In vivo mapping of functional domains and axonal connectivity in cat visual cortex using magnetic resonance imaging.

Abstract:

:Noninvasive cognitive neuroimaging studies based on functional magnetic resonance imaging (fMRI) are of ever-increasing importance for basic and clinical neurosciences. The explanatory power of fMRI could be greatly expanded, however, if the pattern of the neuronal circuitry underlying functional activation could be made visible in an equally noninvasive manner. In this study, blood oxygenation level-dependent (BOLD)-based fMRI and diffusion tensor imaging (DTI) were performed in the same cat visual cortex, and the foci of fMRI activation utilized as seeding points for 3D DTI fiber reconstruction algorithms, thus providing the map of the axonal circuitry underlying visual information processing. The methods developed in this study will lay the foundation for in vivo neuroanatomy and the ability for noninvasive longitudinal studies of brain development.

journal_name

Magn Reson Imaging

authors

Kim DS,Kim M,Ronen I,Formisano E,Kim KH,Ugurbil K,Mori S,Goebel R

doi

10.1016/j.mri.2003.08.014

subject

Has Abstract

pub_date

2003-12-01 00:00:00

pages

1131-40

issue

10

eissn

0730-725X

issn

1873-5894

pii

S0730725X03003242

journal_volume

21

pub_type

杂志文章
  • The diagnosis of hippocampal sclerosis: other techniques.

    abstract::Pathologically, hippocampal sclerosis (HS) is characterized by neuronal loss and gliosis affecting particularly the pyramidal neurons of CA1, CA3, and CA4 with relative sparing of the CA2 neurons. This can be identified in vivo with magnetic resonance (MR) imaging techniques that can reveal both morphological and sign...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/0730-725x(95)02016-m

    authors: Jackson GD

    更新日期:1995-01-01 00:00:00

  • Neurophysiological and functional MRI evidence of reorganization of cortical motor areas in cerebral arteriovenous malformation.

    abstract::Functional magnetic resonance imaging (fMRI) research has shown that brain arteriovenous malformations (AVMs) lead to reorganization of cortical motor areas. Since it is known that blood oxygenation level-dependent signal in fMRI may be influenced by the hemodynamic perturbation associated with the presence of the AVM...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.05.029

    authors: Caramia F,Francia A,Mainero C,Tinelli E,Palmieri MG,Colonnese C,Bozzao L,Caramia MD

    更新日期:2009-12-01 00:00:00

  • Analysis of microporosity and setting of reactive powder concrete by proton nuclear relaxation.

    abstract::The proton spin-lattice relaxation measured at several frequencies leads to a resolved distribution of four Tli for reactive powder concrete (RPC). The typical Tli frequency dependences are quantitatively interpreted by a biphasic fast exchange model and a proton nuclear relaxation of hydrated paramagnetic ions at the...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00063-0

    authors: Philippot S,Korb JP,Petit D,Zanni H

    更新日期:1998-06-01 00:00:00

  • 7T CEST MRI: A potential imaging tool for the assessment of tumor grade and cell proliferation in breast cancer.

    abstract:OBJECTIVES:To investigate the feasibility of chemical exchange saturation transfer (CEST) MRI in patients with breast carcinomas and possible correlations between magnetization transfer asymmetry (MTRasym) values and histological features, such as tumor grade and the Ki-67 proliferation index. MATERIALS AND METHODS:Ni...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.03.004

    authors: Zaric O,Farr A,Poblador Rodriguez E,Mlynarik V,Bogner W,Gruber S,Asseryanis E,Singer CF,Trattnig S

    更新日期:2019-06-01 00:00:00

  • MRI studies of the neurotoxic effects of L-2-chloropropionic acid on rat brain.

    abstract::L-2-Chloropropionic acid (L-CPA) is selectively toxic to rat cerebellar granule cells; necrosis is first observed about 36 hours after administration of L-CPA (750 mg/kg p.o.) becoming more marked by 48 h. Parallel to the onset of cell death an increase in cerebellar water content and sodium concentration has been rep...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00231-4

    authors: Williams RE,Prior M,Bachelard HS,Waterton JC,Checkley D,Lock EA

    更新日期:2001-02-01 00:00:00

  • Effect of vasodilator hydralazine on tumor microvascular random flow and blood volume as measured by intravoxel incoherent motion (IVIM) weighted MRI in conjunction with Gd-DTPA-Albumin enhanced MRI.

    abstract::We studied the effect of hydralazine on tumor blood volume fraction and microvascular random flow velocity magnitude by IVIM weighted MRI in conjunction with dynamic Gd-DTPA-Albumin enhanced MRI. Blood volume fraction maps were obtained from the dynamic Gd-DTPA-Albumin enhanced MRI measurements. The average blood volu...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00431-3

    authors: Wang Z,Su MY,Najafi A,Nalcioglu O

    更新日期:2001-10-01 00:00:00

  • Carotid plaque high-resolution MRI at 3 T: evaluation of a new imaging score for symptomatic plaque assessment.

