Breath-hold T2-weighted sequences of the liver: a comparison of four techniques at 1.0 and 1.5 T.

Abstract:

:T2-weighted images are considered the most sensitive for lesion detection at high field; however, long imaging time is problematic. Accordingly, the authors compared four breath-hold T2 or T2* weighted sequences comprising T2*-weighted FLASH, T2*-weighted PSIF, T2-weighted rapid spin echo (RASE), and T2-weighted Turbo-FLASH (Turbo) in 20 different healthy volunteers, 10 at 1.0 T and 10 at 1.5 T with reference to regular T2-weighted spin echo. Images were evaluated quantitatively by liver signal to noise (S/N) and spleen-liver signal difference to noise (SD/N) ratios and qualitatively for presence of artifacts and image quality. Data were evaluated for 1.0 T and 1.5 T separately and combined. In the combined evaluation, T2*-FLASH had good S/N (23.1 + 5.1) but low SD/N (2.9 + 1.7) and suffered from susceptibility artifacts. T2* PSIF had good S/N (28.1 + 10.0) and moderate SD/N (6.0 + 2.4), but occasionally had heterogeneous signal intensity. Flow signal void was an attractive feature. T2 RASE had very low S/N (4.4 + 1.9) and low SD/N (2.3 + 1.1) and suffered from flow artifacts. T2-Turbo had good S/N (24.6 + 8.6) and SD/N (8.9 + 2.5). Flow signal void was present, but small matrix size decreased image quality. The results of our study suggest that T2*-PSIF and T2-Turbo have good S/N and SD/N and fair image quality which may be clinically useful for breath-hold T2-weighted sequences of the liver.

journal_name

Magn Reson Imaging

authors

Simm FC,Semelka RC,Recht M,Deimling M,Lenz G,Laub GA

doi

10.1016/0730-725x(92)90371-6

subject

Has Abstract

pub_date

1992-01-01 00:00:00

pages

41-7

issue

1

eissn

0730-725X

issn

1873-5894

pii

0730-725X(92)90371-6

journal_volume

10

pub_type

杂志文章
  • Towards quantitative evaluation of wall shear stress from 4D flow imaging.

    abstract::Wall shear stress (WSS) is a relevant hemodynamic indicator of the local stress applied on the endothelium surface. More specifically, its spatiotemporal distribution reveals crucial in the evolution of many pathologies such as aneurysm, stenosis, and atherosclerosis. This paper introduces a new solution, called PaLMA...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.08.017

    authors: Levilly S,Castagna M,Idier J,Bonnefoy F,Le Touzé D,Moussaoui S,Paul-Gilloteaux P,Serfaty JM

    更新日期:2020-12-01 00:00:00

  • An intravascular loopless monopole antenna for vessel wall MR imaging at 3.0 T.

    abstract::The purpose of this study was to develop a novel intravascular loopless monopole antenna (ILMA) design specifically for imaging of small vessel walls. The ILMA consisted of an unshielded, low-friction guide wire and a tuning/matching box. The material of the guide wire was nitinol and it was coated with polyurethane. ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.032

    authors: Yuan H,Lv X,Ma X,Zhang R,Fu Y,Yang X,Wang X,Zhang Z,Zhang J,Fang J

    更新日期:2013-01-01 00:00:00

  • Effect of off-frequency sampling in magnetic resonance elastography.

    abstract::In magnetic resonance elastography (MRE), shear waves at a certain frequency are encoded through bipolar gradients that switch polarity at a controlled encoding frequency and are offset in time to capture wave propagation using a controlled sampling frequency. In brain MRE, there is a possibility that the mechanical a...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.09.017

    authors: Johnson CL,Chen DD,Olivero WC,Sutton BP,Georgiadis JG

    更新日期:2012-02-01 00:00:00

  • Astrocytic energy metabolism and glutamate formation--relevance for 13C-NMR spectroscopy and importance of cytosolic/mitochondrial trafficking.

