Abstract:
PURPOSE:The purpose of this study was to assess relationships between intramuscular adipose tissue (IntraMAT) content determined by MRI and intramyocellular lipids (IMCL) and extramyocellular lipids (EMCL) determined by (1)H magnetic resonance spectroscopy ((1)H MRS) or echo intensity determined by B-mode ultrasonography of human skeletal muscles. METHODS:Thirty young and elderly men and women were included. T1-weighted MRI was taken from the right mid-thigh to measure IntraMAT content of the vastus lateralis (VL) and biceps femoris (BF) using a histogram shape-based thresholding technique. IMCL and EMCL were measured from the VL and BF at the right mid-thigh using (1)H MRS. Ultrasonographic images were taken from the VL and BF of the right mid-thigh to measure echo intensity based on gray-scale level for quantitative analysis. RESULTS:There was a significant correlation between IntraMAT content by MRI and EMCL of the VL and BF (VL, r=0.506, P<0.01; BF, r=0.591, P<0.001) and between echo intensity and EMCL of the VL and BF (VL, r=0.485, P<0.05; BF, r=0.648, P<0.01). IntraMAT content was also significantly correlated with echo intensity of the VL and BF (VL, r=0.404, P<0.05; BF, r=0.493, P<0.01). CONCLUSION:Our study suggests that IntraMAT content determined by T1-weighted MRI at 3T primarily reflects extramyocellular lipids, not intramyocellular lipids, in human skeletal muscles.
journal_name
Magn Reson Imagingjournal_title
Magnetic resonance imagingauthors
Akima H,Hioki M,Yoshiko A,Koike T,Sakakibara H,Takahashi H,Oshida Ydoi
10.1016/j.mri.2015.12.038subject
Has Abstractpub_date
2016-05-01 00:00:00pages
397-403issue
4eissn
0730-725Xissn
1873-5894pii
S0730-725X(15)00342-2journal_volume
34pub_type
杂志文章abstract::Echo planar imaging (EPI) was extended for the acquisition of both, the spin-echo (SE) and the stimulated echo in a stimulated echo sequence after one excitation from thermal equilibrium. The two independent EPI images reflect different states of the transverse magnetization excited and measured almost simultaneously....
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(94)91234-n
更新日期:1994-01-01 00:00:00
abstract::It is often desirable to separate voxels that contain signal from tissue along with measurement noise from those that contain purely measurement noise. Generally, this separation called thresholding utilizes only the magnitude portion of the images. Recently, methods have been developed that utilize both the magnitude...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2009.05.008
更新日期:2009-11-01 00:00:00
abstract::The polysplenia syndrome is the association of multiple spleens, situs inversus, congenital heart disease, and azygous continuation of the inferior vena cava. Magnetic resonance (MR) is a noninvasive imaging modality which can easily confirm the multiplicity of spleens, situs inversus, and identify complex congenital ...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(89)90538-9
更新日期:1989-11-01 00:00:00
abstract:PURPOSE:Although functional magnetic resonance imaging (fMRI) has revealed that spinal cord injury (SCI) causes anomalous changes in task-induced brain activation, its effect during the resting state remains unclear. The aim of this study is to explore the changes of the brain resting-state function in non-human primat...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2014.02.001
更新日期:2014-06-01 00:00:00
abstract:BACKGROUND AND PURPOSE:Slice-encoding metal artifact corrections (SEMAC)-view-angle tilting (VAT) sequences have recently been used in clinical protocols to reduce metal artifacts in MR scans of patients with spinal instrumentation. The objective of this study was to compare the SEMAC-VAT sequence with the conventional...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2018.08.002
更新日期:2018-12-01 00:00:00
abstract::We describe a lesion with the magnetic resonance imaging (MRI) characteristics of a glioblastoma mutiforme and demonstrate how perfusion MRI and proton MR spectroscopic imaging can be used to differentiate necrotizing cerebritis from what appeared to be a high-grade glioma. A 43-year-old woman presented to her physici...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2006.09.028
更新日期:2007-02-01 00:00:00
abstract:PURPOSE:To introduce a simple analytical formula for estimating T2 from a single Double-Echo in Steady-State (DESS) scan. METHODS:Extended Phase Graph (EPG) modeling was used to develop a straightforward linear approximation of the relationship between the two DESS signals, enabling accurate T2 estimation from one DES...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.12.018
更新日期:2017-05-01 00:00:00
