DUSTER: dynamic contrast enhance up-sampled temporal resolution analysis method.

Abstract:

:Dynamic contrast enhanced (DCE) MRI using Tofts' model for estimating vascular permeability is widely accepted, yet inter-tissue differences in bolus arrival time (BAT) are generally ignored. In this work we propose a method, incorporating the BAT in the analysis, demonstrating its applicability and advantages in healthy subjects and patients. A method for DCE Up Sampled TEmporal Resolution (DUSTER) analysis is proposed which includes: baseline T1 map using DESPOT1 analyzed with flip angle (FA) correction; preprocessing; raw-signal-to-T1-to-concentration time curves (CTC) conversion; automatic arterial input function (AIF) extraction at temporal super-resolution; model fitting with model selection while incorporating BAT in the pharmacokinetic (PK) model, and fits contrast agent CTC while using exhaustive search in the BAT dimension in super-resolution. The method was applied to simulated data and to human data from 17 healthy subjects, six patients with glioblastoma, and two patients following stroke. BAT values were compared to time-to-peak (TTP) values extracted from dynamic susceptibility contrast imaging. Results show that the method improved the AIF estimation and allowed extraction of the BAT with a resolution of 0.8 s. In simulations, lower mean relative errors were detected for all PK parameters extracted using DUSTER compared to analysis without BAT correction (vp:5% vs. 20%, Ktrans: 9% vs. 24% and Kep: 8% vs. 17%, respectively), and BAT estimates demonstrated high correlations (r = 0.94, p < 1e− 10) with true values. In real data, high correlations between BAT values were detected when extracted from data acquired with high temporal resolution (2 s) and sub-sampled standard resolution data (6 s) (mean r = 0.85,p < 1e− 10). BAT and TTP values were significantly correlated in the different brain regions in healthy subjects (mean r = 0.72,p = < 1e− 3), as were voxel-wise comparisons in patients (mean r = 0.89, p < 1e− 10). In conclusion, incorporating BAT in DCE analysis improves estimation accuracy for the AIF and the PK parameters while providing an additional clinically important parameter.

journal_name

Magn Reson Imaging

authors

Liberman G,Louzoun Y,Artzi M,Nadav G,Ewing JR,Ben Bashat D

doi

10.1016/j.mri.2015.12.014

subject

Has Abstract

pub_date

2016-05-01 00:00:00

pages

442-50

issue

4

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(15)00309-4

journal_volume

34

pub_type

杂志文章
  • Three-dimensional magnetic resonance spectroscopic imaging of histologically confirmed brain tumors.

    abstract::The goal of this study was to determine whether presurgical metabolite levels measured by 3D MR Spectroscopic Imaging (MRSI) can accurately detect viable cancer within human brain tumor masses. A total of 31 patients (33 exams, 39 pathology correlations) with brain tumors were studied prior to surgical biopsy and/or r...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0730-725x(01)00225-9

    authors: Vigneron D,Bollen A,McDermott M,Wald L,Day M,Moyher-Noworolski S,Henry R,Chang S,Berger M,Dillon W,Nelson S

    更新日期:2001-01-01 00:00:00

  • Cardiac magnetic resonance tissue tracking in right ventricle: Feasibility and normal values.

    abstract:PURPOSE:To investigate right ventricular (RV) strain in patients without identified cardiac pathology using cardiac magnetic resonance tissue tracking (CMR TT). METHODS:A total of 50 consecutive patients with no identified cardiac pathology were analyzed. RV longitudinal and circumferential strain was assessed by CMR ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.01.007

    authors: Truong VT,Safdar KS,Kalra DK,Gao X,Ambach S,Taylor MD,Moore R,Taylor RJ,Germann J,Toro-Salazar O,Jefferies JL,Bartone C,Raman SV,Ngo T,Mazur W

    更新日期:2017-05-01 00:00:00

  • Correction of partial volume inaccuracies in quantitative phase contrast MR angiography.