    abstract::Glutamate plays a double role in (13)C-nuclear magnetic resonance (NMR) spectroscopic determination of glucose metabolism in the brain. Bidirectional exchange between initially unlabeled glutamate and labeled α-ketoglutarate, formed from pyruvate via pyruvate dehydrogenase (PDH), indicates the rate of energy metabolis...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.04.013

    authors: Hertz L

    更新日期:2011-12-01 00:00:00

  • In vivo mapping of functional domains and axonal connectivity in cat visual cortex using magnetic resonance imaging.

    abstract::Noninvasive cognitive neuroimaging studies based on functional magnetic resonance imaging (fMRI) are of ever-increasing importance for basic and clinical neurosciences. The explanatory power of fMRI could be greatly expanded, however, if the pattern of the neuronal circuitry underlying functional activation could be m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.08.014

    authors: Kim DS,Kim M,Ronen I,Formisano E,Kim KH,Ugurbil K,Mori S,Goebel R

    更新日期:2003-12-01 00:00:00

  • In vivo MR evaluation of Gd-DTPA conjugated to dextran in normal rabbits.

    abstract::A dextran-Gd-DTPA compound has been recently synthesized utilizing 70,800 Da molecular weight dextran. This polymeric contrast agent for magnetic resonance imaging has been found chemically to be very stable and to demonstrate in vitro improved relaxivities of 1.5 to 2.3 times that of monomeric Gd-DTPA at 100 MHz. Thi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90515-2

    authors: Li KC,Quisling RG,Armitage FE,Richardson D,Mladinich C

    更新日期:1992-01-01 00:00:00

  • AG-013736, a novel inhibitor of VEGF receptor tyrosine kinases, inhibits breast cancer growth and decreases vascular permeability as detected by dynamic contrast-enhanced magnetic resonance imaging.

    abstract::Dynamic contrast-enhanced MRI (DCE-MRI) was used to noninvasively evaluate the effects of AG-03736, a novel inhibitor of vascular endothelial growth factor (VEGF) receptor tyrosine kinases, on tumor microvasculature in a breast cancer model. First, a dose response study was undertaken to determine the responsiveness o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.09.041

    authors: Wilmes LJ,Pallavicini MG,Fleming LM,Gibbs J,Wang D,Li KL,Partridge SC,Henry RG,Shalinsky DR,Hu-Lowe D,Park JW,McShane TM,Lu Y,Brasch RC,Hylton NM

    更新日期:2007-04-01 00:00:00

  • Multicontrast multiecho FLASH MRI for targeting the subthalamic nucleus.

    abstract::The subthalamic nucleus (STN) is one of the most common stimulation targets for treating Parkinson's disease using deep brain stimulation (DBS). This procedure requires precise placement of the stimulating electrode. Common practice of DBS implantation utilizes microelectrode recording to locate the sites with the cor...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.02.006

    authors: Xiao Y,Beriault S,Pike GB,Collins DL

    更新日期:2012-06-01 00:00:00

  • Relationship between cancellous bone induced magnetic field and ultrastructure in a rat ovariectomy model.

    abstract::The site-dependent variations in trabecular bone morphology were studied in the rat tibia by magnitude and phase difference three-dimensional nuclear magnetic resonance microscopy and image processing, and the implications of ovariectomy were evaluated. Specimens excised from the proximal tibial metaphysis in ovariect...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00107-1

    authors: Takahashi M,Wehrli FW,Hwang SN,Wehrli SL

    更新日期:2000-01-01 00:00:00

  • Empirical optimization of ASL data analysis using an ASL data processing toolbox: ASLtbx.