abstract::Dynamic contrast-enhanced magnetic resonance imaging (MRI) is widely used for measuring perfusion and blood volume, especially cerebral blood volume (CBV). In case of blood-brain barrier (BBB) disruption, the conventional techniques only partially determine the pharmacokinetic parameters of contrast medium (CM) exchan...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(00)00223-x
更新日期:2000-12-01 00:00:00
abstract:PURPOSE:To evaluate the influence of cholecystectomy on the flow dynamic pattern of bile in the extrahepatic bile duct by using cine-dynamic MRCP with spatially-selective inversion-recovery (IR) pulse non-invasively. MATERIALS AND METHODS:56 patients with cholecystectomy and 48 control subjects without cholecystectomy...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2020.08.016
更新日期:2020-12-01 00:00:00
abstract::Radial acquisitions can suffer from trajectory errors leading to reduced image quality. Here we present a new method of trajectory correction that uses all spokes of a radial acquisition and compare it to an existing method that uses a two-spoke pre-scan calibration. For both methods, estimates of the necessary shifts...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2014.04.006
更新日期:2014-09-01 00:00:00
abstract::Cells labeled by super paramagnetic iron-oxide (SPIO) nanoparticles are more easily seen in gradient echo MR images, but it has not been shown that the amount of nanoparticles or the number of cells can be directly quantified from MR images. This work utilizes a previously developed and improved Complex Image Summatio...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.08.003
更新日期:2017-01-01 00:00:00
abstract:PURPOSE:To describe the patterns of bile distribution in the biliary tree, duodenum, jejunum, and stomach, and to determine the gallbladder ejection fraction (GBEF) by using functional magnetic resonance cholangiography (MRC) with gadolinium-ethoxybenzyl-diethylenetriamine penta-acetic acid (Gd-EOB-DTPA) in healthy vol...
journal_title:Magnetic resonance imaging
pub_type: 临床试验,杂志文章
doi:10.1016/j.mri.2014.01.003
更新日期:2014-05-01 00:00:00
abstract:PURPOSE:To develop a free-running framework for 3D isotropic simultaneous myocardial T1/T2 mapping and cine imaging. METHODS:Continuous data acquisition with 3D golden angle radial trajectory is used in conjunction with T2 preparation of varying echo times and inversion recovery (IR) pulses to enable simultaneous myoc...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2019.08.008
更新日期:2019-11-01 00:00:00
abstract::Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is often used to examine vascular function in malignant tumors and noninvasively monitor drug efficacy of antivascular therapies in clinical studies. However, complex numerical methods used to derive tumor physiological properties from DCE-MRI images can b...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2012.09.007
更新日期:2013-05-01 00:00:00
abstract::Functional magnetic resonance imaging (fMRI) research has shown that brain arteriovenous malformations (AVMs) lead to reorganization of cortical motor areas. Since it is known that blood oxygenation level-dependent signal in fMRI may be influenced by the hemodynamic perturbation associated with the presence of the AVM...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2009.05.029
更新日期:2009-12-01 00:00:00
abstract::Within the magnetic resonance imaging (MRI) community the trend is going to higher and higher magnetic fields, ranging from 1.5 T to 7 T, corresponding to Larmor frequencies of 63.8-298 MHz. Since for high-field MRI the magnetization increases with the applied magnetic field, the signal-to-noise-ratio increases as wel...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2012.06.014
更新日期:2013-02-01 00:00:00
abstract::Dynamic contrast enhanced (DCE) MRI using Tofts' model for estimating vascular permeability is widely accepted, yet inter-tissue differences in bolus arrival time (BAT) are generally ignored. In this work we propose a method, incorporating the BAT in the analysis, demonstrating its applicability and advantages in heal...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2015.12.014
更新日期:2016-05-01 00:00:00
abstract::A four-channel Tic-Tac-Toe (TTT) transmit RF coil was designed and constructed for foot and ankle imaging at 7T MRI. Numerical simulations using an in-house developed FDTD package and experimental analyses using a homogenous phantom show an excellent agreement in terms of B1+ field distribution and s-parameters. Simul...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2017.09.005
更新日期:2018-01-01 00:00:00
abstract:PURPOSE:To establish an optimized sequence design for fast acceleration of arterial spin labeling (ASL)-based time-resolved magnetic resonance angiography (MRA) by acquisition of control and labeled images in the same shot (fast ACTRESS) and a scan time of <1min, for the evaluation of intracranial vessels. MATERIALS A...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2017.07.026