    abstract::The phase difference method of phase contrast MR angiography provides a means of measuring the average velocity in each voxel of an MR scan. When static tissue is present in a voxel containing flow, the measured velocity is not the average velocity of the flow alone, but is lower due to the partial volume effect of th...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(94)91245-r

    authors: Hamilton CA

    更新日期:1994-01-01 00:00:00

  • Dynamic contrast-enhanced MRI to assess hepatocellular carcinoma response to Transarterial chemoembolization using LI-RADS criteria: A pilot study.

    abstract:PURPOSE:To identify quantitative dynamic contrast-enhanced (DCE)-MRI perfusion parameters indicating tumor response of hepatocellular carcinoma (HCC) to transarterial chemoembolization (TACE). MATERIALS AND METHODS:This prospective pilot study was approved by our institutional review board; written and informed consen...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.mri.2019.06.017

    authors: Thibodeau-Antonacci A,Petitclerc L,Gilbert G,Bilodeau L,Olivié D,Cerny M,Castel H,Turcotte S,Huet C,Perreault P,Soulez G,Chagnon M,Kadoury S,Tang A

    更新日期:2019-10-01 00:00:00

  • Bilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain.

    abstract::Deep brain stimulation (DBS) is used increasingly in the field of movement disorders. The implanted electrodes create not only a prior risk to patient safety during MRI, but also a unique opportunity in the collection of functional MRI data conditioned by direct neural stimulation. We evaluated MRI-related heating for...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.02.007

    authors: Bhidayasiri R,Bronstein JM,Sinha S,Krahl SE,Ahn S,Behnke EJ,Cohen MS,Frysinger R,Shellock FG

    更新日期:2005-05-01 00:00:00

  • The use of power images to perform quantitative analysis on low SNR MR images.

    abstract::Zero-mean noise introduced into quadrature detected MRI signals is generally rectified by the reconstruction algorithm to give a nonzero background intensity in the displayed image. In low signal-to-noise ratio (SNR) images, this background will inflate region of interest (ROI) signal measurements, leading to improper...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90225-3

    authors: Miller AJ,Joseph PM

    更新日期:1993-01-01 00:00:00

  • 4D MR phase and magnitude segmentations with GPU parallel computing.

    abstract::The increasing size and number of data sets of large four dimensional (three spatial, one temporal) magnetic resonance (MR) cardiac images necessitates efficient segmentation algorithms. Analysis of phase-contrast MR images yields cardiac flow information which can be manipulated to produce accurate segmentations of t...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.08.019

    authors: Bergen RV,Lin HY,Alexander ME,Bidinosti CP

    更新日期:2015-01-01 00:00:00

  • Transdermal water mobility in the presence of electrical fields using MR microscopy.

    abstract::Magnetic resonance microscopy of skin from hairless rats under the influence of electrical fields was conducted for two cases: 1) low voltage constant electrical fields and 2) high-voltage short pulse, electrical fields. Under conditions of the low voltage and low current iontophoresis, i.e., 0 to 20 V, and 0 to 0.5 m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00067-3

    authors: Caban JB,Moerland TS,Gibbs SJ,McFadden L,Locke BR

    更新日期:1999-10-01 00:00:00

  • Initial clinical evaluation of gadolinium DTPA for contrast-enhanced magnetic resonance imaging.

    abstract::Gadolinium DTPA was evaluated as an intravenous contrast agent for magnetic resonance imaging in 15 patients with primary or secondary intracranial neoplastic disease. T1 and T2 weighted images were obtained prior to contrast administration. T1 weighted spin echo 35/800 (TE/TR) images were utilized to detect enhanceme...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(85)90006-2

    authors: Runge VM,Schoerner W,Niendorf HP,Laniado M,Koehler D,Claussen C,Felix R,James AE Jr

    更新日期:1985-01-01 00:00:00

  • Comparison of dynamic contrast-enhanced magnetic resonance imaging and contrast-enhanced ultrasound for evaluation of the effects of sorafenib in a rat model of hepatocellular carcinoma.