    abstract::Arterial spin labeling (ASL) perfusion fMRI data differ in important respects from the more familiar blood oxygen level-dependent (BOLD) fMRI data and require specific processing strategies. In this paper, we examined several factors that may influence ASL data analysis, including data storage bit resolution, motion c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.07.003

    authors: Wang Z,Aguirre GK,Rao H,Wang J,Fernández-Seara MA,Childress AR,Detre JA

    更新日期:2008-02-01 00:00:00

  • Identification of an optimal threshold for detecting human brown adipose tissue using receiver operating characteristic analysis of IDEAL MRI fat fraction maps.

    abstract:PURPOSE:Lower fat fraction (FF) in brown adipose tissue (BAT) than white adipose tissue (WAT) has been exploited using Dixon-based Magnetic Resonance Imaging (MRI) to differentiate these tissues in rodents, human infants and adults. We aimed to determine whether an optimal FF threshold could be determined to differenti...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.04.013

    authors: Jones TA,Wayte SC,Reddy NL,Adesanya O,Dimitriadis GK,Barber TM,Hutchinson CE

    更新日期:2018-09-01 00:00:00

  • MRI studies of the neurotoxic effects of L-2-chloropropionic acid on rat brain.

    abstract::L-2-Chloropropionic acid (L-CPA) is selectively toxic to rat cerebellar granule cells; necrosis is first observed about 36 hours after administration of L-CPA (750 mg/kg p.o.) becoming more marked by 48 h. Parallel to the onset of cell death an increase in cerebellar water content and sodium concentration has been rep...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00231-4

    authors: Williams RE,Prior M,Bachelard HS,Waterton JC,Checkley D,Lock EA

    更新日期:2001-02-01 00:00:00

  • Non-Gaussian diffusion MRI assessment of brain microstructure in mild cognitive impairment and Alzheimer's disease.

    abstract::We report the first application of a novel diffusion-based MRI method, called diffusional kurtosis imaging (DKI), to investigate changes in brain tissue microstructure in patients with mild cognitive impairment (MCI) and AD and in cognitively intact controls. The subject groups were characterized and compared in terms...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.02.008

    authors: Falangola MF,Jensen JH,Tabesh A,Hu C,Deardorff RL,Babb JS,Ferris S,Helpern JA

    更新日期:2013-07-01 00:00:00

  • Isotropically weighted intravoxel incoherent motion brain imaging at 7T.

    abstract::Perfusion magnetic resonance imaging (MRI) is a promising non-invasive technique providing insights regarding the brain's microvascular architecture in vivo. The scalar perfusion metrics can be used for quantitative diagnostics of various brain abnormalities, in particular, in the stroke cases and tumours. However, co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.11.007

    authors: Maximov II,Vellmer S

    更新日期:2019-04-01 00:00:00

  • Spectroscopic imaging of the brain with phased-array coils at 3.0 T.

    abstract::The goal of this study was to develop and evaluate high-resolution magnetic resonance spectroscopic imaging (MRSI) utilizing the gains in signal-to-noise ratio (SNR) provided by combining higher magnetic field with high-sensitivity phased-array (PA) coils. We investigated the maximum improvement in spatial resolution ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.019

    authors: Xu D,Chen AP,Cunningham C,Osorio JA,Nelson SJ,Vigneron DB

    更新日期:2006-01-01 00:00:00

  • Two-tensor model-based bootstrapping on classified tensor morphologies: estimation of uncertainty in fiber orientation and probabilistic tractography.

    abstract::In this manuscript, fast and clinically feasible model-based bootstrapping algorithms using a geometrically constrained two-tensor diffusion model are employed for estimating uncertainty in fiber orientation. A Monte-Carlo-based tensor morphology voxel classification algorithm is initially applied using single-tensor ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.07.004

    authors: Ratnarajah N,Simmons A,Bertoni M,Hojjatoleslami A

    更新日期:2013-02-01 00:00:00

  • A functionalized superparamagnetic iron oxide colloid as a receptor directed MR contrast agent.

