Bilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain.

Abstract:

:Deep brain stimulation (DBS) is used increasingly in the field of movement disorders. The implanted electrodes create not only a prior risk to patient safety during MRI, but also a unique opportunity in the collection of functional MRI data conditioned by direct neural stimulation. We evaluated MRI-related heating for bilateral neurostimulation systems used for DBS with an emphasis on assessing clinically relevant imaging parameters. Magnetic resonance imaging was performed using transmit body radiofrequency (RF) coil and receive-only head RF coil at various specific absorption rates (SARs) of RF power. In vitro testing was performed using a gel-filled phantom with temperatures recorded at the electrode tips. Each DBS electrode was positioned with a single extension loop around each pulse generator and a single loop at the "head" end of the phantom. Various pulse sequences were used for MRI including fast spin-echo, echo-planar imaging, magnetization transfer contrast and gradient-echo techniques. The MRI sequences had calculated whole-body averaged SARs and local head SARs ranging from 0.1 to 1.6 W/kg and 0.1 to 3.2 W/kg, respectively. Temperature elevations of less than 1.0 degrees C were found with the fast spin-echo, magnetization transfer contrast, gradient-echo and echo-planar clinical imaging sequences. Using the highest SAR levels, whole-body averaged, 1.6 W/kg, local exposed-body, 3.2 W/kg, and local head, 2.9 W/kg, the temperature increase was 2.1 degrees C. These results showed that temperature elevations associated with clinical sequences were within an acceptable physiologically safe range for the MR conditions used in this evaluation, especially for the use of relatively low SAR levels. Notably, these findings are highly specific to the neurostimulation systems, device positioning technique, MR system and imaging conditions used in this investigation.

journal_name

Magn Reson Imaging

authors

Bhidayasiri R,Bronstein JM,Sinha S,Krahl SE,Ahn S,Behnke EJ,Cohen MS,Frysinger R,Shellock FG

doi

10.1016/j.mri.2005.02.007

subject

Has Abstract

pub_date

2005-05-01 00:00:00

pages

549-55

issue

4

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(05)00142-6

journal_volume

23

pub_type

杂志文章
  • Assessment of extravascular extracellular space fraction in human melanoma xenografts by DCE-MRI and kinetic modeling.

    abstract::Tumor aggressiveness and response to therapy are influenced by the extravascular extracellular space fraction (EESF) of the malignant tissue. The EESF may, therefore, be an important prognostic parameter for cancer patients. The aim of this study was to investigate whether gadopentetate dimeglumine (Gd-DTPA)-based dyn...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.06.003

    authors: Benjaminsen IC,Brurberg KG,Ruud EB,Rofstad EK

    更新日期:2008-02-01 00:00:00

  • Dixon-based fat-free MR-angiography compared to first pass and steady-state high-resolution MR-angiography using a blood pool contrast agent.

    abstract:INTRODUCTION:Compared to standard arterial-only first-pass MR-angiography (FPMRA), imaging during the equilibrium phase of a blood pool contrast agent (steady state) has been shown to provide higher image quality and better stenosis grading. Homogenous Dixon fat-suppression promises to increase contrast by suppression ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.07.005

    authors: Homsi R,Gieseke J,Kukuk GM,Träber F,Willinek WA,Schild HH,Hadizadeh DR

    更新日期:2015-11-01 00:00:00

  • Optimal real-time estimation in diffusion tensor imaging.

    abstract::Diffusion tensor imaging (DTI) constitutes the most used paradigm among the diffusion-weighted magnetic resonance imaging (DW-MRI) techniques due to its simplicity and application potential. Recently, real-time estimation in DW-MRI has deserved special attention, with several proposals aiming at the estimation of mean...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.12.001

    authors: Casaseca-de-la-Higuera P,Tristán-Vega A,Aja-Fernández S,Alberola-López C,Westin CF,San José Estépar R

