors: Duerinckx AJ,Yu WD,El-Saden S,Kim D,Wang JC,Sandhu HS

    更新日期:1999-04-01 00:00:00

  • High-resolution MR venography of cerebral arteriovenous malformations.

    abstract::The purpose of this study was to evaluate the diagnostic potential of a high-resolution magnetic resonance (MR) venography technique in patients with cerebral arteriovenous malformations (AVMs). A high-resolution 3D gradient echo sequence was used with a long echo time TE to obtain venous information down to sub-pixel...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00084-3

    authors: Essig M,Reichenbach JR,Schad LR,Schoenberg SO,Debus J,Kaiser WA

    更新日期:1999-12-01 00:00:00