    abstract:OBJECTIVES:To compare the accuracy of contrast-enhanced ultrasound (CEUS) and Dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) for the assessment of changes in tissue vascularization as result of sorafenib treatment in a rat model of hepatocellular carcinoma (HCC). METHODS:Male Buffalo rats with orthot...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.11.012

    authors: Muñoz NM,Minhaj AA,Maldonado KL,Kingsley CV,Cortes AC,Taghavi H,Polak U,Mitchell JM,Ensor JE,Bankson JA,Rashid A,Avritscher R

    更新日期:2019-04-01 00:00:00

  • Chemical exchange saturation transfer MR imaging of articular cartilage glycosaminoglycans at 3 T: Accuracy of B0 Field Inhomogeneity corrections with gradient echo method.

    abstract::Glycosaminoglycan Chemical Exchange Saturation Transfer (gagCEST) is an important molecular MRI methodology developed to assess changes in cartilage GAG concentrations. The correction for B0 field inhomogeneity is technically crucial in gagCEST imaging. This study evaluates the accuracy of the B0 estimation determined...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.07.009

    authors: Wei W,Jia G,Flanigan D,Zhou J,Knopp MV

    更新日期:2014-01-01 00:00:00

  • Skeletal muscle lymphoma: MRI evaluation.

    abstract::The magnetic resonance imaging (MRI) features of two cases of malignant lymphoproliferative disease involving skeletal muscle are presented. In both cases involved muscles were quantitatively and subjectively hypointense to fat on T1-weighted spin echo images, hypointense or isointense on T2-weighted spin echo images,...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90522-2

    authors: Metzler JP,Fleckenstein JL,Vuitch F,Frenkel EP

    更新日期:1992-01-01 00:00:00

  • Whole lesion histogram analysis of meningiomas derived from ADC values. Correlation with several cellularity parameters, proliferation index KI 67, nucleic content, and membrane permeability.

    abstract:PURPOSE:To analyze several histopathological features and their possible correlations with whole lesion histogram analysis derived from ADC maps in meningioma. MATERIALS AND METHODS:The retrospective study involved 36 patients with primary meningiomas. For every tumor, the following histogram analysis parameters of ap...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.05.009

    authors: Surov A,Hamerla G,Meyer HJ,Winter K,Schob S,Fiedler E

    更新日期:2018-09-01 00:00:00

  • Factors affecting nitroxide reduction in ascorbate solution and tissue homogenates.

    abstract::Because of their paramagnetic properties, nitroxides are potentially useful as contrast agents in magnetic resonance imaging (MRI). They are reduced in vivo to their corresponding hydroxylamines which are nonparamagnetic and have no contrast enhancing property. Nitroxides with high resistance to reduction would be adv...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(85)90012-8

    authors: Couet WR,Brasch RC,Sosnovsky G,Tozer TN

    更新日期:1985-01-01 00:00:00

  • Pretibial cyst formation after anterior cruciate ligament reconstruction using auto hamstring grafts: two case reports in a prospective study of 89 cases.

    abstract::Eighty-nine cases after anterior cruciate ligaments (ACL) reconstruction were followed prospectively with magnetic resonance imaging (MRI). The patients were examined using axial and sagittal MRI at least twice during the postoperative evaluation of reconstructed ACL. Two cases of pretibial cyst formation were observe...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00207-1

    authors: Deie M,Sumen Y,Ochi M,Murakami Y,Fujimoto E,Ikuta Y

    更新日期:2000-10-01 00:00:00

  • Acoustic-integrated dynamic MR imaging for a patient with obstructive sleep apnea.

    abstract::Obstructive sleep apnea syndrome (OSAS) is caused by multi-level upper airway obstruction. Anatomic changes at the sites of obstruction may modify the physical or acoustic properties of snores. The surgical success of OSA depends upon precise localization of obstructed levels. We present a case of OSAS who received si...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.08.004

    authors: Chen YJ,Shih TT,Chang YC,Hsu YC,Huon LK,Lo MT,Pham VT,Lin C,Wang PC

    更新日期:2015-12-01 00:00:00

  • A functionalized superparamagnetic iron oxide colloid as a receptor directed MR contrast agent.