    abstract::We have synthesized a surface functionalized superparamagnetic iron oxide colloid whose clearance from the vascular compartment was inhibited by asialofetuin but not fetuin. Unlike other particulate or colloidal magnetic resonance (MR) contrast agents, the agent of the current communication is not withdrawn from the v...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90143-p

    authors: Josephson L,Groman EV,Menz E,Lewis JM,Bengele H

    更新日期:1990-01-01 00:00:00

  • Sources of functional magnetic resonance imaging signal fluctuations in the human brain at rest: a 7 T study.

    abstract::Signal fluctuations in functional magnetic resonance imaging (fMRI) can result from a number of sources that may have a neuronal, physiologic or instrumental origin. To determine the relative contribution of these sources, we recorded physiological (respiration and cardiac) signals simultaneously with fMRI in human vo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.02.004

    authors: Bianciardi M,Fukunaga M,van Gelderen P,Horovitz SG,de Zwart JA,Shmueli K,Duyn JH

    更新日期:2009-10-01 00:00:00

  • A purpose-built neck coil for black-blood DANTE-prepared carotid artery imaging at 7T.

    abstract::Atherosclerotic plaques in the bifurcation of the carotid arteries can pose a significant health risk due to possible plaque rupture and subsequent stroke. The assessment of plaques, and evaluation of the risk they pose, can be performed with Black-Blood (BB) vessel wall magnetic resonance imaging. However, resolution...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.04.011

    authors: Papoutsis K,Li L,Near J,Payne S,Jezzard P

    更新日期:2017-07-01 00:00:00

  • Usefulness of cervical magnetic resonance imaging for detecting type A acute aortic dissection with acute stroke symptoms.

    abstract::Type A acute aortic dissection (TAAAD) sometimes presents with acute stroke-like symptoms. When intravenous tissue plasminogen activator (IV-tPA) therapy is considered for acute ischemic stroke, TAAAD must be excluded. Painless TAAAD presenting with acute stroke may be easily missed. Two cases of painless TAAAD presen...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.04.021

    authors: Matsumoto H,Yoshida Y,Hirata Y

    更新日期:2016-09-01 00:00:00

  • 1H magnetic resonance imaging and 31P magnetic resonance spectroscopy in experimental filariasis.

    abstract::1H Magnetic resonance imaging and 31P magnetic resonance spectroscopy (MRS) have been carried out in experimental rodent filariasis, i.e., Acanthocheilonema viteae infection in the rodent host, Mastomys coucha. The T2-weighted image of the infected host shows fine hyperintense thread like structures of adult filariid ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00180-x

    authors: Shukla-Dave A,Fatma N,Roy R,Srivastava S,Chatterjee RK,Govindaraju V,Viswanathan AK,Raghunathan P

    更新日期:1997-01-01 00:00:00

  • Dielectric resonances and B(1) field inhomogeneity in UHFMRI: computational analysis and experimental findings.

    abstract::B(1) Field inhomogeneity and the relative effects of dielectric resonances are analyzed within the context of ultra high field MRI. This is accomplished by calculating the electromagnetic fields inside spherical phantoms and within a human head model in the presence and absence of an RF coil. These calculations are th...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00300-9

    authors: Ibrahim TS,Lee R,Abduljalil AM,Baertlein BA,Robitaille PM

    更新日期:2001-02-01 00:00:00

  • Regional variations in MR relaxation of hip joint cartilage in subjects with and without femoralacetabular impingement.

    abstract::The objective of this study was to analyze regional variations of magnetic resonance (MR) relaxation times (T1ρ and T2) in hip joint cartilage of healthy volunteers and subjects with femoral acetabular impingement (FAI). Morphological and quantitative images of the hip joints of 12 healthy volunteers and 9 FAI patient...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.01.009

    authors: Subburaj K,Valentinitsch A,Dillon AB,Joseph GB,Li X,Link TM,Vail TP,Majumdar S

    更新日期:2013-09-01 00:00:00

  • The Langerhans' cell histiocytosis (eosinophilic granuloma) of the cervical spine: a rare diagnosis of cervical pain.