    更新日期:2012-05-01 00:00:00

  • Comparison of dynamic contrast-enhanced magnetic resonance imaging and contrast-enhanced ultrasound for evaluation of the effects of sorafenib in a rat model of hepatocellular carcinoma.

    abstract:OBJECTIVES:To compare the accuracy of contrast-enhanced ultrasound (CEUS) and Dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) for the assessment of changes in tissue vascularization as result of sorafenib treatment in a rat model of hepatocellular carcinoma (HCC). METHODS:Male Buffalo rats with orthot...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.11.012

    authors: Muñoz NM,Minhaj AA,Maldonado KL,Kingsley CV,Cortes AC,Taghavi H,Polak U,Mitchell JM,Ensor JE,Bankson JA,Rashid A,Avritscher R

    更新日期:2019-04-01 00:00:00

  • Sources of functional magnetic resonance imaging signal fluctuations in the human brain at rest: a 7 T study.

    abstract::Signal fluctuations in functional magnetic resonance imaging (fMRI) can result from a number of sources that may have a neuronal, physiologic or instrumental origin. To determine the relative contribution of these sources, we recorded physiological (respiration and cardiac) signals simultaneously with fMRI in human vo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.02.004

    authors: Bianciardi M,Fukunaga M,van Gelderen P,Horovitz SG,de Zwart JA,Shmueli K,Duyn JH

    更新日期:2009-10-01 00:00:00

  • Magnetic resonance imaging of soft-tissue tumors: comparison with computed tomography.

    abstract::Twenty-seven patients with soft-tissue tumors were examined with a Picker 0.15-tesla resistive magnet and by computed tomography (CT). In all but one patient, MRI was better than or equal to CT in defining the anatomic extent of the tumor. We could determine whether major vascular structures were engulfed by the tumor...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(85)90398-4

    authors: Weekes RG,Berquist TH,McLeod RA,Zimmer WD

    更新日期:1985-01-01 00:00:00

  • Correlations and dissociations between BOLD signal and P300 amplitude in an auditory oddball task: a parametric approach to combining fMRI and ERP.

    abstract::A parametric method is proposed to examine the relationship between neuronal activity, measured with event related potentials (ERPs), and the hemodynamic response, observed with functional magnetic resonance imaging (fMRI), during an auditory oddball paradigm. After verifying that the amplitude of the evoked response ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00496-4

    authors: Horovitz SG,Skudlarski P,Gore JC

    更新日期:2002-05-01 00:00:00

  • A visualization study on two-phase gravity drainage in porous media by using magnetic resonance imaging.

    abstract::Gravity drainage characteristics are important to improve our understanding of gas-liquid or liquid-liquid two-phase flow in porous media. Stable or unstable displacement fronts that controlled by the capillary force, viscous force, gravitational force, etc., are relevant features of immiscible two-phase flow. In this...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.03.004

    authors: Teng Y,Liu Y,Jiang L,Song Y,Zhao J,Zhang Y,Wang D

    更新日期:2016-09-01 00:00:00

  • Idiopathic dilatation of the pulmonary artery: report of four cases.

    abstract::Idiopathic dilatation of the pulmonary artery (IDPA) is a rare congenital disease which is usually detected fortuitously on chest x-ray, thus radiologists must be aware of this clinical entity. This report describes four cases to which Magnetic Resonance Imaging (MRI) played a major role in diagnosing IDPA and in dete...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00013-2

    authors: Ugolini P,Mousseaux E,Sadou Y,Sidi D,Mercier LA,Paquet E,Gaux JC

    更新日期:1999-07-01 00:00:00

  • Magnetic resonance T2* measurements of the normal human lung in vivo with ultra-short echo times.

    abstract::The objective of this study was to measure T2* values of the normal human lung in vivo during breathhold using a rapid gradient-echo sequence with ultra-short echo times (TE). A sagittal slice of the right lung was imaged in six volunteers with various TE ranging from 0.5 ms to 5 ms using a clinical 1.5 Tesla MR scann...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00047-8

    authors: Stock KW,Chen Q,Hatabu H,Edelman RR

    更新日期:1999-09-01 00:00:00

  • Active intrahepatic gadolinium extravasation following TIPS.