    abstract:PURPOSE:To assess the sensitivity and specificity of intra-plaque hemorrhage (IPH), large lipid-rich necrotic core (LR-NC) and ulceration or cap rupture (UCR) for symptomatic carotid plaque characterization and to evaluate a new imaging score [Hemorrhage, Ulceration or cap rupture, Lipid-rich necrotic Core (HULC) score...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.04.024

    authors: Gury-Paquet L,Millon A,Salami F,Cernicanu A,Scoazec JY,Douek P,Boussel L

    更新日期:2012-12-01 00:00:00

  • Functional magnetic resonance imaging in a stereotactic setup.

    abstract::The localization of critical structures within the brain is important for the planning of therapeutic strategies. Functional MRI is capable to assess functional response of cortical structures to certain stimuli. The authors present two techniques for functional MRI (fMRI) in a stereotactic set-up. The skull of the pa...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)02108-x

    authors: Debus J,Essig M,Schad LR,Wenz F,Baudendistel K,Knopp MV,Engenhart R,Lorenz WJ

    更新日期:1996-01-01 00:00:00

  • Non-Gaussian diffusion MRI assessment of brain microstructure in mild cognitive impairment and Alzheimer's disease.

    abstract::We report the first application of a novel diffusion-based MRI method, called diffusional kurtosis imaging (DKI), to investigate changes in brain tissue microstructure in patients with mild cognitive impairment (MCI) and AD and in cognitively intact controls. The subject groups were characterized and compared in terms...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.02.008

    authors: Falangola MF,Jensen JH,Tabesh A,Hu C,Deardorff RL,Babb JS,Ferris S,Helpern JA

    更新日期:2013-07-01 00:00:00

  • Cardiovascular applications of magnetic resonance imaging.

    abstract::Magnetic resonance imaging (MRI) is a completely noninvasive modality that has shown significant promise for the evaluation of the cardiovascular system. Our imaging technique employed electrocardiographic (ECG) gating, which resulted in well-resolved images of the cardiac structures. Patients and animals with a varie...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(84)90002-x

    authors: McNamara MT,Higgins CB

    更新日期:1984-01-01 00:00:00

  • Pulsed arterial spin labeling perfusion imaging at 3 T: estimating the number of subjects required in common designs of clinical trials.

    abstract::Pulsed arterial spin labeling (PASL) is an increasingly common technique for noninvasively measuring cerebral blood flow (CBF) and has previously been shown to have good repeatability. It is likely to find a place in clinical trials and in particular the investigation of pharmaceutical agents active in the central ner...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.02.030

    authors: Murphy K,Harris AD,Diukova A,Evans CJ,Lythgoe DJ,Zelaya F,Wise RG

    更新日期:2011-12-01 00:00:00

  • Interpretation of restricted diffusion in sandstones with internal field gradients.

    abstract::We report on experiments to characterize internal magnetic field gradients that are caused by magnetic susceptibility differences between the solid phase and the fluids filling the pore space. Our measurements focus on low-field relaxometry of brine and oil in sandstones from various reservoirs around the world. Our r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00287-9

    authors: Appel M,Freeman JJ,Gardner JS,Hirasaki GH,Zhang QG,Shafer JL

    更新日期:2001-04-01 00:00:00

  • A comparison of readout segmented EPI and interleaved EPI in high-resolution diffusion weighted imaging.

    abstract:PURPOSE:To provide a comprehensive understanding of multi-shot EPI diffusion imaging methods by comparing Readout segmented EPI (RS-EPI) and interleaved EPI (iEPI). MATERIALS AND METHODS:RS-EPI and iEPI were compared on the same 3T scanner. A 2D navigator was used for both RS-EPI and iEPI for phase correction. Signal ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.11.011

    authors: Wang Y,Ma X,Zhang Z,Dai E,Jeong HK,Xie B,Yuan C,Guo H

    更新日期:2018-04-01 00:00:00

  • Quantifying and comparing region-of-interest activation patterns in functional brain MR imaging: methodology considerations.

    abstract::The general aims of functional brain magnetic resonance imaging (fMRI) studies are to ascertain which areas of the brain are activated during a specific task, the extent of this activation, whether different groups of subjects demonstrate different patterns of activation, and how these groups behave in different tasks...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00278-6

    authors: Constable RT,Skudlarski P,Mencl E,Pugh KR,Fulbright RK,Lacadie C,Shaywitz SE,Shaywitz BA

    更新日期:1998-04-01 00:00:00

  • Evaluation of preprocessing steps to compensate for magnetic field distortions due to body movements in BOLD fMRI.