更新日期:2017-11-01 00:00:00
abstract::Twenty-seven patients with soft-tissue tumors were examined with a Picker 0.15-tesla resistive magnet and by computed tomography (CT). In all but one patient, MRI was better than or equal to CT in defining the anatomic extent of the tumor. We could determine whether major vascular structures were engulfed by the tumor...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(85)90398-4
更新日期:1985-01-01 00:00:00
abstract::A regularization strategy is described for generalized autocalibrating partially parallel acquisition (GRAPPA) that allows successful calibration using a small number of autocalibration signals (ACS). The approach requires certain nonlinear relationships between the GRAPPA coefficients to be satisfied, which increases...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2008.05.005
更新日期:2009-01-01 00:00:00
abstract::Gravity drainage characteristics are important to improve our understanding of gas-liquid or liquid-liquid two-phase flow in porous media. Stable or unstable displacement fronts that controlled by the capillary force, viscous force, gravitational force, etc., are relevant features of immiscible two-phase flow. In this...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.03.004
更新日期:2016-09-01 00:00:00
abstract::Dynamic and static gadolinium-diethylenetriaminepentaacetic acid(Gd-DTPA)-enhanced magnetic resonance imaging (MRI) were evaluated as measures of joint inflammation in arthritis, by a comparison with macroscopic and microscopic signs of synovitis. Furthermore, the importance of the size of the evaluated synovial areas...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(98)00008-3
更新日期:1998-09-01 00:00:00
abstract::The goal of this study was to determine whether presurgical metabolite levels measured by 3D MR Spectroscopic Imaging (MRSI) can accurately detect viable cancer within human brain tumor masses. A total of 31 patients (33 exams, 39 pathology correlations) with brain tumors were studied prior to surgical biopsy and/or r...
journal_title:Magnetic resonance imaging
pub_type: 临床试验,杂志文章
doi:10.1016/s0730-725x(01)00225-9
更新日期:2001-01-01 00:00:00
abstract:PURPOSE:To evaluate the correlation between the pancreatic exocrine insufficiency estimated by cine-dynamic MRCP using spatially selective IR pulse and the severity stages (modified Cambridge classification) based on morphological changes of the pancreatic duct in patients with suspected chronic pancreatitis. MATERIAL...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2017.12.007
更新日期:2018-05-01 00:00:00
abstract::This study describes the appearance of Brenner tumors on MR imaging and compares quantitative signal intensity measurements of Brenner tumors with that of other ovarian tumors. A search of pathologic and MR records disclosed patients who had MRIs showing Brenner tumors prior to surgical excision. Patients (21) with ot...
journal_title:Magnetic resonance imaging
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1016/s0730-725x(98)00136-2
更新日期:1998-12-01 00:00:00
abstract:OBJECTIVE:This study aims to evaluate the applicability of using single-shot and multi-shot segmented diffusion-weighted imaging (DWI) techniques to support biopsy target localization in a cohort of targeted MRI-guided prostate biopsy patients. MATERIALS AND METHODS:Single-shot echo-planar diffusion-weighted imaging (...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2016.05.012
更新日期:2016-10-01 00:00:00
abstract::The proton spin-lattice relaxation measured at several frequencies leads to a resolved distribution of four Tli for reactive powder concrete (RPC). The typical Tli frequency dependences are quantitatively interpreted by a biphasic fast exchange model and a proton nuclear relaxation of hydrated paramagnetic ions at the...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/s0730-725x(98)00063-0
更新日期:1998-06-01 00:00:00
abstract::Pellets of HeLa from suspension cultured cells in isotonic medium (300 mosmolar) were introduced into a Bruker CXP100 NMR spectrophotometer at 80 mHz within 5 min of the start of centrifugation. T1 and T2 times were measured within a total elapsed time of 20-25 min at 80 mHz and 37 degrees C, and averaged 1430 msec an...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/0730-725x(90)90101-7
更新日期:1990-01-01 00:00:00
abstract::Magic-angle sample spinning is one of the cornerstones in high-resolution NMR of solid and semisolid materials. The technique enhances spectral resolution by averaging away rank 2 anisotropic spin interactions, thereby producing isotropic-like spectra with resolved chemical shifts and scalar couplings. In principle, i...
journal_title:Magnetic resonance imaging
pub_type: 杂志文章
doi:10.1016/j.mri.2004.11.067
更新日期:2005-02-01 00:00:00