    abstract::We present the case of a 44-year-old man who complained of cervical pain. He was treated with physiotherapy and analgetics. Because of persistent pain, computed tomography (CT) scan and MRI were performed. They revealed an osteolytic destruction of the fourth cervical vertebra. The patient was treated surgically for r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2004.01.006

    authors: Simanski C,Bouillon B,Brockmann M,Tiling T

    更新日期:2004-05-01 00:00:00

  • Measurement of fat fraction in the human thymus by localized NMR and three-point Dixon MRI techniques.

    abstract:PURPOSE:To develop a protocol to non-invasively measure and map fat fraction, fat/(fat+water), as a function of age in the adult thymus for future studies monitoring the effects of interventions aimed at promoting thymic rejuvenation and preservation of immunity in older adults. MATERIALS AND METHODS:Three-dimensional...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.03.016

    authors: Fishbein KW,Makrogiannis SK,Lukas VA,Okine M,Ramachandran R,Ferrucci L,Egan JM,Chia CW,Spencer RG

    更新日期:2018-07-01 00:00:00

  • Dependence of BOLD signal change on tactile stimulus intensity in SI of primates.

    abstract::Recently, we have demonstrated that the fine-digit topography (millimeter sized) previously identified in the primary somatosensory cortex (SI), using electrophysiology and intrinsic signal optical imaging, can also be mapped with submillimeter resolution using blood-oxygenation-level-dependent (BOLD) functional magne...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.05.002

    authors: Zhang N,Gore JC,Chen LM,Avison MJ

    更新日期:2007-07-01 00:00:00

  • Diagnosis of discoid lateral meniscus of the knee on MR imaging.

    abstract::To establish the quantitative MR diagnostic criteria for discoid lateral meniscus, MR imaging of 60 knees with arthroscopically confirmed discoid lateral menisci and 134 knees with semilunar lateral menisci were analyzed. Following four quantitative parameters were measured. (1) Meniscal width (MW): The minimum menisc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00473-3

    authors: Samoto N,Kozuma M,Tokuhisa T,Kobayashi K

    更新日期:2002-01-01 00:00:00

  • Pretibial cyst formation after anterior cruciate ligament reconstruction using auto hamstring grafts: two case reports in a prospective study of 89 cases.

    abstract::Eighty-nine cases after anterior cruciate ligaments (ACL) reconstruction were followed prospectively with magnetic resonance imaging (MRI). The patients were examined using axial and sagittal MRI at least twice during the postoperative evaluation of reconstructed ACL. Two cases of pretibial cyst formation were observe...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00207-1

    authors: Deie M,Sumen Y,Ochi M,Murakami Y,Fujimoto E,Ikuta Y

    更新日期:2000-10-01 00:00:00

  • MR microscopy of micron scale structures.

    abstract::Magnetic resonance (MR) microscopy of up to 1-5-microm resolutions have been reported previously. The tested phantom structures, however, had widths one order of magnitude bigger than the reported resolutions, e.g., spherical beads or capillary tubes of tens-of-micron diameters or wall thicknesses have been imaged. In...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.01.002

    authors: Lee SC,Kim K,Kim J,Yi JH,Lee S,Cheong C

    更新日期:2009-07-01 00:00:00

  • Controlled delivery of Gd-containing liposomes to lymph nodes: surface modification may enhance MRI contrast properties.

    abstract::Surface modification of liposomes containing Gd-diethylenetriaminepentaacetyl-phosphatidylethanolamine (Gd-DTPA-PE) as an amphiphilic paramagnetic label influences their contrast properties as MRI agents. Liposomes with the mean diameter ca. 220 nm and 10% mol content of Gd-DTPA-PE were modified with dextran (molecula...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)00083-f

    authors: Trubetskoy VS,Cannillo JA,Milshtein A,Wolf GL,Torchilin VP

    更新日期:1995-01-01 00:00:00