    abstract::A 31-year-old male patient had a transjugular intrahepatic portal systemic shunt (TIPS) placed for acute Budd-Chiari syndrome secondary to paroxysmal nocturnal hemoglobinuria (PNH). Post-procedure, he was anticoagulated for his underlying paroxysmal nocturnal hemoglobinuria. After 11 days, he complained of upper abdom...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00081-2

    authors: Hasegawa S,Eisenberg LB,Semelka RC

    更新日期:1998-09-01 00:00:00

  • Diagnosis of suspicious breast lesions using an empirical mathematical model for dynamic contrast-enhanced MRI.

    abstract::The purpose of this study was to test whether an empirical mathematical model (EMM) of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) can distinguish between benign and malignant breast lesions. A modified clinical protocol was used to improve the sampling of contrast medium uptake and washout. T(1)-we...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2006.10.011

    authors: Fan X,Medved M,Karczmar GS,Yang C,Foxley S,Arkani S,Recant W,Zamora MA,Abe H,Newstead GM

    更新日期:2007-06-01 00:00:00

  • In-situ visual observation for the formation and dissociation of methane hydrates in porous media by magnetic resonance imaging.

    abstract::In this work, magnetic resonance imaging (MRI) was employed to observe the in-situ formation and dissociation of methane hydrates in porous media. Methane hydrate was formed in a high-pressure cell with controlled temperature, and then the hydrate was dissociated by thermal injection. The process was photographed by t...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.12.010

    authors: Zhao J,Lv Q,Li Y,Yang M,Liu W,Yao L,Wang S,Zhang Y,Song Y

    更新日期:2015-05-01 00:00:00

  • Resolution and uncertainty of Laplace inversion spectrum.

    abstract::Laplace inversion has been widely used in analyzing nuclear magnetic resonance data to obtain a spectrum of decay time constant, such as the T(2) spectrum. However, due to the ill-conditioned nature of such inversion, it is difficult to determine the reliability and error of the resulting spectrum. This article descri...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2006.11.023

    authors: Song YQ

    更新日期:2007-05-01 00:00:00

  • The relaxivity of Gd-EOB-DTPA and Gd-DTPA in liver and kidney of the Wistar rat.

    abstract::The NMR relaxivities of Gd-EOB-DTPA and Gd-DTPA were determined in the kidney and liver of intact male Wistar rats immediately following sacrifice and in vitro in solutions and gels, at 1.5 T using a clinical MR scanner, T1 and T2 values of tissue samples were derived from spin-echo image sequences. Tissue gadolinium ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02097-d

    authors: Shuter B,Tofts PS,Wang SC,Pope JM

    更新日期:1996-01-01 00:00:00

  • Probe efficiency improvement with remote and transmission line tuning and matching.

    abstract::In certain nuclear magnetic resonance (NMR) applications in which accessibility to the gantry is limited, performing optimal tuning and matching represents a major problem. Here, we discuss a method of tuning NMR probe circuits and matching their impedances which uses cables with different impedance values. This simpl...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00051-x

    authors: Villa P,Vaquero JJ,Chesnick S,Ruiz-Cabello J

    更新日期:1999-09-01 00:00:00

  • Intravoxel incoherent imaging of renal fibrosis induced in a murine model of unilateral ureteral obstruction.

    abstract:PURPOSE:To evaluate non-invasive imaging biomarkers for assessing renal fibrosis. DWI is used to assess renal function; intravoxel incoherent motion (IVIM) provides additional measures of perfusion-related diffusion (D*, blood flow; f, perfusion fraction). We aim to determine if reduced ADC seen in renal fibrosis is at...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.07.012

    authors: Hennedige T,Koh TS,Hartono S,Yan YY,Song IC,Zheng L,Lee WS,Rumpel H,Martarello L,Khoo JB,Koh DM,Chuang KH,Thng CH