    abstract::Blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) is currently the dominant technique for non-invasive investigation of brain functions. One of the challenges with BOLD fMRI, particularly at high fields, is compensation for the effects of spatiotemporally varying magnetic field inho...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.07.005

    authors: Barry RL,Williams JM,Klassen LM,Gallivan JP,Culham JC,Menon RS

    更新日期:2010-02-01 00:00:00

  • Assessment of transplant renal artery stenosis with diffusion-weighted imaging: A preliminary study.

    abstract:OBJECTIVE:To characterize capillary perfusion and tissue diffusion changes in transplant renal artery stenosis (TRAS) with diffusion-weighted imaging (DWI). MATERIALS & METHODS:We retrospectively identified 30 patients with non-contrast enhanced magnetic resonance angiography-proven TRAS. Another 20 kidney transplant ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.05.007

    authors: Fan M,Ni X,Li Y,Chen J,Cheng D,Shi D,He X,Wen J

    更新日期:2019-07-01 00:00:00

  • A CT using longitudinally detected ESR (LODESR-CT) of intraperitoneally injected nitroxide radical in a rat's head.

    abstract::We have developed an in vivo longitudinally detected ESR (LODESR) imaging system operating at 700 MHz based on a loop-gap resonator and a pair of saddle-type pickup coils. A good linear relationship between the LODESR signal intensity and the applied power in a range up to 15.8 W was obtained. The detection of LODESR ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)82763-4

    authors: Yokoyama H,Sato T,Tsuchihashi N,Ogata T,Ohya-Nishiguchi H,Kamada H

    更新日期:1997-01-01 00:00:00

  • Non-contrast enhanced 3D SSFP MRA of the renal allograft vasculature: a comparison between radial linear combination and Cartesian inflow-weighted acquisitions.

    abstract::Renal transplant patients often require imaging to ensure appropriate graft placement, to assess integrity of transplant vessel anastomosis and to evaluate for stenosis that can be a cause of graft failure. Because there is risk for nephrogenic systemic fibrosis in the setting of renal insufficiency, the use of non-co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.10.004

    authors: Bultman EM,Klaers J,Johnson KM,François CJ,Schiebler ML,Reeder SB,Block WF

    更新日期:2014-02-01 00:00:00

  • Test-retest reliability of cerebral blood flow in healthy individuals using arterial spin labeling: Findings from the EMBARC study.

    abstract:INTRODUCTION:Previous investigations of test-retest reliability of cerebral blood flow (CBF) at rest measured with pseudo-continuous Arterial Spin Labeling (pCASL) demonstrated good reliability, but are limited by the use of similar scanner platforms. In the present study we examined test-retest reliability of CBF in r...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.09.004

    authors: Almeida JRC,Greenberg T,Lu H,Chase HW,Fournier JC,Cooper CM,Deckersbach T,Adams P,Carmody T,Fava M,Kurian B,McGrath PJ,McInnis MG,Oquendo MA,Parsey R,Weissman M,Trivedi M,Phillips ML

    更新日期:2018-01-01 00:00:00

  • A flexible 9-channel coil array for fast 3D MR thermometry in MR-guided high-intensity focused ultrasound (HIFU) studies on rabbits at 3 T.

    abstract::Signal-to-noise ratio (SNR) is a critical factor in MR-guided high-intensity focused ultrasound (HIFU) for local heating, which can affect the accuracy of temperature measurement. In order to achieve high SNR and higher temporal resolution, dedicated coil arrays for MR-guided HIFU applications need to be developed. In...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.10.008

    authors: Chen Q,Li Y,Jiang R,Zou C,Tie C,Wen J,Yang X,Zhang X,Liu X,Zheng H

    更新日期:2020-01-01 00:00:00

  • Intramuscular adipose tissue determined by T1-weighted MRI at 3T primarily reflects extramyocellular lipids.

    abstract:PURPOSE:The purpose of this study was to assess relationships between intramuscular adipose tissue (IntraMAT) content determined by MRI and intramyocellular lipids (IMCL) and extramyocellular lipids (EMCL) determined by (1)H magnetic resonance spectroscopy ((1)H MRS) or echo intensity determined by B-mode ultrasonograp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.12.038

    authors: Akima H,Hioki M,Yoshiko A,Koike T,Sakakibara H,Takahashi H,Oshida Y

    更新日期:2016-05-01 00:00:00

  • MR imaging of cervical spine motion with HASTE.

    abstract::The HASTE (half-Fourier acquisition single-shot turbo spin-echo) technique delivers images with T2-weighting in about half a second and could be ideal for fast dynamic studies when T2-weighting is needed. We evaluated cardiac-triggered HASTE to study cervical spine flexion/extension. The cervical spines of ten asympto...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00176-3

    authors: Duerinckx AJ,Yu WD,El-Saden S,Kim D,Wang JC,Sandhu HS

    更新日期:1999-04-01 00:00:00

  • Dynamic contrast-enhanced MRI to assess hepatocellular carcinoma response to Transarterial chemoembolization using LI-RADS criteria: A pilot study.