    abstract::We have synthesized a surface functionalized superparamagnetic iron oxide colloid whose clearance from the vascular compartment was inhibited by asialofetuin but not fetuin. Unlike other particulate or colloidal magnetic resonance (MR) contrast agents, the agent of the current communication is not withdrawn from the v...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(90)90143-p

    authors: Josephson L,Groman EV,Menz E,Lewis JM,Bengele H

    更新日期:1990-01-01 00:00:00

  • Optimized 3D bright blood MRI of aortic plaque at 3 T.

    abstract:PURPOSE:To evaluate the feasibility of an optimized bright blood MRI protocol at 3 T in combination with contrast agent administration for the detection and characterization of aortic high-risk plaques for the improved workup of acute stroke patients. MATERIALS AND METHODS:ECG synchronized T1-weighted 3D gradient echo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.08.010

    authors: Markl M,Dudler P,Fydrychowicz A,Strecker C,Weiller C,Hennig J,Harloff A

    更新日期:2008-04-01 00:00:00

  • Deep neural network inspired by iterative shrinkage-thresholding algorithm with data consistency (NISTAD) for fast Undersampled MRI reconstruction.

    abstract::With the aim of developing a fast algorithm for high-quality MRI reconstruction from undersampled k-space data, we propose a novel deep neural Network, which is inspired by Iterative Shrinkage Thresholding Algorithm with Data consistency (NISTAD). NISTAD consists of three consecutive blocks: an encoding block, which m...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.04.016

    authors: Qiu W,Li D,Jin X,Liu F,Sun B

    更新日期:2020-07-01 00:00:00

  • Computerized MRS voxel registration and partial volume effects in single voxel 1H-MRS.

    abstract::Partial volume effects in proton magnetic resonance spectroscopy in the brain have been studied previously in terms of proper water concentration calculations, but there is a lack of disclosure in terms of voxel placement techniques that would affect the calculations. The purpose of this study is to facilitate a fully...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.04.001

    authors: Lee H,Caparelli E,Li H,Mandal A,Smith SD,Zhang S,Bilfinger TV,Benveniste H

    更新日期:2013-09-01 00:00:00

  • Simultaneous imaging of locus coeruleus and substantia nigra with a quantitative neuromelanin MRI approach.

    abstract::Quantitative MRI of neuromelanin (NM) containing structures (referred to as NM-MRI) in the brainstem, namely the locus coeruleus (LC) and substantia nigra (SN), may assist with the early detection of Parkinson's disease (PD) and Alzheimer's disease (AD) as well as differential diagnosis in the early disease stages. In...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.07.003

    authors: Chen X,Huddleston DE,Langley J,Ahn S,Barnum CJ,Factor SA,Levey AI,Hu X

    更新日期:2014-12-01 00:00:00

  • Validation of estimated 3D temperature maps during hepatic cryo surgery.

    abstract::A simple model for estimating temperature distribution within the frozen region during cryo ablation was tested for accuracy. Freezing experiments were conducted in both ex vivo and in vivo porcine livers. Temperature was measured during freezing using a fiber-optic temperature sensor. Three-dimensional MR images were...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00389-7

    authors: Samset E,Mala T,Edwin B,Gladhaug I,Søreide O,Fosse E

    更新日期:2001-06-01 00:00:00

  • Non-contrast enhanced 3D SSFP MRA of the renal allograft vasculature: a comparison between radial linear combination and Cartesian inflow-weighted acquisitions.