    更新日期:2015-12-01 00:00:00

  • Dynamic contrast-enhanced 3D breath hold MRA using a multiple variable orientation slab acquisition.

    abstract::With the conventional 3D MR angiographic sequences, it is difficult to prescribe multiple phases in different orientations, though multiple phases may be prescribed in the same orientation as the initial scan. Magnetic resonance angiography (MRA) was performed in which three slabs were prescribed in different orientat...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(99)00003-x

    authors: Shetty AN,Bis KG

    更新日期:1999-07-01 00:00:00

  • Quantifying the dynamic density driven convection in high permeability packed beds.

    abstract::The density driven convection phenomenon is expected to have a significant and positive role in CO2 geological storage capacity and safety. The onset and development of density-driven convective on the core scale is critical to understand the mass transfer mechanism. In this paper, laboratory experiments were conducte...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.03.004

    authors: Teng Y,Jiang L,Fan Y,Liu Y,Wang D,Abudula A,Song Y

    更新日期:2017-06-01 00:00:00

  • A preliminary study of blood-oxygen-level-dependent MRI in patients with chronic kidney disease.

    abstract:BACKGROUND:Blood-oxygen-level-dependent (BOLD) magnetic resonance imaging (MRI) can provide regional measurements of oxygen content using deoxyhemoglobin paramagnetic characteristics. The apparent relaxation rate or R2*(=1/T2*) can be determined from the slope of log (intensity) versus echo time and is directly proport...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.10.003

    authors: Xin-Long P,Jing-Xia X,Jian-Yu L,Song W,Xin-Kui T

    更新日期:2012-04-01 00:00:00

  • A fast spin echo two-point Dixon technique and its combination with sensitivity encoding for efficient T2-weighted imaging.

    abstract::A fast spin echo two-point Dixon (fast 2PD) technique was developed for efficient T2-weighted imaging with uniform water and fat separation. The technique acquires two interleaved fast spin echo images with water and fat in-phase and 180 degrees out-of-phase, respectively, and generates automatically separate water an...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.10.005

    authors: Ma J,Son JB,Bankson JA,Stafford RJ,Choi H,Ragan D

    更新日期:2005-12-01 00:00:00

  • Gadolinium toxicity: Iron and ferroportin as central targets.

    abstract::Gadolinium-based magnetic resonance (MR) contrast agents (GBCM) causes a devastating systemic fibrosing illness, nephrogenic systemic fibrosis (NSF), in patients with reduced kidney function. GBCM targets iron-recycling CD163- and ferroportin-expressing macrophages to release labile iron that mediates gadolinium toxic...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2016.08.016

    authors: Swaminathan S

    更新日期:2016-12-01 00:00:00

  • Early assessment of breast cancer response to neoadjuvant chemotherapy by semi-quantitative analysis of high-temporal resolution DCE-MRI: preliminary results.

    abstract:PURPOSE:To evaluate whether semi-quantitative analysis of high temporal resolution dynamic contrast-enhanced MRI (DCE-MRI) acquired early in treatment can predict the response of locally advanced breast cancer (LABC) to neoadjuvant chemotherapy (NAC). MATERIALS AND METHODS:As part of an IRB-approved prospective study,...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.mri.2013.07.002

    authors: Abramson RG,Li X,Hoyt TL,Su PF,Arlinghaus LR,Wilson KJ,Abramson VG,Chakravarthy AB,Yankeelov TE

    更新日期:2013-11-01 00:00:00

  • Voxelwise analysis of diffusion MRI of cervical spinal cord using tract-based spatial statistics.