    abstract:PURPOSE:To identify quantitative dynamic contrast-enhanced (DCE)-MRI perfusion parameters indicating tumor response of hepatocellular carcinoma (HCC) to transarterial chemoembolization (TACE). MATERIALS AND METHODS:This prospective pilot study was approved by our institutional review board; written and informed consen...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.mri.2019.06.017

    authors: Thibodeau-Antonacci A,Petitclerc L,Gilbert G,Bilodeau L,Olivié D,Cerny M,Castel H,Turcotte S,Huet C,Perreault P,Soulez G,Chagnon M,Kadoury S,Tang A

    更新日期:2019-10-01 00:00:00

  • Quantitative longitudinal fluid saturation profiles with a slice-selected CPMG sequence.

    abstract::A technique for obtaining quantitative longitudinal saturation/porosity profiles of rock cores which are longer than the NMR coil has been developed. The slice-selected experiment uses a prefocused pulse in conjunction with a magnetic field gradient for the localization and a CPMG sequence to sample the data. A variet...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91547-4

    authors: Pierens GK,Peyron M,Lucas AJ,Carpenter TA,Hall LD,Potter GF,Stewart RC,Phelps DW

    更新日期:1994-01-01 00:00:00

  • Investigation of molecular order and dynamics in liquid crystals confined in porous media using the dipolar-correlation effect on the stimulated echo.

    abstract::A new application of the stimulated echo pulse sequence is presented that permits the elucidation of molecular order and dynamics in a time scale between about 100 microseconds and the spin-lattice relaxation time. The technique exploits the influence of dipolar coupling on the quotient of the stimulated and primary e...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(96)00172-5

    authors: Grinberg F,Kimmich R,Stapf S

    更新日期:1996-01-01 00:00:00

  • In vivo T1 characterization of genetically induced muscle atrophy.

    abstract::In vivo spin-lattice relaxation times, T1, of water and lipid protons of normal and atrophic muscles were measured, using the spatially resolved spectroscopy (SPARS) sequence, in a genetic avian model of myopathy. These T1 values were compared with those of the hypertrophic muscles. Although the water T1 values of mus...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90550-x

    authors: Misra LK,Narayana PA

    更新日期:1989-05-01 00:00:00

  • Magnetization transfer of water T(2) relaxation components in human brain: implications for T(2)-based segmentation of spectroscopic volumes.

    abstract::Biexponential T(2) relaxation of the localized water signal can be used for segmentation of spectroscopic volumes. To assess the specificity of the components an iterative relaxation measurement of the localized water signal (STEAM, 12 echo times, geometric spacing from 30 ms to 2000 ms) was combined with magnetizatio...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00396-4

    authors: Helms G,Piringer A

    更新日期:2001-07-01 00:00:00

  • High-resolution gadolinium-enhanced 3D MRA of the infrapopliteal arteries. Lessons for improving bolus-chase peripheral MRA.

    abstract::Peripheral magnetic resonance angiography (MRA) is growing in use. However, methods of performing peripheral MRA vary widely and continue to be optimized, especially for improvement in illustration of infrapopliteal arteries. The main purpose of this project was to identify imaging factors that can improve arterial vi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00531-3

    authors: Hood MN,Ho VB,Foo TK,Marcos HB,Hess SL,Choyke PL

    更新日期:2002-09-01 00:00:00

  • Short T2 contrast with three-dimensional ultrashort echo time imaging.

    abstract::There is increasing interest in imaging short T2 species which show little or no signal with conventional magnetic resonance (MR) pulse sequences. In this paper, we describe the use of three-dimensional ultrashort echo time (3D UTE) sequences with TEs down to 8 μs for imaging of these species. Image contrast was gener...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.11.003

    authors: Du J,Bydder M,Takahashi AM,Carl M,Chung CB,Bydder GM

    更新日期:2011-05-01 00:00:00

  • Liposomal Gd-DTPA: effect of encapsulation on enhancement of hepatoma model by MRI.

    abstract::Liposomes entrapping gadolinium-DTPA (Gd-DTPA) were synthesized from 60 mole percent egg phosphatidylcholine (EPC) and 40 mole percent cholesterol or EPC alone entrapping Gd-DTPA in diameters of 100 and 200 nm. Rats bearing Morris hepatoma in their flanks were imaged by MR pre- and post-contrast with free Gd-DTPA and ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(89)90491-8

    authors: Unger EC,MacDougall P,Cullis P,Tilcock C

    更新日期:1989-07-01 00:00:00