    abstract::Renal transplant patients often require imaging to ensure appropriate graft placement, to assess integrity of transplant vessel anastomosis and to evaluate for stenosis that can be a cause of graft failure. Because there is risk for nephrogenic systemic fibrosis in the setting of renal insufficiency, the use of non-co...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.10.004

    authors: Bultman EM,Klaers J,Johnson KM,François CJ,Schiebler ML,Reeder SB,Block WF

    更新日期:2014-02-01 00:00:00

  • Fat ViP MRI: Virtual Phantom Magnetic Resonance Imaging of water-fat systems.

    abstract:OBJECT:Virtual Phantom Magnetic Resonance Imaging (ViP MRI) is a method to generate reference signals on MR images, using external radiofrequency (RF) signals. The aim of this study was to assess the feasibility of ViP MRI to generate complex-data images of phantoms mimicking water-fat systems. MATERIALS AND METHODS:V...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.12.002

    authors: Salvati R,Hitti E,Bellanger JJ,Saint-Jalmes H,Gambarota G

    更新日期:2016-06-01 00:00:00

  • Voxelwise analysis of diffusion MRI of cervical spinal cord using tract-based spatial statistics.

    abstract::Robust voxelwise analysis using tract-based spatial statistics (TBSS) together with permutation statistical method is standardly used in analyzing diffusion tensor imaging (DTI) of brain. A similar analytical method could be useful when studying DTI of cervical spinal cord. Based on anatomical data of sixty-four healt...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.07.008

    authors: Dostál M,Keřkovský M,Staffa E,Bednařík J,Šprláková-Puková A,Mechl M

    更新日期:2020-11-01 00:00:00

  • Off-resonance binomial preparatory pulse technique for high sensitivity MRI of H2O17.

    abstract::H2O17 is a freely diffusible tracer and naturally occurring isotope of O16 detectable by MRI and has been shown to be useful for assessing cerebral perfusion in animal studies using direct and indirect MR detection techniques. However, earlier MR techniques are either not sensitive to changes in small concentrations o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2003.09.005

    authors: Sood R

    更新日期:2004-02-01 00:00:00

  • The effects of respiratory CO2 fluctuations in the resting-state BOLD signal differ between eyes open and eyes closed.

    abstract::Resting fluctuations in arterial CO2 (a cerebral vasodilator) are believed to be an important source of low-frequency blood oxygenation level dependent (BOLD) signal fluctuations. In this study we focus on the two commonly used resting-states in functional magnetic resonance imaging experiments, eyes open and eyes clo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.06.013

    authors: Peng T,Niazy R,Payne SJ,Wise RG

    更新日期:2013-04-01 00:00:00

  • Noise estimation for the velocity in MRI phase-contrast.

    abstract::The purpose of this study is to estimate the precision or statistical variability of the velocity measurements computed from MRI phase-contrast. From the analytical probability density function (PDF) of the phase in the signal we obtain the PDF of the velocity by means of an auto-convolution. This PDF allows the estim...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.08.028

    authors: Irarrazaval P,Dehghan Firoozabadi A,Uribe S,Tejos C,Sing-Long C

    更新日期:2019-11-01 00:00:00

  • Quantitative 1H MRS in the evaluation of mesial temporal lobe epilepsy in vivo.

    abstract::Hippocampal metabolite concentrations were determined by localized in vivo proton magnetic resonance spectroscopy (1H MRS) in eleven patients suffering from refractory mesial temporal lobe epilepsy (MTLE), as well as in eleven age-matched healthy volunteers, and compared with patient history, postoperative outcome and...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00123-4

    authors: Duc CO,Trabesinger AH,Weber OM,Meier D,Walder M,Wieser HG,Boesiger P

    更新日期:1998-10-01 00:00:00

  • A method for imaging of chemical shift or magnetic field distributions.

    abstract::A phase encoding method for imaging of chemical shift or magnetic field distributions is described. The method utilizes the spin-echo principle and the time period between signal collection and excitation is constant but the time period between excitation and the 180 degrees pulse is varied by constant steps. The meth...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(85)90253-x

    authors: Sepponen RE

    更新日期:1985-01-01 00:00:00