    abstract::Robust voxelwise analysis using tract-based spatial statistics (TBSS) together with permutation statistical method is standardly used in analyzing diffusion tensor imaging (DTI) of brain. A similar analytical method could be useful when studying DTI of cervical spinal cord. Based on anatomical data of sixty-four healt...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.07.008

    authors: Dostál M,Keřkovský M,Staffa E,Bednařík J,Šprláková-Puková A,Mechl M

    更新日期:2020-11-01 00:00:00

  • A flexible 9-channel coil array for fast 3D MR thermometry in MR-guided high-intensity focused ultrasound (HIFU) studies on rabbits at 3 T.

    abstract::Signal-to-noise ratio (SNR) is a critical factor in MR-guided high-intensity focused ultrasound (HIFU) for local heating, which can affect the accuracy of temperature measurement. In order to achieve high SNR and higher temporal resolution, dedicated coil arrays for MR-guided HIFU applications need to be developed. In...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.10.008

    authors: Chen Q,Li Y,Jiang R,Zou C,Tie C,Wen J,Yang X,Zhang X,Liu X,Zheng H

    更新日期:2020-01-01 00:00:00

  • In vivo31P-MRS of muscle bioenergetics in marine invertebrates: Future ocean limits scallops' performance.

    abstract:OBJECT:Dynamic in vivo31P-NMR spectroscopy in combination with Magnetic Resonance Imaging (MRI) was used to study muscle bioenergetics of boreal and Arctic scallops (Pecten maximus and Chlamys islandica) to test the hypothesis that future Ocean Warming and Acidification (OWA) will impair the performance of marine inver...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.06.003

    authors: Bock C,Wermter FC,Schalkhausser B,Blicher ME,Pörtner HO,Lannig G,Sejr MK

    更新日期:2019-09-01 00:00:00

  • Quantitation of normal canine hippocampus formation volume: correlation of MRI with gross histology.

    abstract::The hippocampal formation possesses an important role in the development and maintenance of short-term memory. In this study, magnetic resonance imaging (MRI) and gross histology were used to quantify the volume of the hippocampal formation in canines. High resolution MRI, using 1 mm thick slices and an intraplanar re...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(95)02083-6

    authors: Vullo T,Deo-Narine V,Stallmeyer MJ,Gomez DG,Cahill PT

    更新日期:1996-01-01 00:00:00

  • Multicontrast multiecho FLASH MRI for targeting the subthalamic nucleus.

    abstract::The subthalamic nucleus (STN) is one of the most common stimulation targets for treating Parkinson's disease using deep brain stimulation (DBS). This procedure requires precise placement of the stimulating electrode. Common practice of DBS implantation utilizes microelectrode recording to locate the sites with the cor...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2012.02.006

    authors: Xiao Y,Beriault S,Pike GB,Collins DL

    更新日期:2012-06-01 00:00:00

  • STrategically Acquired Gradient Echo (STAGE) imaging, part II: Correcting for RF inhomogeneities in estimating T1 and proton density.

    abstract:PURPOSE:To develop a method for mapping the B1 transmit (B1t) and B1 receive (B1r) fields from two gradient echo datasets each with a different flip angle and from these two images obtain accurate T1 and proton density (PD) maps of the brain. METHODS:A strategically acquired gradient echo (STAGE) data set is collected...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.10.006

    authors: Wang Y,Chen Y,Wu D,Wang Y,Sethi SK,Yang G,Xie H,Xia S,Haacke EM

    更新日期:2018-02-01 00:00:00

  • Tissue sodium concentration and sodium T1 mapping of the human brain at 3 T using a Variable Flip Angle method.

    abstract:PURPOSE:The state-of-the-art method to quantify sodium concentrations in vivo consists in a fully relaxed 3D spin-density (SD) weighted acquisition. Nevertheless, most sodium MRI clinical studies use short-TR SD acquisitions to reduce acquisition durations. We present a clinically viable implementation of the Variable ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2019.01.015

    authors: Coste A,Boumezbeur F,Vignaud A,Madelin G,Reetz K,Le Bihan D,Rabrait-Lerman C,Romanzetti S

    更新日期:2019-05-01 00:00:00